0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
FF80

FF80

  • 厂商:

    EBMPAPST(依必安派特)

  • 封装:

    插件

  • 描述:

    FAN FILTER ASSEMBLY 80MM

  • 数据手册
  • 价格&库存
FF80 数据手册
Compact fans for AC and DC The engineer’s choice version 2011 Trendsetter in fan technology Uncompromising quality made by ebm-papst Among the best. Trendsetting with innovative technologies. Listening to customers’ needs. Developing new ideas to meet requirements and realising them with pioneering spirit. This philosophy has made ebm-papst the technological leader in the world of fans. A brand which has very little real competition because every fan is a product of decades of application expertise gained from large-volume production and because we are in a position to produce highly efficient quality products. Our intelligent solutions for electronics cooling ensure that you are one step ahead of competitors thanks to innovative, reliable top-quality technology which is cost-favourable and in line with market requirements. And if required, tailor-made right down to the last detail. In other words, if you need fans which do not yet actually exist, contact us. Insist on ebm-papst. 2 Information DC axial fans DC fans - specials – Speed signal – Alarm signal – Vario-Pro® – Speed setting – Protected fans 110 114 119 120 123 ACmaxx / i-maxx – Axial fans 125 AC axial fans – Axial fans 141 AC centrifugal fans – Centrifugal fans 163 Accessories – Guard grilles – Filter guard grilles – Inlet nozzles – Connection cables – Accessories 174 180 182 183 184 ebm-papst representatives & subsidiaries 186 3 DC centrifugal fans 75 105 DC fans - specials DC centrifugal fans – Centrifugal fans – Tangential fans ACmaxx / i-maxx 17 AC axial fans DC axial fans – Axial fans AC centrifugal fans 4 6 8 10 12 13 14 15 16 Accessories Information – The company – GreenTech: The Green Company – Expertise and technology – Tailor-made – Types of fans – Selecting the correct fan – Fan installation – Service life – Definitions Representatives Table of contents Company profile: ebm-papst The entire scope of ventilation and drive technology: this is the world of ebm-papst. More than 10,000 people – in Germany and throughout the world – develop, produce and sell our motors and fans. Our global presence and our unique range of products based on a quality standard that surpasses every other have made us what we are: world market leader in motors and fans. Expertly knowing what our customers need and incessantly striving to arrive at the perfect application solution for a wide variety of different industries is what determines our daily work. Those who know us know the high standards we apply to our work and know our creed: to be as close to our customers as possible and to simply be the best in terms of innovation and reliability. Our location in St. Georgen 4 Information DC axial fans Left: DC centrifugal fans Our headquarters in Mulfingen Right: clearance for serial production only after all the Rooted in ebm, PAPST and mvl, the three leading innovators in the desired characteristics have been determined to development and production of motors and fans, ebm-papst has be just right. established itself as the world market leader. Now as ever, our legendary Environmental care is another priority with inventive spirit shines through in products that set standards in many ebm-papst. This is why we have developed segments of industry worldwide. We are proud to say that despite difficult our product line in EC technology, which makes competition, our performance has always been exemplary and outstand- for very low power consumption. Due to our ing – in business, in our personal relationship with our customers, and of manufacturing philosophy, there is absolute course with respect to technology and engineering. For decades, we have focus on environmental care in production, contributed to the world of air technology and drive engineering with recycling, waste and wastewater disposal. ACmaxx / i-maxx Our history – Our drive DC fans - specials Our location in Landshut small revolutions and large milestones. To maintain this advantage in skills and knowledge to get maximum Global Domestic quality and thus the highest degree of customer satisfaction, our In order to be specialist for customised solutions employees around the world put their passion and dedication to work throughout the world, you need strong partners. for you. Global Domestic – i.e. being present all over the ourselves in all important markets on this globe products of highest quality and reliability. After all, it is our passion to with our successful subsidiaries. And so you will constantly try something new and improve what we have. In doing so, always find ebm-papst close to home, speaking we take advantage of the latest development methods and state-of- your language, and knowing the demands of the-art technology and invest quite heavily in R&D facilities. Best of all, your markets. Besides, our worldwide produc- though, we rely on excellently trained and skilled engineers and tion alliance serves as a basis for competitive technicians to be at your service in R&D and Sales & Distribution. pricing. Our global services and logistic outlets, AC centrifugal fans Our catalogues just list the results of our incessant efforts in R&D: i.e. IT networking, safeguard short reaction Producing and safeguarding high-quality products and services times and just-in-time delivery. our six factories in Germany or one of our eleven international production All our efforts are documented in a comprehen- sites, our products always have the same high level of quality. This quality sive quality management system, both for prod- control is something you can definitely rely on! And this across all levels ucts and services. Being certified as complying of production and throughout all processes: consulting customers, devel- with the tough requirements of the international opment, material selection through to picking certified, choice suppliers standards DIN EN ISO 9001, ISO/TS 16949-2 and on to the production of parts and final delivery. On top of this, our and of standard DIN EN ISO 14001 is just one products have to pass the most rigorous tests under all realistic operating seal of approval we have received for our conditions: continuous stress test, salt spray test, vibration test, or preci- unceasing efforts to provide only the best sion noise measuring, just to mention a few. And the product gets quality products and services. Accessories This is our promise without any compromise. Whether produced in one of 5 Representatives individual country – is how we have established AC axial fans world and being a national company in each Passionately involved in R&D Sustainability is at the centre of our thoughts and actions. Out of conviction! Eco-friendliness and sustainability have always been at the core of our thoughts and actions. For decades, we have worked according to the simple but strict creed of our co-founder Gerhard Sturm: “Each new product we develop has to be better than the last one in terms of economy and ecology.” GreenTech is the ultimate expression of our corporate philosophy. Information DC axial fans DC centrifugal fans DC fans - specials ACmaxx / i-maxx GreenTech is acknowledged and certified. Even in the design phase, the materials and processes we use are optimi- Every step in our chain of production meets the stringent standards of sed for the greatest possible eco-friendliness, energy balance and – environmental specialists and the public. The 2008 Environmental Prize wherever possible – recyclability. We continually improve the material of Baden-Wuerttemberg, the Green Award 2009, the Energy Efficiency and performance of our products, as well as the flow and noise charac- Award 2009 of the dena – to give just a few examples – testify to this. teristics. At the same time, we significantly reduce energy consumption. The environmental advantage gained in the performance of the products Close co-operation with universities and scientific institutes and the pro- developed from our GreenTech philosophy can also be measured in the fessorship we endow in the area of power engineering and regenerative fulfilment of the most stringent energy and environmental standards. energies allows us to profit from the latest research findings in these In many instances, our products are already well below the thresholds fields – and at the same time ensure highly qualified young academics. energy legislation will impose a few years from now – several times over. GreenTech is eco-friendly production. Our customers profit from this every day. GreenTech also stands for maximum energy efficiency in our production The heart of GreenTech is future-oriented EC technology from ebm- processes. There, the intelligent use of industrial waste heat and ground- papst. The EC technology at the core of our most efficient motors and water cooling, photovoltaics and, of course, our own cooling and venti - fans allows efficiency of up to 90%, saves energy at a very high level, lation technology are of the utmost importance. Our most modern plant, significantly extends service life and makes our products maintenance- for instance, consumes 91% less energy than currently specified and free. These values pay off not only for the environment, but every cent al- required. In this way, our products contribute to protecting the environ- so pays off for the user! All ebm-papst products – even those for which ment, from their origin to their recyclable packaging. GreenTech EC technology does not (yet) make sense from an application viewpoint – feature the greatest possible connection of economy and Accessories AC centrifugal fans AC axial fans GreenTech is pro-active development. 7 Representatives ecology. Expertise and technology Drive expertise Long service life For the past 60 years, all conceivable types and applications of drive The bearing system plays a vital role both in engineering have played an essential role at ebm-papst. A commitment the long life time and quietness of device that is the foundation for the development of optimum drive solutions – fans. The SINTEC compact bearing provides regardless of the type of fan and its usage. DC fans are generally most of the device fans with a proven bearing equipped with electronically commutated external rotor motors; in system. Constant low noise during the entire order to save as much space as possible, commutation electronic com- operating time and considerably lower shock ponents are integrated in the hub of the fan. Our AC fans are mostly sensitivity are the outstanding features of this driven by shaded-pole or capacitor motors based on the external rotor bearing technology. In addition, with regard principle. In the 3900 and 9900 range of particularly slim fans, internal to temperature endurance, Sintec compact rotor motors are used. bearings can be used without problems in most applications. Despite the slightly higher Low-noise performance noise and shock sensitivity of ball bearings, Our aerodynamically optimised design and high mechanical precision this bearing technology should be given pref- produces outstanding noise properties in series production. So-called erence for fans exposed to extreme thermal “soft” commutation electronics of the DC fans ensure an excellent and adverse application conditions (e.g. noise performance. By avoiding steep switching edges when the indi- extreme environmental conditions, critical vidual coils are switched, this reduces the structure-borne noise from installation position, etc.). The service life data the motor. Computer-aided measurements and series of analyses per- provided in this catalogue is based on exten- formed in a state-of-the-art sound measuring chamber are conducted sive service life tests and mathematically / on each fan model from the very beginning. scientifically proven service life calculations. Our product descriptions are continuously updated with all relevant data obtained from long-term tests. 8 Information DC axial fans DC centrifugal fans Safety is included It goes without saying that all ebm-papst fans DC fans - specials conform to the approval requirements of the VDE (Association of German Electrical Engineers) and the standards and regulations of UL and CSA. All fans conform to the European Standard EN 60335 or EN 60950 plus those of the UL (Underwriters Laboratories) and CSA (Canadian Standards Association). to meet the requirements of protection class 3 With the aid of state-of-the-art computer programs, we are able to / protection class voltage. ACmaxx fans are optimise the fan impellers and the inner shape of the housing. Air protection class 2 / AC fans are protection output and available motor performance are exactly matched with the class 1. ebm-papst fans meet the highest size of fan. This guarantees the low noise that is typical for ebm-papst, requirements of electrical safety. Depending on even at high back pressure. the type, they are either impedance protected ACmaxx / i-maxx With few exceptions, our DC fans are designed Streamline: Aerodynamics Sturdy construction – in metal or plastic electronic locked-rotor protection, alarm func- Fans of all-metal construction: Sturdy and indestructible. The housing tion or have speed monitoring and speed con- is made of an aluminium alloy whereas the metal surfaces that are trol. AC axial fans or equipped with a temperature safety switch, Quality in detail sion is highly recyclable. Fans with fibreglass-reinforced plastic hous- It is the seemingly trivial that makes the ing and impeller: Excellent stability and low weight distinguish difference when a product is labelled ‘made this highly efficient fan concept. Combinations of metal housing and by ebm-papst’: consistent maintenance of plastic impeller unite the advantages of both types of design. development and design engineering specifica- Product images quality across the entire process chain are the The dimensioned drawings and product photos that appear in the catalo- reasons why running times of over 150,000 gue are for orientation purposes and may differ in some details from the hours are not unusual. The no-compromise actual product design. ebm-papst quality assurance spans over all Accessories tions; target-oriented design; and assured process levels – from the choice of materials Product liability and the use of carefully selected, certified sup- Motors and fans from ebm-papst are components intended for proper pliers, from the production of parts up to final installation. The customer bears responsibility for the overall end pro- assembly. The sum of all these apparently duct. minor details results in fan products with superior lifetimes and reliability. 9 Representatives abrasion-resistant electrophoretic baked enamel. This particular ver- AC centrifugal fans subject to corrosion are permanently protected by an impact- and Tailor-made to meet your special requirements Practice-oriented: Fans – customised and intelligent ebm-papst has always developed customerspecific intelligent fans which meet the exact requirements of the application. We provide a wide range of standard fan types, in many sizes and designs; with intelligent motor features, monitoring and control functions as well as special designs for use under extreme conditions. They are all based on the standard type fans which you will find in this catalogue. Special fan types for your application can be produced in economical batch sizes. Our expert engineers will assist you in selecting the right configuration. Innovation at its best: Vario-Pro® with “intelligence inside”. Its programmed intelligence thanks to customer-specifically configured software modules makes the cooling of electronics even more economical and flexible. For example, temperaturedependent speed profiles are possible with a number of freely selectable interpolation points. External speed settings and a variety of combinable alarm and tachometer functions can also be programmed. The digital motor management achieves high control accuracy. 10 Information DC axial fans ebm-papst provides, on request, many fan series in versions which thanks to sensor signal conform to the requirements of Protection Class IP 54: Their stator and Do you wish to be informed about the current all electrical components are fully encapsulated. Stainless steel ball fan speed at all times? ebm-papst has fans bearings can be used for operation in particularly aggressive media with an integrated “electronic tachometer” and use under extreme environmental conditions, thus providing addi- which registers the actual value of the fan tional reliability. speed. Via an integrated sensor, the fan gen- DC centrifugal fans “Electronic tachometer” DC fans - specials Higher protection class for every type of application directly utilised. Depending on the number of Regardless of your cooling and ventilation tasks, we develop the right poles of the motor, 2, 3 or 6 pulses per revo- solution and what is more, the most economical one. Based on the fans lution are generated. ACmaxx / i-maxx erates speed-dependent signals which can be Virtually everything is possible listed in this catalogue, well over 4000 different versions are available. Temperature-controlled fans If your application requires monitored fan Fans with temperature-controlled speed have particularly quiet cooling operation, in addition to speed monitoring, characteristics. Thanks to integrated IC technology, they adapt their ebm-papst also provides a multitude of speed to the current cooling requirements, which results in a drastic varying alarm signals. Depending on the type reduction of noise in most operating modes. A temperature sensor pro- of fan in question, the signal is either static, vides the fan with thermal information: either externally via a single already evaluated or interface-compatible. lead or integrated into the hub of the fan. The alarm signal output provides reliable AC axial fans Alarm signal for more safety longterm monitoring and a status signal if critical operating conditions evolve. provides an alternative to the NTC-controlled types of fans. They are S-Force especially suitable for systems and units which already have standard The new measure of things! interfaces for varying speed via internal switching and control circuits. When you need to provide extremely fast, The main applications are units which demand load-dependent individ- powerful and efficient cooling for electronic ual speed profiles or systems with stand-by minimum cooling require- components of all kinds, the generation of ments and varied speed increase at varying power peaks. S-Force high-performance fans finishes first: AC centrifugal fans With a wide range of DC fans with separate control input, ebm-papst Accessories in air performance, pressure build-up and technology. Extremely efficient drives and optimised aerodynamics form the core technology of the S-Force fans, which we offer in both an axial and brand-new centrifugal model. 11 Representatives Speed setting via interfaces Types of fans and their function Axial fans: High air flow with medium to relatively high pressure build-up The air flow in axial fans, whose impeller is similar to that of a propeller, is conducted to a great extent parallel to the axis of rotation, in other words in the axial direction. Axial fans with free air delivery at zero static pressure have the lowest power input that rises with increasing back pressure. Axial fans for cooling of electronic equipment are mostly equipped with external housing and an electric motor integrated into the fan hub. This compact design allows space-saving accommodation of all devices; the flange is equipped with mounting holes. Diagonal fans: High flow rate at relatively high pressure build-up At first glance diagonal fans only differ slightly from axial fans. Intake is axial, whereas exhaust is diagonal. Due to the conical shape of the wheel and housing, the air is pressurised more. In direct comparison with axial fans of the same size and comparable performance, these fans are distinguished by the lower operating noise at high pressures. Centrifugal fans: High pressure build-up at limited flow rate Many of the cooling problems that occur can be optimally solved by axial and/or diagonal fans. If, for example, the required cooling air has to be conducted at an angle of 90° or if even high pressure is necessary, centrifugal fans are more effective. For your application, ebm-papst offers not only complete centrifugal fans but also motor/impeller combinations without external housing. Tangential fans: High flow rate at low pressure Tangential fans are used above all-, for large-surface air flow in devices. The air flows through the roller-shaped impellers twice in the radial direction: in the intake area from the outside to the inside and in the outflow area from the inside to the outside. Whirls form in the roller due to the vanes which guarantee a steady flow of air through the impeller. 12 Information 2. Permissible temperature rise DC fans - specials Pa 15 [in H2O] 20 represents a suitable value for this purpose. 0,12 25 ved. The electrical power consumption of the unit to be cooled, often 0,10 it is important to determine the dissipated energy that must be remo- Optimum Operating Range 0,08 30 10 0,04 35 devices is converted into heat. In selecting the correct fan, therefore, 5 0,02 A large amount of the energy consumed by electrical and electronic 0,06 1. Dissipated energy DC centrifugal fans DC axial fans Selecting the correct fan The air flow which the selected fan is required to generate, is deter0,4 0,8 1 1,2 2 1,6 CFM 2,0 3 4 ACmaxx / i-maxx 0 mined by the dissipated energy and the permissible rise (ΔT) of the m³/h cooling air flow (from entry to exit of the device to be cooled). The max. allowable ΔT depends greatly on the temperature sensitivity of • Read down from this point to obtain the ge air flow leaving the device to be cooled may only be 5°C warmer required value for the cooling air flow. than the ambient temperature (a large volume of air is required for this The diagram is based on purpose). A lower air flow rate is sufficient if a higher temperature dif- the following formula: ference (e.g. ΔT = 20K), can be tolerated. AC axial fans the individual device components. ΔT = 5K means e.g. that the avera- Pv [w] V· [m3/h] ≈ 3 · ΔT [K] 3. Required cooling air flow • In the below diagram a horizontal line is drawn from the dissipated enery to intersect with the selected ΔT line. 4. Optimum operating range The required fan, however, must also be able to deliver a suitable static pressure increase AC centrifugal fans Δpf, in order to force the cooling air through the device. A fan must therefore be selected that provides the required air flow performance within its optimum operating range (see also Example : P v = 300 W att Δ t = 10 K 20 10 5. Fan selection filled by more than one fan, the noise level, space requirements, economy and ambient Waste Heat Pv 30 Δt5K If the requirements of an application are ful- 200 150 100 50 data). conditions will assist in making the final choice. 