Compact fans for AC and DC
The engineer’s choice
version 2011
Trendsetter in fan technology
Uncompromising quality
made by ebm-papst
Among the best.
Trendsetting with innovative technologies. Listening to customers’ needs.
Developing new ideas to meet requirements and realising them with
pioneering spirit. This philosophy has made ebm-papst the technological
leader in the world of fans.
A brand which has very little real competition because every fan is a
product of decades of application expertise gained from large-volume
production and because we are in a position to produce highly efficient
quality products. Our intelligent solutions for electronics cooling ensure
that you are one step ahead of competitors thanks to innovative, reliable
top-quality technology which is cost-favourable and in line with market
requirements. And if required, tailor-made right down to the last detail. In
other words, if you need fans which do not yet actually exist, contact us.
Insist on ebm-papst.
2
Information
DC axial fans
DC fans - specials
– Speed signal
– Alarm signal
– Vario-Pro®
– Speed setting
– Protected fans
110
114
119
120
123
ACmaxx / i-maxx
– Axial fans
125
AC axial fans
– Axial fans
141
AC centrifugal fans
– Centrifugal fans
163
Accessories
– Guard grilles
– Filter guard grilles
– Inlet nozzles
– Connection cables
– Accessories
174
180
182
183
184
ebm-papst representatives & subsidiaries
186
3
DC centrifugal fans
75
105
DC fans - specials
DC centrifugal fans
– Centrifugal fans
– Tangential fans
ACmaxx / i-maxx
17
AC axial fans
DC axial fans
– Axial fans
AC centrifugal fans
4
6
8
10
12
13
14
15
16
Accessories
Information
– The company
– GreenTech: The Green Company
– Expertise and technology
– Tailor-made
– Types of fans
– Selecting the correct fan
– Fan installation
– Service life
– Definitions
Representatives
Table of contents
Company profile: ebm-papst
The entire scope of ventilation and drive technology: this is the world of ebm-papst. More than 10,000 people – in
Germany and throughout the world – develop, produce and sell our motors and fans. Our global presence and
our unique range of products based on a quality standard that surpasses every other have made us what we are:
world market leader in motors and fans. Expertly knowing what our customers need and incessantly striving
to arrive at the perfect application solution for a wide variety of different industries is what determines our daily
work. Those who know us know the high standards we apply to our work and know our creed: to be as close
to our customers as possible and to simply be the best in terms of innovation and reliability.
Our location in St. Georgen
4
Information
DC axial fans
Left:
DC centrifugal fans
Our headquarters in Mulfingen
Right:
clearance for serial production only after all the
Rooted in ebm, PAPST and mvl, the three leading innovators in the
desired characteristics have been determined to
development and production of motors and fans, ebm-papst has
be just right.
established itself as the world market leader. Now as ever, our legendary
Environmental care is another priority with
inventive spirit shines through in products that set standards in many
ebm-papst. This is why we have developed
segments of industry worldwide. We are proud to say that despite difficult
our product line in EC technology, which makes
competition, our performance has always been exemplary and outstand-
for very low power consumption. Due to our
ing – in business, in our personal relationship with our customers, and of
manufacturing philosophy, there is absolute
course with respect to technology and engineering. For decades, we have
focus on environmental care in production,
contributed to the world of air technology and drive engineering with
recycling, waste and wastewater disposal.
ACmaxx / i-maxx
Our history – Our drive
DC fans - specials
Our location in Landshut
small revolutions and large milestones.
To maintain this advantage in skills and knowledge to get maximum
Global Domestic
quality and thus the highest degree of customer satisfaction, our
In order to be specialist for customised solutions
employees around the world put their passion and dedication to work
throughout the world, you need strong partners.
for you.
Global Domestic – i.e. being present all over the
ourselves in all important markets on this globe
products of highest quality and reliability. After all, it is our passion to
with our successful subsidiaries. And so you will
constantly try something new and improve what we have. In doing so,
always find ebm-papst close to home, speaking
we take advantage of the latest development methods and state-of-
your language, and knowing the demands of
the-art technology and invest quite heavily in R&D facilities. Best of all,
your markets. Besides, our worldwide produc-
though, we rely on excellently trained and skilled engineers and
tion alliance serves as a basis for competitive
technicians to be at your service in R&D and Sales & Distribution.
pricing. Our global services and logistic outlets,
AC centrifugal fans
Our catalogues just list the results of our incessant efforts in R&D:
i.e. IT networking, safeguard short reaction
Producing and safeguarding high-quality products and services
times and just-in-time delivery.
our six factories in Germany or one of our eleven international production
All our efforts are documented in a comprehen-
sites, our products always have the same high level of quality. This quality
sive quality management system, both for prod-
control is something you can definitely rely on! And this across all levels
ucts and services. Being certified as complying
of production and throughout all processes: consulting customers, devel-
with the tough requirements of the international
opment, material selection through to picking certified, choice suppliers
standards DIN EN ISO 9001, ISO/TS 16949-2
and on to the production of parts and final delivery. On top of this, our
and of standard DIN EN ISO 14001 is just one
products have to pass the most rigorous tests under all realistic operating
seal of approval we have received for our
conditions: continuous stress test, salt spray test, vibration test, or preci-
unceasing efforts to provide only the best
sion noise measuring, just to mention a few. And the product gets
quality products and services.
Accessories
This is our promise without any compromise. Whether produced in one of
5
Representatives
individual country – is how we have established
AC axial fans
world and being a national company in each
Passionately involved in R&D
Sustainability is at the centre of our
thoughts and actions. Out of conviction!
Eco-friendliness and sustainability have always been at the core of our thoughts and actions. For decades, we have worked
according to the simple but strict creed of our co-founder Gerhard Sturm: “Each new product we develop has to be better
than the last one in terms of economy and ecology.” GreenTech is the ultimate expression of our corporate philosophy.
Information
DC axial fans
DC centrifugal fans
DC fans - specials
ACmaxx / i-maxx
GreenTech is acknowledged and certified.
Even in the design phase, the materials and processes we use are optimi-
Every step in our chain of production meets the stringent standards of
sed for the greatest possible eco-friendliness, energy balance and –
environmental specialists and the public. The 2008 Environmental Prize
wherever possible – recyclability. We continually improve the material
of Baden-Wuerttemberg, the Green Award 2009, the Energy Efficiency
and performance of our products, as well as the flow and noise charac-
Award 2009 of the dena – to give just a few examples – testify to this.
teristics. At the same time, we significantly reduce energy consumption.
The environmental advantage gained in the performance of the products
Close co-operation with universities and scientific institutes and the pro-
developed from our GreenTech philosophy can also be measured in the
fessorship we endow in the area of power engineering and regenerative
fulfilment of the most stringent energy and environmental standards.
energies allows us to profit from the latest research findings in these
In many instances, our products are already well below the thresholds
fields – and at the same time ensure highly qualified young academics.
energy legislation will impose a few years from now – several times over.
GreenTech is eco-friendly production.
Our customers profit from this every day.
GreenTech also stands for maximum energy efficiency in our production
The heart of GreenTech is future-oriented EC technology from ebm-
processes. There, the intelligent use of industrial waste heat and ground-
papst. The EC technology at the core of our most efficient motors and
water cooling, photovoltaics and, of course, our own cooling and venti -
fans allows efficiency of up to 90%, saves energy at a very high level,
lation technology are of the utmost importance. Our most modern plant,
significantly extends service life and makes our products maintenance-
for instance, consumes 91% less energy than currently specified and
free. These values pay off not only for the environment, but every cent al-
required. In this way, our products contribute to protecting the environ-
so pays off for the user! All ebm-papst products – even those for which
ment, from their origin to their recyclable packaging.
GreenTech EC technology does not (yet) make sense from an application
viewpoint – feature the greatest possible connection of economy and
Accessories
AC centrifugal fans
AC axial fans
GreenTech is pro-active development.
7
Representatives
ecology.
Expertise and technology
Drive expertise
Long service life
For the past 60 years, all conceivable types and applications of drive
The bearing system plays a vital role both in
engineering have played an essential role at ebm-papst. A commitment
the long life time and quietness of device
that is the foundation for the development of optimum drive solutions –
fans. The SINTEC compact bearing provides
regardless of the type of fan and its usage. DC fans are generally
most of the device fans with a proven bearing
equipped with electronically commutated external rotor motors; in
system. Constant low noise during the entire
order to save as much space as possible, commutation electronic com-
operating time and considerably lower shock
ponents are integrated in the hub of the fan. Our AC fans are mostly
sensitivity are the outstanding features of this
driven by shaded-pole or capacitor motors based on the external rotor
bearing technology. In addition, with regard
principle. In the 3900 and 9900 range of particularly slim fans, internal
to temperature endurance, Sintec compact
rotor motors are used.
bearings can be used without problems in
most applications. Despite the slightly higher
Low-noise performance
noise and shock sensitivity of ball bearings,
Our aerodynamically optimised design and high mechanical precision
this bearing technology should be given pref-
produces outstanding noise properties in series production. So-called
erence for fans exposed to extreme thermal
“soft” commutation electronics of the DC fans ensure an excellent
and adverse application conditions (e.g.
noise performance. By avoiding steep switching edges when the indi-
extreme environmental conditions, critical
vidual coils are switched, this reduces the structure-borne noise from
installation position, etc.). The service life data
the motor. Computer-aided measurements and series of analyses per-
provided in this catalogue is based on exten-
formed in a state-of-the-art sound measuring chamber are conducted
sive service life tests and mathematically /
on each fan model from the very beginning.
scientifically proven service life calculations.
Our product descriptions are continuously
updated with all relevant data obtained from
long-term tests.
8
Information
DC axial fans
DC centrifugal fans
Safety is included
It goes without saying that all ebm-papst fans
DC fans - specials
conform to the approval requirements of the
VDE (Association of German Electrical Engineers)
and the standards and regulations of UL and
CSA. All fans conform to the European Standard
EN 60335 or EN 60950 plus those of the UL
(Underwriters Laboratories) and CSA (Canadian
Standards Association).
to meet the requirements of protection class 3
With the aid of state-of-the-art computer programs, we are able to
/ protection class voltage. ACmaxx fans are
optimise the fan impellers and the inner shape of the housing. Air
protection class 2 / AC fans are protection
output and available motor performance are exactly matched with the
class 1. ebm-papst fans meet the highest
size of fan. This guarantees the low noise that is typical for ebm-papst,
requirements of electrical safety. Depending on
even at high back pressure.
the type, they are either impedance protected
ACmaxx / i-maxx
With few exceptions, our DC fans are designed
Streamline: Aerodynamics
Sturdy construction – in metal or plastic
electronic locked-rotor protection, alarm func-
Fans of all-metal construction: Sturdy and indestructible. The housing
tion or have speed monitoring and speed con-
is made of an aluminium alloy whereas the metal surfaces that are
trol.
