AC centrifugal fan
D2E097-BI56-02
forward curved, dual inlet
with housing (without flange)
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2 · D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
Limited partnership · Headquarters Mulfingen
County court Stuttgart · HRA 590344
General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen
County court Stuttgart · HRB 590142
Nominal data
Type
D2E097-BI56-02
Motor
M2E052-CA
Phase
1~
1~
Nominal voltage
VAC
230
230
Frequency
Hz
50
60
Type of data definition
fa
fa
Valid for approval / standard
CE
CE
Speed
min-1
1950
1850
Power input
W
87
100
Current draw
A
0.39
0.45
Motor capacitor
µF
2
2
Capacitor voltage
VDB
400
400
Min. back pressure
Pa
0
0
Max. ambient temperature
°C
40
35
ml = max. load · me = max. efficiency · fa = running at free air · cs = customer specs · cu = customer unit
Subject to alterations
Item no. 11017-5-9980 · Revision 71618 · Release 2010-10-21 · Page 1 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC centrifugal fan
D2E097-BI56-02
forward curved, dual inlet
with housing (without flange)
Technical features
Mass
1.5 kg
Size
97 mm
Surface of rotor
Partially cast in aluminium
Material of impeller
Sheet steel, hot-galvanised
Housing material
Sheet steel, hot-galvanised
Direction of rotation
Counter-clockwise, seen on rotor
Type of protection
IP 20
Insulation class
"B"
Max. permissible ambient motor
temp. (transp./ storage)
+ 80 °C
Min. permissible ambient motor
temp. (transp./storage)
- 40 °C
Mounting position
Any
Condensate discharge holes
None
Operation mode
S1
Motor bearing
Ball bearing
Touch current acc. IEC 60990
(measuring network Fig. 4, TN
system)
< 0.75 mA
Motor protection
Thermal overload protector (TOP) wired internally
Protection class
I (if protective earth is connected by customer)
Product conforming to standard
EN 60335-1; CE
Approval
CCC; GOST
Item no. 11017-5-9980 · Revision 71618 · Release 2010-10-21 · Page 2 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC centrifugal fan
D2E097-BI56-02
forward curved, dual inlet
with housing (without flange)
Product drawing
1
Connection line PVC 4G 0.5 mm², 4 x brass lead tips crimped
Connection screen
U1
blue
PE
green/yellow
Z
brown
U2
black
Item no. 11017-5-9980 · Revision 71618 · Release 2010-10-21 · Page 3 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC centrifugal fan
D2E097-BI56-02
forward curved, dual inlet
with housing (without flange)
Charts: Air flow 50 Hz
Druck p f s[Pa]für Rho=1,2kg/m^3
260
0
50
qv[cfm]
150
100
200
250
250
1
240
0,95
230
220
210
4
200
0,9
Measurement: LU-34651
0,85
Air performance measured as per ISO 5801
Installation category A. For detailed
information on the measuring set-up, please
contact ebm-papst. Suction-side noise
levels: LwA measured as per ISO 13347 /
LpA measured with 1m distance to fan axis.
The values given are valid under the
measuring conditions mentioned above and
may vary according to the actual installation
situation. With any deviation from the
standard set-up, the specific values have to
be checked and reviewed with the unit
installed.
0,8
190
0,75
180
0,7
170
0,65
160
3
0,6
p fs_E[IN H2O]
150
pf s[Pa]
140
0,55
130
0,5
120
110
0,45
100
0,4
90
0,35
2
80
0,3
70
60
0,25
50
0,2
40
0,15
30
0,1
20
a]
pf s[P
10
0
0,05
1
0
20
40
60
0
80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480
qv[m^3/h]
Measured values
U
f
n
Pe
I
qv
pfs
V
Hz
min-1
W
A
m3/h
Pa
1
230
50
1950
87
0.39
435
0
2
230
50
2235
81
0.35
375
80
3
230
50
2470
73
0.32
295
150
4
230
50
2710
67
0.31
170
200
U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · qv = Air flow · pfs = Pressure increase
Item no. 11017-5-9980 · Revision 71618 · Release 2010-10-21 · Page 4 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC centrifugal fan
D2E097-BI56-02
forward curved, dual inlet
with housing (without flange)
Charts: Air flow 60 Hz
Druck p f s[Pa]für Rho=1,2kg/m^3
350
0
20
40
60
80
100
120
qv[cfm]
140
160
180
200
220
240
260
340
1,35
330
1,3
320
310
1,25
300
1,2
290
4
280
1,15
1,1
270
260
1,05
3
250
1
240
0,95
230
0,9
220
210
0,85
200
0,8
190
0,75
180
0,7
170
p fs_E[IN H2O]
pf s[Pa]
1,4
Air performance measured as per ISO 5801
Installation category A. For detailed
information on the measuring set-up, please
contact ebm-papst. Suction-side noise
levels: LwA measured as per ISO 13347 /
LpA measured with 1m distance to fan axis.
The values given are valid under the
measuring conditions mentioned above and
may vary according to the actual installation
situation. With any deviation from the
standard set-up, the specific values have to
be checked and reviewed with the unit
installed.
0,65
160
150
0,6
2
140
0,55
130
0,5
120
110
0,45
100
0,4
90
0,35
80
0,3
70
60
0,25
50
0,2
40
0,15
30
a]
pf s[P
20
10
0
Measurement: LU-34652
1
0
20
40
60
80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440
qv[m^3/h]
0,1
0,05
0
Measured values
U
f
n
Pe
I
qv
pfs
V
Hz
min-1
W
A
m3/h
Pa
1
230
60
1850
100
0.45
410
0
2
230
60
2500
93
0.40
340
140
3
230
60
2995
81
0.35
230
250
4
230
60
3210
74
0.32
140
280
U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · qv = Air flow · pfs = Pressure increase
Item no. 11017-5-9980 · Revision 71618 · Release 2010-10-21 · Page 5 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com