90 m³/h m³/h Air Flow 5 10 20 30 40 50 100 200 300 500 13 Representatives 500 300 Δ t 20 K Δ t 15 K Δ t 10 K Accessories Watt the air performance curves under technical 5000 1000 Fan installation Intake or exhaust side installation Baffle Under ideal conditions, the operating point is represented as the intersection between the fan and loss curves, regardless of whether the fan is positioned at the air intake or exhaust Multidirectional intake, laminar currents side of the device. In addition to ensuring the required flow rate, several additional aspects must be considered for determining an appropriate fan concept. The intake air currents of a fan are mainly laminar, comprising nearly the entire suction area. By contrast, the exhaust air of a fan is Unidirectional exhaust, turbulent generally turbulent, while it flows on a preferred direction, e.g. axial for an axial fan. The turbulences of the exhaust intensify the heat transfer from components within the air currents, so that mounting the fan at the air intake side of the device is recommended for cooling and heating. Mounting the fan at the Information on installation device intake is also advantageous because When a fan is operated for the first time in an application, the user may the fan will not be subjected to the dissipated have noticed that the flow rate in the device was lower than expected. heat of the device. Therefore, it operates at What is the reason for this? low ambient temperatures and has a higher • The values stated in this catalogue were determined under optimum, life expectancy. constant and comparable measurement conditions. • Ideal mounting conditions under which free air intake and exhaust are present are seldom feasible in practice. Quite frequently the fans must be mounted in close proximity to other components or cabinet Accident prevention panels. As a consequence, the intake and exhaust currents may be The turning rotor and the high speeds that restricted, causing the air flow to diminish and the noise level to are sometimes involved mean that our fan increase. Fans are particularly sensitive to obstructions which are products carry an inherent risk of injury. positioned directly in front of the output cross section as they often They may only be operated after correct cause an increase in tonal noise. installation and with suitable protective facilities (e.g. with a guard grille). More Our advice: The distance between the fan and adjacent components information can be found in the internet at: should be at least equal to the installation depth of the fan. www.ebmpapst.com/safety 14 Information Fans in an endurance test cabinet at ebm-papst St. Georgen. 1500 fans are operated in temperature cabinets until they fail. each product. The first column usually states the service life L10 at 40°C. the second column usually states the service life L10 at Tmax. Exceptions are marked in the column headings. The third column states before a representative number of failures have been registered, and even today, some fans are still in the process of endurance testing, even though they began tests in the 1980s. These fans Bel(A) These tests have given us years of experience in the way various design parameters and temperatures can affect the service life of a product. Data for service life at various temperatures Specials Curve L10Δ (40 °C) s. S. 15 Hours 67 500 / 35 000 140 000 1 P. 110 5,3 4,2 3 300 -20...+70 65 000 / 32 500 130 000 2 Example of the service life figures on the page of the catalogue. % X X = failure b>1 X 10 X X b»1 duct specifications and of commonalities in the design of the product. (h) L10 Failure rate l(t) Service life t t1 0 Type of error Premature failure tures. The service life at temperatures below the test temperatures is calculated using fixed fac- t2 Service life t the calculation methods conventionally applied in the compact fan market. Again here, the foundations for the service life values are our service life endurance tests at high ambient tempera- Life expectancy Hours -20...+70 for new products can be stated with a very high degree of precision on the basis of tests, pro- New: Life expectancy L10Δ (40°C) The new third service life column states the expected service life L10Δ. This value is based on Service life L10 (Tmax) ebm-papst standard °C 2 700 Probability of failure re tested is determined on the basis of the Weibull distribution. Service life L10 (40 °C) ebm-papst standard RPM 2,5 / are proof of the legendary reliability of fans from the Black Forest. Test results are presented in a diagram and the service life of the product L10 at the temperatu- Temperature range Watts 5,0 ACmaxx / i-maxx values, or when the operating noise becomes noticeable. Such tests can take several years Random failure b»1 b1 AC centrifugal fans tors. This method produces much higher service life values, especially at room temperature (see diagram on right). DC axial fans Our fans catalogue gives three different values for the service life of DC centrifugal fans Service life data from ebm-papst St. Georgen DC fans - specials Service life Bathtub curve and Weibull distribution. Summary: 2/10K assumptions. The values determined here are extrapolations from our own service life tests and from statistical variables. In the respective customer applications, different influences may occur 1,65/10K L 10Δ= 2/15K Accessories all allow statements to be made about the theoretical calculated service life under certain 1,5/10K + which cannot be included in the calculations due to their complexity. The service life information + is explicitly not a guarantee of service life, but strictly a theoretical quality figure. + ebm-papst standard 20 30 + + 40 50 60 70 Operating temperature (°C) 80 Example of the influence of factors from various manufacturers on the expected service life. 15 Representatives experience gained by ebm-papst. The specified L10 (40°C), L10 (Tmax) and L10Δ (40°C) values Expected service life The life span calculations have been carried out to the best of our knowledge and are based on Definitions Subject to technical alterations. Our products are not designed for use in the aerospace industry! German and international patents, registered designs and utility models. ebm-papst is a registered trademark of ebm-papst Mulfingen GmbH & Co. KG. PAPST, SINTEC, VARIOFAN and Vario-Pro are registered trademarks of ebm-papst St. Georgen GmbH & Co. KG. Nominal voltage (Volts) air density affect pressure generation but not Ball bearings The voltage at which the nominal values (the ta- the flow rate. The pressure generated at other Precision ball bearings for particularly high bular values listed in this catalogue) were deter- air densities may be estimated with the formula ambient temperatures and high service life mined. The fan operation for DC fans is not lim- Δρ2 = Δρ1 (ρ2 / ρ1). expectancy. ited to the nominal voltage. Fan speed and fan The nominal speed values, air flow and power performance can vary according to the permis- input listed in the table were measured in free Power input (Watts) sible voltage range that is specified on the air operation with horizontal shaft at an ambient Input performance of the fan motor when nameplate of each fan. temperature of 20 +5 °C, air density ρ = 1.2 kg/m3 after a warm-up period of 5 min. operating at nominal voltage. Depending on the Frequency (Hz) ebm-papst AC fans are made for operating frequencies of 50 Hz or 60 Hz. Their technical data operating condition in the application, the power input may be higher. Optimum operating range During operation, fans are required to produce Temperature range (°C) an air flow with a simultaneous increase of The permissible ambient temperature range Air flow (m3/h) pressure. These operating conditions are within which the fan can be expected to run The air performance of the fan in free air opera- described in the section “Optimum Operating continuously. tion, i.e. the fan blows into the free space with- Range”. The optimum operating range is there- out static pressure build-up. fore always indicated in this catalogue in the Service life [h] shaded area. In this range the fans operate best Fan curves Service life L10 at 40°C and Tmax with respect to efficiency and noise level. Within The fan curves are determined in accordance Standard figures for service life at ebm-papst. this optimum operating range the noise level with DIN 24 163 specifications on a dual-cham- These two temperatures are based on intensive, only fluctuates insignificantly. in-house endurance tests and on the experience alter accordingly. ber test stand with intake-side measurement. This measurement technique closely approximates the operating conditions experienced in typical applications for fans and yields realistic performance curves. The curves apply to an air density of ρ = 1.2 kg/m3, corresponding to an air pressure of 1013 mbar at 20 °C. Variations in more than 60 years developing fans. Noise [dB(A), Bel(A)] 1. Sound pressure level – dB(A) Life expectancy L10Δ Δ (40°C) Figures oriented towards the calculation metho- Noise ratings of the fan in free air operation, i.e. ds employed by other fan manufacturers. Data at maximum flow rate. based on the internal expected service life at 2. Sound power level – Bel(A) / dB(A) 70°C, more optimistically extrapolated to 40°C. Pa The sound power level is determined in the Fan Curve optimum operating range. 0,12 25 0,10 20 0,08 15 0,06 10 0,04 Optimum Operating Range 30 – Very precise, large sintered bearings 0,02 35 [in H2O] Extent of the overall sound radiation of the fan. – Low running noise 5 0 PAPST Sintec® sleeve bearings A particularly efficient bearing system with excellent qualities: 0,4 0,8 1 16 1,2 2 1,6 2,0 3 CFM 4 m³/h – High service life expectancy – Insensitive to shock and vibration We expressly state that none of the information or data in this catalogue is to be construed as a guarantee or warranty of properties. Unit conversion Air flow Pressure 1cfm = 1,7 m3/h 1l/s = 3,6 m3/h 1Pa = 1x10-5bar 1 inch H2O = 249 Pa 1l/min = 0,06 m3/h 1 mm H2O = 9,81 Pa ACmaxx / i-maxx DC fans - specials DC centrifugal fans 23 AC axial fans DC axial fans / DC diagonal fans AC centrifugal fans 19 Accessories DC axial fan overview 17 Representatives DC axial fans Information DC axial fans DC fans Technical information Range of fans Voltage range ebm-papst offers you the widest full product Many of our DC fans can be operated on volta- line of DC axial and diagonal fans: From 25 mm ges that are up to 50% lower and 25% higher to 280 mm in size. Every single type of fan can than their nominal voltage (see Voltage range in be optimally integrated in the respective device the technical tables). This enables the air per- concept. The highly economical brushless motor formance to be adapted to the cooling require- technology of these fans provides a unique ments and allows the noise to be reduced, even variety of intelligent innovations that can be if the fan does not have a control input. realised today at prices that would have been unthinkable just a few years ago. Closed-loop speed control and monitoring Closed-loop speed control and function monito- Electronic protection against ring are becoming increasingly important in reverse polarity many applications. ebm-papst offers many fans ebm-papst DC fans have electronically commu- in the standard design with a control input and tated drives with electronic protection against open collector speed signal. reverse polarity.The electronics are conveniently located in the fan hub. S-Force Product life expectancy The new S-Force fans with their extremely high blower capacity of up to 950 m3/h and pressu- A distinctive feature of DC fan technology is re build-up of up to 1200 pascals are capable the convincingly high product life expectancy. of dealing with the extreme heat load. If nee- Thanks to the excellent efficiency of the brush- ded, these fans can produce up to 100% more less drives, the thermal load of the bearings is output under full load and they work with a reduced, thus considerably increasing the life much broader delivery bandwidth than current expectancy of the fans. models. This makes them ideal for equipment and systems with a high density of compo- Protection class nents. Thanks to intelligent motor features, they DC fans with sleeve and ball bearings are pow- can be individually adapted for any application. ered by Class E insulated motors. All ebm-papst S-Force fans are available in 5 standard dimen- fans conform to the requirements of protection sions. class IP 20. Fans conforming to IP 54 and special protection classes are also available. 18 m3/h Information Page 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW 10 3000 20 30 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 DC centrifugal fans 50 DC fans - specials 40 ACmaxx / i-maxx 30 AC axial fans Air flow 250 2,1...4,5 400 F 6...9 400 10...13,5 400 J 19...24 500 F 11...20 600 F 19...33 620 21...67 630 40...44 600 N 21...56 600 N VARIOFAN 16...41 600 J 70...84 700 F 28...44 8450 33...118 8400 N 33...79 8400 N VARIOFAN 20...58 8300 32...80 8200 J 132...222 3400 N 61...102 3400 N VARIOFAN 44...84 3300 56...107 3200 J 130...280 4400 F 94...170 4400 FN 200...225 4300 95...204 4300 VARIOFAN 61...170 4400 150...285 4100 N 160...237 4100 NHH..NH6 260...440 4100 NH7..NH8 500...570 DV 4100 275 5200 N 187...338 DV 5200 270...324 5100 N 122...250 5300 338 5300 TD 410...670 7100 N 360...420 7200 N 360 6100 350 6300 395...545 6300 TD 600...950 6300 TD 710...950 DV 6200 540 DV 6200 TD 100...700 6400 205...480 6400 TD 90...900 DV 6400 530 DV 6400 TD 100...680 2200 FTD 790...1220 W1G 200 1090 K1G 200 1020...1245 K3G 200 1215...1640 W1G 250 1920 20 AC centrifugal fans  10 Accessories 25 x 8 40 x 10  40 x 20  40 x 25  50 x 15  60 x 15  60 x 25  60 x 25  60 x 25  60 x 25  60 x 32  70 x 15  80 x 25  80 x 25  80 x 25  80 x 32  80 x 38  92 x 25  92 x 25  92 x 32  92 x 38  119 x 25  119 x 25  119 x 32  119 x 32  119 x 38  119 x 38  119 x 38  119 x 38  119 x 38  127 x 38  127 x 38  135 x 38  140 x 51  140 x 51 Ø 150 x 38 Ø 150 x 55 172x160x52 Ø 172 x 51 Ø 172 x 51 172x160x51 Ø 172 x 51 Ø 172 x 51 172x150x51 172x150x51 172x160x51 172x160x51 220x200x51  225 x 80  225 x 80  225 x 89  280 x 80  m3/h 3000 19 Representatives mm Series Dimensions Overview of air performance DC axial fans Axial fans for DC operation Optional special versions Information on pictograms On the pages of the catalogue and on the following overview pages, the pictograms illustrated below provide information about technically possible special versions in the fan line presented. Please note that these special versions are not possible for all voltages and speeds, and not in all combinations. The special versions are designed for specific customers and projects and are not usually available off the shelf. PWM control input Speed signal The fan uses a separate wire to output information about its speed, and thus about the speed of the rotor. NG PWM The speed of the fan can be changed via a pulse-widthmodulated signal. This signal is applied to a specially For technical details, please refer to page 110. provided wire. For technical details, please refer to Go / No-go alarm page 121. The fan uses a separate wire to output a static signal Analogue control input when it is stationary, thus providing information about whether or not the rotor is turning. For technical A The speed of the fan can be changed via a control voltage. This control voltage is applied to a specially provided details, please refer to page 117. wire. For technical details, please refer to page 121. Alarm with limit speed Multi-option control input If the speed drops below a certain level defined in the The fan has a control input that the user can trigger eit- fan's electronics, the fan will emit a static signal, thus her using a PWM signal, an analogue signal or a providing information about whether or not the rotor is resistor. For technical details, please refer to page 122. turning. For technical details, please refer to page 114. External temperature sensor T An NTC is connected to the fan via a separate wire and the fan changes its speed depending on the temperatu- HP re at the NTC. For technical details, please refer to page 120. Internal temperature sensor I In this case, the NTC is integrated into the fan and the Protection for the fan's electronics against moisture and condensation. For technical details, please refer to page 123. Û IP54 IP 54 Protection of motor and PCB board against splashed water and humidity. For technical details, please refer to fan changes its speed depending on the temperature at page 123. the NTC. For technical details, please refer to page Protection against salt spray fog 120. 20 Protection against moisture SP Protection of fan against the damaging effects of salt spray fog. For technical details, please refer to page 123. Information Axial fans for DC operation Series mm P. for all voltages and speeds, and not in all combinations. 250 25 x 25 x 8 yes • – – – – – – • – – 23 The special versions are designed for specific custo- 400 F 40 x 40 x 10 yes • • – – – – – – • – – 24 mers and projects. As a rule they are not available off 400 40 x 40 x 20 yes • • – – – • – – • – – 25 the shelf and are tied to minimum volumes. 400 J 40 x 40 x 25 yes • • – – – – – • • – 26 500 F 50 x 50 x 15 yes • • – – – • – – • – – 27 600 F 60 x 60 x 15 yes • • – – – • – – • – – 28 • • • • • • • – • • – 29 • • • • • • • – • • • 30 600 N 60 x 60 x 25 yes / • • – • • – – – • • – 31 600 N VARIOFAN 60 x 60 x 25 yes / • • – • • – – – • – – 32 NEW 600 J 60 x 60 x 32 yes • • – – – – – – • – – 33 700 F 70 x 70 x 15 yes • • – – – – – – • – – 34 NEW 8450 80 x 80 x 25 yes • • – – – • – – • – – 35 80 x 80 x 25 yes • • • • • • • – • • – 36 8400 N VARIOFAN 80 x 80 x 25 yes • • – • • – – • – – 37 • • • • • • • – • • • 38 • • • • • • • – • – – 39 • • • • • • • – • • – 40 • • – • • – – • – – 41 • • • • • • • – • • • 42 • • • • • • • – • • – 43 • • • • • • • – • – – 44 • • • • • • • – • – – 45 • • • • • • • – • • • 46 • • • • • • • – • – – 47 • • • • • • • – • – – 48 • • • • • • • – • • • 49 8300 80 x 80 x 32 yes 8200 J S-Force 80 x 80 x 38 yes 3400 N 92 x 92 x 25 yes 3400 N VARIOFAN 92 x 92 x 25 yes 3300 92 x 92 x 32 yes 3200 J 92 x 92 x 38 yes 4400 F 119 x 119 x 25 yes 4400 FN 119 x 119 x 25 yes 4300 119 x 119 x 32 yes 4300 VARIOFAN 119 x 119 x 32 yes / / / / / / – – 4400 119 x 119 x 38 yes 4100 N 119 x 119 x 38 yes 4100 NH..NH6 119 x 119 x 38 yes • • • • • • • – • – – 50 / 4100 NH7..NH8 119 x 119 x 38 yes • • • • • • • – • – – 51 DV 4100 119 x 119 x 38 yes • • • • • • • – • • • 52 5200 N 127 x 127 x 38 yes • • • • • • • – • • • 53 DV 5200 127 x 127 x 38 yes • • • • • • • – • • • 54 5100 N 135 x 135 x 38 yes • • • • • • • – • • • 55 140 x 140 x 51 yes • • • • • • • – • • • 56 140 x 140 x 51 yes • • • • • • • • • – – 57 NEW 5300 S-Force 5300 TDS-Force 7100 N 150 Ø x 38 yes • • • • • • • – • • • 58 7200 N 150 Ø x 55 yes • • • • • • • – • • • 59 NEW 6100 N 172 x 160 x 51 yes • • • • • • • – • • • 60 NEW 6300 S-Force 172 Ø x 51 yes • • • • • • • – • • • 61 NEW 6300 TDS-Force 172 Ø x 51 yes • • • • • • • • • • • 62 NEW 6300 TDS-Force 172 x 160 x 51 yes • • • • • • • • • • • 63 DV 6200 172 Ø x 51 yes • • • • • • • – • • • 64 DV 6200 TD 172 Ø x 51 yes • • • • • • • – • • • 65 6400 172 x 150 x 51 yes • • • • • • • – • • • 66 6400 TD 172 x 150 x 51 yes • • • • • • • – • • • 67 DV 6400 172 x 160 x 51 yes • • • • • • • – • • • 68 DV 6400 TD 172 x 160 x 51 yes • • • • • • • – • • • 69 200 Ø x 51 yes • • • • • • • • • • • 70 NEW 2200 FTD W1G 200 225 x 225 x 80 UL/CSA • • • • – • • • • – • 71 NEW K1G 200 225 x 225 x 80 yes • • • • – • • • • – • 72 NEW K3G 200 225 x 225 x 89 yes • • • • – • • • • – • 73 W1G 250 280 x 280 x 80 UL/CSA • • • • – • • • • – • 74 DC fans - specials yes yes ACmaxx / i-maxx 60 x 60 x 25 60 x 60 x 25 about the feasibility of your special variant. AC axial fans 620 NEW 630 Please consult your customer support representative AC centrifugal fans – Accessories – * approvals applied for – not yet available • available Sleeve bearings Ball bearings 21 Representatives OPTIONAL DC centrifugal fans Please note that these special versions are not possible Axial fans 8400 N DC axial fans No-g Alarm o alarm with limit spee Exte rnal d t e m pera Inter ture nal t emp sens eratu PWM o re se r con nsor Analo trol inpu t gue cont rol in Mult put i-op tion cont rol in Hum put idity prot IP > ectio = IP n 54 Salt spra y fog prot ectio Page n Go / Sens or eve CSA c sle Sinte VDE , UL, Dim ensio ns bear ings /ball bear ings Overview of technically feasible designs Connection instructions for S-Force fans Special features of S-Force fans The S-Force series is the most powerful product series on the market. S-Force stands for the highest innovation in motor technology, fluid mechanics and electronics. The one-of-a-kind power density of the products requires special attention to the application at the customer's facility. Service life +Vs Due to the high currents in the fans, the load on the electrolyte capacitors is greater, which reduces the service life of the capacitor. As a larger or additional capacitor cannot be housed in the fan, the capacitor Power Supply Microcontroller must be housed in the supply line. GND If the power pack of the application has a corresponding capacitor, in some cases it may be possible to omit the external capacitor. Fan M Recommended measure: Additional external capacitor (thus must be installed as close to the fan as possible < 30 cm). Capacitor Recommended capacitors required We recommend using the following capacitors from Rubycon: 24 VDC: 50 ZL 680 μF; 12,5 mm x 30 mm or S-Force axial 50 ZLH 680 μF 12,5 mm x 30 mm 8200 / 3200 JH3-JH4 no 4100 NH3 / NH4 / NH5 / NH6 no 4100 NH7 / NH8 yes 48 VDC: 5300 / 5300 TD no 100 YXG 470 μF; 16 mm x 35,5 mm or 6300 / 6300 TD no 100 ZLH 470 μF 16 mm x 31,5 mm 2200 FTD no Other capacitors with equal or greater capacitance and equal or lower S-Force centrifugal serial resistance can also be used. RET 97 TD yes ebm-papst St. Georgen offers the following capacitors ex stock: RER 120 TD yes 24 VDC: 1000 μF / 50 V, 16 mm x 25 mm RER 133 TD no Art. No.: 992 0345 000 (LZ 354) RER 160 NTDHH yes REF 175 TD no 48 VDC: 680 μF / 100 V, 18 mm x 40 mm RER 175 TD no Art. No. : 992 0355 000 (LZ 355) RER 190 TD / RG 190 TD no RER 220 TD / RG 220 no RER 225 TDM / RG 225 TDM no RER 225 TD / RG 225 TD yes 22 Information DC axial fans 4,5 m3/h max. Series 250 25 x 25 x 8 mm DC axial fans Highlights: – Compact fan with low power consumption. DC centrifugal fans 2 /2 -10...+55 35 000 / 12 000* 30 000 3 /2 /2 2,1 1,2 5 4,5...5,5 5 90 % PWM. Standstill at 0 % PWM, standstill if control cable is interrupted. The specific service life is valid when an external capacitor is wired between the plus and minus strands. Please note the wiring suggestion. AC centrifugal fans Accessories 243,2 1,5 0,5 7,0 + 0,3 0 100 200 200 400 300 400 600 500 800 600 1000 700 [CFM] 1200 [m3/h] NG T I PWM A HP 112 + 1,0 Û IP54 91 Representatives 100 0,25 200 0,75 1 300 1 1,25 400 350 +10 + 0,5 [Pa] [in H2O] 2,25 1,75 500 2 2 600 ,5 +0 530 6 +1 AC axial fans For suitable guard grilles, see page 176. DC centrifugal fans 220 m3/h max. Series RET 97 TD 97 Ø x 41 mm 8,1 72 48 36...60 8,1 72 Hours Hours 6 000 -20...