AC axial fans
or equipped with a temperature safety switch,
Quality in detail
sion is highly recyclable. Fans with fibreglass-reinforced plastic hous-
It is the seemingly trivial that makes the
ing and impeller: Excellent stability and low weight distinguish
difference when a product is labelled ‘made
this highly efficient fan concept. Combinations of metal housing and
by ebm-papst’: consistent maintenance of
plastic impeller unite the advantages of both types of design.
development and design engineering specifica-
Product images
quality across the entire process chain are the
The dimensioned drawings and product photos that appear in the catalo-
reasons why running times of over 150,000
gue are for orientation purposes and may differ in some details from the
hours are not unusual. The no-compromise
actual product design.
ebm-papst quality assurance spans over all
Accessories
tions; target-oriented design; and assured
process levels – from the choice of materials
Product liability
and the use of carefully selected, certified sup-
Motors and fans from ebm-papst are components intended for proper
pliers, from the production of parts up to final
installation. The customer bears responsibility for the overall end pro-
assembly. The sum of all these apparently
duct.
minor details results in fan products with superior lifetimes and reliability.
9
Representatives
abrasion-resistant electrophoretic baked enamel. This particular ver-
AC centrifugal fans
subject to corrosion are permanently protected by an impact- and
Tailor-made to meet your special requirements
Practice-oriented: Fans – customised and intelligent
ebm-papst has always developed customerspecific intelligent fans which meet the exact
requirements of the application. We provide
a wide range of standard fan types, in many
sizes and designs; with intelligent motor features, monitoring and control functions as well
as special designs for use under extreme conditions. They are all based on the standard
type fans which you will find in this catalogue.
Special fan types for your application can be
produced in economical batch sizes. Our
expert engineers will assist you in selecting
the right configuration.
Innovation at its best:
Vario-Pro® with “intelligence inside”. Its programmed intelligence thanks to customer-specifically configured software modules makes
the cooling of electronics even more economical and flexible. For example, temperaturedependent speed profiles are possible with a
number of freely selectable interpolation
points. External speed settings and a variety of
combinable alarm and tachometer functions
can also be programmed. The digital motor
management achieves high control accuracy.
10
Information
DC axial fans
ebm-papst provides, on request, many fan series in versions which
thanks to sensor signal
conform to the requirements of Protection Class IP 54: Their stator and
Do you wish to be informed about the current
all electrical components are fully encapsulated. Stainless steel ball
fan speed at all times? ebm-papst has fans
bearings can be used for operation in particularly aggressive media
with an integrated “electronic tachometer”
and use under extreme environmental conditions, thus providing addi-
which registers the actual value of the fan
tional reliability.
speed. Via an integrated sensor, the fan gen-
DC centrifugal fans
“Electronic tachometer”
DC fans - specials
Higher protection class for every type of application
directly utilised. Depending on the number of
Regardless of your cooling and ventilation tasks, we develop the right
poles of the motor, 2, 3 or 6 pulses per revo-
solution and what is more, the most economical one. Based on the fans
lution are generated.
ACmaxx / i-maxx
erates speed-dependent signals which can be
Virtually everything is possible
listed in this catalogue, well over 4000 different versions are available.
Temperature-controlled fans
If your application requires monitored fan
Fans with temperature-controlled speed have particularly quiet cooling
operation, in addition to speed monitoring,
characteristics. Thanks to integrated IC technology, they adapt their
ebm-papst also provides a multitude of
speed to the current cooling requirements, which results in a drastic
varying alarm signals. Depending on the type
reduction of noise in most operating modes. A temperature sensor pro-
of fan in question, the signal is either static,
vides the fan with thermal information: either externally via a single
already evaluated or interface-compatible.
lead or integrated into the hub of the fan.
The alarm signal output provides reliable
AC axial fans
Alarm signal for more safety
longterm monitoring and a status signal if
critical operating conditions evolve.
provides an alternative to the NTC-controlled types of fans. They are
S-Force
especially suitable for systems and units which already have standard
The new measure of things!
interfaces for varying speed via internal switching and control circuits.
When you need to provide extremely fast,
The main applications are units which demand load-dependent individ-
powerful and efficient cooling for electronic
ual speed profiles or systems with stand-by minimum cooling require-
components of all kinds, the generation of
ments and varied speed increase at varying power peaks.
S-Force high-performance fans finishes first:
AC centrifugal fans
With a wide range of DC fans with separate control input, ebm-papst
Accessories
in air performance, pressure build-up and
technology. Extremely efficient drives and
optimised aerodynamics form the core technology of the S-Force fans, which we offer in
both an axial and brand-new centrifugal
model.
11
Representatives
Speed setting via interfaces
Types of fans and their function
Axial fans:
High air flow with medium to relatively high pressure build-up
The air flow in axial fans, whose impeller is similar to that of a propeller, is conducted to a great
extent parallel to the axis of rotation, in other words in the axial direction. Axial fans with free air
delivery at zero static pressure have the lowest power input that rises with increasing back
pressure. Axial fans for cooling of electronic equipment are mostly equipped with external housing and an electric motor integrated into the fan hub. This compact design allows space-saving
accommodation of all devices; the flange is equipped with mounting holes.
Diagonal fans:
High flow rate at relatively high pressure build-up
At first glance diagonal fans only differ slightly from axial fans. Intake is axial, whereas exhaust
is diagonal. Due to the conical shape of the wheel and housing, the air is pressurised more. In
direct comparison with axial fans of the same size and comparable performance, these fans are
distinguished by the lower operating noise at high pressures.
Centrifugal fans:
High pressure build-up at limited flow rate
Many of the cooling problems that occur can be optimally solved by axial and/or diagonal fans.
If, for example, the required cooling air has to be conducted at an angle of 90° or if even high
pressure is necessary, centrifugal fans are more effective. For your application, ebm-papst
offers not only complete centrifugal fans but also motor/impeller combinations without external
housing.
Tangential fans:
High flow rate at low pressure
Tangential fans are used above all-, for large-surface air flow in devices. The air flows through
the roller-shaped impellers twice in the radial direction: in the intake area from the outside to
the inside and in the outflow area from the inside to the outside. Whirls form in the roller due to
the vanes which guarantee a steady flow of air through the impeller.
12
Information
2. Permissible temperature rise
DC fans - specials
Pa
15
[in H2O]
20
represents a suitable value for this purpose.
0,12
25
ved. The electrical power consumption of the unit to be cooled, often
0,10
it is important to determine the dissipated energy that must be remo-
Optimum Operating
Range
0,08
30
10
0,04
35
devices is converted into heat. In selecting the correct fan, therefore,
5
0,02
A large amount of the energy consumed by electrical and electronic
0,06
1. Dissipated energy
DC centrifugal fans
DC axial fans
Selecting the correct fan
The air flow which the selected fan is required to generate, is deter0,4
0,8
1
1,2
2
1,6
CFM
2,0
3
4
ACmaxx / i-maxx
0
mined by the dissipated energy and the permissible rise (ΔT) of the
m³/h
cooling air flow (from entry to exit of the device to be cooled). The
max. allowable ΔT depends greatly on the temperature sensitivity of
• Read down from this point to obtain the
ge air flow leaving the device to be cooled may only be 5°C warmer
required value for the cooling air flow.
than the ambient temperature (a large volume of air is required for this
The diagram is based on
purpose). A lower air flow rate is sufficient if a higher temperature dif-
the following formula:
ference (e.g. ΔT = 20K), can be tolerated.
AC axial fans
the individual device components. ΔT = 5K means e.g. that the avera-
Pv [w]
V· [m3/h] ≈ 3 ·
ΔT [K]
3. Required cooling air flow
• In the below diagram a horizontal line is drawn from the dissipated
enery to intersect with the selected ΔT line.
4. Optimum operating range
The required fan, however, must also be able
to deliver a suitable static pressure increase
AC centrifugal fans
Δpf, in order to force the cooling air through
the device. A fan must therefore be selected
that provides the required air flow performance
within its optimum operating range (see also
Example : P v = 300 W att
Δ t = 10 K
20
10
5. Fan selection
filled by more than one fan, the noise level,
space requirements, economy and ambient
Waste Heat Pv
30
Δt5K
If the requirements of an application are ful-
200
150
100
50
data).
conditions will assist in making the final choice.
90 m³/h
m³/h
Air Flow
5
10
20
30 40 50
100
200 300
500
13
Representatives
500
300
Δ t 20 K
Δ t 15 K
Δ t 10 K
Accessories
Watt
the air performance curves under technical
5000
1000
Fan installation
Intake or exhaust side installation
Baffle
Under ideal conditions, the operating point is
represented as the intersection between the
fan and loss curves, regardless of whether the
fan is positioned at the air intake or exhaust
Multidirectional intake,
laminar currents
side of the device. In addition to ensuring the
required flow rate, several additional aspects
must be considered for determining an appropriate fan concept.
The intake air currents of a fan are mainly
laminar, comprising nearly the entire suction
area. By contrast, the exhaust air of a fan is
Unidirectional exhaust,
turbulent
generally turbulent, while it flows on a preferred direction, e.g. axial for an axial fan. The
turbulences of the exhaust intensify the heat
transfer from components within the air currents, so that mounting the fan at the air
intake side of the device is recommended for
cooling and heating. Mounting the fan at the
Information on installation
device intake is also advantageous because
When a fan is operated for the first time in an application, the user may
the fan will not be subjected to the dissipated
have noticed that the flow rate in the device was lower than expected.
heat of the device. Therefore, it operates at
What is the reason for this?
low ambient temperatures and has a higher
• The values stated in this catalogue were determined under optimum,
life expectancy.
constant and comparable measurement conditions.
• Ideal mounting conditions under which free air intake and exhaust
are present are seldom feasible in practice. Quite frequently the fans
must be mounted in close proximity to other components or cabinet
Accident prevention
panels. As a consequence, the intake and exhaust currents may be
The turning rotor and the high speeds that
restricted, causing the air flow to diminish and the noise level to
are sometimes involved mean that our fan
increase. Fans are particularly sensitive to obstructions which are
products carry an inherent risk of injury.
positioned directly in front of the output cross section as they often
They may only be operated after correct
cause an increase in tonal noise.
installation and with suitable protective
facilities (e.g. with a guard grille). More
Our advice: The distance between the fan and adjacent components
information can be found in the internet at:
should be at least equal to the installation depth of the fan.
www.ebmpapst.com/safety
14
Information
Fans in an endurance test
cabinet at ebm-papst St.
Georgen. 1500 fans are
operated in temperature
cabinets until they fail.
each product. The first column usually states the service life L10 at
40°C. the second column usually states the service life L10 at Tmax.
Exceptions are marked in the column headings. The third column states
before a representative number of failures have been registered, and even today, some fans are
still in the process of endurance testing, even though they began tests in the 1980s. These fans
Bel(A)
These tests have given us years of experience in the way various design parameters and temperatures can affect the service life of a product. Data for service life at various temperatures
Specials
Curve
L10Δ (40 °C) s. S. 15
Hours
67 500 / 35 000
140 000
1
P. 110
5,3
4,2
3 300
-20...+70
65 000 / 32 500
130 000
2
Example of the service life figures on the page of the
catalogue.
%
X
X = failure
b>1
X
10
X
X
b»1
duct specifications and of commonalities in the design of the product.
(h)
L10
Failure rate l(t)
Service life t
t1
0
Type of
error
Premature
failure
tures. The service life at temperatures below the test temperatures is calculated using fixed fac-
t2
Service life t
the calculation methods conventionally applied in the compact fan market. Again here, the foundations for the service life values are our service life endurance tests at high ambient tempera-
Life expectancy
Hours
-20...+70
for new products can be stated with a very high degree of precision on the basis of tests, pro-
New: Life expectancy L10Δ (40°C)
The new third service life column states the expected service life L10Δ. This value is based on
Service life L10 (Tmax)
ebm-papst standard
°C
2 700
Probability of failure
re tested is determined on the basis of the Weibull distribution.
Service life L10 (40 °C)
ebm-papst standard
RPM
2,5
/
are proof of the legendary reliability of fans from the Black Forest.
Test results are presented in a diagram and the service life of the product L10 at the temperatu-
Temperature range
Watts
5,0
ACmaxx / i-maxx
values, or when the operating noise becomes noticeable. Such tests can take several years
Random failure
b»1
b1
AC centrifugal fans
tors. This method produces much higher service life values, especially at room temperature (see
diagram on right).
DC axial fans
Our fans catalogue gives three different values for the service life of
DC centrifugal fans
Service life data from ebm-papst St. Georgen
DC fans - specials
Service life
Bathtub curve and Weibull distribution.
Summary:
2/10K
assumptions. The values determined here are extrapolations from our own service life tests and
from statistical variables. In the respective customer applications, different influences may occur
1,65/10K
L 10Δ= 2/15K
Accessories
all allow statements to be made about the theoretical calculated service life under certain
1,5/10K
+
which cannot be included in the calculations due to their complexity. The service life information
+
is explicitly not a guarantee of service life, but strictly a theoretical quality figure.
+
ebm-papst standard
20
30
+
+
40
50
60
70
Operating temperature (°C)
80
Example of the influence of factors from various manufacturers on the expected service life.
15
Representatives
experience gained by ebm-papst. The specified L10 (40°C), L10 (Tmax) and L10Δ (40°C) values
Expected service life
The life span calculations have been carried out to the best of our knowledge and are based on
Definitions
Subject to technical alterations.
Our products are not designed for use in the aerospace industry!
German and international patents, registered designs and utility models.
ebm-papst is a registered trademark of ebm-papst Mulfingen
GmbH & Co. KG.
PAPST, SINTEC, VARIOFAN and Vario-Pro are registered trademarks of ebm-papst St. Georgen GmbH & Co. KG.
Nominal voltage (Volts)
air density affect pressure generation but not
Ball bearings
The voltage at which the nominal values (the ta-
the flow rate. The pressure generated at other
Precision ball bearings for particularly high
bular values listed in this catalogue) were deter-
air densities may be estimated with the formula
ambient temperatures and high service life
mined. The fan operation for DC fans is not lim-
Δρ2 = Δρ1 (ρ2 / ρ1).
expectancy.
ited to the nominal voltage. Fan speed and fan
The nominal speed values, air flow and power
performance can vary according to the permis-
input listed in the table were measured in free
Power input (Watts)
sible voltage range that is specified on the
air operation with horizontal shaft at an ambient
Input performance of the fan motor when
nameplate of each fan.
temperature of 20 +5 °C, air density
ρ = 1.2 kg/m3 after a warm-up period of 5 min.
operating at nominal voltage. Depending on the
Frequency (Hz)
ebm-papst AC fans are made for operating frequencies of 50 Hz or 60 Hz. Their technical data
operating condition in the application, the power
input may be higher.
Optimum operating range
During operation, fans are required to produce
Temperature range (°C)
an air flow with a simultaneous increase of
The permissible ambient temperature range
Air flow (m3/h)
pressure. These operating conditions are
within which the fan can be expected to run
The air performance of the fan in free air opera-
described in the section “Optimum Operating
continuously.
tion, i.e. the fan blows into the free space with-
Range”. The optimum operating range is there-
out static pressure build-up.
fore always indicated in this catalogue in the
Service life [h]
shaded area. In this range the fans operate best
Fan curves
Service life L10 at 40°C and Tmax
with respect to efficiency and noise level. Within
The fan curves are determined in accordance
Standard figures for service life at ebm-papst.
this optimum operating range the noise level
with DIN 24 163 specifications on a dual-cham-
These two temperatures are based on intensive,
only fluctuates insignificantly.
in-house endurance tests and on the experience
alter accordingly.
ber test stand with intake-side measurement.
This measurement technique closely approximates the operating conditions experienced in
typical applications for fans and yields realistic
performance curves. The curves apply to an air
density of ρ = 1.2 kg/m3, corresponding to an
air pressure of 1013 mbar at 20 °C. Variations in
more than 60 years developing fans.
Noise [dB(A), Bel(A)]
1. Sound pressure level – dB(A)
Life expectancy L10Δ
Δ (40°C)
Figures oriented towards the calculation metho-
Noise ratings of the fan in free air operation, i.e.
ds employed by other fan manufacturers. Data
at maximum flow rate.
based on the internal expected service life at
2. Sound power level – Bel(A) / dB(A)
70°C, more optimistically extrapolated to 40°C.
Pa
The sound power level is determined in the
Fan Curve
optimum operating range.
0,12
25
0,10
20
0,08
15
0,06
10
0,04
Optimum Operating
Range
30
– Very precise, large sintered bearings
0,02
35
[in H2O]
Extent of the overall sound radiation of the fan.
– Low running noise
5
0
PAPST Sintec® sleeve bearings
A particularly efficient bearing system with
excellent qualities:
0,4
0,8
1
16
1,2
2
1,6
2,0
3
CFM
4
m³/h
– High service life expectancy
– Insensitive to shock and vibration
We expressly state that none of the information or data in this catalogue is to be construed as a guarantee or warranty of properties.
Unit conversion
Air flow
Pressure
1cfm = 1,7 m3/h
1l/s = 3,6 m3/h
1Pa = 1x10-5bar
1 inch H2O = 249 Pa
1l/min = 0,06 m3/h
1 mm H2O = 9,81 Pa
ACmaxx / i-maxx
DC fans - specials
DC centrifugal fans
23
AC axial fans
DC axial fans / DC diagonal fans
AC centrifugal fans
19
Accessories
DC axial fan overview
17
Representatives
DC axial fans
Information
DC axial fans
DC fans
Technical information
Range of fans
Voltage range
ebm-papst offers you the widest full product
Many of our DC fans can be operated on volta-
line of DC axial and diagonal fans: From 25 mm
ges that are up to 50% lower and 25% higher
to 280 mm in size. Every single type of fan can
than their nominal voltage (see Voltage range in
be optimally integrated in the respective device
the technical tables). This enables the air per-
concept. The highly economical brushless motor
formance to be adapted to the cooling require-
technology of these fans provides a unique
ments and allows the noise to be reduced, even
variety of intelligent innovations that can be
if the fan does not have a control input.
realised today at prices that would have been
unthinkable just a few years ago.
Closed-loop speed control and monitoring
Closed-loop speed control and function monito-
Electronic protection against
ring are becoming increasingly important in
reverse polarity
many applications. ebm-papst offers many fans
ebm-papst DC fans have electronically commu-
in the standard design with a control input and
tated drives with electronic protection against
open collector speed signal.
reverse polarity.The electronics are conveniently
located in the fan hub.
S-Force
Product life expectancy
The new S-Force fans with their extremely high
blower capacity of up to 950 m3/h and pressu-
A distinctive feature of DC fan technology is
re build-up of up to 1200 pascals are capable
the convincingly high product life expectancy.
of dealing with the extreme heat load. If nee-
Thanks to the excellent efficiency of the brush-
ded, these fans can produce up to 100% more
less drives, the thermal load of the bearings is
output under full load and they work with a
reduced, thus considerably increasing the life
much broader delivery bandwidth than current
expectancy of the fans.
models. This makes them ideal for equipment
and systems with a high density of compo-
Protection class
nents. Thanks to intelligent motor features, they
DC fans with sleeve and ball bearings are pow-
can be individually adapted for any application.
ered by Class E insulated motors. All ebm-papst
S-Force fans are available in 5 standard dimen-
fans conform to the requirements of protection
sions.
class IP 20. Fans conforming to IP 54 and special protection classes are also available.
18
m3/h
Information
Page
60
70 80 90 100
200
300
400
500 600 700 800 900 1000
2000
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
10
3000
20
30
40
50
60
70 80 90 100
200
300
400
500 600 700 800 900 1000
2000
DC centrifugal fans
50
DC fans - specials
40
ACmaxx / i-maxx
30
AC axial fans
Air flow
250
2,1...4,5
400 F
6...9
400
10...13,5
400 J
19...24
500 F
11...20
600 F
19...33
620
21...67
630
40...44
600 N
21...56
600 N VARIOFAN 16...41
600 J
70...84
700 F
28...44
8450
33...118
8400 N
33...79
8400 N VARIOFAN 20...58
8300
32...80
8200 J
132...222
3400 N
61...102
3400 N VARIOFAN 44...84
3300
56...107
3200 J
130...280
4400 F
94...170
4400 FN
200...225
4300
95...204
4300 VARIOFAN 61...170
4400
150...285
4100 N
160...237
4100 NHH..NH6 260...440
4100 NH7..NH8 500...570
DV 4100
275
5200 N
187...338
DV 5200
270...324
5100 N
122...250
5300
338
5300 TD
410...670
7100 N
360...420
7200 N
360
6100
350
6300
395...545
6300 TD
600...950
6300 TD
710...950
DV 6200
540
DV 6200 TD 100...700
6400
205...480
6400 TD
90...900
DV 6400
530
DV 6400 TD 100...680
2200 FTD
790...1220
W1G 200
1090
K1G 200
1020...1245
K3G 200
1215...1640
W1G 250
1920
20
AC centrifugal fans
10
Accessories
25 x 8
40 x 10
40 x 20
40 x 25
50 x 15
60 x 15
60 x 25
60 x 25
60 x 25
60 x 25
60 x 32
70 x 15
80 x 25
80 x 25
80 x 25
80 x 32
80 x 38
92 x 25
92 x 25
92 x 32
92 x 38
119 x 25
119 x 25
119 x 32
119 x 32
119 x 38
119 x 38
119 x 38
119 x 38
119 x 38
127 x 38
127 x 38
135 x 38
140 x 51
140 x 51
Ø 150 x 38
Ø 150 x 55
172x160x52
Ø 172 x 51
Ø 172 x 51
172x160x51
Ø 172 x 51
Ø 172 x 51
172x150x51
172x150x51
172x160x51
172x160x51
220x200x51
225 x 80
225 x 80
225 x 89
280 x 80
m3/h
3000
19
Representatives
mm
Series
Dimensions
Overview of air performance
DC axial fans
Axial fans for DC operation
Optional special versions
Information on pictograms
On the pages of the catalogue and on the following overview pages, the pictograms illustrated below provide information about technically possible special versions in the fan line presented.