+60 80 000 / 50 000 160 000 1 6 000 -20...+60 80 000 / 50 000 160 000 1 * Preliminary R16 Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, maximum speed at sensor break. To attain the specified service life, an external capacitor must be wired between the plus and minus strands. Please note the wiring suggestion on page. The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 116 x 116 mm. Cover plate 116 x 116 mm with an air inlet of Ø 80 mm, concentric to the impeller. Air flow 800 310 +10 [in H2O] Pa 2 mm 6 +1 Air flow 200 0,8 300 24,4 100 40,5 0 25 50 92 50 75 100 100 150 NG 125 200 CFM m³/h T I PWM A HP +1 M4 (4x) 400 1,6 500 7,95 + 1 97 ø 47,1 2,4 600 ø 58,3 1 700 Specials 16...36 °C Curve 129 24 RPM (40 °C) see P. 15 220 Watts Life expectancy L10Δ RET 97-25/18/2TDP / Service life L10 (Tmax) ebm-papst Standard NEW Bel(A) Service life L10 (40 °C) ebm-papst Standard 129 VDC Temperature range 220 VDC Nominal speed RET 97-25/14/2TDP* Power input NEW Sintec sleeve bearings Ball bearings CFM Sound power level m3/h Voltage range Air flow Type Nominal data Nominal voltage Air flow Highlights: – 3-phase fan drive with high degree of running smoothness. – Very high pressure build-up. – Forward curved impeller. – Available as standard with PWM control input and speed signal. Additional inputs and outputs on request. General characteristics: – Impeller of galvanised steel plate. – Fully integrated electronic commutation. – Direction of rotation: CW seen on rotor. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Mass: 430 g. RPM Information °C Hours Hours Specials Watts Curve / (40 °C) see P. 15 Bel(A) Life expectancy L10Δ Power input VDC Service life L10 (Tmax) ebm-papst Standard Sintec sleeve bearings Ball bearings VDC Service life L10 (40 °C) ebm-papst Standard Sound power level CFM Temperature range Voltage range m3/h Nominal speed Nominal voltage Type Air flow Nominal data Air flow Highlights: – Pressure-optimised blower. – Very flat and powerful centrifugal fan. – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. – Backward curved impeller. General characteristics: – Fibreglass-reinforced plastic scroll housing and impeller. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Direction of air flow radial, direction of rotation clockwise, seen on rotor. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Mass: 160 g P. 110 86 50,6 12 8...15 6,3 7,5 5 400 -20...+75 80 000 / 30 000 135 000 1 /2 REF 100-11/14 86 50,6 24 16...30 6,3 7,5 5 400 -20...+75 80 000 / 30 000 135 000 1 /2 86 50,6 48 36...60 6,3 7,5 5 400 -20...+75 80 000 / 30 000 135 000 1 /2 104 61,2 48 36...56 6,9 14,8 6 700 -20...+70 67 500 / 30 000 120 000 2 REF 100-11/18 REF 100-11/18 H ACmaxx / i-maxx REF 100-11/12 AC axial fans R 3,5 The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 127 x 127 mm. Cover plate 127 x 127 mm with an air inlet of Ø 70 mm, concentric to the impeller. Air flow DC axial fans 104 Ø x 25 mm DC centrifugal fans Series REF 100 DC fans - specials DC centrifugal fans 104 m3/h max. 2 mm AC centrifugal fans Air flow 24,9 +- 0,3 5,7 +- 0,3 2 Accessories 400 1,6 500 0,8 100 10 20 20 30 40 40 60 50 80 CFM 100 O 56 O 72 0 M 4 (3x) tief 66 deep 200 0,4 1,2 1 300 m³/h NG T I PWM A HP Û IP54 93 Representatives Pa [in H2O] 22,4 +- 0,4 DC centrifugal fans 190 m3/h max. Series RER 101 101 Ø x 52 mm Highlights: – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. – Backward curved impeller. 7,2 111,8 48 43...52 7,2 RER 101-36/18NHH 190 °C Hours Hours 5 900 -20...+70 60 000 / 30 000 120 000 1 20,0 5 900 -20...+70 60 000 / 30 000 120 000 1 19,0 5 900 -20...+70 60 000 / 30 000 120 000 1 R7 The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 148 x 148 mm. Cover plate 148 x 148 mm with an air inlet of Ø 66 mm, concentric to the impeller. Air flow Pa [in H2O] 1 mm Air flow 36,7 1 O 60 +- 0,2 1,5 400 1,0 300 M 4 (3x) 0,5 100 0 20 25 94 40 50 75 60 100 80 125 100 150 NG tief 10 deep 200 6,0 +- 0,2 7,0 +- 0,45 8,0 +- 0,55 50,25 +- 0,95 51,7 +- 0,9 CFM m³/h T I PWM A HP Specials 18..27,2 190 Curve 24 RER 101-36/14NHH (40 °C) see P. 15 111,8 111,8 Life expectancy L10Δ 20,5 190 Service life L10 (Tmax) ebm-papst Standard 7,2 RER 101-36/12NHH RPM Service life L10 (40 °C) ebm-papst Standard 9..13,6 CFM Temperature range 12 m3/h Nominal speed Power input Sound power level Bel(A) Air flow VDC Air flow Voltage range Watts Nominal voltage / VDC Type Nominal data Sintec sleeve bearings Ball bearings General characteristics: – Fibreglass-reinforced plastic scroll housing and impeller. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Direction of air flow radial, direction of rotation clockwise, seen on rotor. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Mass: 305 g. P. 116 /19 Information DC centrifugal fans Series RER 120 TD 120 Ø x 54 mm °C Hours DC axial fans DC centrifugal fans Hours NEW RER 120-26/14/2 TDMP* 320 188,2 24 16...32 tbd 51 5 200 -20...+60 60 000 / 37 500 120 000 1 NEW RER 120-26/14/2 TDP 377 221,9 24 16...32 8,2 78 6 100 -20...+60 55 000 / 35 000 110 000 2 NEW RER 120-26/18/2 TDMP* 320 188,2 48 36...60 tbd 51 5 200 -20...+60 57 500 / 35 000 115 000 1 NEW RER 120-26/18/2 TDP *Preliminary 390 229,5 48 36...60 8,3 92 6 300 -20...+60 50 000 / 30 000 100 000 3 ACmaxx / i-maxx RPM Specials Watts Curve / (40 °C) see P. 15 Bel(A) Life expectancy L10Δ Power input VDC Service life L10 (Tmax) ebm-papst Standard Sintec sleeve bearings Ball bearings VDC Service life L10 (40 °C) ebm-papst Standard Sound power level CFM Temperature range Voltage range m3/h Nominal speed Nominal voltage Type Air flow Nominal data Air flow Highlights: – 3-phase fan drive with high degree of running smoothness. – Very high pressure build-up. – Backward curved impeller. – Available as standard with PWM control input and speed signal. Additional inputs and outputs on request. General characteristics: – Impeller of fibreglass-reinforced plastic. – Fully integrated electronic commutation. – Direction of rotation: CW seen on rotor. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Mass: 430 g. The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 140 x 140 mm. Cover plate 140 x 140 mm with an air inlet of Ø 96 mm, concentric to the impeller. AC axial fans R16 Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, max. speed if control cable is interrupted. The specific service life is valid when an external capacitor is wired between the plus and minus strands. Please note the wiring suggestion. Air flow DC fans - specials 390 m3/h max. Pa 310 +10 [in H2O] 2 mm 6 +1 AC centrifugal fans Air flow 3 M4 (4x) max. max.88tief deep 1 0,8 300 13,5 + 1,5 100 26 0 50 100 100 150 200 200 300 54 +1 CFM m³/h NG T I PWM A HP 95 Representatives 200 Accessories 1,6 400 ø 58,3 ø47,1 2 500 ø120 +0,5 600 DC centrifugal fans 166 m3/h max. Series RER 125 N 138 Ø x 35 mm Highlights: – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. – Backward curved impeller. 24 12...28 5,7 97,7 24 12...28 7,0 64,7 48 36...56 5,7 5,0 110 RER 125-19/14 NH 166 RER 125-19/18 N 110 °C Hours Hours 2 650 -30...+75 62 500 / 27 500 125 000 1 4,5 2 650 -30...+75 62 500 / 27 500 125 000 1 13,0 4 000 -20...+70 55 000 / 27 500 110 000 2 2 650 -30...+75 62 500 / 27 500 125 000 1 4,5 P. 112 /12 R5 The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 220 x 220 mm. Cover plate 220 x 220 mm with an air inlet of Ø 86 mm, concentric to the impeller. Air flow M4 (2x) tief 55 deep ø125 150 2 35 + 0,5 30,7+ 0,3 19 ø56 ø47 0,8 Pa 200 0,6 [in H2O] 2 mm Air flow 4 4 20 25 96 40 50 60 75 100 6 +1 0 400 +10 0,4 50 0,2 1 100 80 CFM 125 m³/h NG T I PWM A HP Specials 64,7 RER 125-19/14 N Curve 5,7 64,7 (40 °C) see P. 15 7...15 110 Life expectancy L10Δ 12 RER 125-19/12 N RPM Service life L10 (Tmax) ebm-papst Standard Power input Watts CFM Service life L10 (40 °C) ebm-papst Standard Sintec sleeve bearings Ball bearings / m3/h Temperature range Sound power level Bel(A) Type Nominal data Nominal speed Voltage range VDC Air flow VDC Air flow Nominal voltage General characteristics: – Fibreglass-reinforced plastic scroll housing and impeller. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Direction of air flow radial, direction of rotation clockwise, seen on rotor. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Mass: 320 g. Information DC centrifugal fans Series RER 133 TD 133 Ø x 91 mm DC axial fans DC centrifugal fans °C Hours Hours NEW RER 133-41/14/2 TDMP 460 270,6 24 16...30 tbd 53 5 000 -20...+65 72 500 / 40 000 145 000 1 NEW RER 133-41/14/2 TDP* 565 332,4 24 16...36 tbd 90 6 000 -20...+65 70 000 / 37 500 140 000 2 NEW RER 133-41/18/2 TDMP* 460 270,6 48 36...57 tbd 50 5 000 -20...+65 72 500 / 40 000 145 000 1 NEW RER 133-41/18/2 TDP 565 332,4 48 36...72 8,2 87 6 000 -20...+65 70 000 / 37 500 140 000 2 ACmaxx / i-maxx RPM Specials Watts Curve / (40 °C) see P. 15 Bel(A) Life expectancy L10Δ Power input VDC Service life L10 (Tmax) ebm-papst Standard Sintec sleeve bearings Ball bearings VDC Service life L10 (40 °C) ebm-papst Standard Sound power level CFM Temperature range Voltage range m3/h Nominal speed Nominal voltage Type Air flow Nominal data Air flow Highlights: – 3-phase fan drive with high degree of running smoothness. – Very high pressure build-up. – Backward curved impeller. – Available as standard with PWM control input and speed signal. Additional inputs and outputs on request. General characteristics: – Impeller of fibreglass-reinforced plastic. – Fully integrated electronic commutation. – Direction of rotation: CW seen on rotor. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Mass: 890 g. *Preliminary The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 140 x 140 mm. Cover plate 140 x 140 mm with an air inlet of Ø 87 mm, concentric to the impeller. AC axial fans R7 Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, max. speed if control cable is interrupted. Air flow DC fans - specials 565 m3/h max. 41 50 100 100 200 150 200 300 250 400 300 CFM 500 m³/h NG T I PWM A AC centrifugal fans Accessories 30,4 + 1,5 +1 HP 97 Representatives 91 0 ø133 +0,5 1,6 200 M4 (4x) max. max.8 8tief deep 400 0,8 1 ø 72 +0,3 425 +10 ø58 + 0,1 Pa 6 +1 2 2,4 600 [in H2O] 2 mm Air flow DC centrifugal fans 255 m3/h max. Series RER 160 N 165 Ø x 51 mm Highlights: – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. – Backward curved impeller. RER 160-28/18 N 255 °C Hours Hours 3 000 -20...+70 75 000 / 35 000 140 000 1 19,0 3 000 -20...+70 75 000 / 35 000 140 000 1 19,0 3 000 -20...+70 75 000 / 35 000 140 000 1 R5 The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 260 x 260 mm. Cover plate 260 x 260 mm with an air inlet of Ø 100 mm, concentric to the impeller. Air flow 425 +10 ø58 + 0,1 ø 72 +0,3 ø160 +0,5 max. max.8 8deep tief 0,4 50 M4 (4x) Pa 6 +1 0,8 100 0,2 150 1 0,6 200 [in H2O] 2 mm Air flow 6,1+ 0,8 50,3 +0,7 0 20 40 50 98 60 100 80 100 150 NG 120 200 CFM m³/h T I PWM A HP Û S P IP54 Specials 255 Curve 48 Air flow 150,1 Air flow 24 RER 160-28/14 N (40 °C) see P. 15 6,4 150,1 150,1 Life expectancy L10Δ 28...60 7...14 255 Service life L10 (Tmax) ebm-papst Standard 6,4 12 RER 160-28/12 N Service life L10 (40 °C) ebm-papst Standard 12...28 Bel(A) CFM Temperature range 19,0 VDC m3/h Nominal speed Power input 6,4 Sound power level RPM Voltage range Watts Nominal voltage / VDC Type Nominal data Sintec sleeve bearings Ball bearings General characteristics: – Fibreglass-reinforced plastic scroll housing and impeller. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Direction of air flow radial, direction of rotation clockwise, seen on rotor. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Mass: 590 g. P. 112 /12 /12 Information DC centrifugal fans Series RER 160 NTD 165 Ø x 51 mm DC axial fans Highlights: – Control inputs, alarm and speed signals available on request. – 3-phase fan drive with high degree of running smoothness. – High pressure build-up. – Backward curved impeller. 98,3 48 36...60 8,5 142 48 38...57 Hours 4 200 -20...+60 55 000 / 27 500 110 000 2 6 000 -20...+65 40 000 / 22 500 80 000 3 -20...+70 55 000 / 27 500 110 000 — 2,0 800 7,4 43,0 4 200 DC centrifugal fans 51 Hours P. 1 ACmaxx / i-maxx 18,3 RER 160-28/18 NTD... 7,4 °C Specials 66 354 2 Model RER 160-28/18 NTD... is available in customer-specific, custom-developed variant only. The data specified here are technically feasible benchmark values. The fans can be specially adapted to your application with signal outputs and control inputs. *The specific service life is valid when an external capacitor is wired between the plus and minus strands. Please note the wiring suggestion. AC axial fans R5 The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 260 x 260 mm. Cover plate 260 x 260 mm with an air inlet of Ø 100 mm, concentric to the impeller. Air flow 425 +10 1,6 200 AC centrifugal fans 6 +1 Pa 400 0,8 Pa [in H2O] 3,2 800 600 3 2,4 2 mm 1000 4,0 [in H2O] Air flow 2 100 1,6 100 150 200 200 300 250 400 CFM m³/h max. max.88deep tief 6,1+ 0,8 1 n min 0 n max 50 50 50,3 +0,7 100 100 150 200 150 CFM 250 m³/h NG T I PWM A HP 99 Representatives 100 M4 (4x) 1,2 200 0,8 300 50 Accessories 0 400 ø58 + 0,1 ø 72 +0,3 ø160 +0,5 500 0,4 min. max. 16...28 Curve 297,5 24 RPM (40 °C) see P. 15 505 Watts Life expectancy L10Δ RER 160-28/18N/2TDHHP* / Service life L10 (Tmax) ebm-papst Standard NEW Bel(A) Service life L10 (40 °C) ebm-papst Standard 217 VDC Temperature range 370 VDC Nominal speed RER 160-28/14N/2TDA Power input NEW Sintec sleeve bearings Ball bearings CFM Sound power level m3/h Voltage range Air flow Type Nominal data Nominal voltage Air flow General characteristics: – Fibreglass-reinforced plastic scroll housing and impeller; Housing base of steel plate. – Fully integrated electronic commutation. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Mass: 590 g. DC fans - specials 505 m3/h max. DC centrifugal fans 800 m3/h max. Series REF 175 TD 175 Ø x 55 mm 48 36 ... 72 8,3 121 4 400 Specials 470 Curve 800 RPM (40 °C) see P. 15 REF 175-30/18/2TDP Watts °C Hours Hours -20...+60 65 000 / 37 500 130 000 1 R10 Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, max. speed if control cable is interrupted. The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 180 x 180 mm. Cover plate 180 x 180 mm with an air inlet of Ø 125,5 mm, concentric to the impeller. Air flow Pa 425 +10 [in H2O] 2 mm 6 +1 Air flow 1 max. tief max.8 8deep M4 (4x) 300 200 6,8 + 0,8 30 100 54,3 + 1 0 100 200 100 200 300 400 400 600 NG 500 800 CFM m³/h T I PWM A HP ø175 + 1,0 400 1,6 500 ø72 + 0,3 ø58 + 0,1 600 0,8 NEW / Life expectancy L10Δ Bel(A) Service life L10 (Tmax) ebm-papst Standard VDC Service life L10 (40 °C) ebm-papst Standard Sound power level VDC Temperature range Voltage range CFM Nominal speed Nominal voltage m3/h Power input Air flow Type Nominal data Sintec sleeve bearings Ball bearings Air flow Highlights: – 3-phase fan drive with high degree of running smoothness. – Very high pressure build-up. Backward curved impeller. – Available as standard with PWM control input and speed signal. Additional inputs and outputs on request. General characteristics: – Impeller of galvanised steel plate. – Fully integrated electronic commutation. – Direction of rotation: CW seen on rotor. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 20, TR 64, speed signal and control input AWG 22, bared and tin-plated. – Mass: 930 g. Information DC centrifugal fans Series RER 175 TD 175 Ø x 69 mm RPM °C Hours Hours DC axial fans DC centrifugal fans RER 175-42/14/2 TDMLP 600 353,0 24 16...30 7,3 45 3 400 -20...+65 72 500 / 45 000 145 000 1 NEW RER 175-42/14/2 TDMP 865 508,8 24 16...36 8,2 110 4 800 -20...+65 70 000 / 40 000 140 000 2 NEW RER 175-42/18/2 TDMLP 600 353,0 48 36...57 7,3 46 3 400 -20...+65 72 500 / 45 000 145 000 1 NEW RER 175-42/18/2 TDMP* 865 508,8 48 36...72 8,2 110 4 800 -20...+65 70 000 / 40 000 140 000 2 NEW RER 175-42/18/2 TDP 980 576,8 48 36...72 8,5 166 5 400 -20...+65 60 000 / 32 500 115 000 3 * preliminary data Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, max. speed if control cable is interrupted. The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 180 x 180 mm. Cover plate 180 x 180 mm with an air inlet of Ø 125,5 mm, concentric to the impeller. Air flow AC axial fans R10 NEW ACmaxx / i-maxx Watts Specials / Curve Power input Bel(A) (40 °C) see P. 15 Sintec sleeve bearings Ball bearings VDC Life expectancy L10Δ Sound power level VDC Service life L10 (Tmax) ebm-papst Standard Voltage range CFM Service life L10 (40 °C) ebm-papst Standard Nominal voltage Type Temperature range Air flow m3/h Nominal data Nominal speed Air flow Highlights: – 3-phase fan drive with high degree of running smoothness. – Very high pressure build-up. Backward curved impeller. – Available as standard with PWM control input and speed signal. Additional inputs and outputs on request. General characteristics: – Impeller of fibreglass-reinforced plastic. – Fully integrated electronic commutation. – Direction of rotation: CW seen on rotor. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 18, 20 or AWG 22, TR 64, speed signal and control input AWG 22, bared and tin-plated. – Mass: 775 g. DC fans - specials 980 m3/h max. 6 +1 425 +10 3 max. max.8 8deep tief M4 (4x) 200 0,8 1 6,8+ 0,8 42 0 100 200 200 400 300 400 600 500 800 69 ±1 CFM m³/h NG T I PWM A HP Û S P IP54 101 Representatives 2,4 400 1,6 2 600 Accessories ø58 + 0,1 ø 72 +0,3 ø175 +0,5 3,2 2 mm Pa [in H2O] 800 AC centrifugal fans Air flow DC centrifugal fans 970 m3/h max. Series RER 190 TD 190 Ø x 69 mm RPM °C Hours Hours NEW RER 190-39/14/2TDMLO 650 382,4 24 16...30 7,6 58 3 000 -20...+60 55 000 / 35 000 110 000 1 NEW RER 190-39/14/2TDMO 860 505,9 24 16...36 7,9 110 3 900 -20...+65 52 500 / 30 000 105 000 2 NEW RER 190-39/18/2TDMLO 650 382,4 48 36...57 7,6 56 3 000 -20...+65 55 000 / 35 000 110 000 1 NEW RER 190-39/18/2TDMO 860 505,9 48 36...72 7,9 105 3 900 -20...+65 52 500 / 30 000 105 000 2 NEW RER 190-39/18/2TDO 970 570,6 48 36...72 8,3 148 4 400 -20...+65 40 000 / 22 500 80 000 3 Specials Curve Watts (40 °C) see P. 15 / Life expectancy L10Δ Bel(A) Service life L10 (Tmax) ebm-papst Standard VDC Service life L10 (40 °C) ebm-papst Standard Sound power level VDC Temperature range Voltage range CFM Nominal speed Nominal voltage Type Power input Air flow m3/h Nominal data Sintec sleeve bearings Ball bearings Air flow Highlights: – 3-phase fan drive with high degree of running smoothness. – Very high pressure build-up. – Backward curved RadiCal impeller with maximum efficiency. – Standard models available with multifunctional control input for analogue, PWM and speed signal. General characteristics: – Impeller of fibreglass-reinforced plastic. – Fully integrated electronic commutation. – Direction of rotation: CW seen on rotor. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 18, 20 or AWG 22, TR 64, speed signal and control input AWG 22, bared and tin-plated. – Mass: 870 g. R10 Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, standstill if control cable is interrupted. The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 195 x 195 mm. Cover plate 195 x 195 mm with an air inlet of Ø 125,5 mm, concentric to the impeller. Air flow +10 3 425 [Pa] 900 3,5 [in H2O] 6 +1 2 mm Air flow 58 max. 88 deep tief max. 1 300 200 39 0,5 100 6,5 +1 0 100 200 102 200 400 300 400 600 500 800 NG 600 1000 69 [CFM] 3 [m /h] T I PWM A HP Û S P IP54 +1 190 + 0,1 1,5 1 M4 (4x) 400 2 500 1,5 600 72 +0,3 2 700 + 0,3 3 800 Watts NEW RER 220-44/14/2TDMO 1090 641,2 24 16...36 7,7 NEW RER 220-44/18/2TDMO 1090 641,2 48 36...72 NEW RER 220-44/18/2TDO 1280 752,9 48 36...72 RPM Information Specials / Curve Power input Bel(A) (40 °C) see P. 15 Sintec sleeve bearings Ball bearings VDC Life expectancy L10Δ Sound power level VDC Service life L10 (Tmax) ebm-papst Standard Voltage range CFM Service life L10 (40 °C) ebm-papst Standard Nominal voltage m3/h Temperature range Air flow Type °C Hours Hours 82 3 000 -20...+55 75 000 / 52 500 150 000 1 7,7 80 3 000 -20...+55 75 000 / 52 500 150 000 1 8,0 140 3 500 -20...+55 55 000 / 40 000 110 000 2 ACmaxx / i-maxx Nominal data Nominal speed Air flow Highlights: – 3-phase fan drive with high degree of running smoothness. – Very high pressure build-up. – Backward curved impeller. – Standard models available with multifunctional control input for analogue, PWM and speed sign. General characteristics: – Impeller of fibreglass-reinforced plastic. – Fully integrated electronic commutation. – Direction of rotation: CW seen on rotor. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 18, 20 or AWG 22, TR 64, speed signal and control input AWG 22, bared and tin-plated. – Mass: 940 g. The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 230 x 230 mm. Cover plate 230 x 230 mm with an air inlet of Ø 146 mm, concentric to the impeller. AC axial fans R10 Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, standstill if control cable is interrupted. Air flow AC centrifugal fans 6 +1 + 10 2 425 2,25 600 Accessories + 0,5 ø 220,9 M4 (4x) max. max.88deep tief ø 72 + 0,3 1,5 44,0 0,5 100 7,2 + 1,5 0,25 200 0,75 1 300 1,25 400 ø 58 1,75 + 0,1 2 1 0 100 200 200 400 300 400 600 500 800 600 1000 700 [CFM] 1200 3 71+ 1 [m /h] NG T I PWM A HP Û IP54 103 Representatives [Pa] [in H2O] 2 mm Air flow 500 DC axial fans 221 Ø x 71 mm DC centrifugal fans Series RER 220 TD DC fans - specials DC centrifugal fans 1280 m3/h max. DC centrifugal fans 1600 m3/h max. Series RER 225 TD 225 Ø x 99 mm RER 225-55/18/2TDMLO 1080 635,4 48 36...72 7,5 82 NEW RER 225-55/18/2TDMO 1210 711,9 48 36...72 7,9 120 NEW RER 225-63/18/2TDP-402 1600 941,3 48 36...72 8,1 165 Specials NEW RPM Curve Bel(A) (40 °C) see P. 15 VDC Life expectancy L10Δ VDC Service life L10 (Tmax) ebm-papst Standard CFM Service life L10 (40 °C) ebm-papst Standard m3/h Temperature range Sound power level Type Nominal data Nominal speed Voltage range Power input Nominal voltage Watts Air flow / Air flow Sintec sleeve bearings Ball bearings Highlights: – 3-phase fan drive with high degree of running smoothness. – Very high pressure build-up. – TDM and TDML model with backward-curved RadiCal impeller with maximum efficiency. – Standard models available with multifunctional control input for analogue, PWM and speed signal. General characteristics: – Impeller of fibreglass-reinforced plastic. – Fully integrated electronic commutation. – Direction of rotation: CW seen on rotor. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 18, 20 or AWG 22, TR 64, speed signal and control input AWG 22, bared and tin-plated. – Mass: 1030 g. °C Hours Hours 2 500 -20...+55 70 000 / 50 000 140 000 1 2 800 -20...+55 55 000 / 40 000 110 000 2 3 300 -20...