Please note that these special versions are not possible for all voltages and speeds, and not in all combinations.
The special versions are designed for specific customers and projects and are not usually available off the shelf.
PWM control input
Speed signal
The fan uses a separate wire to output information
about its speed, and thus about the speed of the rotor.
NG
PWM
The speed of the fan can be changed via a pulse-widthmodulated signal. This signal is applied to a specially
For technical details, please refer to page 110.
provided wire. For technical details, please refer to
Go / No-go alarm
page 121.
The fan uses a separate wire to output a static signal
Analogue control input
when it is stationary, thus providing information about
whether or not the rotor is turning. For technical
A
The speed of the fan can be changed via a control voltage. This control voltage is applied to a specially provided
details, please refer to page 117.
wire. For technical details, please refer to page 121.
Alarm with limit speed
Multi-option control input
If the speed drops below a certain level defined in the
The fan has a control input that the user can trigger eit-
fan's electronics, the fan will emit a static signal, thus
her using a PWM signal, an analogue signal or a
providing information about whether or not the rotor is
resistor. For technical details, please refer to page 122.
turning. For technical details, please refer to page 114.
External temperature sensor
T
An NTC is connected to the fan via a separate wire and
the fan changes its speed depending on the temperatu-
HP
re at the NTC. For technical details, please refer to
page 120.
Internal temperature sensor
I
In this case, the NTC is integrated into the fan and the
Protection for the fan's electronics against moisture and
condensation. For technical details, please refer to
page 123.
Û
IP54
IP 54
Protection of motor and PCB board against splashed
water and humidity. For technical details, please refer to
fan changes its speed depending on the temperature at
page 123.
the NTC. For technical details, please refer to page
Protection against salt spray fog
120.
20
Protection against moisture
SP
Protection of fan against the damaging effects of salt
spray fog. For technical details, please refer to page 123.
Information
Axial fans for DC operation
Series
mm
P.
for all voltages and speeds, and not in all combinations.
250
25 x 25 x 8
yes
•
–
–
–
–
–
–
• – –
23
The special versions are designed for specific custo-
400 F
40 x 40 x 10
yes
•
• –
–
–
– – –
• – –
24
mers and projects. As a rule they are not available off
400
40 x 40 x 20
yes
•
• –
–
–
• – –
• – –
25
the shelf and are tied to minimum volumes.
400 J
40 x 40 x 25
yes
•
• –
–
–
–
–
• • –
26
500 F
50 x 50 x 15
yes
•
• –
–
–
• – –
• – –
27
600 F
60 x 60 x 15
yes
•
• –
–
–
• – –
• – –
28
•
• •
• •
• • –
• • –
29
•
• •
• •
• • –
• • •
30
600 N
60 x 60 x 25
yes
/
•
• –
• •
–
–
–
• • –
31
600 N VARIOFAN
60 x 60 x 25
yes
/
•
• –
• •
–
–
–
• – –
32
NEW 600 J
60 x 60 x 32
yes
•
• –
–
–
–
–
–
• – –
33
700 F
70 x 70 x 15
yes
•
• –
–
–
–
–
–
• – –
34
NEW 8450
80 x 80 x 25
yes
•
• –
–
–
• – –
• – –
35
80 x 80 x 25
yes
•
• •
• •
• • –
• • –
36
8400 N VARIOFAN 80 x 80 x 25
yes
•
• –
• •
–
–
• – –
37
•
• •
• •
• • –
• • •
38
•
• •
• •
• • –
• – –
39
•
• •
• •
• • –
• • –
40
•
• –
• •
–
–
• – –
41
•
• •
• •
• • –
• • •
42
•
• •
• •
• • –
• • –
43
•
• •
• •
• • –
• – –
44
•
• •
• •
• • –
• – –
45
•
• •
• •
• • –
• • •
46
•
• •
• •
• • –
• – –
47
•
• •
• •
• • –
• – –
48
•
• •
• •
• • –
• • •
49
8300
80 x 80 x 32
yes
8200 J S-Force
80 x 80 x 38
yes
3400 N
92 x 92 x 25
yes
3400 N VARIOFAN 92 x 92 x 25
yes
3300
92 x 92 x 32
yes
3200 J
92 x 92 x 38
yes
4400 F
119 x 119 x 25
yes
4400 FN
119 x 119 x 25
yes
4300
119 x 119 x 32
yes
4300 VARIOFAN
119 x 119 x 32
yes
/
/
/
/
/
/
–
–
4400
119 x 119 x 38
yes
4100 N
119 x 119 x 38
yes
4100 NH..NH6
119 x 119 x 38
yes
•
• •
• •
• • –
• – –
50
/
4100 NH7..NH8
119 x 119 x 38
yes
•
• •
• •
• • –
• – –
51
DV 4100
119 x 119 x 38
yes
•
• •
• •
• • –
• • •
52
5200 N
127 x 127 x 38
yes
•
• •
• •
• • –
• • •
53
DV 5200
127 x 127 x 38
yes
•
• •
• •
• • –
• • •
54
5100 N
135 x 135 x 38
yes
•
• •
• •
• • –
• • •
55
140 x 140 x 51
yes
•
• •
• •
• • –
• • •
56
140 x 140 x 51
yes
•
• •
• •
• • •
• – –
57
NEW 5300 S-Force
5300 TDS-Force
7100 N
150 Ø x 38
yes
•
• •
• •
• • –
• • •
58
7200 N
150 Ø x 55
yes
•
• •
• •
• • –
• • •
59
NEW 6100 N
172 x 160 x 51
yes
•
• •
• •
• • –
• • •
60
NEW 6300 S-Force
172 Ø x 51
yes
•
• •
• •
• • –
• • •
61
NEW 6300 TDS-Force
172 Ø x 51
yes
•
• •
• •
• • •
• • •
62
NEW 6300 TDS-Force
172 x 160 x 51
yes
•
• •
• •
• • •
• • •
63
DV 6200
172 Ø x 51
yes
•
• •
• •
• • –
• • •
64
DV 6200 TD
172 Ø x 51
yes
•
• •
• •
• • –
• • •
65
6400
172 x 150 x 51
yes
•
• •
• •
• • –
• • •
66
6400 TD
172 x 150 x 51
yes
•
• •
• •
• • –
• • •
67
DV 6400
172 x 160 x 51
yes
•
• •
• •
• • –
• • •
68
DV 6400 TD
172 x 160 x 51
yes
•
• •
• •
• • –
• • •
69
200 Ø x 51
yes
•
• •
• •
• • •
• • •
70
NEW 2200 FTD
W1G 200
225 x 225 x 80
UL/CSA
•
• •
• –
• • •
• – •
71
NEW K1G 200
225 x 225 x 80
yes
•
• •
• –
• • •
• – •
72
NEW K3G 200
225 x 225 x 89
yes
•
• •
• –
• • •
• – •
73
W1G 250
280 x 280 x 80
UL/CSA
•
• •
• –
• • •
• – •
74
DC fans - specials
yes
yes
ACmaxx / i-maxx
60 x 60 x 25
60 x 60 x 25
about the feasibility of your special variant.
AC axial fans
620
NEW 630
Please consult your customer support representative
AC centrifugal fans
–
Accessories
–
* approvals
applied for
– not yet available
• available
Sleeve bearings
Ball bearings
21
Representatives
OPTIONAL
DC centrifugal fans
Please note that these special versions are not possible
Axial fans
8400 N
DC axial fans
No-g
Alarm o alarm
with
limit
spee
Exte
rnal
d
t
e
m
pera
Inter
ture
nal t
emp
sens
eratu
PWM
o
re se r
con
nsor
Analo trol inpu
t
gue
cont
rol in
Mult
put
i-op
tion
cont
rol in
Hum
put
idity
prot
IP >
ectio
= IP
n
54
Salt
spra
y fog
prot
ectio
Page
n
Go /
Sens
or
eve
CSA
c sle
Sinte
VDE
, UL,
Dim
ensio
ns
bear
ings
/ball
bear
ings
Overview of technically feasible designs
Connection instructions for S-Force fans
Special features of S-Force fans
The S-Force series is the most powerful product series on the market. S-Force stands for the highest innovation in motor technology, fluid mechanics and electronics. The one-of-a-kind power density of the products requires special attention to the application at the customer's facility.
Service life
+Vs
Due to the high currents in the fans, the load on the electrolyte capacitors is greater, which reduces the service life of the capacitor. As a larger or additional capacitor cannot be housed in the fan, the capacitor
Power
Supply
Microcontroller
must be housed in the supply line.
GND
If the power pack of the application has a corresponding capacitor, in
some cases it may be possible to omit the external capacitor.
Fan
M
Recommended measure: Additional external capacitor (thus must be installed as close to the fan as
possible < 30 cm).
Capacitor
Recommended capacitors
required
We recommend using the following capacitors from Rubycon:
24 VDC:
50 ZL 680 μF; 12,5 mm x 30 mm or
S-Force axial
50 ZLH 680 μF 12,5 mm x 30 mm
8200 / 3200 JH3-JH4
no
4100 NH3 / NH4 / NH5 / NH6
no
4100 NH7 / NH8
yes
48 VDC:
5300 / 5300 TD
no
100 YXG 470 μF; 16 mm x 35,5 mm or
6300 / 6300 TD
no
100 ZLH 470 μF 16 mm x 31,5 mm
2200 FTD
no
Other capacitors with equal or greater capacitance and equal or lower
S-Force centrifugal
serial resistance can also be used.
RET 97 TD
yes
ebm-papst St. Georgen offers the following capacitors ex stock:
RER 120 TD
yes
24 VDC: 1000 μF / 50 V, 16 mm x 25 mm
RER 133 TD
no
Art. No.: 992 0345 000 (LZ 354)
RER 160 NTDHH
yes
REF 175 TD
no
48 VDC: 680 μF / 100 V, 18 mm x 40 mm
RER 175 TD
no
Art. No. : 992 0355 000 (LZ 355)
RER 190 TD / RG 190 TD
no
RER 220 TD / RG 220
no
RER 225 TDM / RG 225 TDM
no
RER 225 TD / RG 225 TD
yes
22
Information
DC axial fans
4,5 m3/h
max.
Series 250
25 x 25 x 8 mm
DC axial fans
Highlights:
– Compact fan with low power consumption.