+55 52 500 / 37 500 105 000 3 6 +1 Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0% PWM, Type O: standstill at sensor break. Type P: maximum speed at sensor break. Air flow 425 +10 2 100 55 10,6 + 1,5 0 100 200 104 200 400 300 400 600 500 600 700 800 800 1000 1200 1400 NG 900 99 [CFM] [m3/h] T I PWM A HP Û IP54 +1 ø 225 + 0,5 ø 72 +0,3 M4 (4x) max. 8 tief max. deep ø 58 + 0,1 1 0,25 0,5 0,75 200 0,5 6 +1 3 1 300 2,75 [in H2O] 2 mm 400 99 + 1 Type RER 225-55 2,25 2,5 [Pa] 500 8,6 + 0,8 62,0 2 600 1,25 1,5 1,75 700 max. ø225 max.8 8deep tief max. ø58 M4 (4x) Air flow ø72 + 0,3 425 +10 The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 230 x 230 mm. Cover plate 230 x 230 mm with an air inlet of Ø 146 mm, concentric to the impeller. + 0,1 R10 Type RER 225-63 Information DC tangential fan Series QG 030 201...413 x 50 x 48 mm DC axial fans Highlights: – Tangential fans with high air flow. – Large air outlet. Hours DC centrifugal fans °C Hours 75 44,1 12 8...14 49 5,7 / 6,2 -20...+60 30 000 / 10 000 32 500 1 QG 030-198/12 100 58,9 12 8...14 51 5,8 / 8,0 -20...+60 30 000 / 10 000 32 500 2 QG 030-303/12 140 82,4 12 8...14 51 5,8 / 8,7 -20...+60 30 000 / 10 000 32 500 3 QG 030-353/12 155 91,3 12 8...14 51 5,9 / 9,6 -20...+60 30 000 / 10 000 32 500 4 QG 030-148/14 75 44,1 24 16...28 49 5,7 / 6,2 -20...+60 30 000 / 10 000 32 500 1 QG 030-198/14 100 58,9 24 16...28 51 5,8 / 8,0 -20...+60 30 000 / 10 000 32 500 2 QG 030-303/14 140 82,4 24 16...28 51 5,8 / 8,7 -20...+60 30 000 / 10 000 32 500 3 QG 030-353/14 155 91,3 24 16...28 51 5,9 / 9,6 -20...+60 30 000 / 10 000 32 500 4 Tangential fans are only suitable for operation with high rate and low back pressure. L L1 QG 030-148/ .. Type Dimension: 201 +1,5 148 QG 030-198/ .. 258 +1,5 198 QG 030-303/ .. 363 +1,5 303 QG 030-353/ .. 413 +1,5 353 AC axial fans QG 030-148/12 ACmaxx / i-maxx Watts Specials / (40 °C) see P. 15 Bel(A) Curve Life expectancy L10Δ db(A) Service life L10 (Tmax) ebm-papst Standard VDC Service life L10 (40 °C) ebm-papst Standard Sound pressure level VDC Temperature range Voltage range CFM Power input Nominal voltage Type Sleeve bearings Ball bearings Air flow m3/h Nominal data Sound power level Air flow General characteristics: – Motor with ball bearing system. Impeller mounting plate with sleeve bearings. – Fan housing and impeller of aluminium. Plastic housing side parts. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Air exhaust out of the outlet. – Connection via single strands. Bared and tin-plated. – Mass: 235 / 290 / 380 / 415 g. DC fans - specials 155 m3/h max. AC centrifugal fans The service life values refer to horizontal installation of the fan. 12 [in H2O] 6 50 10 15 20 30 40 2 45 60 80 3 60 100 75 120 4 CFM 16,5 21,5 10 34,4 5,4 ±0,7 L Cut-out square nut M3 562-flat DIN 562, Cutout forfor squarenut M3 DIN (6x)flat (6x) m³/h HP 105 Representatives 1 Ø35,1 Ø41 +0,3 3,2 Accessories Ø9 0,05 20 0 L1 47,5 0,10 30 10 10 Ø2,3 (8x) 0,15 40 38,4 300 ±10 Pa 50 106 Information Alarm signal 114 Vario-Pro / Speed setting / Control input 119 Protection against ambient influences 123 DC axial fans 110 107 Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / i-maxx DC fans - specials Sensor signal DC centrifugal fans DC fans - specials DC fans - specials Technical information Cooling capacity and efficiency Greater power density, increasing miniaturisation and extreme electronic component density are posing increased demands on the cooling capacity and efficiency of fans. The intelligent and space-saving integration of the fan in the device configuration is therefore of major importance: • Tailor-made cooling adapted to the situation as and when required. • Programmable cooling by defining speed profiles. • Transparency of function thanks to complete, interactive monitoring in all operating conditions. ebm-papst provides intelligent cooling concepts which are optimally adapted to requirements. For example: 1. Speed adaptation via NTC sensor Standard fans in electronics cooling– tried and tested by the millions and nevertheless a temporary solution, because standard fans have a distinct disadvantage: With constant speed and a corresponding high noise factor, they continuously provide the air flow required in extreme cases. This extreme case only occurs-, if it occurs at all-, for a fraction of the service life. What is needed is an intelligent fan that automatically adapts to the current cooling requirements. 108 The ebm-papst answer: A complete range of DC fans with temperature-controlled speed adaptation - in all standard dimensions. Installation is simple. The control electronics receive their thermal information for speed adaptation steplessly and loss-free via a temperature sensor either externally via a single lead, positioned as required, or internally directly in the fan hub in the air flow. 2. DC fans with separate control input Open or closed-loop speed control is also possible with DC fans that have a separate control input. A variation in speed can thus be implemented via a control voltage or a pulse-width modulated signal. These possibilities are used primarily in devices that have appropriate standard interfaces and thus require a load-dependent variation of the fans. Information DC axial fans DC fans - specials DC centrifugal fans A Technical information DC fans - specials ACmaxx / i-maxx AC axial fans 5. Turbo drives Fans with three-phase EC drives and microprocessor-controlled motor electronics. These three-phase motors whose torque is virtually non-reliant on the rotor position are used for extremely high running smoothness. The speed of these fans can be controlled over a very wide range with PWM, analogue voltage or temperature. Optionally, the fans can be supplied with reversible direction of rotation and active brake operation. The successful concept of Vario-Pro is: Tailor-made software instead of fixed hardware, because programmed software modules for motor control and application intelligence are responsible for the work that analogue components were responsible for in the past. This central control unit of the Vario-Pro comprises a microcontroller and an EEPROM, on which all characteristics are stored. 7. Protection against environmental influences Some applications place particular demands on the fans' resistance to ambient influences, such as dust, moisture, water and salt. ebm-papst offer solutions for adapting fans to these ambient conditions. AC centrifugal fans 4. Alarm signal For applications which require monitored fan operation with alarm signal, ebm-papst has numerous alarm signal versions, either a static, pre-processed or interface-compatible high or low continuous signal depending on the type of fan. 6. Vario-Pro fans This high-end fan concept by ebmpapst with programmed intelligence and customer-specific integrated functions makes your electronics cooling even more versatile and competitive. Vario-Pro ensures a fresh economic breeze for all demanding cooling tasks – e.g. where greater reliability, more flexibility and intelligent function features such as alarm function, speed control etc. are required. Accessories 3. Sensor signal DC fans with sensor signal. The integrated „electronic tachometer“ continuously provides an actual speed signal for external evaluation. The user is informed at all times of the current fan speed via an extremely simple signal evaluation on the customer side. The sensor signal is via a separate lead. 109 Representatives PWM Speed signal /2 Speed-proportional rectangular pulse for external speed monitoring of fan motor. 2, 3 or 6 pulses per revolution. Open collector signal output. Extremely wide operating voltage range. Easy adaptation to user interface. Connection via separate lead. The sensor signal also serves as a major comparison variable for setting and maintaining the setpoint speed for interactive or controlled cooling with one or several interconnected fans. Condition: Isource VDC mA VDC mA VDC ≤ 0,4 ≤2 30 0 ≤ 30 2 2 23 400 F ≤ 0,4 1 30 0 ≤ 30 ≤2 2 24 400 ≤ 0,4 1 30 0 ≤ 30 ≤2 2 25 400 J ≤ 0,4 2 30 0 ≤ 30 ≤4 2 26 Signal output voltage 500 F ≤ 0,4 1 30 0 ≤ 30 ≤2 2 27 Standard signal for all models (exceptions see below) 600 F ≤ 0,4 1 30 0 ≤ 30 ≤2 2 28 UB UB +UBS output Isink US (-) Power All voltages measured to ground. External load resistor Ra / US / UBS required. mA Page 620 ≤ 0,4 2 30 0 ≤ 30 ≤4 2 29 630 U ≤ 0,4 2 30 0 ≤ 30 ≤4 2 30 600 N ≤ 0,4 2 28 0 ≤ 28 ≤4 2 31 600 J ≤ 0,4 2 30 0 ≤ 30 ≤4 2 33 700 F ≤ 0,4 2 30 0 ≤ 30 ≤4 2 34 8450 ≤ 0,4 2 28 0 ≤ 28 ≤4 2 35 8400 N ≤ 0,4 2 28 0 ≤ 28 ≤4 2 36 8400 N VARIOFAN ≤ 0,4 2 30 0 ≤ 30 ≤4 2 37 8300 ≤ 0,4 2 30 0 ≤ 30 ≤4 2 38 8200 J ≤ 0,4 2 30 0 ≤ 30 ≤4 2 39 3400 N ≤ 0,4 2 28 0 ≤ 28 ≤4 2 40 3400 N VARIOFAN ≤ 0,4 2 30 0 ≤ 30 ≤4 2 41 3300 ≤ 0,4 2 30 0 ≤ 30 ≤4 2 42 3 Pulse / Rotation 3212 J / 3214 J ≤ 0,4 2 30 0 ≤ 30 ≤4 2 43 Signal frequenzy [F]= 3 x n/60 Hz 3218 J ≤ 0,4 2 60 0 ≤ 60 ≤4 2 43 4412 F / 4414 F ≤ 0,4 2 30 0 ≤ 30 ≤4 2 44 4418 F ≤ 0,4 2 60 0 ≤ 60 ≤4 2 44 4400 FN ≤ 0,4 2 30 0 ≤ 30 ≤4 2 45 4312 / 4314 ≤ 0,4 2 30 0 ≤ 30 ≤4 2 46 4318 U S High Us s U S Low t1 t t2 1 Rotation 2 Pulse / Rotation Signal frequenzy [F]= 2 x n/60 Hz only for 4100 NH7 and NH8 U S High Us U S Low t1 t t2 1 Rotation All TD NTD, fans. Ex.: 6400 6200 6400 TD,TD DV 6200 TD, DV 6400 TD, RER / RG 160 NTD U S High Us U S Low t1 t t2 1 Rotation 6 Pulse / Rotation Signal frequenzy [F]= 6 x n/60 Hz Fa n Speed n nmin 110 Signal data Fan description Speed signal US High Type 250 (+) Power Sensor operating voltage UBS Condition: Isink Customer Speed signal US Low Fan Perm. sink current Isink max. Electrical connection Pulses per revolution – – – – – – – nmax t ≤ 0,4 2 60 0 ≤ 60 ≤4 2 46 4312 / 4314 VARIOFAN ≤ 0,4 2 30 0 ≤ 30 ≤4 2 47 4318 VARIOFAN ≤ 0,4 2 60 0 ≤ 60 ≤4 2 47 4400 ≤ 0,4 2 30 0 ≤ 30 ≤4 2 48 4100 N ≤ 0,4 2 30 0 ≤ 30 ≤4 2 49 4100 NHH...NH6 ≤ 0,4 2 ≤ 60 0 ≤ 60 ≤ 10 2 50 4100 NH7...NH8 ≤ 0,4 2 ≤ 60 0 ≤ 60 ≤ 20 3 51 DV 4100 ≤ 0,4 2 30 0 ≤ 30 ≤4 2 52 5200 N ≤ 0,4 2 30 0 ≤ 30 ≤4 2 53 Information DC centrifugal fans Perm. sink current Isink max. ≤ 30 ≤4 2 54 0 ≤5 ≤ 20 2 55 60 0 ≤ 60 ≤ 20 2 55 ≤ 72 0 ≤ 72 ≤4 2 56 2 72 0 ≤ 72 ≤ 20 6 57 ≤ 0,4 2 60 0 ≤ 60 ≤ 20 2 58 7114 N ≤ 0,4 2 30 0 ≤ 30 ≤ 20 2 58 7200 N ≤ 0,4 2 15 0 ≤ 15 ≤ 20 2 59 6300 ≤ 0,4 2 ≤ 72 0 ≤ 72 ≤ 20 2 61 6300 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 62 DV 6200 ≤ 0,4 2 30 0 ≤ 60 ≤ 20 2 64 6400 ≤ 0,4 2 60 0 ≤ 60 ≤ 20 2 66 2200 FTD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 70 RL 48 ≤ 0,4 2 3 0 ≤ 30 ≤4 2 81 RL 65 ≤ 0,4 2 30 0 ≤ 30 ≤4 2 82 RL 90 N ≤ 0,4 2 30 0 ≤ 30 ≤4 2 83 RLF 100 ≤ 0,4 2 30 0 ≤ 30 ≤4 2 84 RG 90 N ≤ 0,4 2 30 0 ≤ 30 ≤4 2 85 RG 125 N ≤ 0,4 2 30 0 ≤ 30 ≤4 2 86 RG 160 N ≤ 0,4 2 30 0 ≤ 30 ≤ 20 2 87 RG 160 TD ≤ 0,4 2 60 0 ≤ 60 ≤ 20 6 88 RG 190 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 89 RG 220 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 90 RG 225 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 91 RET 97 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 92 REF 100 ≤ 0,4 2 30 0 ≤ 30 ≤4 2 93 RER 120 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 95 RER 133 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 97 RER 160 TD ≤ 0,4 2 60 0 ≤ 60 ≤ 20 6 99 REF 175 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 100 RER 175 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 101 RER 190 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 102 RER 220 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 103 RER 225 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 104 ≤ 0,4 2 15 5114 N / 5118 N ≤ 0,4 2 5300 ≤ 0,4 2 5300 TD ≤ 0,4 7112 N / 7118 N DC fans - specials 5112 N Page ACmaxx / i-maxx 30 AC axial fans 2 AC centrifugal fans mA ≤ 0,4 Accessories VDC Attention: With these fan options, deviations in regard to temperature range, voltage range and power consumption are possible compared with standard fan data. 111 Representatives Sensor operating voltage UBS mA 0 Type DV 5200 Signal data Fan description Condition: Isource mA VDC Condition: Isink VDC Speed signal US Low Speed signal US High Pulses per revolution DC axial fans Available on request: – Electrically isolated sensor and signal circuit. – Varying voltage potentials for power and logic circuit. Speed signal /12 – – – – – – Speed-proportional rectangular pulse for external speed monitoring of fan motor. 2, 3 or 6 pulses per revolution. TTL-compatible. Integrated pull-up resistor. Connection via separate lead. The sensor signal also serves as a major comparison variable for setting and maintaining. the setpoint speed for interactive or controlled cooling with one or more interconnected fans. Electrical connection mA mA Page 1 2,5–5,5 1 1 31 1 2,5–5,5 1 1 31 ≤ 0,4 1 2,5–5,5 1 1 36 4412 F/12 GM ≤ 0,4 1 2,5–5,5 1 1 44 4418 F/12 ≤ 0,4 1 2,5–5,5 1 1 44 4312 /12 M ≤ 0,4 1 2,5–5,5 1 1 46 4314 /12 ≤ 0,4 1 2,5–5,5 1 1 46 4182 N/12 X ≤ 0,4 1 2,5–5,5 1 1 49 Signal data Speed signal US Low Type VDC mA 614 N/12 GM ≤ 0,4 618 N/12 N ≤ 0,4 8412 N/12 H UB output US (-) Power All voltages measured to ground. Signal output voltage Standard signal for all models (exceptions see below) U S High Us s U S Low t1 t t2 Fan description Perm. sink current Isink max. VDC (+) Power Speed signal US High Condition: Isource Customer Condition: Isink Fan 1 Rotation 2 Pulse / Rotation Attention: With these fan options, deviations in regard to temperature range, voltage range and power consumption are possible compared with standard fan data.. Signal frequenzy [F]= 2 x n/60 Hz only for 4100 NH7 and NH8 U S High Us U S Low t1 t t2 1 Rotation 3 Pulse / Rotation Signal frequenzy [F]= 3 x n/60 Hz All TD NTD, fans. Ex.: 6400 6200 6400 TD,TD DV 6200 TD, DV 6400 TD, RER / RG 160 NTD U S High Us U S Low t1 t t2 1 Rotation 6 Pulse / Rotation Signal frequenzy [F]= 6 x n/60 Hz Fa n Speed n nmin 112 nmax t Information mA Page 2 2,5–5,5 1 ≤ 20 59 ≤ 0,4 2 4,5–5,25 2 ≤ 12 64 6424 /12 H ≤ 0,4 2 2,5–5,5 1 ≤ 20 66 DV 6424 /12 ≤ 0,4 2 4,5–5,25 2 ≤ 12 68 DV 6448 /12 ≤ 0,4 2 4,5–5,25 2 ≤ 12 68 RG 125-19/12N/12 ≤ 0,4 1 2,5–5,5 1 ≤1 86 RG 160-28/12N/12 ≤ 0,4 2 2,5–5,5 1 ≤5 87 RG 160-28/18N/12 ≤ 0,4 2 2,5–5,5 1 ≤ 20 87 RER 125-19/12N/12 ≤ 0,4 1 2,5–5,5 1 ≤1 96 RER 160-28/12N/12 ≤ 0,4 2 2,5–5,5 1 ≤5 98 RER 160-28/18N/12 ≤ 0,4 2 2,5–5,5 1 ≤ 20 98 7214 N/12 ≤ 0,4 DV 6224 /12 DC fans - specials mA ACmaxx / i-maxx VDC AC axial fans Speed signal US Low Type Fan description Perm. sink current Isink max. mA Signal data Speed signal US High VDC Condition: Isink Condition: Isource DC centrifugal fans DC axial fans Available on request: – Electrically isolated sensor and signal circuit. – Varying voltage potentials for power and logic circuit. 113 Representatives Accessories AC centrifugal fans Attention: With these fan options, deviations in regard to temperature range, voltage range and power consumption are possible compared with standard fan data. Alarm signal /17 0 ≤ 60 20 ≤ 15 * 1500 ± 100 38 60 n > nG 0 ≤ 60 20 ≤ 15 * 1500 ± 100 38 2 60 n > nG 0 ≤ 60 20 ≤ 15 * 1500 ± 100 42 n < nG 2 60 n > nG 0 ≤ 60 20 ≤ 15 * 1500 ± 100 42 ≤ 0,4 n < nG 2 60 n > nG 0 ≤ 60 20 ≤ 15 * 850 ± 100 46 ≤ 0,4 n < nG 2 60 n > nG 0 ≤ 60 20 ≤ 15 * 1500 ± 100 49 ≤ 0,4 n < nG 2 3314 /17 ≤ 0,4 n < nG 3318 /17 H ≤ 0,4 4318 /17 4184 N /17 X ≤ 0,4 8318 /17 H Condition: 60 Alarm output voltage UA Low 2 8318 /17 min –1 Fan description Alarm delay time t2 n > nG n < nG VDC Speed limit nG Max. permissible Sink current S VDC Type Condition: Alarm operatingvoltage UBA max. mA mA Alarm signal data Condition: VDC Alarm outputvoltage UA High mA Condition: Isink = Condition: Isource – Alarm signal for speed monitoring. – Signal output via open collector. – The fan emits a high continuous signal during trouble-free operation within the permissible voltage range. – Low signal when speed limit is not reached. – After elimination of fault, the fan returns to its setpoint speed; the alarm signal reverts to high. Page Attention: With these fan specials, deviations as regards temperature range, voltage range and power consumption are possible compared with standard fans. Electrical connection Fan Supply Voltage UB Customer (+) Power UB t UB t2 +UBS n output Isink US Speed n>nG nG locked n=0 min-1 n>nG n>nG n nG 0 ≤ 60 20 ≤ 15 * 1500 ± 100 47 2 60 n > nG 0 ≤ 60 20 ≤ 15 * 1150 ± 100 47 n < nG 2 60 n > nG 0 ≤ 60 20 ≤ 15 * 850 ± 100 47 n < nG 2 60 n > nG 0 ≤ 60 15 ≤ 15 * 1330 ± 60 59 60 4312/17 T VARIOFAN ≤ 0,4 n < nG 2 4314/17 T VARIOFAN ≤ 0,4 n < nG 4318/17 V VARIOFAN ≤ 0,4 7214 N/17 ≤ 0,4 AC axial fans * After switching on UB Accessories AC centrifugal fans Attention: With these fan specials, deviations as regards temperature range, voltage range and power consumption are possible compared with standard fans. 115 Representatives 2 Condition: Alarm output voltage UA Low n < nG DC fans - specials ≤ 60 ≤ 0,4 Page ACmaxx / i-maxx 0 4312/17 MV VARIOFAN min –1 Fan description Alarm delaytime t2 n > nG VDC Speed limit nG Max. permissible Sink current S VDC Type Condition: Alarm operatingvoltage UBA max. mA mA Alarm signal data Condition: VDC Alarm outputvoltage UA High mA Condition: Isink = Condition: Isource = DC centrifugal fans DC axial fans Available on request: – With integrated signal latching for subsequent recognition of short-time faults. – Alarm circuit open collector or TTL. – Electrically isolated for maximum device safety; Defects in the power circuit do not affect the alarm circuit. Alarm signal /19 Alarm delaytime t2 n < nG 0 ≤ 60 20 ≤ 15 * 1500 ± 100 38 60 n < nG 0 ≤ 60 20 ≤ 15 * 1500 ± 100 46 2 60 n < nG 0 4,5–60 10 10 ± 4 * 1800 ± 20 59 n > nG 2 ≤ 28 n < nG 0 16–28 10 10 ± 4 * 1900 ± 100 84 n > nG 2 ≤ 28 n < nG 0 16–28 10 10 ± 4 * 1900 ± 100 94 ≤ 0,4 n > nG 2 60 4312 /19 ≤ 0,4 n > nG 2 7214 N /19 ≤ 0,4 n > nG RLF 100-11/14 /19 ≤ 0,4 RER 101-36/18N /19 HH ≤ 0,4 Speed limit nG 8314 /19 H Condition: Alarm output voltage UA Low VDC Fan description Max. permissible Sink current S VDC Type Condition: Alarm operatingvoltage UBA max. mA mA Alarm signal data Condition: VDC Alarm output voltage UA High mA Condition: Isink = Condition: Isource = – Alarm signal for speed monitoring. – Signal output via open collector. – The fan emits a low continuous signal during trouble-free operation within the permissible voltage range. – High signal when speed limit is not reached. – After elimination of fault, the fan returns to its setpoint speed; the alarm signal reverts to low. min –1 Page * After switching on UB Attention: With these fan specials, deviations as regards temperature range, voltage range and power consumption are possible compared with standard fans. Available on request: – With integrated signal latching for subsequent recognition of short-term faults. – Alarm circuit open collector or TTL. – Electrically isolated for max. device safety; defects in power circuit have no effect on the alarm circuit. Electrical connection Fan Supply Voltage UB Customer (+) Power UB t UB +UBS t2 nG n>nG output Isink Speed locked n=0 min-1 n>nG n>nG n nG 0 ≤ 28 10 nG 0 ≤ 28 10 nG Speed n>nG *) locked n=0 min-1 US t Accessories Fan Supply Voltage UB (-) Power UA UAHigh Alarm Signal UALow All voltages measured to ground. External load resistor Ra from UA to UBA required. t t 2 = Alarm signal suppression during start-up. * n < Speed limit nG by braking or locking. 117 Representatives Electrical connection AC centrifugal fans AC axial fans Attention: With these fan specials, deviations as regards temperature range, voltage range and power consumption are possible compared with standard fans. Alarm signal /39 NG ≤ 28 10 nG 2 28 618 N /39 N ≤ 0,5 n > nG 2 3412 N/39 H ≤ 0,5 n > nG 3414 N/39 HH ≤ 0,5 n > nG 4412 F/39 GL ≤ 0,5 4412 F/39 M ≤ 0,5 614 N /39 M Condition: n = nG 28 ≤ 0,5 612 F/39 H Condition: 28 2 Alarm output voltage UA Low 2 n > nG 412 /39 Fan description 0 n > nG VDC Speed limit nG S VDC Type Condition: Max. permissible Sink current Isink mA mA Alarm signal data Alarm delaytime t2 Alarm operatingvoltage UBA max. VDC Alarm output voltage UA High mA Condition: Isink = Condition: Isource = – Alarm signal for speed monitoring. – Signal output via open collector. – The fan emits a low continuous signal during trouble-free operation within the permissible voltage range. – High signal when speed limit is not reached. – After elimination of fault, the fan returns to its setpoint speed; the alarm signal reverts to low. min –1 Page * * * * 0 25 0 28 0 31 0 31 * * 0 40 n=max approx. 1 V -> n=min < 1 V -> n=0 start up at > 14 % start up at > 1.4 V Customer circuit Connection + GND Tach 0-10 V PWM Line 1 red blue white violet Line Connection Colour Assignment / function Line Connection Colour Assignment / function 1 + red Maximum ripple ± 3.5 % 1 Tach GND blue GND white 3 pulses / revolution 0-10 V / PWM violet 122 Tach output: Control input (Impedance 100 kΩ) Fan Information against environmental influences HP Û S P IP54 ACmaxx / i-maxx Stainless steel bearings Special bearings made of stainless steel provide additional protection. AC axial fans IP 54 protection The motor and circuit board are coated to protect them against splash water and humidity. High protection classes up to IP 67 are available on request. Salt spray fog protection Salt spray fog is extremely demanding on the resistance of the product. ebm-papst makes use of technologies that protect fans and blowers from salt spray fog reliably and durably. Accessories AC centrifugal fans The solutions that are available and in use can differ depending on size. We would be glad to develop solutions tailored to the demands of your application. 123 Representatives Moisture protection A coating on the motor and printed circuit board protects against humidity and condensation. DC fans - specials DC centrifugal fans – Meeting special requirements for a broad range of applications. – Resistant to environmental influences, such as dust, splash water, humidity, spray water and salt spray fog. – Highly competent solutions for adapting fans to environmental conditions. DC axial fans Protected fans 124 Accessories AC centrifugal fans AC axial fans ACmaxx / i-maxx DC fans - specials ACmaxx / i-maxx overview 130 ACmaxx / i-maxx axial fans 131 125 DC axial fans 126 DC centrifugal fans ACmaxx / i-maxx technical information Representatives Information ACmaxx / i-maxx ACmaxx / i-maxx Technical information Progress made by ebm-papst The best example: The ACmaxx fans from ebm-papst, which, thanks to an ingenious yet simple improvement over conventional AC fans, provide substantial benefits. The aim in developing the new ACmaxx series was to raise the technology standard of the conventional AC fan significantly and, in the process, facilitate the transition to the new technology by retaining the overall mounting dimensions. In short, to ensure the fans can be replaced 1:1 without any peripheral changes or changes to the voltage situation. ebm-papst offers two generations of ACmaxx products that meet different needs. AC ACmaxx i-maxx What ACmaxx and i-maxx have in common: Energy efficiency Long service life The drive concept is based on state-of-the-art GreenTech EC technology with outstanding motor efficiency. Compared to AC fans of the same size, ACmaxx energy consumption is up to 77% lower–for higher cooling capacity! The energy balance alone means that the products pay for themselves after only a few months. The savings over the entire service life, especially in systems with multiple fans, is considerable. The efficiency of ACmaxx and i-maxx motors is up to 75% higher than that of conventional AC fan variants. This not only saves energy, it also means less intrinsic heating in the motor. The reduced heating has a direct, positive effect on the bearing system, which is why the fans have a service life that is up to 85% longer! This also lengthens the service and maintenance intervals significantly. The expense of replacement fans, and even more expensive downtimes, are kept to a manageable minimum. [ EUR ] h 60 AC 40 N 000 4 80000 70000 70000 20 AC 4300 60000 ACi 4400 50000 88% increase in life time 40000 37500 0 0 1 2 3 Years 30000 20000 The ACmaxx and i-maxx fans are prepared for direct connection to all AC voltages and frequencies. The speed, and thus important properties of the fan such as air flow and noise, are independent of the power frequency and do not change, even within the defined voltage range. Voltage fluctuations in the power system are automatically compensated for. 126 10000 Service Life Independent of mains frequency and mains voltage AC Standard ACmaxx Information i-maxx is more efficient! ACmaxx saves energy, and the i-maxx generation saves even more. While an AC fan at 50 Hz can barely reach an overall efficiency of 5-6%, the ACmaxx makes it to approx. 