DC centrifugal fans
2
/2
-10...+55
35 000 / 12 000*
30 000
3
/2
/2
2,1
1,2
5
4,5...5,5
5
90 % PWM. Standstill at 0 % PWM,
standstill if control cable is interrupted.
The specific service life is valid when an external capacitor is wired between the plus and minus strands.
Please note the wiring suggestion.
AC centrifugal fans
Accessories
243,2
1,5
0,5
7,0 + 0,3
0
100
200
200
400
300
400
600
500
800
600
1000
700
[CFM]
1200
[m3/h]
NG
T
I
PWM
A
HP
112 + 1,0
Û
IP54
91
Representatives
100
0,25
200
0,75
1
300
1
1,25
400
350 +10
+ 0,5
[Pa]
[in H2O]
2,25
1,75
500
2
2
600
,5
+0
530
6 +1
AC axial fans
For suitable guard
grilles, see page 176.
DC centrifugal fans
220 m3/h
max.
Series RET 97 TD
97 Ø x 41 mm
8,1
72
48
36...60
8,1
72
Hours
Hours
6 000
-20...+60
80 000 / 50 000
160 000
1
6 000
-20...+60
80 000 / 50 000
160 000
1
* Preliminary
R16
Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM,
maximum speed at sensor break.
To attain the specified service life, an external capacitor must be wired between the plus and minus strands.
Please note the wiring suggestion on page.
The air flow and noise level of fans without external
housing depends on the installation conditions. The stated
air flow and noise levels have been measured under the
following conditions:
Centrifugal fan mounted on a base plate 116 x 116 mm.
Cover plate 116 x 116 mm with an air inlet of Ø 80 mm,
concentric to the impeller.
Air flow
800
310 +10
[in H2O]
Pa
2 mm
6 +1
Air flow
200
0,8
300
24,4
100
40,5
0
25
50
92
50
75
100
100
150
NG
125
200
CFM
m³/h
T
I
PWM
A
HP
+1
M4 (4x)
400
1,6
500
7,95 + 1
97
ø 47,1
2,4
600
ø 58,3
1
700
Specials
16...36
°C
Curve
129
24
RPM
(40 °C) see P. 15
220
Watts
Life expectancy L10Δ
RET 97-25/18/2TDP
/
Service life L10 (Tmax)
ebm-papst Standard
NEW
Bel(A)
Service life L10 (40 °C)
ebm-papst Standard
129
VDC
Temperature range
220
VDC
Nominal speed
RET 97-25/14/2TDP*
Power input
NEW
Sintec sleeve bearings
Ball bearings
CFM
Sound power level
m3/h
Voltage range
Air flow
Type
Nominal data
Nominal voltage
Air flow
Highlights:
– 3-phase fan drive with high degree of running smoothness.
– Very high pressure build-up.
– Forward curved impeller.
– Available as standard with PWM control input and speed signal.
Additional inputs and outputs on request.
General characteristics:
– Impeller of galvanised steel plate.
– Fully integrated electronic commutation.
– Direction of rotation: CW seen on rotor.
– Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet.
– Connection via single strands AWG 22, TR 64. Bared and tin-plated.
– Mass: 430 g.
RPM
Information
°C
Hours
Hours
Specials
Watts
Curve
/
(40 °C) see P. 15
Bel(A)
Life expectancy L10Δ
Power input
VDC
Service life L10 (Tmax)
ebm-papst Standard
Sintec sleeve bearings
Ball bearings
VDC
Service life L10 (40 °C)
ebm-papst Standard
Sound power level
CFM
Temperature range
Voltage range
m3/h
Nominal speed
Nominal voltage
Type
Air flow
Nominal data
Air flow
Highlights:
– Pressure-optimised blower.
– Very flat and powerful centrifugal fan.
– Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made
solution to the specific requirements of your applications.
– Backward curved impeller.
General characteristics:
– Fibreglass-reinforced plastic scroll housing and impeller.
– Fully integrated electronic commutation.
– Protected against reverse polarity and locking.
– Direction of air flow radial, direction of rotation clockwise, seen on rotor.
– Connection via single strands AWG 22, TR 64. Bared and tin-plated.
– Mass: 160 g
P. 110
86
50,6
12
8...15
6,3
7,5
5 400
-20...+75
80 000 / 30 000
135 000
1
/2
REF 100-11/14
86
50,6
24
16...30
6,3
7,5
5 400
-20...+75
80 000 / 30 000
135 000
1
/2
86
50,6
48
36...60
6,3
7,5
5 400
-20...+75
80 000 / 30 000
135 000
1
/2
104
61,2
48
36...56
6,9
14,8
6 700
-20...+70
67 500 / 30 000
120 000
2
REF 100-11/18
REF 100-11/18 H
ACmaxx / i-maxx
REF 100-11/12
AC axial fans
R 3,5
The air flow and noise level of fans without external
housing depends on the installation conditions. The stated
air flow and noise levels have been measured under the
following conditions:
Centrifugal fan mounted on a base plate 127 x 127 mm.
Cover plate 127 x 127 mm with an air inlet of Ø 70 mm,
concentric to the impeller.
Air flow
DC axial fans
104 Ø x 25 mm
DC centrifugal fans
Series REF 100
DC fans - specials
DC centrifugal fans
104 m3/h
max.
2 mm
AC centrifugal fans
Air flow
24,9 +- 0,3
5,7 +- 0,3
2
Accessories
400
1,6
500
0,8
100
10
20
20
30
40
40
60
50
80
CFM
100
O 56
O 72
0
M 4 (3x)
tief
66 deep
200
0,4
1,2
1
300
m³/h
NG
T
I
PWM
A
HP
Û
IP54
93
Representatives
Pa
[in H2O]
22,4 +- 0,4
DC centrifugal fans
190 m3/h
max.
Series RER 101
101 Ø x 52 mm
Highlights:
– Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made
solution to the specific requirements of your applications.
– Backward curved impeller.
7,2
111,8
48
43...52
7,2
RER 101-36/18NHH
190
°C
Hours
Hours
5 900
-20...+70
60 000 / 30 000
120 000
1
20,0
5 900
-20...+70
60 000 / 30 000
120 000
1
19,0
5 900
-20...+70
60 000 / 30 000
120 000
1
R7
The air flow and noise level of fans without external
housing depends on the installation conditions. The stated
air flow and noise levels have been measured under the
following conditions:
Centrifugal fan mounted on a base plate 148 x 148 mm.
Cover plate 148 x 148 mm with an air inlet of Ø 66 mm,
concentric to the impeller.
Air flow
Pa
[in H2O]
1 mm
Air flow
36,7
1
O 60 +- 0,2
1,5
400
1,0
300
M 4 (3x)
0,5
100
0
20
25
94
40
50
75
60
100
80
125
100
150
NG
tief
10 deep
200
6,0 +- 0,2
7,0 +- 0,45
8,0 +- 0,55
50,25 +- 0,95
51,7 +- 0,9
CFM
m³/h
T
I
PWM
A
HP
Specials
18..27,2
190
Curve
24
RER 101-36/14NHH
(40 °C) see P. 15
111,8
111,8
Life expectancy L10Δ
20,5
190
Service life L10 (Tmax)
ebm-papst Standard
7,2
RER 101-36/12NHH
RPM
Service life L10 (40 °C)
ebm-papst Standard
9..13,6
CFM
Temperature range
12
m3/h
Nominal speed
Power input
Sound power level
Bel(A)
Air flow
VDC
Air flow
Voltage range
Watts
Nominal voltage
/
VDC
Type
Nominal data
Sintec sleeve bearings
Ball bearings
General characteristics:
– Fibreglass-reinforced plastic scroll housing and impeller.
– Fully integrated electronic commutation.
– Protected against reverse polarity and locking.
– Direction of air flow radial, direction of rotation clockwise, seen on rotor.
– Connection via single strands AWG 22, TR 64. Bared and tin-plated.
– Mass: 305 g.
P. 116
/19
Information
DC centrifugal fans
Series RER 120 TD
120 Ø x 54 mm
°C
Hours
DC axial fans
DC centrifugal fans
Hours
NEW
RER 120-26/14/2 TDMP*
320
188,2
24
16...32
tbd
51
5 200
-20...+60
60 000 / 37 500
120 000
1
NEW
RER 120-26/14/2 TDP
377
221,9
24
16...32
8,2
78
6 100
-20...+60
55 000 / 35 000
110 000
2
NEW
RER 120-26/18/2 TDMP*
320
188,2
48
36...60
tbd
51
5 200
-20...+60
57 500 / 35 000
115 000
1
NEW
RER 120-26/18/2 TDP
*Preliminary
390
229,5
48
36...60
8,3
92
6 300
-20...+60
50 000 / 30 000
100 000
3
ACmaxx / i-maxx
RPM
Specials
Watts
Curve
/
(40 °C) see P. 15
Bel(A)
Life expectancy L10Δ
Power input
VDC
Service life L10 (Tmax)
ebm-papst Standard
Sintec sleeve bearings
Ball bearings
VDC
Service life L10 (40 °C)
ebm-papst Standard
Sound power level
CFM
Temperature range
Voltage range
m3/h
Nominal speed
Nominal voltage
Type
Air flow
Nominal data
Air flow
Highlights:
– 3-phase fan drive with high degree of running smoothness.
– Very high pressure build-up.
– Backward curved impeller.
– Available as standard with PWM control input and speed signal.
Additional inputs and outputs on request.
General characteristics:
– Impeller of fibreglass-reinforced plastic.
– Fully integrated electronic commutation.
– Direction of rotation: CW seen on rotor.
– Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet.
– Connection via single strands AWG 22, TR 64. Bared and tin-plated.
– Mass: 430 g.
The air flow and noise level of fans without external
housing depends on the installation conditions. The stated
air flow and noise levels have been measured under the
following conditions:
Centrifugal fan mounted on a base plate 140 x 140 mm.
Cover plate 140 x 140 mm with an air inlet of Ø 96 mm,
concentric to the impeller.
AC axial fans
R16
Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM,
max. speed if control cable is interrupted.
The specific service life is valid when an external capacitor is wired between the plus and minus strands. Please note the
wiring suggestion.
Air flow
DC fans - specials
390 m3/h
max.
Pa
310 +10
[in H2O]
2 mm
6
+1
AC centrifugal fans
Air flow
3
M4 (4x)
max.
max.88tief
deep
1
0,8
300
13,5 + 1,5
100
26
0
50
100
100
150
200
200
300
54 +1
CFM
m³/h
NG
T
I
PWM
A
HP
95
Representatives
200
Accessories
1,6
400
ø 58,3
ø47,1
2
500
ø120 +0,5
600
DC centrifugal fans
166 m3/h
max.
Series RER 125 N
138 Ø x 35 mm
Highlights:
– Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made
solution to the specific requirements of your applications.
– Backward curved impeller.
24
12...28
5,7
97,7
24
12...28
7,0
64,7
48
36...56
5,7
5,0
110
RER 125-19/14 NH
166
RER 125-19/18 N
110
°C
Hours
Hours
2 650
-30...+75
62 500 / 27 500
125 000
1
4,5
2 650
-30...+75
62 500 / 27 500
125 000
1
13,0
4 000
-20...+70
55 000 / 27 500
110 000
2
2 650
-30...+75
62 500 / 27 500
125 000
1
4,5
P. 112
/12
R5
The air flow and noise level of fans without external
housing depends on the installation conditions. The stated
air flow and noise levels have been measured under the
following conditions:
Centrifugal fan mounted on a base plate 220 x 220 mm.
Cover plate 220 x 220 mm with an air inlet of Ø 86 mm,
concentric to the impeller.
Air flow
M4 (2x)
tief
55 deep
ø125
150
2
35 + 0,5
30,7+ 0,3
19
ø56
ø47
0,8
Pa
200
0,6
[in H2O]
2 mm
Air flow
4
4
20
25
96
40
50
60
75
100
6 +1
0
400 +10
0,4
50
0,2
1
100
80
CFM
125
m³/h
NG
T
I
PWM
A
HP
Specials
64,7
RER 125-19/14 N
Curve
5,7
64,7
(40 °C) see P. 15
7...15
110
Life expectancy L10Δ
12
RER 125-19/12 N
RPM
Service life L10 (Tmax)
ebm-papst Standard
Power input
Watts
CFM
Service life L10 (40 °C)
ebm-papst Standard
Sintec sleeve bearings
Ball bearings
/
m3/h
Temperature range
Sound power level
Bel(A)
Type
Nominal data
Nominal speed
Voltage range
VDC
Air flow
VDC
Air flow
Nominal voltage
General characteristics:
– Fibreglass-reinforced plastic scroll housing and impeller.
– Fully integrated electronic commutation.
– Protected against reverse polarity and locking.
– Direction of air flow radial, direction of rotation clockwise, seen on rotor.
– Connection via single strands AWG 22, TR 64. Bared and tin-plated.
– Mass: 320 g.
Information
DC centrifugal fans
Series RER 133 TD
133 Ø x 91 mm
DC axial fans
DC centrifugal fans
°C
Hours
Hours
NEW
RER 133-41/14/2 TDMP
460
270,6
24
16...30
tbd
53
5 000
-20...+65
72 500 / 40 000
145 000
1
NEW
RER 133-41/14/2 TDP*
565
332,4
24
16...36
tbd
90
6 000
-20...+65
70 000 / 37 500
140 000
2
NEW
RER 133-41/18/2 TDMP*
460
270,6
48
36...57
tbd
50
5 000
-20...+65
72 500 / 40 000
145 000
1
NEW
RER 133-41/18/2 TDP
565
332,4
48
36...72
8,2
87
6 000
-20...+65
70 000 / 37 500
140 000
2
ACmaxx / i-maxx
RPM
Specials
Watts
Curve
/
(40 °C) see P. 15
Bel(A)
Life expectancy L10Δ
Power input
VDC
Service life L10 (Tmax)
ebm-papst Standard
Sintec sleeve bearings
Ball bearings
VDC
Service life L10 (40 °C)
ebm-papst Standard
Sound power level
CFM
Temperature range
Voltage range
m3/h
Nominal speed
Nominal voltage
Type
Air flow
Nominal data
Air flow
Highlights:
– 3-phase fan drive with high degree of running smoothness.
– Very high pressure build-up.
– Backward curved impeller.
– Available as standard with PWM control input and speed signal.
Additional inputs and outputs on request.
General characteristics:
– Impeller of fibreglass-reinforced plastic.
– Fully integrated electronic commutation.
– Direction of rotation: CW seen on rotor.
– Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet.
– Connection via single strands AWG 22, TR 64. Bared and tin-plated.
– Mass: 890 g.
*Preliminary
The air flow and noise level of fans without external
housing depends on the installation conditions. The stated
air flow and noise levels have been measured under the
following conditions:
Centrifugal fan mounted on a base plate 140 x 140 mm.
Cover plate 140 x 140 mm with an air inlet of Ø 87 mm,
concentric to the impeller.
AC axial fans
R7
Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM,
max. speed if control cable is interrupted.
Air flow
DC fans - specials
565 m3/h
max.
41
50
100
100
200
150
200
300
250
400
300
CFM
500
m³/h
NG
T
I
PWM
A
AC centrifugal fans
Accessories
30,4 + 1,5
+1
HP
97
Representatives
91
0
ø133 +0,5
1,6
200
M4 (4x)
max.
max.8 8tief
deep
400
0,8
1
ø 72 +0,3
425 +10
ø58 + 0,1
Pa
6 +1
2
2,4
600
[in H2O]
2 mm
Air flow
DC centrifugal fans
255 m3/h
max.
Series RER 160 N
165 Ø x 51 mm
Highlights:
– Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made
solution to the specific requirements of your applications.
– Backward curved impeller.
RER 160-28/18 N
255
°C
Hours
Hours
3 000
-20...+70
75 000 / 35 000
140 000
1
19,0
3 000
-20...+70
75 000 / 35 000
140 000
1
19,0
3 000
-20...+70
75 000 / 35 000
140 000
1
R5
The air flow and noise level of fans without external
housing depends on the installation conditions. The stated
air flow and noise levels have been measured under the
following conditions:
Centrifugal fan mounted on a base plate 260 x 260 mm.
Cover plate 260 x 260 mm with an air inlet of Ø 100 mm,
concentric to the impeller.
Air flow
425 +10
ø58 + 0,1
ø 72 +0,3
ø160 +0,5
max.
max.8 8deep
tief
0,4
50
M4 (4x)
Pa
6 +1
0,8
100
0,2
150
1
0,6
200
[in H2O]
2 mm
Air flow
6,1+ 0,8
50,3 +0,7
0
20
40
50
98
60
100
80
100
150
NG
120
200
CFM
m³/h
T
I
PWM
A
HP
Û S
P
IP54
Specials
255
Curve
48
Air flow
150,1
Air flow
24
RER 160-28/14 N
(40 °C) see P. 15
6,4
150,1
150,1
Life expectancy L10Δ
28...60
7...14
255
Service life L10 (Tmax)
ebm-papst Standard
6,4
12
RER 160-28/12 N
Service life L10 (40 °C)
ebm-papst Standard
12...28
Bel(A)
CFM
Temperature range
19,0
VDC
m3/h
Nominal speed
Power input
6,4
Sound power level
RPM
Voltage range
Watts
Nominal voltage
/
VDC
Type
Nominal data
Sintec sleeve bearings
Ball bearings
General characteristics:
– Fibreglass-reinforced plastic scroll housing and impeller.
– Fully integrated electronic commutation.
– Protected against reverse polarity and locking.
– Direction of air flow radial, direction of rotation clockwise, seen on rotor.
– Connection via single strands AWG 22, TR 64. Bared and tin-plated.
– Mass: 590 g.
P. 112
/12
/12
Information
DC centrifugal fans
Series RER 160 NTD
165 Ø x 51 mm
DC axial fans
Highlights:
– Control inputs, alarm and speed signals available on request.
– 3-phase fan drive with high degree of running smoothness.
– High pressure build-up.
– Backward curved impeller.
98,3
48
36...60
8,5
142
48
38...57
Hours
4 200
-20...+60
55 000 / 27 500
110 000
2
6 000
-20...+65
40 000 / 22 500
80 000
3
-20...+70
55 000 / 27 500
110 000
—
2,0
800
7,4
43,0
4 200
DC centrifugal fans
51
Hours
P.
1
ACmaxx / i-maxx
18,3
RER 160-28/18 NTD...
7,4
°C
Specials
66
354
2
Model RER 160-28/18 NTD... is available in customer-specific, custom-developed variant only.
The data specified here are technically feasible benchmark values. The fans can be specially adapted to your application with signal
outputs and control inputs.
*The specific service life is valid when an external capacitor is wired between the plus and minus strands.
Please note the wiring suggestion.
AC axial fans
R5
The air flow and noise level of fans without external
housing depends on the installation conditions. The stated air flow and noise levels have been measured under
the following conditions:
Centrifugal fan mounted on a base plate 260 x 260 mm.
Cover plate 260 x 260 mm with an air inlet of Ø 100
mm, concentric to the impeller.
Air flow
425 +10
1,6
200
AC centrifugal fans
6 +1
Pa
400
0,8
Pa
[in H2O]
3,2
800
600
3
2,4
2 mm
1000
4,0 [in H2O]
Air flow
2
100
1,6
100
150
200
200
300
250
400
CFM
m³/h
max.
max.88deep
tief
6,1+ 0,8
1
n min
0
n max
50
50
50,3 +0,7
100
100
150
200
150
CFM
250
m³/h
NG
T
I
PWM
A
HP
99
Representatives
100
M4 (4x)
1,2
200
0,8
300
50
Accessories
0
400
ø58 + 0,1
ø 72 +0,3
ø160 +0,5
500
0,4
min.
max.
16...28
Curve
297,5
24
RPM
(40 °C) see P. 15
505
Watts
Life expectancy L10Δ
RER 160-28/18N/2TDHHP*
/
Service life L10 (Tmax)
ebm-papst Standard
NEW
Bel(A)
Service life L10 (40 °C)
ebm-papst Standard
217
VDC
Temperature range
370
VDC
Nominal speed
RER 160-28/14N/2TDA
Power input
NEW
Sintec sleeve bearings
Ball bearings
CFM
Sound power level
m3/h
Voltage range
Air flow
Type
Nominal data
Nominal voltage
Air flow
General characteristics:
– Fibreglass-reinforced plastic scroll housing and impeller; Housing base of steel plate.
– Fully integrated electronic commutation.
– Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet.
– Connection via single strands AWG 22, TR 64. Bared and tin-plated.
– Mass: 590 g.
DC fans - specials
505 m3/h
max.
DC centrifugal fans
800 m3/h
max.
Series REF 175 TD
175 Ø x 55 mm
48
36 ... 72
8,3
121
4 400
Specials
470
Curve
800
RPM
(40 °C) see P. 15
REF 175-30/18/2TDP
Watts
°C
Hours
Hours
-20...+60
65 000 / 37 500
130 000
1
R10
Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM,
max. speed if control cable is interrupted.
The air flow and noise level of fans without external
housing depends on the installation conditions. The stated
air flow and noise levels have been measured under the
following conditions:
Centrifugal fan mounted on a base plate 180 x 180 mm.
Cover plate 180 x 180 mm with an air inlet of Ø 125,5 mm,
concentric to the impeller.