20-25%. With the new i-maxx ACi 4400, a remarkable level of up to 30% is reached. This is the result of the optimisation of the entire package made up of drive, electronics, AC/DC conversion and aerodynamics. Thus the new i-maxx series boasts energy savings of almost 75% compared to the corresponding AC fan, thus providing significantly higher savings than the 40% level of the old AC 4300 generation. ACmaxx / i-maxx Safety • Safety certifications: UL, CSA and VDE 0805 / EN60950. VDE 0700 / EN60335 on request. • Our fans have the CE mark of conformity. • EMC protection: > EN61000-4-4 Level 1 (1 kV or 2 kV)B > EN61000-4-2 Level 8 kV/15 kV or 4 kV/8 kV > EN61000-4-3 > EN61000-4-6 > EN61000-4-8 > EN55022 Class B Use Use [%] 80 60 AC axial fans Saving 40 Saving Use Ambient influences AC fans are extremely common and are used in a wide variety of applications. In control cabinet cooling, beer coolers, cooling cabinets, wood-burning stoves, medical devices – all have different requirements for resistance to ambient influences. ACmaxx and i-maxx fans offer the same features for protection against moisture, splash water and rough ambient conditions. DC fans - specials DC centrifugal fans DC axial fans ACmaxx / i-maxx 20 AC 4000 N AC 4300 ACi 4400 Speed independent of voltage and frequency For the i-maxx ACi 4400, the speed, and thus the air flow and operating noise, are independent of the supply voltage and power frequency. Versions are available for 115 VAC with a voltage range from 85 to 132 VAC and 230 VAC with a voltage range of 195 to 265 VAC. Voltage fluctuations and frequency differences in the power system are compensated for automatically. ACmaxx i-maxx 127 Accessories i-maxx is quieter! The i-maxx ACi 4400 is quieter! Quieter than AC fans and quieter than the existing ACmaxx generation. The reason for this is the optimised aerodynamics and the drive, which is optimised for minimum structure-borne noise. Thus the fan is only half as loud at comparable air performance, and is up to 6 dB(A) quieter at some operating points. Representatives i-maxx is more compact! As large as existing AC fans – and not a bit larger. This is the most outstanding feature of the new i-maxx ACi 4400. Even in the hub area, the fan does not differ from typical 119x119x38 mm AC fans. Out with the AC, in with the i-maxx ACi 4400 – it's that simple. AC centrifugal fans Particular design features of the i-maxx (ACi 4400): ACmaxx / i-maxx Technical information Particular design features of the ACmaxx: Higher flexibility The flexibility of ACmaxx is one-of-a-kind. With its intelligent features, ACmaxx can be individually adapted to the specific application: standby mode, overload mode at peak times or night reduction all the way to temperature-controlled quiet operation are all possible. From speed setting to alarm or speed signal outputs, ACmaxx offers optional interfaces with which you can quickly and easily implement operation monitoring. 128 Pa [in H2O] Or you can simply contact our application engineers to discuss your ideal ACmaxx or i-maxx fan. 100 0,4 75 0,3 125 0,5 150 50 0,2 Higher performance Unlike conventional AC technology, the state-of-the-art drive concept of this fan series is not linked to a fixed power frequency. This allows the motor speed to be increased over a wide range. Thus ACmaxx provides significantly higher air flow and significantly increased pressure. You can find further information about these fan options in the "Specialised fans" chapter, starting on page 107. 25 0,1 Prepared for all AC voltages These models have a very wide voltage range from 85 to 265 VAC – the global voltage range, so to speak. This enables the fan to be used around the world, opening up large savings potentials. In addition to reduced logistics effort and stock-keeping, worldwide availability is key. ACmaxx is compatible with every supply voltage–no switching needed. From 85 to 265 volts and mains frequencies of 50 and 60 hertz. Voltage fluctuations in the power system are automatically compensated for. 0 ACmaxx 120 mm Standard AC fans 120 mm 30 60 90 120 50 100 150 200 150 250 CFM m³/h Information DC centrifugal fans DC axial fans Optional special versions Information on pictograms DC fans - specials On the pages of the catalogue and on the following overview pages, the pictograms illustrated below provide information about technically possible special versions in the fan line presented. Please note that these special versions are not possible for all voltages and speeds, and not in all combinations. The special versions are designed for specific customers and projects and are not usually available off the shelf. PWM control input Go / No-go alarm The fan uses a separate wire to output a static signal Analogue control input when it is stationary, thus providing information about A The speed of the fan can be changed via a control voltage. This control voltage is applied to a specially provided details, please refer to page 117. wire. For technical details, please refer to page 121. Alarm with limit speed Multi-option control input If the speed drops below a certain level defined in the The fan has a control input that the user can trigger eit- fan's electronics, the fan will emit a static signal, thus her using a PWM signal, an analogue signal or a providing information about whether or not the rotor is resistor. For technical details, please refer to page 122. External temperature sensor An NTC is connected to the fan via a separate wire and HP the fan changes its speed depending on the temperature at the NTC. For technical details, please refer to page 120. Internal temperature sensor Protection against moisture Protection for the fan's electronics against moisture and condensation. For technical details, please refer to page 123. Û IP54 IP 54 Protection of motor and PCB board against splashed water and humidity. For technical details, please refer to In this case, the NTC is integrated into the fan and the page 123. fan changes its speed depending on the temperature at Protection against salt spray fog the NTC. For technical details, please refer to page 120. SP ACmaxx / i-maxx provided wire. For technical details, please refer to page 121. turning. For technical details, please refer to page 114. I modulated signal. This signal is applied to a specially For technical details, please refer to page 110. whether or not the rotor is turning. For technical T The speed of the fan can be changed via a pulse-width- Accessories NG PWM AC axial fans about its speed, and thus about the speed of the rotor. AC centrifugal fans The fan uses a separate wire to output information Protection of fan against the damaging effects of salt spray fog. For technical details, please refer to page 123. 129 Representatives Speed signal Fans for AC operation Page Air flow Series Dimension Overview of air performance m3/h 10 mm  80 x 32 AC 8300 H  92 x 38 AC 3200 J  119 x 25 AC 4400 FN  119 x 32 AC 4300 H 20 80 30 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 3000 108 131 144 109 132 205 110 133 204 134 ACi 4400 100..180 135 172 Ø x 51 AC 6100 N 350 136 172 Ø x 51 AC 6200 N 350 137 NEW 98,5 Ø x 130 AC 100 NR 80..135 138 NEW  119 x 38 aring Go / mm AC 8300 H 80 x 80 x 32 * • • • • • • • – • • • 131 AC 3200 J 92 x 92 x 38 * • • • • • • • – • • • 132 AC 4400 FN 119 x 119 x 25 * • • • • • • • – • – – 133 AC 4300 119 x 119 x 32 * • • • • • • • – • • • 134 NEW ACi 4400 119 x 119 x 38 – – – – – – – – • • • 135 VDE Sinte Series Dim Sens or ve be c slee ensi , UL, on CSA s / ba ll bea No-g o ala Alarm rm with limit spee Exte d rnal temp eratu Inter nal t re se emp nsor e ratu PWM re se cont n sor rol in Anal put ogue cont Mult rol in i-op put tion cont rol in Hum put idity prot ectio IP > n = IP 54 Salt spra y fog prot ectio Page n rings Overview of technically feasible designs ACmaxx / i-maxx Axial fans OPTIONAL P. AC 6100 N 172 Ø x 51 * • • • • • • • – • • • 136 AC 6200 N 172 Ø x 51 * • • • • • • • – • • • 137 – – – – – – – – • • – 138 NEW AC 100 100 Ø x 130 – not yet available • available Sleeve bearings Ball bearings * Partially granted, partially in registration stage. Please note that these special versions are not possible for all voltages and speeds, and not in all combinations. The special versions are designed for specific customers and projects. As a rule they are not available off the shelf and are tied to minimum volumes. Please consult your customer support representative about the feasibility of your special variant. 130 Information ACmaxx axial fans Series AC 8300 H 80 x 80 x 32 mm / Watts RPM °C 85 ... 265 48 6,2 / 7,5 5 000 -20...+75 115 / 230 50 / 60 DC axial fans DC centrifugal fans Bel(A) Hours Hours 55 000 / 25 000 Curve dB(A) at T max VAC Service life L10 at 40 °C Nominal speed Hz Temperature range Power input 47,1 Sintec sleeve bearings Ball bearings 80 AC 8300 H Sound power level V Sound pressure level Type Voltage range CFM Nominal data Frequency Nominal voltage m3/h Air flow Air flow Highlights: – Universally suitable for all AC voltages between 85 and 265 V. – Fan speed not dependent on line frequency. – Significantly reduced power consumption compared to conventional AC fans. – Open loop speed control, sensor and alarm signal possible on request. General attributes: – Material: fibreglass-reinforced plastic. PA impeller, PBTP housing. – Fully integrated electronic commutation. – Protected against locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation clockwise, seen on rotor. – Mass: 325 g. 1 DC fans - specials 80 m3/h max. 1 Accessories 0,3 0,2 60 20 0,1 40 5 22 32 + 0,3 0 8 10 16 20 30 24 40 32 50 40 60 64 + 0,5 CFM m³/h NG T I PWM A HP Û S P IP54 131 Representatives 80 0,4 120 100 AC centrifugal fans [in H2O] Pa AC axial fans ACmaxx / i-maxx Speed variants available on request. ACmaxx axial fans 144 m3/h max. Series AC 3200 J 92 x 92 x 38 mm Service life L10 at 40 °C at T max Hz VAC dB(A) Bel(A) / Watts RPM °C Hours Hours 85 ... 265 55 6,4 / 11 6 800 -20...+70 HP IP54 115 / 230 50 / 60 Pa [in H2O] Speed variants available on request. 1 0,1 40 0,2 80 0,3 0,4 120 0,5 160 0,6 0,7 61.7+ 0.2 54.2 + 0.15 200 6+ 0.3 6+ 0.3 38 + 0.5 0 15 20 132 30 40 45 60 80 60 100 75 120 NG 70.7 + 0.8 0.3 CFM m³/h T I PWM A Û S P 70 000 / 35 000 Curve Temperature range 84,8 Nominal speed 144 Power input AC 3200 JH Sintec sleeve bearings Ball bearings V Sound power level CFM Sound pressure level Nominal voltage m3/h Voltage range Air flow Type Nominal data Frequency Air flow Highlights – Universally suitable for all AC voltages between 85 and 265 V. – Fan speed independent of power frequency. – Significantly reduced power consumption compared to conventional AC fans. – Open loop speed control, sensor and alarm signal possible on request. – Rigid compression curve for high air flow at high back pressure. – Innovative impeller with winglets for low noise levels. General attributes: – Material: fibreglass-reinforced plastic. PA impeller, PBTP housing. – Fully integrated electronic commutation. Protected against locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation clockwise, seen on rotor. – Mass: 325 g. 1 Information ACmaxx axial fans Series AC 4400 FN 119 x 119 x 25 mm DC axial fans at T max DC centrifugal fans Service life L10 at 40 °C Hz VAC dB(A) Bel(A) / Watts RPM °C Hours Hours 85 ... 265 53 6,2 / 12 4 850 -20...+70 115 / 230 50 / 60 60 000 / 30 000 Curve Temperature range 120,7 Nominal speed 205 Power input AC 4400 FNN Sintec sleeve bearings Ball bearings V Sound power level CFM Sound pressure level Nominal voltage m3/h Voltage range Air flow Type Nominal data Frequency Air flow Highlights: – Universally suitable for all AC voltages between 85 and 265 V. – Fan speed independent of power frequency. – Significantly reduced power consumption compared to conventional AC fans. – Open loop speed control, sensor and alarm signal possible on request. – Rigid compression curve for high air flow at high back pressure. – Innovative impeller with winglets for low noise levels. General attributes: – Material: fibreglass-reinforced plastic. PA impeller, PBTP housing. – Fully integrated electronic commutation. Protected against locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 370 g.. 1 DC fans - specials 205 m3/h max. 150 Accessories 0,5 0,2 25 25.4 + 0.15 0 30 50 60 100 90 150 120 200 150 250 CFM m³/h 57.9 + 0.5 NG T I PWM A HP 133 Representatives 50 0,1 75 0,4 100 1 0,3 125 AC centrifugal fans [in H2O] Pa AC axial fans ACmaxx / i-maxx Speed variants available on request. ACmaxx axial fans 204 m3/h max. Series AC 4300 119 x 119 x 32 mm dB(A) Bel(A) / Watts 120,1 115 / 230 50 / 60 RPM °C Hours Hours 85 ... 265 51 6,4 / 11 3 400 -20...+70 HP IP54 0,2 O 60 O 54 52,7 0,3 1 80 max. 0,4 mm Rotorüberstand Rotor protrudes [in H2O] Pa Speed variants available on request. 0,1 40 20 22 0 134 15 30 45 60 75 90 CFM 25 50 75 100 125 150 m³/h NG 64 + 0,6 T I PWM A Û S P 45 000 / 22 500 Curve VAC at T max Hz Service life L10 at 40 °C Power input V Temperature range Sintec sleeve bearings Ball bearings CFM Nominal speed Sound power level 204 Sound pressure level AC 4300 H Voltage range m3/h Frequency Type Nominal voltage Nominal data Air flow Air flow Highlights: – Universally suitable for all AC voltages between 85 and 265 V. – Fan speed independent of power frequency. – Significantly reduced power consumption compared to conventional AC fans. – Open loop speed control, sensor and alarm signal possible on request. General attributes: – Material: fibreglass-reinforced plastic. PA impeller, PBTP housing. – Fully integrated electronic commutation. – Protected against locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation clockwise, seen on rotor. – Mass: 325 g. 1 Information 180 m3/h max. i-maxx axial fans Series ACi 4400 119 x 119 x 38 mm DC axial fans DC centrifugal fans Hours DC fans - specials Hours 100 58,8 230 195...265 25 4,1 1,4 1 850 -20...+75 80 000 / 30 000 160 000 1 NEW ACi 4420 H 160 94,1 230 195...265 39 5,1 3,3 3 000 -20...+75 70 000 / 30 000 140 000 2 NEW ACi 4420 HH 180 105,9 230 195...265 42 5,3 4,4 3 350 -20...+75 62 500 / 30 000 125 000 3 NEW ACi 4410 HH 180 105,9 115 85...132 42 5,3 4,4 3 350 -20...+75 62 500 / 30 000 125 000 3 AC centrifugal fans AC axial fans NEW ACi 4420 ML ACmaxx / i-maxx °C (40 °C) RPM Curve Life expectancy L10Δ Service life L10 (Tmax) ebm-papst Standard Service life L10 (40 °C) ebm-papst Standard Watts Temperature range / dB(A) Bel(A) Nominal speed VAC Power input VAC Sintec sleeve bearings Ball bearings CFM Sound power level Voltage range m3/h Sound pressure level Nominal voltage Type Air flow Nominal data Air flow Highlights: – Energy efficient AC fan with EC technology. – Conversion and drive electronics fully integrated. – Significant lower power consumption than existing AC fans. – Significantly lower noise than existing AC fans. – Significant higher service life than existing AC fans. – Fan speed not dependent on line frequency. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Electronic locked rotor protection. – Electrical connection via 2 flat plugs 2,8 x 0,5 mm, flying leads optional. – Air exhaust over struts, direction of rotation clockwise, seen on rotor. – Mass: 250 g. 38 +0,5 Pa [in H2O] 6 +0,3 6 +0,3 3 60 Accessories 0,20 2 0,10 40 1 0 20 20 40 50 60 100 80 100 150 CFM m³/h HP Û S P IP54 135 Representatives 0 ACmaxx axial fans 350 m3/h max. Series AC 6100 N 172 ø x 51 mm Service life L10 at 40 °C at T max Hz VAC dB(A) Bel(A) / Watts RPM °C Hours Hours 85 ... 265 52 6,1 / 14 2 850 -20...+70 HP IP54 115 / 230 50 / 60 Speed variants available on request. (32.5) 50.8 +0.2 Pa [in H2O] Förderrichtung 50 0,2 25 0,1 75 0,4 100 1 0,3 125 0,5 150 3 +0.2 27.5 0 40 80 100 136 120 200 160 200 CFM 300 NG 83.3+0.6 m³/h T I PWM A Û S P 80 000 / 37 500 Curve Temperature range 206,0 Nominal speed 350 Power input AC 6100 NM Sintec sleeve bearings Ball bearings V Sound power level CFM Sound pressure level Nominal voltage m3/h Voltage range Air flow Type Nominal data Frequency Air flow Highlights: – Universally suitable for all AC voltages between 85 and 265 V. – Fan speed independent of power frequency. – Significantly reduced power consumption compared to conventional AC fans. – Open loop speed control, sensor and alarm signal possible on request. General attributes: – Material: fibreglass-reinforced PA housing and impeller. – Fully integrated electronic commutation. – Protected against locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation clockwise, seen on rotor. – Mass: 760 g. 1 Information ACmaxx axial fans 350 m3/h max. Series AC 6200 N 172 ø x 51 mm dB(A) Bel(A) / Watts RPM °C Hours Hours 85 ... 265 50 5,7 / 14 2 850 -20...+70 115 / 230 50 / 60 80 000 / 40 000 1 DC centrifugal fans at T max VAC DC fans - specials Service life L10 at 40 °C Hz Curve Temperature range 206,0 Nominal speed 350 Power input AC 6200 NM Sintec sleeve bearings Ball bearings V Sound power level CFM Sound pressure level Nominal voltage m3/h Voltage range Air flow Type Nominal data Frequency Air flow – Universally suitable for all AC voltages between 85 and 265 V, 50-60 Hz. – Fan speed independent of power frequency. – Significantly reduced power consumption compared to conventional AC fans. – Open loop speed control, sensor and alarm signal possible on request. General attributes: – Material: aluminium housing, fibreglass-reinforced PA impeller. Housing with grounding lug for screw M4 x 8 (Torx). – Fully integrated electronic commutation. – Protected against locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 900 g. DC axial fans Highlights: AC centrifugal fans AC axial fans ACmaxx / i-maxx Speed variants available on request. 166 50 100 100 CFM 150 200 300 63,7 Accessories 0,1 0 15 30,5 +0,2 m³/h NG T I PWM A HP Û S P IP54 137 Representatives 0,2 25 7,5 7,5 10 0,4 50 0,8 0,8 74 75 1 0,3 Pa 100 [in H2O] 83,3 +0,6 ACmaxx in-line duct fan 135 m3/h max. Series AC 100 NR Ø 98,5 x 130 mm Air flow Nominal voltage Frequency Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 at 40 °C at T max m3/h CFM V Hz VAC dB(A) Bel(A) / Watts RPM °C Hours Hours 80 47,1 105 61,8 Nominal data Type AC 100 NR 115/230 50-60 85...265 Pa 70 60 [in H2O] Optional: Max. speed at 135 m3/h (Curve 3). 2 50 40 30 20 3 0,16 boost 0,12 nominal 1 0,08 NEW 10 0 20 20 138 40 40 60 60 80 HP 80 100 120 Û IP44 CFM m³/h 35 4,7 2,5 2 750 42 5,3 4,5 3 500 -10...+55 70 000 / 40 000 Curve Air flow Highlights: – Highest energy efficiency thanks to EC technology. – Protection class IP44 (IP45 possible depending on mounting position). – Speed-boost function via mains voltage switch. – Vibration-isolated motor. – Global voltage - one product applicable for all line voltages and frequencies between 85-265 VAC and 50/60 Hz. Fan speed independent from power frequency. General features: – Material: fibreglass-reinforced plastic, housing PP, impeller PA. – Electrical connection via 3-pole terminal block, max. 1.5 mm2. – Protection class 2. – Approvals: VDE 60335-3-80. UL, CE, CSA on request. – Mass: 400 g. 1 2 Information DC axial fans 0.03 - 0.045 W/m3/h free air (Specific fan power). 2 speed settings possible via boost function. Reduced transmission of vibrations from motor to housing. Speed settings and control outputs optional. DC centrifugal fans Highest energy efficiency: Boost speed setting: Vibration isolation: Intelligence: Connection N L L Example 3: Simple connection, nominal speed without switching. ACmaxx / i-maxx N DC fans - specials Example 2: Nominal speed via light switch, separate boost switch. N L L AC centrifugal fans N AC axial fans Example 4: Simple connection, boost speed without switching. Accessories Scope of delivery 139 Representatives Example 1: Continuous operation at nominal speed boost speed via light switch. 140 Accessories AC centrifugal fans AC axial fans ACmaxx / i-maxx DC fans - specials 143 AC axial fans 144 141 DC centrifugal fans AC axial fan overview Representatives DC axial fans Information AC axial fans AC fans Technical information Product line The renowned ebm-papst AC fans are used when DC voltage is not available. The AC range of fans is based on experience gained from decades of development activity, millions of units in series production and competence in innovation of a world-wide technological leader. A wide range of fans for AC operation is presented in this catalogue. In addition to complete device fans, you will also find fans without external housing, providing a particularly economical advantage when the air duct can be integrated in the respective device. Variety of sizes AC fans are available in a variety of sizes with either air exhaust or air intake over struts. Silent running models with sleeve bearings or for extreme ambient conditions; fans with ball bearings are available with plug connection or external leads. Shaded-pole or capacitor motors Fan drives by shaded-pole or capacitor motors, most of which incorporate the world-famous ebm-papst external rotor principle: The fan blades are directly attached to the external rotor of the external rotor motor, thus combining both high performance and profitability. Flat built AC fans ebm-papst also has particularly flat built AC fans with internal rotor motor. Their advantage: quick start to full speed. A plastic impeller and the both smaller and lighter internal rotor motor lead to a lower moment of inertia. 142 Bearings AC fans with sleeve bearings are powered by Class E insulated motors. Fans with ball bearings are equipped with Class B, E or F insulated motors. Protection class All ebm-papst fans conform to the requirements of IP 20. Fans conforming to IP 54 and special types of protection class are also available. AC voltage The line of AC fans for Euro voltage according to IEC 60038 (230 V + 6 %, -10 %) is basically also available for 115 V. Frequencies AC fans can be operated at frequencies of 50 Hz or 60 Hz. However, their technical data then changes accordingly. Capacitor Fans driven by capacitor external motors provide particularly high operating efficiency. Generally, the required operating capacitor is already integrated in the fan housing. Overloading Almost all AC fans are protected against overloading (e.g. due to locked rotor) the drive motors are either impedance protected (marked “Impedance protected”, and/or “Z.P.”) or are equipped with a thermal switch (marked “Thermally protected” or “Th.P.”). The model designation of these fans ends with “S”. Information Axial fans for AC operation 20 30 50 40 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 3000  80 x 38 8000 A 29...57 144  80 x 38 8000 N 30...61 145 Ø 76 x 37 8000 TA 23...45 146 Ø 76 x 37 8000 TV 24...47 147  92 x 25 3900 31...70 148  92 x 38 3000 49...89 149  119 x 25 9900 84...135 150  119 x 38 4000 N 80...180 151  119 x 38 4000 Z 100...180 152 153 108 x 37 4600 TZ 125...140 154  127 x 38 5900 150...206  135 x 38 5600 235...270 156 150 x 172 x 38 7000 330...390 157 Ø 150 x 55 7800 325...380 158 Ø 150 x 55 7400 390...445 159 Ø 172 x 51 6000 375...500 160 Ø 225 x 80 W**200 450...1030 161 W2E 250 1865 162  280 x 80 129 155 • available mm 8000 A 80 x 80 x 38 yes / – 8000 N 80 x 80 x 38 yes / – 8000 TA 76 Ø x 37 yes / – 8000 TV 76 Ø x 37 yes / – 3900 92 x 92 x 25 yes / – 3000 92 x 92 x 38 yes / – 9900 119 x 119 x 25 yes / – 4000 N 119 x 119 x 38 yes / 4000 Z 119 x 119 x 38 yes / • • 4600 TA 113 Ø x 37 yes / – 4600 TZ 108 Ø x 37 yes / – 5900 127 x 127 x 38 yes / 5600 135 x 135 x 38 yes 7000 150 x 172 x 38 7800 7400 6000 prot On the pages of the catalogue and on the following overview pages, the sible special versions in the fan line presented. Please note that these special versions are not possible for all voltages Axial fans Series Information on pictograms pictograms illustrated below provide information about technically pos- Page Salt spra y fog ectio prot 54 idity = IP IP > nsor Hum d se Spee VDE Dim , UL, ensio n CSA Sinte c ball sleeve b bear earing ings s/ n ectio n Overview of technically feasible designs OPTIONAL P. and speeds, and not in all combinations. • • • • • • • • 144 The special versions are designed for specific customers and projects 145 and are not usually available off the shelf. – – 148 • • 149 The fan uses a separate wire to output information about its – – 150 speed, and thus about the speed of the rotor. For technical • • • • • • • • 151 – – 155 – • • • • • • • • • • • • • • • 156 yes – – – – 157 150 Ø x 55 yes • – – – 158 150 Ø x 55 yes – – – – 159 172 ¯ x 51 yes – – – – 160 – not yet available Sleeve bearings – DC fans - specials Ø ACmaxx / i-maxx 138...147 AC axial fans 4600 TA 146 147 Speed signal details, please refer to page 110. 152 153 154 HP Protection against moisture Protection for the fan's electronics against moisture and AC centrifugal fans 113 x 37 condensation. For technical details, please refer to page 123. Û IP54 IP 54 Protection of motor and PCB board against splashed water and humidity. For technical details, please refer to page 123. Ball bearings SP Protection against salt spray fog Accessories Ø DC axial fans 10 Protection of fan against the damaging effects of salt spray fog. For technical details, please refer to page 123. 143 Representatives m3/h mm DC centrifugal fans Page Air flow Series Dimension Overview of air performance 57 m3/h AC axial fans Series 8000 A Temperature range Service life L10 at 40 °C 9,0 1 750 -10...+80 60 000 / 25 000 1 / 12,5 2 150 -10...+70 52 500 / 25 000 2 5,0 / 12,0 2 700 -10...+70 52 500 / 25 000 3 37 5,1 / 12,0 2 800 -40...+90 52 500 / 15 000 3 60 29 4,3 / 8,0 1 950 -10...+80 62 500 / 25 000 4 115 60 34 4,8 / 11,0 2 500 -10...+70 55 000 / 27 500 5 115 60 41 5,5 / 11,0 3 200 -10...+75 55 000 / 25 000 6 115 60 42 5,7 / 11,0 3 300 -40...+95 55 000 / 15 000 6 m3/h CFM V Hz dB(A) Bel(A) 8880 A 29 17,1 230 50 26 4,1 8850 A 36 21,2 230 50 31 4,6 8550 A 48 28,3 230 50 36 8556 A 48 28,3 230 50 8830 A 34 20,0 115 8800 A 45 26,5 8500 A 57 33,5 8506 A 57 33,5 Nominal data Type 0,15 Pa 40 [in H2O] Series 8000 A with reinforced flanges 3 6 0,10 30 20 0,05 10 2 5 1 0 4 5 10 10 15 20 20 30 25 40 50 Hz 144 HP 30 50 CFM m³/h 60 Hz Û S P IP54 Curve Nominal speed / Sound power level Hours Sound pressure level °C Frequency RPM Nominal voltage Watts Air flow / Air flow Power input AC fans with external rotor shaded-pole motor. Impedance protected against overloading. Metal fan housing and impeller. Air intake over struts. Direction of rotation clockwise, seen on rotor. Electrical connection via 2 flat plugs 2.8 x 0.5 mm. Fan housing with grounding lug and screw M4 x 8 (TORX). Mass: 490 g. Optionally available with electrical connection via leads. Optionally available with air exhaust over struts and clockwise direction of rotation. Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. Sintec sleeve bearings Ball bearings – – – – – – – – – 80 x 80 x 38 mm at T max max. Hours Service life L10 at 40 °C 60 000 / 25 000 1 -10...+70 52 500 / 25 000 2 4,4 / 12,0 2 700 -10...+70 52 500 / 25 000 3 31 4,5 / 12,0 2 800 -40...+90 52 500 / 15 000 3 60 21 3,7 / 8,0 1 950 -10...+80 62 500 / 25 000 4 115 60 28 4,3 / 11,0 2 500 -10...+70 55 000 / 27 500 5 115 60 34 4,8 / 11,0 3 200 -10...+75 55 000 / 25 000 6 115 60 35 5,0 / 11,0 3 300 -40...+95 55 000 / 15 000 6 dB(A) Bel(A) 8880 N 30 17,7 230 50 18 3,3 8850 N 37 21,8 230 50 24 3,9 8550 N 50 29,4 230 50 30 8556 N 50 29,4 230 50 8830 N 36 21,2 115 8800 N 47 27,7 8500 N 61 35,9 8506 N 61 35,9 Fan type 8830 N Lead wires 8800 N 8880 N 8556 N 8500 N 310 mm long AWG 18, TR 64 310 mm long AWG 18, TR 64 310 mm long AWG 22 440 mm long AWG 18, TR 64 AC centrifugal fans 60 6 2 Accessories 0,20 3 0,15 5 0,10 30 4 20 1 0,05 10 0 5 10 10 15 20 20 30 25 40 50 Hz 30 50 CFM m³/h 60 Hz HP Û S P IP54 145 Representatives 40 8506 N 8550 N [in H2O] Pa 8850 N Hours ACmaxx / i-maxx Hz 50 Information Temperature range -10...+80 2 150 V Curve Nominal speed 1 750 12,5 CFM Type at T max Power input 9,0 / Sound power level / Sound pressure level Hours Frequency °C Nominal voltage RPM Air flow Watts Air flow / m3/h Nominal data DC centrifugal fans AC fans with external rotor shaded-pole motor. Impedance protected against overloading. Metal fan housing and impeller. Air exhaust over struts. Direction of rotation clockwise, seen on rotor. Electrical connection via 2 leads. Bared and tin-plated. Fan housing with grounding lug for screw M4 x 8 (TORX). Mass: 490 g. Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. Sintec sleeve bearings Ball bearings – – – – – – – 80 x 80 x 38 mm DC fans - specials Series 8000 N DC axial fans AC axial fans AC axial fans 61 m3/h max. 45 m3/h AC axial fans Series 8000 TA Service life L10 at 40 °C 9,0 1 650 -10...+80 60 000 / 25 000 – / 12,0 2 100 -10...+70 52 500 / 25 000 – 25 / 12,0 2 650 -10...+70 52 500 / 25 000 – 50 26 / 12,0 2 750 -40...+90 52 500 / 15 000 – 115 60 18 / 8,0 1 850 -10...+80 62 500 / 25 000 – 20,0 115 60 23 / 11,0 2 450 -10...+70 55 000 / 27 500 – 26,5 115 60 30 / 11,0 3 150 -10...+75 55 000 / 25 000 – 26,5 115 60 31 / 11,0 3 250 -40...+95 55 000 / 15 000 – 8800 TA 325 mm long AWG 18, TR 64 CFM V Hz dB(A) 8880 TA 23 13,5 230 50 15 8850 TA 30 17,7 230 50 19 8550 TA 38 22,4 230 50 8556 TA 38 22,4 230 8830 TA 26 15,3 8800 TA 34 8500 TA 45 8506 TA 45 Type The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise has been measured with an orifice 76.5 mm Ø at a distance of approx. 17 mm from the mounting bracket. Under exceptionally favourable mounting conditions, the air flow of fan series 8000 A is achievable. The noise in the optimal operating range can only be measured for these fans in a specific application. Fan type 8880 TA 8850 TA 8550 TA 8500 TA 325 mm long AWG 18, TR 64 8556 TA 8506 TA 325 mm long AWG 18 37 +1 10 ø75,8 325 +10 6 +1 HP Û S P IP54 R4 101 + 0,2 0,3 3 146 Hours Lead wires 8830 TA 90° Curve Temperature range / m3/h Nominal data at T max Nominal speed Hours Sound pressure level °C Frequency RPM Nominal voltage Watts Air flow / Air flow Power input AC fans with external rotor shaded-pole motor. Impedance protected against overloading. Impeller and mounting bracket of metal. Air intake over mounting bracket. Direction of rotation clockwise, seen on rotor. Electrical connection via 2 leads. Bared and tin-plated. Mass: 370 g. Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. Sintec sleeve bearings Ball bearings – – – – – – 76 Ø x 37 mm 3,7 + 0,15 max. Information Nominal speed Temperature range Service life L10 at 40 °C 9,0 1 650 -10...+80 60 000 / 25 000 – / 12,0 2 100 -10...+70 52 500 / 25 000 – 27 / 12,0 2 650 -10...+70 52 500 / 25 000 – 50 28 / 12,0 2 750 -40...+90 52 500 / 15 000 – 115 60 18 / 8,0 1 850 -10...+80 62 500 / 25 000 – 21,2 115 60 24 / 11,0 2 450 -10...+70 55 000 / 27 500 – 27,7 115 60 32 / 11,0 3 150 -10...+75 55 000 / 25 000 – 27,7 115 60 33 / 11,0 3 250 -40...+95 55 000 / 15 000 – 20 8550 TV 40 23,5 230 50 8556 TV 40 23,5 230 8830 TV 27 15,9 8800 TV 36 8500 TV 47 8506 TV 47 The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise has been measured with an orifice 76.5 mm Ø at a distance of approx. 17 mm from the mounting bracket. Under exceptionally favourable mounting conditions, the air flow of fan series 8000 N is achievable. The noise in the optimal operating range can only be measured for these fans in a specific application. Fan type ACmaxx / i-maxx 15 50 Lead wires 8880 TV 8850 TV 325 mm long AWG 18, TR 64 8550 TV 8500 TV 325 mm long AWG 18, TR 64 8556 TV 8506 TV 325 mm long AWG 18 3 8830 TV 8800 TV 37 +1 AC axial fans 50 230 AC centrifugal fans 230 18,2 10 R4 Accessories 14,1 31 Curve 24 8850 TV Hours 101 + 0,2 8880 TV 3,7 + 0,15 dB(A) 0,3 Hz ø75,8 V 325 +10 CFM Type at T max Power input / Sound pressure level Hours Frequency °C Nominal voltage RPM Air flow Watts Air flow / m3/h Nominal data DC centrifugal fans AC fans with external rotor shaded-pole motor. Impedance protected against overloading. Impeller and mounting bracket of metal. Air exhaust over mounting bracket. Direction of rotation clockwise, seen on rotor. Electrical connection via 2 leads. Bared and tin-plated. Mass: 370 g. Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. Sintec sleeve bearings Ball bearings – – – – – – 76 Ø x 37 mm DC fans - specials Series 8000 TV DC axial fans AC axial fans 90° HP Û S P IP54 147 Representatives 47 m3/h 6 +1 max. 70 m3/h max. AC axial fans Series 3900 Frequency Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 at 40 °C CFM V Hz dB(A) Bel(A) / Watts RPM °C Hours 3950 L 31 18,2 230 50 24 3,8 / 6,0 1 550 -10...+80 70 000 / 27 500 1 3956 L 31 18,2 230 50 24 3,8 / 6,0 1 550 -40...+80 70 000 / 27 500 1 3950 M 45 26,5 230 50 29 4,2 / 6,0 2 150 -10...+80 70 000 / 27 500 2 3956 M 45 26,5 230 50 29 4,2 / 6,0 2 150 -40...+80 70 000 / 27 500 2 3950 59 34,7 230 50 35 4,7 / 11,0 2 650 -20...+80 55 000 / 20 000 3 3956 59 34,7 230 50 35 4,7 / 11,0 2 650 -40...+80 55 000 / 20 000 3 3900 L 39 23,0 115 60 27 4,0 / 5,0 1 850 -10...+80 70 000 / 27 500 4 3906 L 39 23,0 115 60 27 4,0 / 5,0 1 850 -40...+80 70 000 / 27 500 4 3900 M 53 31,2 115 60 34 4,6 / 5,0 2 600 -10...+80 70 000 / 27 500 5 3906 M 53 31,2 115 60 34 4,6 / 5,0 2 600 -40...+80 70 000 / 27 500 5 3900 70 41,2 115 60 40 5,1 / 9,0 3 150 -20...+80 60 000 / 22 500 6 3906 70 41,2 115 60 40 5,1 / 9,0 3 150 -40...+80 60 000 / 22 500 6 Pa [in H2O] Type 60 16 40 0,15 50 0,20 3 15 2 0,10 30 14 20 1 0,05 10 0 10 10 20 20 30 30 40 50 50 Hz 148 HP CFM 60 m³/h 60 Hz Curve Nominal voltage m3/h Nominal data at T max Air flow AC fans with internal rotor shaded-pole motor. Impedance protected against overloading. Metal fan housing, impeller of mineral-reinforced plastic PA. Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. Electrical connection via 2 flat plugs 2.8 x 0.5 mm. Fan housing with grounding lug for screw M4. Mass: 280 g. Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. Air flow – – – – – – – 92 x 92 x 25 mm Hours Information Frequency Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 at 40 °C m3/h CFM V Hz dB(A) Bel(A) / Watts RPM °C Hours 3850 49 28,8 230 50 24 3,7 / 9,0 1 750 -10...+75 60 000 / 27 500 1 3856 54 31,8 230 50 26 3,9 / 9,0 1 950 -40...+90 60 000 / 20 000 2 3550 67 39,4 230 50 32 4,4 / 8,5 2 300 -10...+80 60 000 / 25 000 3 3556 67 39,4 230 50 33 4,5 / 8,5 2 400 -40...+90 60 000 / 20 000 3 3650 75 44,1 230 50 36 4,8 / 12,0 2 650 -10...+55 52 500 / 37 500 4 3656 75 44,1 230 50 37 4,9 / 12,0 2 700 -40...+75 52 500 / 22 500 4 3800 54 31,8 115 60 26 3,9 / 8,0 1 900 -10...+80 62 500 / 25 000 5 3806 60 35,3 115 60 29 4,2 / 8,0 2 150 -40...+95 62 500 / 17 500 6 3500 73 43,0 115 60 35 4,6 / 8,0 2 500 -10...+80 62 500 / 25 000 7 3506 73 43,0 115 60 36 4,7 / 8,0 2 600 -40...+95 62 500 / 17 500 7 3600 89 52,4 115 60 41 5,1 / 11,0 3 100 -10...+65 55 000 / 30 000 8 3606 89 52,4 115 60 42 5,2 / 11,0 3 200 -40...+75 55 000 / 25 000 8 Lead wires With sleeve bearings 310 mm long AWG 18, TR 64 With ball bearings 310 mm long AWG 18 AC centrifugal fans Fan type ACmaxx / i-maxx Hours [in H2O] Pa 60 8 0,25 70 Curve Nominal voltage Type Nominal data at T max Air flow DC centrifugal fans AC fans with external rotor shaded-pole motor. Impedance protected against overloading. Metal fan housing and impeller. Air exhaust over struts. Rotational direction CW looking at rotor. Electrical connection via 2 leads. Bared and tin-plated. Fan housing with grounding lug and screw M4 x 8 (TORX). Mass: 420 g. Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. Air flow – – – – – – – 92 x 92 x 38 mm DC fans - specials Series 3000 DC axial fans AC axial fans AC axial fans 89 m3/h max. 7 2 6 Accessories 0,15 3 0,10 30 20 5 0,05 10 1 0 10 10 20 30 20 30 40 50 40 60 50 Hz 70 CFM m³/h 60 Hz HP Û S P IP54 149 Representatives 40 0,2 4 50 135 m3/h max. AC axial fans Series 9900 119 x 119 x 25 mm Nominal voltage Frequency Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 at 40 °C CFM V Hz dB(A) Bel(A) / Watts RPM °C Hours 9956 L 84 49,4 230 50 29 4,4 / 9,5 1850 -40...+80 57 500 / 22 500 1 9956 M 104 61,2 230 50 35 4,7 / 10,0 2250 -40...+80 57 500 / 22 500 2 9950 117 68,9 230 50 37 5,0 / 14,0 2450 -20...+70 47 500 / 22 500 3 9956 117 68,9 230 50 37 5,0 / 14,0 2450 -40...+70 47 500 / 22 500 3 9906 L 100 58,9 115 60 34 4,6 / 8,0 2100 -40...+80 62 500 / 25 000 4 9906 M 111 65,3 115 60 37 5,0 / 8,0 2450 -40...+80 62 500 / 25 000 5 9900 135 79,5 115 60 42 5,4 / 12,0 2850 -20...+70 52 500 / 25 000 6 9906 135 79,5 115 60 42 5,4 / 12,0 2850 -40...+70 52 500 / 25 000 6 Pa 3 0,15 40 [in H2O] Type 30 6 0,10 2 4 1 0,05 20 10 5 0 15 20 30 40 45 60 80 60 CFM 100 m³/h 50 Hz 150 HP 60 Hz Curve Air flow m3/h Nominal data at T max Air flow – AC fans with external rotor shaded-pole motor. Protected against overloading by thermal cut-out. – Metal fan housing and impeller. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Electrical connection via 2 flat plugs 2.8 x 0.5 mm. – Fan housing with grounding lug and screw M4 x 8 (TORX). – Mass: 320 g. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. Hours 230 50 25 4,0 / 230 50 32 4,4 / 230 50 41 5,2 85,3 230 50 44 94,2 230 50 46 160 94,2 230 50 4840 N 85 50,0 115 4800 N* 97 57,1 115 4530 N* 151 88,9 115 4500 N* 169 99,5 115 4600 N 180 105,9 4606 N 180 105,9 47,1 100 58,9 4580 N* 123 72,4 4550 N* 145 4650 N 160 4656 N °C Hours 11,0 1 550 -10...+70 55 000 / 27 500 1 10,0 1 800 -10...+70 57 500 / 27 500 2 / 18,0 2 350 -10...+55 40 000 / 27 500 3 5,4 / 16,5 2 550 -10...+55 42 500 / 30 000 4 5,4 / 19,0 2 650 -10...+55 37 500 / 27 500 5 47 5,5 / 19,0 2 650 -40...+85 37 500 / 15 000 5 60 26 4,1 / 10,0 1 650 -10...+75 57 500 / 25 000 6 60 32 4,3 / 9,0 1 750 -10...+75 60 000 / 27 500 7 60 45 5,4 / 16,0 2 700 -10...+65 42 500 / 25 000 8 60 48 5,7 / 15,0 3 000 -10...+65 47 500 / 25 000 9 115 60 50 5,7 / 18,0 3 100 -10...+60 40 000 / 25 000 10 115 60 51 5,8 / 18,0 3 100 -40...+90 40 000 / 15 000 10 * Fan with 3 blades. AC centrifugal fans Pa [in H2O] 230 V and 115 V versions are rated for both 50 Hz and 60 Hz operation. For 60 Hz data, please refer to the corresponding 115 V 60 Hz model, for 50 Hz data please refer to the corresponding 230 V 50 Hz model. Hours 10 0,3 80 9 0,2 [in H2O] 8 40 0,1 5 7 20 0,3 Pa 60 80 DC axial fans Information RPM Curve 80 4850 N* Watts at T max 4890 N Service life L10 at 40 °C Sintec sleeve bearings Ball bearings / Temperature range Sound power level Bel(A) CFM Type Nominal speed Sound pressure level dB(A) m3/h Nominal data Power input Frequency Hz Air flow V Air flow Nominal voltage – AC fans with external rotor shaded-pole motor. Impedance protected against overloading. – Metal fan housing and impeller – Air intake over struts. Direction of rotation clockwise, seen on rotor. Types 4890 N and 4840 N air exhaust over struts. – Electrical connection via 2 flat plugs 3.0 x 0.5 mm. – Impeller with 3 or 5 blades, see note for fan type. – Optionally available: Models with reinforced flanges and single leads. – Fan housing with grounding lug for screw M 4 and UNC. – Mass: 550 g. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. DC centrifugal fans 119 x 119 x 38 mm DC fans - specials Series 4000 N ACmaxx / i-maxx AC axial fans AC axial fans 180 m3/h max. 60 4 0 20 0,2 25 40 50 75 60 100 80 125 Accessories 6 CFM m³/h 60 Hz 40 3 0,1 2 20 1 20 25 40 50 75 60 100 80 125 CFM m³/h 50 Hz HP Û S P IP54 151 Representatives 0 180 m3/h AC axial fans Series 4000 Z Sound power level Sintec sleeve bearings Ball bearings V Hz dB(A) Bel(A) / 4850 Z 100 58,9 230 50 26 4,0 / 4856 Z 100 58,9 230 50 26 4,0 / 4580 Z 115 67,7 230 50 30 4,3 4586 Z 115 67,7 230 50 30 4650 Z 160 94,2 230 50 40 4656 Z 160 94,2 230 50 4800 Z 105 61,6 115 4806 Z 105 61,6 115 4530 Z 120 70,6 4536 Z 120 70,6 4600 Z 180 4606 Z 180 40 13,0 1 700 -10...+65 50 000 / 27 500 1 13,0 1 700 -40...+75 50 000 / 20 000 1 / 13,0 1 900 -10...+65 50 000 / 27 500 2 4,3 / 13,0 1 900 -40...+75 50 000 / 20 000 2 5,3 / 19,0 2 650 -10...+50 37 500 / 30 000 3 40 5,3 / 19,0 2 650 -40...+75 37 500 / 17 500 3 60 28 4,1 / 12,0 1 800 -10...+70 52 500 / 25 000 4 60 28 4,1 / 12,0 1 800 -40...+75 52 500 / 17 500 4 115 60 32 4,4 / 12,0 2 000 -10...+70 52 500 / 25 000 5 115 60 32 4,4 / 12,0 2 000 -40...+75 52 500 / 17 500 5 105,9 115 60 45 5,6 / 18,0 3 100 -10...+60 40 000 / 25 000 6 105,9 115 60 45 5,6 / 18,0 3 100 -40...+85 40 000 / 15 000 6 2 0,10 5 20 1 0,05 4 0 20 25 40 50 75 60 100 80 125 100 150 50 Hz 152 HP CFM m³/h 60 Hz Û S P IP54 Curve Hours 6 3 30 10 °C [in H2O] 0,25 Pa 50 RPM 0,20 60 Watts 0,15 70 Service life L10 at 40 °C Sound pressure level CFM Temperature range Frequency m3/h Nominal speed Nominal voltage Type Nominal data Power input Air flow AC fans with external rotor shaded-pole motor. Impedance protected against overloading. Metal fan housing and impeller. Air exhaust over struts. Direction of rotation clockwise, seen on rotor. Electrical connection via 2 flat plugs 2.8 x 0.5 mm. Optionally available: Models with reinforced flanges and single leads. Fan housing with grounding lug and screw M4 x 8 (TORX). Mass: 540 g. Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. Air flow – – – – – – – – 119 x 119 x 38 mm at T max max. Hours 4650 TA 138 81,2 230 50 41 / 4656 TA 138 81,2 230 50 42 / 4600 TA 147 86,5 115 60 43 4606 TA 147 86,5 115 60 44 Information DC centrifugal fans / RPM °C Hours 19,0 2 550 -10...+45 37 500 / 32 500 – 19,0 2 550 -40...+75 37 500 / 17 500 – / 18,0 2 900 -10...+50 40 000 / 32 500 – / 18,0 2 900 -40...+80 40 000 / 17 500 – The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise has been measured with an orifice 109 mm Ø at a distance of approx. 17 mm from the mounting bracket. Under exceptionally favourable mounting conditions, the air flow of fan series 4600 N is achievable. The noise in the optimal operating range can only be measured for these fans in a specific application. Fan type Curve at T max Watts Hours Lead wires 4600 TA AWG 22, TR 32 4656 TA 4606 TA AWG 18 R4 16 37 +1 AC centrifugal fans AC axial fans 4650 TA DC fans - specials dB(A) ACmaxx / i-maxx Hz 3 0,5 +0,3 375 +10 6 +1 148,2 + 0,2 Accessories Sintec sleeve bearings Ball bearings V Service life L10 at 40 °C Sound pressure level CFM Temperature range Frequency m3/h Nominal speed Nominal voltage Type Nominal data Power input Air flow AC fans with external rotor shaded-pole motor. Impedance protected against overloading. Impeller and mounting bracket of metal. Air intake over mounting bracket. Direction of rotation clockwise, seen on rotor. Electrical connection via 2 leads. Bared and tin-plated. Mass: 430 g. Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. Air flow – – – – – – 113 Ø x 37 mm 90° HP Û S P IP54 153 Representatives Series 4600 TA DC axial fans AC axial fans ø112,5 + 0,3 147 m3/h 4,3 + 0,15 max. AC axial fans Series 4600 TZ Sintec sleeve bearings Ball bearings V Hz dB(A) / 4650 TZ 125 73,6 230 50 42 / 4656 TZ 125 73,6 230 50 42 / 4600 TZ 140 82,4 115 60 45 4606 TZ 140 82,4 115 60 45 RPM °C Hours 19,0 2 600 -10...+50 37 500 / 37 500 – 19,0 2 600 -40...+65 37 500 / 20 000 – / 18,0 2 950 -10...+50 40 000 / 32 500 – / 18,0 2 950 -40...+75 40 000 / 17 500 – The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise has been measured with an orifice 109 mm Ø at a distance of approx. 17 mm from the mounting bracket. Under exceptionally favourable mounting conditions, the air flow of fan series 4000 Z is achievable. The noise in the optimal operating range can only be measured for these fans in a specific application. Fan type 4600 TZ AWG 22, TR 32 4656 TZ 4606 TZ AWG 18 37 + 1 3 0,5 + 0,3 6 +1 148,2 + 0,2 ø108 + 0,3 R4 16 Hours Lead wires 4650 TZ 90° 154 HP Û S P IP54 Curve Watts at T max Service life L10 at 40 °C Sound pressure level CFM Temperature range Frequency m3/h Nominal speed Nominal voltage Type Nominal data Power input Air flow AC fans with external rotor shaded-pole motor. Impedance protected against overloading. Impeller and mounting bracket of metal. Air exhaust over mounting bracket. Direction of rotation clockwise, seen on rotor. Electrical connection via 2 leads. Bared and tin-plated. Mass: 430 g. Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. Air flow – – – – – – 108 Ø x 37 mm 375 +10 140 m3/h 4,3 + 0,15 max. Bel(A) / 150 88,3 230 50 37 4,9 / 180 105,9 230 50 43 5,4 / 5958 180 105,9 230 50 44 5,5 5938 162 95,3 115 60 40 5900 206 121,2 115 60 46 5908 206 121,2 115 60 47 5950 Information RPM °C Hours 13,0 2 250 -30...+55 35 000 / 20 000 1 18,0 2 700 -20...+50 40 000 / 32 500 3 / 18,0 2 750 -30...+60 40 000 / 25 000 3 4,9 / 12,0 2 500 -30...+55 35 000 / 20 000 2 5,7 / 17,0 3 050 -20...+55 42 500 / 30 000 4 5,8 / 17,0 3 100 -30...+75 42 500 / 20 000 4 Curve Watts Hours AC centrifugal fans 4 40 0,15 50 0,20 1 Accessories Pa 60 3 0,25 70 [in H2O] AC axial fans 5988 DC centrifugal fans Sintec sleeve bearings Ball bearings dB(A) ACmaxx / i-maxx Sound power level Hz Service life L10 at 40 °C Sound pressure level V Temperature range Frequency CFM Type Nominal speed Nominal voltage m3/h Nominal data Power input Air flow AC fans with internal rotor shaded-pole motor. Impedance protected against overloading. Metal fan housing and impeller of fibreglass-reinforced plastic PA. Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. Electrical connection via 2 flat plugs 2.8 x 0.8 mm. Fan housing with grounding lug and screw M4 x 6. Mass: 570 g. Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. Air flow – – – – – – – 127 x 127 x 38 mm DC fans - specials Series 5900 DC axial fans AC axial fans at T max 206 m3/h max. 2 0,10 30 0 20 25 40 50 75 60 100 80 125 100 150 50 Hz CFM m³/h 60 Hz HP 155 Representatives 10 0,05 20 270 m3/h max. AC axial fans Series 5600 135 x 135 x 38 mm Pa [in H2O] 100 138,3 230 50 46 5,9 / 158,9 115 60 50 6,2 / 2 1 0,2 60 20 0,1 40 0 40 50 80 100 150 120 200 50 Hz 156 HP CFM 250 m³/h 60 Hz Û S P IP54 Watts RPM °C Hours 30,0 2 700 -35...+70 45 000 / 20 000 1 26,0 3 100 -35...+80 47 500 / 20 000 2 Curve / at T max Bel(A) Service life L10 at 40 °C dB(A) Temperature range Hz Nominal speed V 0,3 80 CFM Power input 270 Sintec sleeve bearings Ball bearings 5606 S Sound power level 235 Sound pressure level 5656 S Frequency m3/h Nominal voltage Type Nominal data Air flow Air flow – AC fans with external rotor shaded-pole motor. Protected against overloading by thermal cut-out. – Metal fan housing and impeller. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Electrical connection via 2 flat plugs 2.8 x 0.5 mm. – Fan housing with grounding lug and screw M4 x 8 (TORX). – Mass: 800 g. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. Hours Information Series 7000 150 x 172 x 38 mm 230 50 51 6,4 / 223,6 115 60 56 6,8 / DC centrifugal fans 188,3 Watts RPM °C Hours 27,0 2 800 -25...+55 60 000 / 32 000 1 28,0 3 350 -25...+65 55 000 / 18 000 2 Hours ACmaxx / i-maxx / Curve Bel(A) at T max dB(A) Service life L10 at 40 °C Hz Temperature range V Nominal speed CFM Power input 380 Sintec sleeve bearings Ball bearings 7006 ES Sound power level 320 Sound pressure level 7056 ES Frequency m3/h Nominal voltage Type Nominal data Air flow Air flow – AC fans with external rotor capacitor motor. Protected against overloading by integrated thermal cut-out. – Metal fan housing and impeller. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Electrical connection via 2 flat plugs 2.8 x 0.5 mm. – Fan housing with grounding lug and screw M4 x 6. – Mass: 900 g. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. DC axial fans AC axial fans DC fans - specials 380 m3/h max. 1 AC centrifugal fans Pa [in H2O] 2 0,6 AC axial fans Minimum ambient temperature -15 °C. Accessories 0,2 80 0,3 0,4 120 0,5 160 0,1 40 40 50 80 100 150 120 200 160 250 200 300 50 Hz CFM m³/h 60 Hz 157 Representatives 0 380 m3/h max. AC axial fans Series 7800 150 Ø x 55 mm Sintec sleeve bearings Ball bearings Bel(A) / 191,3 230 50 49 6,0 / 191,3 230 50 49 6,0 / 380 223,7 115 60 53 6,4 380 223,7 115 60 53 6,4 325 7805 ES 7806 ES RPM °C Hours 45,0 2 800 -25...+50 60 000 / 47 000 1 45,0 2 800 -25...+70 60 000 / 23 000 1 / 38,0 3 250 -25...+70 60 000 / 47 000 2 / 38,0 3 250 -25...+90 60 000 / 18 000 2 80 0,5 Pa 100 0,4 120 2 0,3 140 [in H2O] Minimum ambient temperature -15 °C, admissible for a short time at -30 °C; without condensation. 1 0,2 60 20 0,1 40 0 40 50 80 100 150 120 200 160 250 200 300 50 Hz 158 CFM m³/h 60 Hz Curve 325 7856 ES Watts at T max 7855 ES Service life L10 at 40 °C Sound power level dB(A) Temperature range Sound pressure level Hz m3/h Nominal speed Frequency V Type Nominal data Power input Nominal voltage CFM Air flow Air flow – AC fans with external rotor shaded-pole motor. Protected against overloading by integrated thermal cut-out. – Metal fan housing and impeller. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Electrical connection via 2 leads. Bared and tin-plated. – Fan housing with grounding lug and screw M4 x 6. – Mass: 1.1 kg. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. Hours Information Series 7400 150 Ø x 55 mm 230 50 60 6,8 / 250,1 115 60 62 6,9 / DC centrifugal fans 223,6 Watts RPM °C Hours 47,0 2 700 -25...+50 63 000 / 50 000 1 46,0 3 050 -25...+70 50 000 / 24 000 2 Hours ACmaxx / i-maxx / Curve Curve Bel(A) at T max dB(A) Service life L10 at 40 °C Hz Temperature range V Nominal speed CFM Power input 425 Sintec sleeve bearings Ball bearings 7400 ES Sound power level 380 Sound pressure level 7450 ES Frequency m3/h Nominal voltage Type Nominal data Air flow Air flow – AC fans with external rotor shaded-pole motor. Protected against overloading by integrated thermal cut-out. – Metal fan housing and impeller. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Electrical connection via 2 leads. Strand ends with brass lead tips. – Fan housing with grounding lug and screw M4 x 6. – Mass: 1.1 kg. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. DC axial fans AC axial fans DC fans - specials 425 m3/h max. AC centrifugal fans [in H2O] Pa AC axial fans Minimum ambient temperature -15 °C, admissible for a short time at -30 °C; without condensation. 120 2 Accessories 0,4 0,2 60 20 0,1 40 0 40 80 100 120 200 160 200 240 400 300 50 Hz CFM m³/h 60 Hz 159 Representatives 80 1 0,3 100 500 m3/h max. AC axial fans Series 6000 172 Ø x 51 mm Sintec sleeve bearings Ball bearings dB(A) Bel(A) / 220,7 230 50 55 5,9 / 247,2 230 50 54 6,3 / 440 259,0 115 60 60 6,4 500 284,3 115 60 58 6,7 6058 ES 375 6078 ES 420 6008 ES 6028 ES RPM °C Hours 24,0 2 800 -25...+70 62 000 / 31 000 1 26,0 2 800 -25...+60 62 000 / 39 000 2 / 26,0 3 300 -25...+70 57 000 / 28 000 3 / 29,0 3 300 -25...+75 57 000 / 22 000 4 0,6 Pa 0,2 80 0,3 0,4 120 0 ,5 160 [in H2O] Minimum ambient temperature -15 °C, admissible for a short time at -30 °C; without condensation. 0,1 40 1 0 40 80 100 120 200 160 200 400 300 50 Hz 160 2 240 3 4 CFM m³/h 60 Hz Curve Watts at T max Service life L10 at 40 °C Sound power level Hz m3/h Temperature range Sound pressure level V Type Nominal speed Frequency Nominal data Power input Nominal voltage CFM Air flow Air flow – AC fans with external rotor capacitor motor. Protected against overloading by integrated thermal cut-out. – Metal fan housing and impeller. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Electrical connection via 2 flat plugs 2.8 x 0.5 mm. – Fan housing with grounding lug and screw M4 x 6. – Mass: 1.0 kg. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. Hours Information W** 200 225 x 225 x 80 mm Sound power level Sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 at 40 °C Hz dB(A) Bel(A) / Watts RPM °C Hours 606,2 115 60 61 6,7 / 80,0 2800 -25...+65 60 000 / 58 000 2 880 517,9 230 50 58 6,6 / 64,0 2550 -25...+60 63 000 / 60 000 2 450 264,9 230 50 40 4,7 / 30,0 1370 -25...+70 85 000 / 80 000 1 1030 W2E200-HK38-01* W4S200-HK04-01** [in H2O] 0,20 AC axial fans 30 0,1 1 0 50 100 100 150 200 200 300 250 400 CFM AC centrifugal fans 10 0,05 20 m³/h 0,4 2 Accessories Pa 80 0,3 100 [in H2O] 50 Hz 0,2 60 20 0,1 40 0 100 200 200 300 400 400 600 500 CFM 800 m³/h 50 Hz 60 Hz 161 Representatives 40 0,15 50 Hours ACmaxx / i-maxx W2E200-HK86-01* Pa m3/h DC fans - specials Sound pressure level V Type Curve Frequency Nominal data at T max Nominal voltage CFM Air flow Air flow – External-rotor single-phase motor.* / External rotor shaded-pole motor.** – Motor protection: TOP wired internally. – Material: Wall ring die-cast aluminium, seven blades of sheet steel. Blades and rotor coated in black. – Direction of air flow “V”, air exhaust over struts. Direction of rotation: counter-clockwise, seen on rotor. – Electrical connection: Terminal strip (operating capacitor connected). – Continuous operation (S1). – Insulation class: “F” – Mass: 2 kg. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. DC axial fans AC axial fans DC centrifugal fans 1030 m3/h max. max. 1865 m3/h AC axial fans W2E 250 280 x 280 x 80 mm Sound pressure level Sound power level Sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 at 40 °C V Hz dB(A) Bel(A) / Watts RPM °C Hours 230 50 66 7,2 / 127,0 2 550 -25...+60 1865 1077,1 Pa W2E 250-HL06-01 [in H2O] m3/h 80 0,4 100 32 0,3 120 0,5 140 0,2 60 20 0,1 40 0 200 400 400 800 600 1200 800 CFM 1600 50 Hz 162 m³/h 60 Hz Curve Frequency CFM Type at T max Nominal voltage Nominal data Air flow Air flow – External-rotor single-phase motor. – Motor protection: TOP wired internally. – Material: Wall ring die-cast aluminium, seven blades of sheet steel. Blades and rotor coated in black. – Direction of air flow “V”, air exhaust over struts. Direction of rotation: counter-clockwise, seen on rotor. – Electrical connection: Terminal strips (operating capacitor connected). – Continuous operation (S1). – Insulation class: “F” – Mass: 2 kg. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. Hours 63 000 / 70 000 3 Accessories AC centrifugal fans AC axial fans ACmaxx / i-maxx DC fans - specials 165 AC centrifugal fans 166 163 DC centrifugal fans AC centrifugal fan overview Representatives DC axial fans Information AC centrifugal fans AC fans Technical information Product line The renowned ebm-papst AC fans are used when DC voltage is not available. The AC range of fans is based on experience gained from decades of development activity, millions of units in series production and competence in innovation of a world-wide technological leader. A wide range of fans for AC operation is presented in this catalogue. In addition to complete device fans, you will also find fans without external housing, providing a particularly economical advantage when the air duct can be integrated in the respective device. Variety of sizes AC fans are available in a variety of sizes with either air exhaust or air intake over struts. Silent running models with sleeve bearings or for extreme ambient conditions; fans with ball bearings are available with plug connection or external leads. Shaded-pole or capacitor motors Fan drives by shaded-pole or capacitor motors, most of which incorporate the world-famous ebm-papst external rotor principle: The fan blades are directly attached to the external rotor of the external rotor motor, thus combining both high performance and profitability. Flat built AC fans ebm-papst also has particularly flat built AC fans with internal rotor motor. Their advantage: quick start to full speed. A plastic impeller and the both smaller and lighter internal rotor motor lead to a lower moment of inertia. 164 Bearings AC fans with sleeve bearings are powered by Class E insulated motors. Fans with ball bearings are equipped with Class B, E or F insulated motors. Protection class All ebm-papst fans conform to the requirements of IP 20. Fans conforming to IP 54 and special types of protection class are also available. AC voltage The line of AC fans for Euro voltage according to IEC 60038 (230 V + 6 %, -10 %) is basically also available for 115 V. Frequencies AC fans can be operated at frequencies of 50 Hz or 60 Hz. However, their technical data then change accordingly. Capacitor Fans driven by capacitor external motors provide particularly high operating efficiency. Generally, the required operating capacitor is already integrated in the fan housing. Overloading Almost all AC fans are protected against overloading (e.g. due to locked rotor) the drive motors are either impedance protected (marked “Impedance protected”, and/or “Z.P.”) or are equipped with a thermal switch (marked “Thermally protected” or “Th.P.”). The model designation of these fans ends with “S”. Information Centrifugal fans for AC operation 10 20 30 50 40 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 3000 121 x 37 RL 90 40...42 166  135 x 38 RG 90 47...54 167  180 x 40 RG 125 86...94 168  220 x 56 RG 160 202...223 169 Ø 138 x 40 RER 125 104...115 170 Ø 176 x 54 RER 160 234...274 171 – RG 90 135 x 135 x 38 yes / – RG 125 180 x 180 x 40 yes – RG 160 220 x 220 x 56 yes – RER 125 138 Ø x 40 yes – RER 160 176 Ø x 54 yes – – not yet available prot OPTIONAL Sleeve bearings • • • • • • P. • • • • • • • • • • • • and speeds, and not in all combinations. 166 The special versions are designed for specific customers and projects 167 and are not usually available off the shelf. AC axial fans / 168 169 Speed signal 170 The fan uses a separate wire to output information about its 171 speed, and thus about the speed of the rotor. For technical Ball bearings details, please refer to page 110. HP Protection against moisture Protection for the fan's electronics against moisture and AC centrifugal fans yes condensation. For technical details, please refer to page 123. Û IP54 IP 54 Protection of motor and PCB board against splashed water and humidity. For technical details, please refer to page 123. SP Protection against salt spray fog Accessories 121 x 121 x 37 sible special versions in the fan line presented. Protection of fan against the damaging effects of salt spray fog. For technical details, please refer to page 123. 165 Representatives • availabe mm RL 90 On the pages of the catalogue and on the following overview pages, the Please note that these special versions are not possible for all voltages Centrifugal fans Series Information on pictograms pictograms illustrated below provide information about technically pos- Page Salt spra y fog ectio prot 54 idity = IP IP > nsor Hum d se Spee VDE Dim , UL, ensio n CSA Sinte c ball sleeve b bear earing ings s/ n ectio n Overview of technically feasible designs ACmaxx / i-maxx DC fans - specials  DC axial fans m3/h mm DC centrifugal fans Page Air flow Series Dimension Overview of air prformance 42 m3/h max. AC centrifugal fans Series RL 90 121 x 121 x 37 mm Nominal voltage Frequency Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 at 40 °C CFM V Hz Bel(A) / Watts RPM °C Hours RL 90-18/50 40 23,5 230 50 5,6 / 20,0 2 450 -10...+50 37 500 / 30 000 1 RL 90-18/56 40 23,5 230 50 5,6 / 20,0 2 450 -30...+70 37 500 / 20 000 1 RL 90-18/00 42 24,7 115 60 6,0 / 19,5 2 550 -10...+60 37 500 / 25 000 2 RL 90-18/06 42 24,7 115 60 6,0 / 19,5 2 550 -30...+85 37 500 / 15 000 2 Type Pa [in H2O] Fan type 2 100 0,4 120 0,3 1 80 0,2 60 20 0,1 40 0 4 5 8 10 12 15 20 16 25 20 30 50 Hz 166 HP CFM m³/h 60 Hz Û S P IP54 Curve Air flow m3/h Nominal data at T max Air flow – AC centrifugal fan with external rotor shaded-pole motor. Impedance protected against overloading. – Spiral housing and impeller of fibreglass-reinforced plastic. Housing base of galvanised steel plate. Housing base with flat plug 6.3 x 0.8 mm for protective earth. – Direction of air flow radial, through housing port. Direction of rotation clockwise, seen on rotor. – Electrical connection via 2 leads. Bared and tin-plated. – Mass: 680 g. Hours Lead wires RL 90-18/50 RL 90-18/00 AWG 18, TR 32 RL 90-18/56 RL 90-18/06 AWG 22 Information 135 x 135 x 38 mm Type Type dB(A) Bel(A) Bel / / Watts Watts RPM RPM Curve DC centrifugal fans °C °C at T max Service life L10 at 40 °C Temperature range Nominal speed Power input Sintec sleeve bearings Ball bearings Sound power level Frequency Hz Hz Nominal data Air flow 3/s V DCV m3m /h3/h10-3 m CFM Air flow Nominal voltage – AC centrifugal fan with external rotor shaded-pole motor. Impedance protected against overloading. – Spiral housing and impeller of fibreglass-reinforced plastic. Housing base of galvanised steel plate. – Direction of air flow radial, through housing port. Direction of rotation clockwise, seen on rotor. – Electrical connection via 2 leads AWG 22. Bared and tin-plated. – Mass: 560 g. Hours Hours Hours Hours 54 31,8 230 50 5,8 / 22,0 2 200 -30...+60 35 000 / 20 000 1 RG 90-18/56 54 31,8 230 50 5,8 / 22,0 2 200 -30...+60 35 000 / 20 000 1 RG 90-18/00 47 27,7 115 60 6,2 / 22,0 1 900 -30...+65 35 000 / 20 000 2 RG 90-18/06 47 27,7 115 60 6,2 / 22,0 1 900 -30...+65 35 000 / 20 000 2 100 AC centrifugal fans 2 0,4 120 0,3 Accessories 1 80 0,2 60 20 0,1 40 0 5 10 10 15 20 20 30 25 40 50 Hz 30 50 CFM m³/h 60 Hz HP Û S P IP54 167 Representatives Pa [in H2O] AC axial fans RG 90-18/50 DC fans - specials Series RG 90 DC axial fans AC centrifugal fans ACmaxx / i-maxx 54 m3/h max. 94 m3/h max. AC centrifugal fans Series RG 125 180 x 180 x 40 mm Nominal voltage Frequency Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 at 40 °C CFM V Hz Bel(A) / Watts RPM °C Hours RG 125-19/56 86 50,6 230 50 5,8 / 20,0 2 550 -30...+70 37 500 / 20 000 1 RG 125-19/06 94 55,3 115 60 6,0 / 19,0 2 750 -30...+80 40 000 / 15 000 2 Pa [in H2O] Type 2 200 1 0,4 0,6 100 50 0,2 150 0 10 20 20 30 40 40 50 Hz 168 HP 50 80 60 CFM m³/h 60 Hz Û S P IP54 Curve Air flow m3/h Nominal data at T max Air flow – AC centrifugal fan with external rotor shaded-pole motor. Impedance protected against overloading. – Spiral housing and impeller of fibreglass-reinforced plastic. Housing base of galvanised steel plate. – Direction of air flow radial, through housing port. Direction of rotation clockwise, seen on rotor. – Electrical connection via 2 leads AWG 22. Bared and tin-plated. – Mass: 850 g. Hours Information Series RG 160 220 x 220 x 56 mm TypType dB(A) Bel(A) Bel / / Watts Watts RPM RPM Curve DC centrifugal fans °C °C at T max Service life L10 at 40 °C Temperature range Nominal speed Power input Sintec sleeve bearings Ball bearings Sound power level Frequency Hz Hz Nominal data Air flow 3/s V DCV m3m /h3/h10-3 m CFM Air flow Nominal voltage – AC centrifugal fan with external rotor shaded-pole motor. Thermal contactor as protection against thermal overloading. – Spiral housing and impeller of fibreglass-reinforced plastic. Housing base of galvanised steel plate. – Direction of air flow radial, through housing port. Direction of rotation counter-clockwise, seen on rotor. – Electrical connection via leads AWG 18. Bared and tin-plated. – Mass: 1.7 kg. DC axial fans AC centrifugal fans Hours Hours Hours Hours 202 118,9 230 50 6,6 / 47,0 2 750 -30...+70 30 000 / 15 000 1 RG 160-28/06S 223 131,3 115 60 6,9 / 50,0 3 050 -30...+80 27 500 / 12 500 2 AC centrifugal fans [in H2O] Pa AC axial fans ACmaxx / i-maxx RG 160-28/56S DC fans - specials 223 m3/h max. 2 400 0 20 40 50 60 100 80 100 120 200 150 50 Hz CFM m³/h 60 Hz HP Û S P IP54 169 Representatives 0,8 100 Accessories 1 1,2 200 0,4 300 115 m3/h max. AC centrifugal fans Series RER 125 138 Ø x 40 mm Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 at 40 °C CFM V Hz Bel(A) / Watts RPM °C Hours RER 125-19/56 104 61,2 230 50 6,2 / 19,0 2 600 -30...+60 37 500 / 22 500 1 RER 125-19/06 115 67,7 115 60 6,5 / 18,0 2 850 -30...+70 40 000 / 20 000 2 Pa [in H2O] The air flow and noise level of fans without external housing depend on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 220 x 220 mm. Cover plate 220 x 220 mm with an air inlet of Ø 86 mm, concentric to the impeller. 2 100 80 0,3 1 0,2 60 0,1 40 20 0 10 20 20 30 40 40 60 50 80 50 Hz 170 HP 60 CFM 100 m³/h 60 Hz Û S P IP54 Curve Frequency m3/h Nominal data at T max Nominal voltage Type Air flow Air flow – AC centrifugal fan with external rotor shaded-pole motor. Impedance protected against overloading. – Impeller of fibreglass-reinforced plastic, with steel plate reinforced. – Direction of air flow radial. Direction of rotation clockwise, seen on rotor. – Electrical connection via leads AWG 22. Bared and tin-plated. – Mass: 500 g. Hours Information AC centrifugal fans Series RER 160 176 Ø x 54 mm TypType dB(A) Bel(A) Bel / / Watts Watts RPM RPM DC axial fans Curve DC centrifugal fans °C °C at T max Service life L10 at 40 °C Temperature range Nominal speed Power input Sintec sleeve bearings Ball bearings Hz Hz Sound power level Frequency Nominal data Air flow 3/s V DCV m3m /h3/h10-3 m CFM Air flow Nominal voltage – AC centrifugal fan with external rotor shaded-pole motor. Impedance protected against overloading. – Impeller of fibreglass-reinforced plastic, with steel plate reinforced. – Direction of air flow radial. Direction of rotation counter-clockwise, seen on rotor. – Electrical connection via leads AWG 18. Bared and tin-plated. – Mass: 1.0 kg. Hours Hours Hours Hours 234 137,7 230 50 6,6 / 45,0 2 800 -30...+60 30 000 / 20 000 1 RER 160-28/06S 274 161,3 115 60 6,8 / 46,0 3 250 -30...+70 30 000 / 15 000 2 ACmaxx / i-maxx RER 160-28/56S DC fans - specials 274 m3/h max. AC axial fans AC centrifugal fans Pa [in H2O] The air flow and noise level of fans without external housing depend on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 260 x 260 mm. Cover plate 260 x 260 mm with an air inlet of Ø 100 mm, concentric to the impeller. 2 250 Accessories 50 0 30 60 50 100 90 150 120 200 50 Hz 150 250 CFM m³/h 60 Hz HP Û S P IP54 171 Representatives 0,4 0,6 100 0,2 150 0,8 1 200 172 Information Fan filter guard grilles 180 Inlet nozzles 182 Connection cables / Accessories 183 DC axial fans 174 AC axial fans ACmaxx / i-maxx DC fans - specials Guard grilles DC centrifugal fans Accessories Accessories AC centrifugal fans Everything that you need for your fan. ebm-papst provides an extensive range of accessories for optimum fan operation: From temperature sensing for speedcontrolled fans to finger guards of all types, switched-mode power supply, connecting cable, filter, screens, spacers and assembly parts. In addition to the accessories and assembly parts listed in this catalogue, ebm-papst also supplies numerous special parts for fan operation. The sales experts at ebm-papst will be happy to assist you in your enquiries concerning fan assembly and application. 