Air flow
Pa
425 +10
[in H2O]
2 mm
6 +1
Air flow
1
max.
tief
max.8 8deep
M4 (4x)
300
200
6,8 + 0,8
30
100
54,3 + 1
0
100
200
100
200
300
400
400
600
NG
500
800
CFM
m³/h
T
I
PWM
A
HP
ø175 + 1,0
400
1,6
500
ø72 + 0,3
ø58 + 0,1
600
0,8
NEW
/
Life expectancy L10Δ
Bel(A)
Service life L10 (Tmax)
ebm-papst Standard
VDC
Service life L10 (40 °C)
ebm-papst Standard
Sound power level
VDC
Temperature range
Voltage range
CFM
Nominal speed
Nominal voltage
m3/h
Power input
Air flow
Type
Nominal data
Sintec sleeve bearings
Ball bearings
Air flow
Highlights:
– 3-phase fan drive with high degree of running smoothness.
– Very high pressure build-up. Backward curved impeller.
– Available as standard with PWM control input and speed signal.
Additional inputs and outputs on request.
General characteristics:
– Impeller of galvanised steel plate.
– Fully integrated electronic commutation.
– Direction of rotation: CW seen on rotor.
– Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet.
– Connection via single strands AWG 20, TR 64, speed signal and control input AWG 22,
bared and tin-plated.
– Mass: 930 g.
Information
DC centrifugal fans
Series RER 175 TD
175 Ø x 69 mm
RPM
°C
Hours
Hours
DC axial fans
DC centrifugal fans
RER 175-42/14/2 TDMLP
600
353,0
24
16...30
7,3
45
3 400
-20...+65
72 500 / 45 000
145 000
1
NEW
RER 175-42/14/2 TDMP
865
508,8
24
16...36
8,2
110
4 800
-20...+65
70 000 / 40 000
140 000
2
NEW
RER 175-42/18/2 TDMLP
600
353,0
48
36...57
7,3
46
3 400
-20...+65
72 500 / 45 000
145 000
1
NEW
RER 175-42/18/2 TDMP*
865
508,8
48
36...72
8,2
110
4 800
-20...+65
70 000 / 40 000
140 000
2
NEW
RER 175-42/18/2 TDP
980
576,8
48
36...72
8,5
166
5 400
-20...+65
60 000 / 32 500
115 000
3
* preliminary data
Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM,
max. speed if control cable is interrupted.
The air flow and noise level of fans without external
housing depends on the installation conditions. The stated
air flow and noise levels have been measured under the
following conditions:
Centrifugal fan mounted on a base plate 180 x 180 mm.
Cover plate 180 x 180 mm with an air inlet of Ø 125,5 mm,
concentric to the impeller.
Air flow
AC axial fans
R10
NEW
ACmaxx / i-maxx
Watts
Specials
/
Curve
Power input
Bel(A)
(40 °C) see P. 15
Sintec sleeve bearings
Ball bearings
VDC
Life expectancy L10Δ
Sound power level
VDC
Service life L10 (Tmax)
ebm-papst Standard
Voltage range
CFM
Service life L10 (40 °C)
ebm-papst Standard
Nominal voltage
Type
Temperature range
Air flow
m3/h
Nominal data
Nominal speed
Air flow
Highlights:
– 3-phase fan drive with high degree of running smoothness.
– Very high pressure build-up. Backward curved impeller.
– Available as standard with PWM control input and speed signal.
Additional inputs and outputs on request.
General characteristics:
– Impeller of fibreglass-reinforced plastic.
– Fully integrated electronic commutation.
– Direction of rotation: CW seen on rotor.
– Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet.
– Connection via single strands AWG 18, 20 or AWG 22, TR 64, speed signal and
control input AWG 22, bared and tin-plated.
– Mass: 775 g.
DC fans - specials
980 m3/h
max.
6 +1
425 +10
3
max.
max.8 8deep
tief
M4 (4x)
200
0,8
1
6,8+ 0,8
42
0
100
200
200
400
300
400
600
500
800
69 ±1
CFM
m³/h
NG
T
I
PWM
A
HP
Û S
P
IP54
101
Representatives
2,4
400
1,6
2
600
Accessories
ø58 + 0,1
ø 72 +0,3
ø175 +0,5
3,2
2 mm
Pa
[in H2O]
800
AC centrifugal fans
Air flow
DC centrifugal fans
970 m3/h
max.
Series RER 190 TD
190 Ø x 69 mm
RPM
°C
Hours
Hours
NEW
RER 190-39/14/2TDMLO
650
382,4
24
16...30
7,6
58
3 000
-20...+60
55 000 / 35 000
110 000
1
NEW
RER 190-39/14/2TDMO
860
505,9
24
16...36
7,9
110
3 900
-20...+65
52 500 / 30 000
105 000
2
NEW
RER 190-39/18/2TDMLO
650
382,4
48
36...57
7,6
56
3 000
-20...+65
55 000 / 35 000
110 000
1
NEW
RER 190-39/18/2TDMO
860
505,9
48
36...72
7,9
105
3 900
-20...+65
52 500 / 30 000
105 000
2
NEW
RER 190-39/18/2TDO
970
570,6
48
36...72
8,3
148
4 400
-20...+65
40 000 / 22 500
80 000
3
Specials
Curve
Watts
(40 °C) see P. 15
/
Life expectancy L10Δ
Bel(A)
Service life L10 (Tmax)
ebm-papst Standard
VDC
Service life L10 (40 °C)
ebm-papst Standard
Sound power level
VDC
Temperature range
Voltage range
CFM
Nominal speed
Nominal voltage
Type
Power input
Air flow
m3/h
Nominal data
Sintec sleeve bearings
Ball bearings
Air flow
Highlights:
– 3-phase fan drive with high degree of running smoothness.
– Very high pressure build-up.
– Backward curved RadiCal impeller with maximum efficiency.
– Standard models available with multifunctional control input for analogue, PWM and speed signal.
General characteristics:
– Impeller of fibreglass-reinforced plastic.
– Fully integrated electronic commutation.
– Direction of rotation: CW seen on rotor.
– Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet.
– Connection via single strands AWG 18, 20 or AWG 22, TR 64, speed signal and control input AWG
22, bared and tin-plated.
– Mass: 870 g.
R10
Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM,
standstill if control cable is interrupted.
The air flow and noise level of fans without external
housing depends on the installation conditions. The stated
air flow and noise levels have been measured under the
following conditions:
Centrifugal fan mounted on a base plate 195 x 195 mm.
Cover plate 195 x 195 mm with an air inlet of Ø 125,5 mm,
concentric to the impeller.
Air flow
+10
3
425
[Pa]
900
3,5 [in H2O]
6 +1
2 mm
Air flow
58
max. 88 deep
tief
max.
1
300
200
39
0,5
100
6,5 +1
0
100
200
102
200
400
300
400
600
500
800
NG
600
1000
69
[CFM]
3
[m /h]
T
I
PWM
A
HP
Û S
P
IP54
+1
190
+ 0,1
1,5
1
M4 (4x)
400
2
500
1,5
600
72 +0,3
2
700
+ 0,3
3
800
Watts
NEW
RER 220-44/14/2TDMO
1090
641,2
24
16...36
7,7
NEW
RER 220-44/18/2TDMO
1090
641,2
48
36...72
NEW
RER 220-44/18/2TDO
1280
752,9
48
36...72
RPM
Information
Specials
/
Curve
Power input
Bel(A)
(40 °C) see P. 15
Sintec sleeve bearings
Ball bearings
VDC
Life expectancy L10Δ
Sound power level
VDC
Service life L10 (Tmax)
ebm-papst Standard
Voltage range
CFM
Service life L10 (40 °C)
ebm-papst Standard
Nominal voltage
m3/h
Temperature range
Air flow
Type
°C
Hours
Hours
82
3 000
-20...+55
75 000 / 52 500
150 000
1
7,7
80
3 000
-20...+55
75 000 / 52 500
150 000
1
8,0
140
3 500
-20...+55
55 000 / 40 000
110 000
2
ACmaxx / i-maxx
Nominal data
Nominal speed
Air flow
Highlights:
– 3-phase fan drive with high degree of running smoothness.
– Very high pressure build-up.
– Backward curved impeller.
– Standard models available with multifunctional control input for analogue, PWM and speed sign.
General characteristics:
– Impeller of fibreglass-reinforced plastic.
– Fully integrated electronic commutation.
– Direction of rotation: CW seen on rotor.
– Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet.
– Connection via single strands AWG 18, 20 or AWG 22, TR 64, speed signal and control input
AWG 22, bared and tin-plated.
– Mass: 940 g.
The air flow and noise level of fans without external
housing depends on the installation conditions. The stated
air flow and noise levels have been measured under the
following conditions:
Centrifugal fan mounted on a base plate 230 x 230 mm.
Cover plate 230 x 230 mm with an air inlet of Ø 146 mm,
concentric to the impeller.
AC axial fans
R10
Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM,
standstill if control cable is interrupted.
Air flow
AC centrifugal fans
6 +1
+ 10
2
425
2,25
600
Accessories
+ 0,5
ø 220,9
M4 (4x)
max.
max.88deep
tief
ø 72 + 0,3
1,5
44,0
0,5
100
7,2 + 1,5
0,25
200
0,75
1
300
1,25
400
ø 58
1,75
+ 0,1
2
1
0
100
200
200
400
300
400
600
500
800
600
1000
700
[CFM]
1200
3
71+ 1
[m /h]
NG
T
I
PWM
A
HP
Û
IP54
103
Representatives
[Pa]
[in H2O]
2 mm
Air flow
500
DC axial fans
221 Ø x 71 mm
DC centrifugal fans
Series RER 220 TD
DC fans - specials
DC centrifugal fans
1280 m3/h
max.
DC centrifugal fans
1600 m3/h
max.
Series RER 225 TD
225 Ø x 99 mm
RER 225-55/18/2TDMLO
1080
635,4
48
36...72
7,5
82
NEW
RER 225-55/18/2TDMO
1210
711,9
48
36...72
7,9
120
NEW
RER 225-63/18/2TDP-402 1600
941,3
48
36...72
8,1
165
Specials
NEW
RPM
Curve
Bel(A)
(40 °C) see P. 15
VDC
Life expectancy L10Δ
VDC
Service life L10 (Tmax)
ebm-papst Standard
CFM
Service life L10 (40 °C)
ebm-papst Standard
m3/h
Temperature range
Sound power level
Type
Nominal data
Nominal speed
Voltage range
Power input
Nominal voltage
Watts
Air flow
/
Air flow
Sintec sleeve bearings
Ball bearings
Highlights:
– 3-phase fan drive with high degree of running smoothness.
– Very high pressure build-up.
– TDM and TDML model with backward-curved RadiCal impeller with maximum efficiency.
– Standard models available with multifunctional control input for analogue, PWM and speed signal.
General characteristics:
– Impeller of fibreglass-reinforced plastic.
– Fully integrated electronic commutation.
– Direction of rotation: CW seen on rotor.
– Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet.
– Connection via single strands AWG 18, 20 or AWG 22, TR 64, speed signal and control input AWG
22, bared and tin-plated.
– Mass: 1030 g.