173 Representatives From selection to accessories: Insist on the efficient and reliable service provided by ebm-papst. Guard grilles – Guard grille acc. to DIN EN ISO 13857 (previously EN 294), made of galvanised or nickelplated and passivated steel wire for device fans. – Additional guard grilles that do not conform to DIN EN ISO 13857 are available on request. – Our guard grilles are specially designed for use with ebm-papst fans. Their design ensures maximum safety with minimum effect on the operating noise level. Note that when using guard grilles from other manufacturers, compliance with safety-related distances will not always be present. Fan series Guard grilles Fan series Guard grilles Fan series Guard grilles 400 LZ29-1 5600 LZ25 DV 6200 LZ37 Intake side 500 LZ31 5200 LZ35 DV 6200 LZ39 Outlet side 600 LZ28-1 5300 LZ53 DV 6400 LZ38 Intake side 3000 LZ23-1 5900 LZ35 DV 6400 LZ39 Outlet side 8000 LZ32-4 / LZ22-2 7000 LZ36 9000 LZ30-4 / LZ 30 6300 LZ37 4000 LZ30-4 / LZ 30 6400 LZ38 5100 LZ25 2200F LZ22 LZ29-1 Fan size 40 x 40 LZ31 Fan size 50 x 50 LZ28-1 Fan size 60 x 60 50 1,8 2 +0,3 4, 2± 4,5 0, 5 42 50 42 30+1 59 4,8 Fan size 92 x 92 LZ32-4 Fan size 80 x 80 LZ30-4 104,8 71,5 82,5 71,5 82,5 Fan size 119 x 119 2 + 0,3 2+0,3 40+1 _ 92 1 174 0, 4,7+1 3+ 40+1 78,2 ±0,5 2 4, 4,7+1 4, 4, 3+ 0, 2 3+ 0, 2 2 + 0,3 104,8 LZ23-1 4,2 +0,5 51,5 +1 _ 119 1 4,7+1 Information Fan size 135 x 135 LZ35 Fan size 127 x 127 LZ36 Fan size 150 x 172 LZ37 Fan size 172 Ø x 51 LZ38 Fan size 172 Ø x 51 LZ39 Fan size 172 Ø x 51 LZ53 Fan size 140 x 140 LZ30 Fan size 119 x 119 LZ22-2 AC axial fans 78±1 48±1 105,5 +0,5 115 ±1 153,5 ±1 + 0,2 70 136,5 124,5 Fan size 80 x 80 3±0,25 4,3+0,2 + 6,45 2,5+0,3 5+1 2 0, AC centrifugal fans 4,3+0,2 5 LZ22 ACmaxx / i-maxx DC fans - specials DC centrifugal fans DC axial fans LZ25 +1 Fan size 200 x 51 8, 14 ( Accessories 199,5 + 0,5 186,5 ) 5 8,45 +1 175 Representatives 5 + 0,2 27,5 ACmaxx guard grilles – Guard grille acc. to DIN EN ISO 13857 (previously EN 294), made of galvanised or nickelplated and passivated steel wire for device fans. – The guard grilles shown on this page are designed specially for ACmaxx series fans and are installed on the outlet side. Fan series Guard grilles Fan series Guard grilles AC 8300 LZ32-4 Intake side s.P.174 AC 6200 N LZ37 Intake side s.P.175 AC 8300 H LZ32-7 Outlet side AC 6200 N LZ37-2 Outlet side AC 3200 J LZ23-1 Intake side s.P.174 AC 6100 N LZ37 Intake side s.P.175 AC 3200 J LZ23-6 Outlet side AC 6100 N * Outlet side AC 4400 FN LZ30-4 Intake side s.P.174 *Outlet-side grilles on request AC 4400 FN LZ30-9 Outlet side AC 4300 LZ30-4 Intake side s.P.174 AC 4300 LZ30-9 Outlet side ACi 4400 LZ30 Intake side s.P.175 ACi 4400 LZ30 Outlet side s.P.175 LZ30-9 Fan size 119 X 119 LZ37-2 Fan size 172 Ø X 51 LZ23-6 Fan size 92 x 92 82,5 + 0,2 51,5 89 2,5 2 +0,3 4, 3+ 0, 2 4,5 + 4,7+1 51,5 +1 119 -1 LZ32-7 Fan size 80 x 80 0,5 79,8 + 0,2 61,1 + 0,25 71,5 4,5 + 0,1 6,3 + 12,9 176 63,7 9 8, 15 104,8 Ø +0,5 162 ±0,3 104,8 0,3 + 0,3 4,3 ±0,2 6 ±0,5 0,1 7,3 Information Guard grilles W1G 250 09418-2-4039 W2E 250 09418-2-4039 W2E 200 78128-2-4039 78128-2-4039 Size 200 09418-2-4039 ACmaxx / i-maxx 78128-2-4039 Size 250 AC axial fans Guard grilles W4S 200 AC centrifugal fans Fan series 78128-2-4039 Accessories Guard grilles W1G 200 177 Representatives Fan series DC fans - specials DC centrifugal fans DC axial fans – Steel wire, plastic-coated, silver-metallic gloss. Guard grilles – Guard grille acc. to DIN EN ISO 13857 (previously EN 294), made of fibreglass-reinforced plastic. – Plastic grilles must not be used for the following models: 8200 JH3 / JH4 3200 JH3 / JH4 4100 NH5 - NH8 Guard grilles Mounting B C D E Guard grilles Mounting B C D E LZ32-2 A1 80-0,5 71,5±0,2 7,0 34 LZ30-5 A2 119-0,5 105±0,2 6,5 50 A3 80-0,5 71,5±0,2 A4 119-0,5 105±0,2 6,5 50 LZ23-2 A1 92,5-0,5 82,5±0,2 6,5 46 LZ33-1 A2 127-0,5 113,5±0,2 6,5 50 LZ23-3 A3 92,5-0,5 82,5±0,2 6,5 46 LZ33-2 A4 127-0,5 113,5±0,2 6,5 50 LZ32-3 7,0 34 LZ30-6 Screw connection LZ32-2 / LZ32-3 Size 80 x 80 LZ23-2 / LZ23-3 Size 92 x 92 LZ30-5 / LZ30-6 Size 119 x 119 LZ33-1 / LZ33-2 Size 127 x 127 Barbed inserts Suitable for bore diameters 4.3 - 4.7 only. LZ32P 178 Fan size 80 x 80 LZ30P Fan size 119 x 119 Information Guard grilles for compact centrifugal modules 9,0 RG 220 LZ47 166 8,7 RG 225 LZ48 158 8,7 a b ACmaxx / i-maxx 133 AC axial fans b LZ46 AC centrifugal fans Guard grilles Accessories a RG 190 179 Representatives Fan series DC fans - specials DC centrifugal fans DC axial fans – PA plastic 6, fibreglass-reinforced Fan filter guard grilles – – – – Fan series DC Fan series AC 4400 F AC 4300 4400 FN 9900 4300 4000 N 4300 N 4000 Z Filter guard grilles consist of a mounting plate, filter and screen. Screen LZ40 N made of black, fibreglass-reinforced plastic with inserted wire netting LZ60. Filter LZ60 made of Nirosta stainless steel wire netting. Mounting plate LZ40-1 for installation. 4400 4200 4100 N LZ40N 180 Screen LZ40-1 Bracket LZ60 Filter Fan size A B C D FF60 60 x 60 mm 65 65 13,5 50,0 Information Replacement filter* RF 60 FF80 80 x 80 mm 85 85 14,0 71,5 RF 80 FF92 92 x 92 mm 125 105 17,5 82,5 RF 92 FF119 119 x 119 mm 162 136 18,5 104,5 RF 119 FF172 ø 172 mm 226 190 19,5 162,0 RF 172 DC fans - specials Protection filter FF92 / FF 119 A C D A C D AC centrifugal fans D AC axial fans D D C B A 92 x 92 mm 119 x 119 mm FF 172 Accessories Filter capacity A fan filter guard filters out up to 75% of dust particles up to a size of 5-10 microns and withstands temperatures of up to 100°C. Flame retardant in accordance with DIN 53438, grade F1. For installed, clean filters, an air flow reduction of 20 – 30% can be assumed. ¯172 mm B Fan size: 181 Representatives Fan size: 60 x 60 mm 80 x 80 mm B Fan size: ACmaxx / i-maxx * Replacement filters only in packs of 5. FF60 / FF80 DC axial fans – Filter guard grille suitable for attachment to axial fan series of size 60 mm, 80 mm, 92 mm, 119 mm, ø 172 mm. All filter units fit directly onto the existing installation holes of the fans. – Filter guard grille consisting of 3 parts: outer grille barrier, inner fastening plate and replaceable filter mat. – Grille barrier made of moulded polycarbonate (PC), with matted surface. – Fast and easy exchange of filter mat via a quick release on the grille barrier. – Fastening plate made of wire netting, with black powder coating. – Filter mat can be replaced while the fan is running, protection provided by welded wire netting. – Filter mat made of white, synthetically bonded fibres. DC centrifugal fans Fan filter guard grilles Inlet nozzles for centrifugal fans – Material: Sheet steel, galvanised Fan Vers. k m o q r1 s t u No.: RET 97 (S) 1 116,0 80,0 10,0 0,80 10,0 108,0 3x4,5 – LZ 1000-097 RER 120 (P) 1 146,0 94,4 18,0 0,80 16,0 134,0 4x4,5 126,0 LZ 1000-120 RER 133 (P) 1 129,0 87,0 13,0 1,00 8,0 118,0 4x4,5 103,0 LZ 1000-133 RER 175 / 190 (P) 1 170,0 125,5 14,0 1,25 10,0 158,0 4x4,5 146,0 LZ 1000-175 RER 220 (P) 2 252,0 155,0 21,0 0,80 22,0 – – 199,0 LZ 1000-220 RER 225 (P) 1 223,0 146,0 28,0 1,50 25,0 210,0 4x4,5 196,0 LZ 1000-225 (P) = plastic, (S) = sheet steel Vers. 1 Vers. 2 45 118 ° 4, 5 24 Øs Øu Øk Øm 182 242 r1 q t 6x 60 ° 5,5 4 x 90° 3 0 Information Connector cables 610 LZ120-4 2 000 LZ120-5 380 LZ120-6 610 Leads DC axial fans Plug Leads end Lead colour Receptacle for tabs 0,5 mm2 0,5 mm2 G C black/black 2,8 x 0,5 Application AC G A black/black 2,8 x 0,5 AC 0,5 mm2 0,5 mm2 W B red/black 2,8 x 0,5 DC W B red/black 2,8 x 0,5 DC 0,5 mm2 0,5 mm2 G A red/black 2,8 x 0,5 DC G B black/black 2,8 x 0,5 AC G A black/black 2,8 x 0,5 AC LZ120-11 2 000 LZ120-16 800 LZ120-18 4 000 LZ126 1 000 0,5 mm2 0,5 mm2 G C black/black 2,8 x 0,5 AC LZ127 1 600 0,5 mm2 G B black/black 2,8 x 0,5 AC 0,82 mm2 0,73 mm2 G C black/black 2,8 x 0,5 AC G B black/black 2,8 x 0,8 AC LZ130-1 610 LZ140 610 10 AC centrifugal fans L1 Angled plug (W) 8 6 8,5 ±0,1 4 20 +0,5 8 L1 Leads end A Tin-plated Leads end B Core end sleeve Leads end C »Ø1,5 Core crimp sleeve 5,5 –0,25 »Ø1,5 7,5 6 10+5 –2 6 183 Accessories 31 3,5 –0,25 Connector cable 4 Representatives 22,5 AC axial fans 8,5 ±0,1 7,5 11 16 –0,5 2±0,2 Straight plug (G) 16,5 15 12 Connector cable DC centrifugal fans L1 (mm) LZ120 DC fans - specials Plug model Connector cable with injection-moulded plug in various lengths. Strand ends with core-crimping sleeve, core-end sleeve or tin-plated. Straight or angled plug. For all types of fan with flat plug 2.8 / 3.0 x 0.5. ACmaxx / i-maxx – – – – Accessories In addition to the accessories and assembly parts listed in this catalogue, ebm-papst also supplies numerous special parts for fans. The sales experts at ebm-papst will be happy to assist you in your enquiries concerning fan assembly and application. Fan series Accessories Fan series Accessories 8300 LZ212 / LZ260 5100 LZ210 8400 N LZ261 5600 LZ210 3300 LZ212 / LZ260 5200 LZ210 3400 N LZ261 5900 LZ210 9000 LZ210 7000 LZ210 4000 LZ210 VARIOFAN LZ370 4300 LZ212 / LZ260 8300 LZ212 LZ212 LZ260/LZ261 LZ210 Screw clip of stainless steel. For mounting fans with threaded pin 3.5 DIN EN ISO 1478 (7970). Spacer of fibreglass reinforced plastic. For screw mounting over both fan mounting flanges. Screw clip of hardened steel. For mounting fans with threaded pin 6-32 UNC and/or 3.5 DIN 7970. LZ370 LZ550 (2x) 0,5x45° Pmax = 0,25 W 5% @25°C 2% 50° = 4190 0,5 12 Temperature sensor for speed-controlled fan operation. Temperature range 30...50 °C. 184 6,9 ±0,1 11±0,3 (2x) Ø 4 = 100 K B-value Ø 11 R 25 Ø 6,6 Required performance data: Rubber anti-vibration mounts for fans with a hole ø of 4.3 ±0.2 mm and flange thickness of 3 - 5.5 mm. For a carrier plate with a hole ø of 6.5 ±0.15 mm and plate thickness of 1 - 2 mm. Representatives 185 Accessories AC centrifugal fans AC axial fans ACmaxx / i-maxx DC fans - specials DC centrifugal fans DC axial fans Information fan agent compact fan agent ebm-papst in Germany motor specialist motor agent Germany ebm-papst Mulfingen GmbH & Co. KG ebm-papst St. Georgen GmbH & Co. KG ebm-papst Landshut GmbH Bachmühle 2 D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1@de.ebmpapst.com Hermann-Papst-Straße 1 D-78112 St. Georgen Phone +49 7724 81-0 Fax +49 7724 81-1309 info2@de.ebmpapst.com Hofmark-Aich-Straße 25 D-84030 Landshut Phone +49 871 707-0 Fax +49 871 707-465 info3@de.ebmpapst.com www.ebmpapst.com www.ebmpapst.com www.ebmpapst.com Agencies Berlin Dipl.-Ing. (TH) Jens Duchow Händelstraße 7 D-16341 Panketal Phone +49 30 944149-62 Fax +49 30 944149-63 Jens.Duchow@de.ebmpapst.com Bielefeld Dipl.-Ing. (FH) Wolf-Jürgen Weber Niehausweg 13 D-33739 Bielefeld Phone +49 5206 91732-31 Fax +49 5206 91732-35 Wolf-Juergen.Weber@de.ebmpapst.com Dortmund Dipl.-Ing. (FH) Hans-Joachim Pundt Auf den Steinern 3 D-59519 Möhnesee-Völlinghausen Phone +49 2925 800-407 Fax +49 2925 800-408 Hans-Joachim.Pundt@de.ebmpapst.com Frankfurt Dipl.-Ing. Christian Kleffmann Dr.-Hermann-Krause-Straße 23 D-63452 Hanau Phone +49 6181 1898-12 Fax +49 6181 1898-13 Christian.Kleffmann@de.ebmpapst.com Halle Dipl.-Ing. (TU) Michael Hanning Lercheneck 4 D-06198 Salzatal / OT Lieskau Phone +49 345 55124-56 Fax +49 345 55124-57 Michael.Hanning@de.ebmpapst.com Hamburg Ingenieurbüro Breuell GmbH Ing. Dirk Kahl Elektroingenieur Grützmühlenweg 40 D-22339 Hamburg Phone +49 40 538092-19 Fax +49 40 538092-84 Dirk.Kahl@de.ebmpapst.com 186 Heilbronn / Heidelberg Dipl.-Ing. Mark Gartner Gehrweg 12 D-74199 Unterheinriet Phone +49 7130 404569-1 Fax +49 7130 404569-2 Mark.Gartner@de.ebmpapst.com Kassel Dipl.-Ing. (FH) Ralph Brück Hoherainstraße 3 b D-35075 Gladenbach Phone +49 6462 4071-10 Fax +49 6462 4071-11 Ralph.Brueck@de.ebmpapst.com Koblenz Winfried Schaefer Hinter der Kirch 10 D-56767 Uersfeld Phone +49 2657 16-96 Fax +49 2657 16-76 Winfried.Schaefer@de.ebmpapst.com Munich Dipl.-Wirt.-Ing. (FH) Jens Peter Uhlandstraße 6 D-74427 Fichtenberg Phone +49 7971 260-180 Fax +49 7971 260-221 Jens.Peter@de.ebmpapst.com Nuremberg Dipl.-Wirt.-Ing. (FH) Axel Resch Steinsfeldstraße 80 D-74626 Bretzfeld Phone +49 7946 94401-02 Fax +49 7946 94401-03 Axel.Resch@de.ebmpapst.com Offenburg Dipl.-Ing. (FH) Ralf Braun Hubeneck 21 D-77704 Oberkirch Phone +49 7802 9822-52 Fax +49 7802 9822-53 Ralf.Braun@de.ebmpapst.com Stuttgart Dipl.-Ing. (FH) Rudi Weinmann Hindenburgstraße 100/1 D-73207 Plochingen Phone +49 7153 9289-80 Fax +49 7153 9289-81 Rudi.Weinmann@de.ebmpapst.com Ulm M.Sc. Reinhard Sommerreißer Am Silbermannpark 10 D-86161 Augsburg Phone +49 821 6610-7023 Fax +49 821 6610-7024 Reinhard.Sommerreisser@de.ebmpapst.com Distributors Burgdorf ETB Electronic Team Beratungs- u. Vertriebs GmbH Wundramweg 1 31303 Burgdorf Phone +49 5136 97229-30 Fax +49 5136 97229-39 info@etb-electronic.de www.etb-electronic.de Frankfurt R.E.D. Handelsgesellschaft mbH Gutenbergstraße 3 D-63110 Rodgau - Jügesheim Phone +49 6106 841-0 Fax +49 6106 841-111 info@red-elektromechanik.de www.red-elektromechanik.de Arrow Central Europe GmbH Max-Planck-Straße 1-3 63303 Dreieich Phone +49 6103 304-8 Fax +49 6103 304-8562 spoerle@spoerle.e-mail.com www.spoerle.com Hamburg Breuell + Hilgenfeldt GmbH Grützmühlenweg 40 D-22339 Hamburg Phone +49 40 538092-20 Fax +49 40 538092-84 info@breuell-hilgenfeldt.de Walter Kluxen GmbH Neuer Höltigbaum 6 20097 Hamburg Phone +49 40 237010 Fax +49 40 23701309 Multi-Bauelemente-Service Vertrieb von elektr. Bauelementen GmbH Römerstraße 8 85661 Forstinning Phone +49 8121 2506-0 Fax +49 8121 2506-200 multi.bauelemente@mbs.to Belarus ebm-papst Bel AgmbH P.O. Box 117 BY-220138 Minsk Phone +375 17 3851556 Fax +375 17 3851556 info@by.ebmpapst.com www.ebmpapst.by North Breuell + Hilgenfeldt GmbH Grützmühlenweg 40 D-22339 Hamburg Phone +49 40 538092-20 Fax +49 40 538092-84 ebmpapst@breuell-hilgenfeldt.de South Scheffel elektrotechnischer Vertrieb GmbH Aischbach 1 70839 Gerlingen Phone +49 7156 28357 Fax +49 7156 49425 info@ebmpapst-service.de Belgium ebm-papst Benelux B.V. Sales office Belgium-Luxemburg Romeinsestraat 6/0101 Research Park Haasrode B-3001 Heverlee-Leuven Phone +32 16 396-200 Fax +32 16 396-220 info@be.ebmpapst.com www.ebmpapst.be Information Croatia ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 office@hu.ebmpapst.com Compex Ges.m.b.H Wurlitzergasse 10/3 A -1160 Wien Phone +43 1 4804223 Fax +43 1 4864230 compex.wien@utanet.at Czech Republic / Slovakia ebm-papst CZ s.r.o. Kaštanová 34a CZ-620 00 Brno Phone +420 544 502-411 Fax +420 547 232-622 info@ebmpapst.cz www.ebmpapst.cz Avnet Time Diegem Eagle Building Kouterveldstraat 20 B-1831 Diegem Phone +32 27 099003 Fax +32 27 099801 TimeBe@avnet.com www.avnettime.com Accessories (1 to 5 pieces) DC fans - specials Avnet Time Vienna Diefenbachgasse 35/2 A-1150 Vienna Phone +43 1 8664 20 Fax +43 1 8664 2250 TimeAustria@avnet.com www.avnettime.com ACmaxx / i-maxx Munich A. Schweiger GmbH Ohmstraße 1 D-82054 Sauerlach Phone +49 8104 897-0 Fax +49 8104 897-90 info@schweiger-gmbh.de www.schweiger-gmbh.com Compex Ges.m.b.H Wurlitzergasse 10/3 A -1160 Wien Phone +43 1 4804223 Fax +43 1 4864230 compex.wien@utanet.at AC axial fans Austria ebm-papst Motoren & Ventilatoren GmbH Straubingstraße 17 A-4030 Linz Phone +43 732 321150-0 Fax +43 732 321150-20 info@at.ebmpapst.com www.ebmpapst.at Bulgaria ebm-papst Romania S.R.L. Str. Tarnavei Nr. 20 RO-500327 Brasov Phone +40 268 312-805 Fax +40 268 312-805 dudasludovic@xnet.ro AC centrifugal fans Europe 187 Representatives Klausdorf ETB Electronic Team Beratungs- u. Vertriebs GmbH Zossener Straße 27 15838 Klausdorf Phone +49 33703 69-0 Fax +49 33703 69-149 info@etb-electronic.de www.etb-electronic.de DC centrifugal fans DC axial fans ebm-papst in Germany and Europe fan agent compact fan agent ebm-papst in Europe motor specialist motor agent Denmark ebm-papst Denmark ApS Vallensbækvej 21 DK-2605 Brøndby Phone +45 43 631111 Fax +45 43 630505 mail@dk.ebmpapst.com www.ebmpapst.dk Estonia ebm-papst Oy, Eesti Filiaal Kesk tee 13 Aaviku küla, Jüri Tehnopark EST-75301 Rae Vald, Harjumaa Phone +372 65569-78 Fax +372 65569-79 www.ebmpapst.ee Finland ebm-papst Oy Puistotie 1 FIN-02760 Espoo Phone +358 9 887022-0 Fax +358 9 887022-13 mailbox@ebmpapst.fi www.ebmpapst.fi France ebm-papst SARL ZI Nord - rue A. Mohler BP 62 F-67212 Obernai-Cedex Phone +33 820 326266 Fax +33 3 88673883 info@ebmpapst.fr www.ebmpapst.fr Greece Helcoma Th. Rotas & Co OE Davaki 65 GR-17672 Kallithea-Attiki Phone +30 210 9513-705 Fax +30 210 9513-490 contact@helcoma.gr www.helcoma.gr Assimacopoulos S.A. 11, Karitsi Square GR-10561 Athen Phone +30 10 322 1737 Fax +30 10 322 5708 assimac@interagora.gr www.assimacopoulos.gr 188 Hungary ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 office@hu.ebmpapst.com Macedonia ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 office@hu.ebmpapst.com Compex KFT. Elete út 56/B H-1115 Budapest Phone +36 12 0657 25 Fax +36 12 0657 71 compex@vnet.hu Netherlands ebm-papst Benelux B.V. Engelseweg 127 NL-5705 AC Helmond Phone +31 492 502-900 Fax +31 492 502-950 verkoop@nl.ebmpapst.com www.ebmpapst.nl Iceland RJ Engineers Stangarhyl 1a IS-110 Reykjavik Phone +354 567 8030 Fax +354 567 8015 rj@rj.is www.rj.is Ireland ebm-papst UK Ltd. Chelmsford Business Park GB-Chelmsford Essex CM2 5EZ Phone +44 1245 468555 Fax +44 1245 466336 sales@uk.ebmpapst.com www.ebmpapst.co.uk AuBren Limited Portlaoise Business & Technology Park Mountrath Road IRL-Portlaoise, Co. Laois Phone +353 57 8664343 Fax +353 57 8664346 sales@ie.aubren.com www.aubren.com Italy ebm-papst Srl Via Cornaggia 108 I-22076 Mozzate (Co) Phone +39 0331 836201 Fax +39 0331 821510 info@it.ebmpapst.com www.ebmpapst.it Avnet Time Breda Takkebijsters 2 NL-4817 BL Breda Phone +31 765 722300 Fax +31 765 722303 Time NL@avnet.com www.avnettime.com Norway ebm-papst AS P.B. 173 Holmlia N-1203 Oslo Phone +47 22 763340 Fax +47 22 619173 mailbox@ebmpapst.no www.ebmpapst.no Poland ebm-papst Polska Sp. z o.o. ul. Annopol 4A PL-03236 Warszawa Phone +48 22 6757819 Fax +48 22 6769587 office@ebmpapst.pl www.ebmpapst.pl Compex Ges.m.b.H Wurlitzergasse 10/3 A -1160 Wien Phone +43 1 4804223 Fax +43 1 4864230 compex.wien@utanet.at ebm-papst Rus GmbH proezd 4529, vladenie 5, stroenie 1 RU-141000 Mytistschi, Oblast Moskau Phone +7 495 9807524 Fax +7 495 5140924 info@ebmpapst.ru www.ebmpapst.ru Serbia & Montenegro ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 office@hu.ebmpapst.com Information DC fans - specials ACmaxx / i-maxx AC axial fans Russia ebm-papst Ural GmbH Posadskaja-Strasse, 23(E), 3 RU-620102 Ekaterinburg Phone +7 343 2338000 Fax +7 343 2337788 Konstantin.Molokov@ru.ebmpapst.com www.ebmpapst.ur.ru Switzerland ebm-papst AG Rütisbergstrasse 1 CH-8156 Oberhasli Phone +41 44 73220-70 Fax +41 44 73220-77 verkauf@ebmpapst.ch www.ebmpapst.ch ebm-papst Automotive & Drives (UK) Ltd. The Smithy Fidlers Lane GB-East Ilsley, Berkshire RG20 7LG Phone +44 1635 2811-11 Fax +44 1635 2811-61 A&Dsales@uk.ebmpapst.com www.ebmpapst-ad.com Omni Ray AG Im Schörli 5 CH-8600 Dübendorf Phone +41 44 802 2880 Fax +41 44 802 2828 r.borner@omniray.ch www.omniray.ch AC centrifugal fans Compex Ges.m.b.H Wurlitzergasse 10/3 A -1160 Wien Phone +43 1 4804223 Fax +43 1 4864230 compex.wien@utanet.at Sweden ebm-papst AB Äggelundavägen 2 S-17562 Järfälla Phone +46 8 7619400 Fax +46 8 362306 info@ebmpapst.se www.ebmpapst.se United Kingdom ebm-papst UK Ltd. Chelmsford Business Park GB-Chelmsford Essex CM2 5EZ Phone +44 1245 468555 Fax +44 1245 466336 sales@uk.ebmpapst.com www.ebmpapst.co.uk Turkey Akantel Elektronik San. Tic. LTD. Sti. Atatürk Organize Sanayi Bölgesi 10007 SK. No.:6 TR-35620 Cigli-Izmir Phone +90 232 3282090 Fax +90 232 3280270 akantel@akantel.com.tr www.ebmpapst.com.tr Ukraine ebm-papst Ukraine LLC Lepse Boulevard, 4, Building 47 UA-03067 Kiev Phone +38 044 2063091 Fax +38 044 2063091 mail@ebmpapst.ua www.ebmpapst.ua Accessories Romania ebm-papst Romania S.R.L. Str. Tarnavei Nr. 20 RO-500327 Brasov Phone +40 268 312-805 Fax +40 268 312-805 dudasludovic@xnet.ro Spain ebm-papst Ibérica S.L. Avda. del Sistema Solar, 29 E-28830 San Fernando de Henares (Madrid) Phone +34 91 6780894 Fax +34 91 6781530 ventas@ebmpapst.es 189 Representatives Portugal ebm-papst (Portugal), Lda. Centro Empresarial de Alverca Rua de Adarse, Vale D’Ervas Corpo D / Fracção 3 P-2615-178 Alverca do Ribatejo Phone +351 218 394 880 Fax +351 218 394 759 info@pt.ebmpapst.com www.ebmpapst.pt DC centrifugal fans DC axial fans ebm-papst in Europe fan agent compact fan agent ebm-papst in America, Africa and Asia motor specialist motor agent America Argentina ebm-papst de Argentina S.A. Hernandarias 148 Lomas del Mirador Pcia. de Buenos Aires (1752) Phone +54 11 46576135 Fax +54 11 46572092 ventas@ar.ebmpapst.com www.ebmpapst.com.ar Brasil ebm-papst Motores Ventiladores Ltda. Av. José Giorgi, 301 Galpões B6+B7 Condominio Logical Center BR-06707-100 Cotia - São Paulo Phone +55 11 4613-8700 Fax +55 11 3164-8924 vendas@br.ebmpapst.com www.ebmpapst.com.br Canada ebm-papst Canada Inc. 1800 Ironstone Manor, Unit 2 CDN-Pickering, Ontario, L1W3J9 Phone +1 905 420-3533 Fax +1 905 420-3772 sales@ca.ebmpapst.com www.ebmpapst.ca Mexico ebm Industrial S.de R.L. de C.V. Paseo de Tamarindos 400-A-5to Piso Col. Bosques de las Lomas MEX-Mexico 05120, D.F. Phone +52 55 3300-5144 Fax +52 55 3300-5243 sales@mx.ebmpapst.com www.ebmpapst.com.mx USA ebm-papst Inc. P.O. Box 4009 100 Hyde Road USA-Farmington, CT 06034 Phone +1 860 674-1515 Fax +1 860 674-8536 sales@us.ebmpapst.com www.ebmpapst.us ebm-papst Automotive & Drives, Inc. 3200 Greenfield, Suite 255 USA-Dearborn, MI 48120 Phone +1 313 406-8080 Fax +1 313 406-8081 automotive@us.ebmpapst.com www.ebmpapst-automotive.us Africa South Africa ebm-papst South Africa (Pty) Ltd. P.O. Box 3124 1119 Yacht Avenue ZA-2040 Honeydew Phone +27 11 794-3434 Fax +27 11 794-5020 info@za.ebmpapst.com www.ebmpapst.co.za Retron CC P.O. Box 3 94 48, Bramley, 2018 SSF-Building, 706 - 4th Street, Wynberg ZA-Johannesburg Phone +27 11 7860553 Fax +27 11 4408275 Asia China ebm-papst Ventilator (Shanghai) Co., Ltd. No. 418, Huajing Road WaiGaoQiao Free Trade Zone No. 2001, Yang Gao (N) Road VRC-200131 Shanghai, P.R. of China Phone +86 21 5046-0183 Fax +86 21 5046-1119 sales@cn.ebmpapst.com www.ebmpapst.com.cn Hong Kong ebm-papst Hong Kong Ltd. Unit No. 13,9 / F Technology Park, 18 On Lai Street Siu Lek Yuen, Shatin N.T. Hong Kong - P.R. of China Phone +852 2145-8678 Fax +852 2145-7678 info@hk.ebmpapst.com India ebm-papst India Pvt. Ltd. 26/3, G.N.T. Road, Erukkencherry IND-Chennai-600118 Phone +91 44 25372556 Fax +91 44 25371149 sales@in.ebmpapst.com www.ebmpapst.in Indonesia ebm-papst Indonesia Representative Office German Centre, 4th Floor, Suite 4470 Jl. Kapt. Subijono Dj. Bumi Serpong Damai RI-15321 Tangerang Phone +62 21 5376250 Fax +62 21 5388305 salesdept@id.ebmpapst.com Israel Polak Bros. Import Agencies Ltd. 9 Hamefalsim Street IL-Kiryat Arie, Petach-Tikva 49514 Phone +972 3 9100300 Fax +972 3 5796679 polak@polak.co.il www.polak.co.il 190 Malaysia ebm-papst Malaysia Representative Office Unit 12-2, Jalan USJ Sentral 3 Persiaran Subang, Selangor Darul Ehsan MAL-47600 Subang Jaya Phone +60 3 8024-1680 Fax +60 3 8024-8718 salesdept@my.ebmpapst.com Information DC fans - specials Australia ebm-papst A&NZ Pty Ltd. 10 Oxford Road AUS-Laverton North, Victoria, 3026 Phone +61 3 9360-6400 Fax +61 3 9360-6464 sales@ebmpapst.com.au www.ebmpapst.com.au New Zealand ebm-papst A&NZ Pty Ltd. 102 Henderson Valley Road NZ-Henderson, Auckland 1230 Phone +64 9 837-1884 Fax +64 9 837-1899 sales@ebmpapst.com.au www.ebmpapst.com.au ACmaxx / i-maxx United Arab Emirates ebm-papst Middle East FZE PO Box 17755 Jebel Ali Free Zone / FZS1 / AP05 UAE-Dubai Phone +971 4 88608-26 Fax +971 4 88608-27 info@ae.ebmpapst.com www.ebmpapst.ae Australia Vietnam ebm-papst Vietnam Representative Office Room #102, 25 Nguyen Van Thu Street District 1 VN-Ho Chi Minh City Phone +84 8 39104099 Fax +84 8 39103970 linh.nguyen@vn.ebmpapst.com AC axial fans Korea ebm-papst Korea Co. Ltd. 6F, Trutec Bldg. B 6-2, Digital Media City (DMC) Sangam-Dong, Mapo-Gu ROK-Seoul 121-270 Phone +82 2 366213-24 Fax +82 2 366213-26 info@kr.ebmpapst.com www.ebmpapst.co.kr Thailand ebm-papst Thailand Co., Ltd. 99/349 Na-Nakorn Bldg., 4th Floor Chaeng Wattana Road, Thungsonghong, THA-10210 Laksi, BKK Phone +66 2 57615-24 Fax +66 2 57615-42 salesdept@th.ebmpapst.com AC centrifugal fans Singapore ebm-papst SEA Pte. Ltd. No. 23 Ubi Road 4 #06-00 Olympia Industrial Building SGP-Singapore 408620 Phone +65 65513789 Fax +65 68428439 salesdept@sg.ebmpapst.com Accessories Taiwan ETECO Engineering & Trading Corp. 10F-I, No. 92, Teh-Wei Str. RC-Tsow-Inn District, Kaohsiung Phone +886 7 557-4268 Fax +886 7 557-2788 eteco@ms22.hinet.net www.ebmpapst.com.tw 191 Representatives Japan ebm-papst Industries Japan K.K. 12 Floor, Benex S-3 Bldg. 3-20-8 Shinyokohama, Kohoku-ku J-222-0033 Yokohama Phone +81 45 47057-51 Fax +81 45 47057-52 info@jp.ebmpapst.com www.ebmpapst.jp DC centrifugal fans DC axial fans ebm-papst in Asia and Australia 37634-7-8811 · RA-12/10-10’ L1136 · 980 0000 047 Printed in Germany ebm-papst ebm-papst ebm-papst St. Georgen GmbH & Co. KG Mulfingen GmbH & Co. KG Landshut GmbH Hermann-Papst-Straße 1 Bachmühle 2 Hofmark-Aich-Straße 25 D-78112 St. Georgen D-74673 Mulfingen D-84030 Landshut Phone +49 7724 81-0 Phone +49 7938 81-0 Phone +49 871 707-0 Fax +49 7724 81-1309 Fax +49 7938 81-110 Fax +49 871 707-465 info2@de.ebmpapst.com info1@de.ebmpapst.com info3@de.ebmpapst.com www.ebmpapst.com

很抱歉,暂时无法提供与“FF80”相匹配的价格&库存,您可以联系我们找货

免费人工找货