°C
Hours
Hours
2 500
-20...+55
70 000 / 50 000
140 000
1
2 800
-20...+55
55 000 / 40 000
110 000
2
3 300
-20...+55
52 500 / 37 500
105 000
3
6 +1
Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0% PWM,
Type O: standstill at sensor break. Type P: maximum speed at sensor break.
Air flow
425 +10
2
100
55
10,6 + 1,5
0
100
200
104
200
400
300
400
600
500
600
700
800
800 1000 1200 1400
NG
900
99
[CFM]
[m3/h]
T
I
PWM
A
HP
Û
IP54
+1
ø 225
+ 0,5
ø 72 +0,3
M4 (4x)
max. 8 tief
max.
deep
ø 58 + 0,1
1
0,25 0,5 0,75
200
0,5
6 +1
3
1
300
2,75 [in H2O]
2 mm
400
99 + 1
Type RER 225-55
2,25 2,5
[Pa]
500
8,6 + 0,8
62,0
2
600
1,25 1,5 1,75
700
max. ø225
max.8 8deep
tief
max.
ø58
M4 (4x)
Air flow
ø72 + 0,3
425 +10
The air flow and noise level of fans without external
housing depends on the installation conditions. The stated
air flow and noise levels have been measured under the
following conditions:
Centrifugal fan mounted on a base plate 230 x 230 mm.
Cover plate 230 x 230 mm with an air inlet of Ø 146 mm,
concentric to the impeller.
+ 0,1
R10
Type RER 225-63
Information
DC tangential fan
Series QG 030
201...413 x 50 x 48 mm
DC axial fans
Highlights:
– Tangential fans with high air flow.
– Large air outlet.
Hours
DC centrifugal fans
°C
Hours
75
44,1
12
8...14
49
5,7
/
6,2
-20...+60
30 000 / 10 000
32 500
1
QG 030-198/12
100
58,9
12
8...14
51
5,8
/
8,0
-20...+60
30 000 / 10 000
32 500
2
QG 030-303/12
140
82,4
12
8...14
51
5,8
/
8,7
-20...+60
30 000 / 10 000
32 500
3
QG 030-353/12
155
91,3
12
8...14
51
5,9
/
9,6
-20...+60
30 000 / 10 000
32 500
4
QG 030-148/14
75
44,1
24
16...28
49
5,7
/
6,2
-20...+60
30 000 / 10 000
32 500
1
QG 030-198/14
100
58,9
24
16...28
51
5,8
/
8,0
-20...+60
30 000 / 10 000
32 500
2
QG 030-303/14
140
82,4
24
16...28
51
5,8
/
8,7
-20...+60
30 000 / 10 000
32 500
3
QG 030-353/14
155
91,3
24
16...28
51
5,9
/
9,6
-20...+60
30 000 / 10 000
32 500
4
Tangential fans are only suitable for operation with high
rate and low back pressure.
L
L1
QG 030-148/ ..
Type
Dimension:
201 +1,5
148
QG 030-198/ ..
258 +1,5
198
QG 030-303/ ..
363
+1,5
303
QG 030-353/ ..
413
+1,5
353
AC axial fans
QG 030-148/12
ACmaxx / i-maxx
Watts
Specials
/
(40 °C) see P. 15
Bel(A)
Curve
Life expectancy L10Δ
db(A)
Service life L10 (Tmax)
ebm-papst Standard
VDC
Service life L10 (40 °C)
ebm-papst Standard
Sound pressure level
VDC
Temperature range
Voltage range
CFM
Power input
Nominal voltage
Type
Sleeve bearings
Ball bearings
Air flow
m3/h
Nominal data
Sound power level
Air flow
General characteristics:
– Motor with ball bearing system. Impeller mounting plate with sleeve bearings.
– Fan housing and impeller of aluminium. Plastic housing side parts.
– Fully integrated electronic commutation.
– Protected against reverse polarity and locking.
– Air exhaust out of the outlet.
– Connection via single strands. Bared and tin-plated.
– Mass: 235 / 290 / 380 / 415 g.
DC fans - specials
155 m3/h
max.
AC centrifugal fans
The service life values refer to horizontal
installation of the fan.
12
[in H2O]
6
50
10
15
20
30
40
2
45
60
80
3
60
100
75
120
4
CFM
16,5
21,5
10
34,4
5,4 ±0,7
L
Cut-out
square nut
M3 562-flat
DIN 562,
Cutout forfor
squarenut
M3 DIN
(6x)flat (6x)
m³/h
HP
105
Representatives
1
Ø35,1
Ø41 +0,3
3,2
Accessories
Ø9
0,05
20
0
L1
47,5
0,10
30
10
10
Ø2,3 (8x)
0,15
40
38,4
300 ±10
Pa
50
106
Information
Alarm signal
114
Vario-Pro / Speed setting / Control input
119
Protection against ambient influences
123
DC axial fans
110
107
Representatives
Accessories
AC centrifugal fans
AC axial fans
ACmaxx / i-maxx
DC fans - specials
Sensor signal
DC centrifugal fans
DC fans - specials
DC fans - specials
Technical information
Cooling capacity and efficiency
Greater power density, increasing miniaturisation and extreme electronic
component density are posing increased demands on the cooling capacity
and efficiency of fans. The intelligent and space-saving integration of the
fan in the device configuration is therefore of major importance:
• Tailor-made cooling adapted to the situation as and when required.
• Programmable cooling by defining speed profiles.
• Transparency of function thanks to complete, interactive monitoring in
all operating conditions.
ebm-papst provides intelligent cooling concepts which are optimally
adapted to requirements. For example:
1. Speed adaptation via NTC sensor
Standard fans in electronics cooling– tried and tested by the millions and
nevertheless a temporary solution, because standard fans have a distinct
disadvantage: With constant speed and a corresponding high noise factor,
they continuously provide the air flow required in extreme cases. This
extreme case only occurs-, if it occurs at all-, for a fraction of the service
life. What is needed is an intelligent fan that automatically adapts to the
current cooling requirements.
108
The ebm-papst answer: A complete range of DC
fans with temperature-controlled speed adaptation - in all standard dimensions.
Installation is simple. The control electronics
receive their thermal information for speed
adaptation steplessly and loss-free via a temperature sensor either externally via a single
lead, positioned as required, or internally directly in the fan hub in the air flow.
2. DC fans with separate control input
Open or closed-loop speed control is also possible with DC fans that have a separate control
input. A variation in speed can thus be implemented via a control voltage or a pulse-width
modulated signal. These possibilities are used
primarily in devices that have appropriate standard interfaces and thus require a load-dependent variation of the fans.
Information
DC axial fans
DC fans - specials
DC centrifugal fans
A
Technical information
DC fans - specials
ACmaxx / i-maxx
AC axial fans
5. Turbo drives
Fans with three-phase EC drives and microprocessor-controlled motor electronics. These
three-phase motors whose torque is virtually
non-reliant on the rotor position are used for
extremely high running smoothness. The speed
of these fans can be controlled over a very wide
range with PWM, analogue voltage or temperature. Optionally, the fans can be supplied with
reversible direction of rotation and active brake
operation.
The successful concept of Vario-Pro is: Tailor-made
software instead of fixed hardware, because programmed software modules for motor control and
application intelligence are responsible for the
work that analogue components were responsible
for in the past. This central control unit of the
Vario-Pro comprises a microcontroller and an
EEPROM, on which all characteristics are stored.
7. Protection against environmental
influences
Some applications place particular demands on the
fans' resistance to ambient influences, such as
dust, moisture, water and salt. ebm-papst offer
solutions for adapting fans to these ambient conditions.
AC centrifugal fans
4. Alarm signal
For applications which require monitored fan
operation with alarm signal, ebm-papst has
numerous alarm signal versions, either a static,
pre-processed or interface-compatible high or
low continuous signal depending on the type of
fan.
6. Vario-Pro fans
This high-end fan concept by ebmpapst with programmed intelligence and customer-specific integrated functions makes your electronics cooling
even more versatile and competitive. Vario-Pro
ensures a fresh economic breeze for all demanding
cooling tasks – e.g. where greater reliability, more
flexibility and intelligent function features such as
alarm function, speed control etc. are required.
Accessories
3. Sensor signal
DC fans with sensor signal.
The integrated „electronic tachometer“ continuously provides an actual speed signal for external evaluation. The user is informed at all times
of the current fan speed via an extremely simple signal evaluation on the customer side. The
sensor signal is via a separate lead.
109
Representatives
PWM
Speed signal /2
Speed-proportional rectangular pulse for external speed monitoring of fan motor.
2, 3 or 6 pulses per revolution.
Open collector signal output.
Extremely wide operating voltage range.
Easy adaptation to user interface.
Connection via separate lead.
The sensor signal also serves as a major comparison variable for setting and
maintaining the setpoint speed for interactive or controlled cooling with one or several
interconnected fans.
Condition: Isource
VDC
mA
VDC
mA VDC
≤ 0,4
≤2
30
0
≤ 30
2
2
23
400 F
≤ 0,4
1
30
0
≤ 30
≤2
2
24
400
≤ 0,4
1
30
0
≤ 30
≤2
2
25
400 J
≤ 0,4
2
30
0
≤ 30
≤4
2
26
Signal output voltage
500 F
≤ 0,4
1
30
0
≤ 30
≤2
2
27
Standard signal for all models (exceptions see below)
600 F
≤ 0,4
1
30
0
≤ 30
≤2
2
28
UB
UB
+UBS
output
Isink
US
(-) Power
All voltages measured to ground.
External load resistor Ra / US / UBS required.
mA
Page
620
≤ 0,4
2
30
0
≤ 30
≤4
2
29
630 U
≤ 0,4
2
30
0
≤ 30
≤4
2
30
600 N
≤ 0,4
2
28
0
≤ 28
≤4
2
31
600 J
≤ 0,4
2
30
0
≤ 30
≤4
2
33
700 F
≤ 0,4
2
30
0
≤ 30
≤4
2
34
8450
≤ 0,4
2
28
0
≤ 28
≤4
2
35
8400 N
≤ 0,4
2
28
0
≤ 28
≤4
2
36
8400 N VARIOFAN
≤ 0,4
2
30
0
≤ 30
≤4
2
37
8300
≤ 0,4
2
30
0
≤ 30
≤4
2
38
8200 J
≤ 0,4
2
30
0
≤ 30
≤4
2
39
3400 N
≤ 0,4
2
28
0
≤ 28
≤4
2
40
3400 N VARIOFAN
≤ 0,4
2
30
0
≤ 30
≤4
2
41
3300
≤ 0,4
2
30
0
≤ 30
≤4
2
42
3 Pulse / Rotation
3212 J / 3214 J
≤ 0,4
2
30
0
≤ 30
≤4
2
43
Signal frequenzy [F]= 3 x n/60 Hz
3218 J
≤ 0,4
2
60
0
≤ 60
≤4
2
43
4412 F / 4414 F
≤ 0,4
2
30
0
≤ 30
≤4
2
44
4418 F
≤ 0,4
2
60
0
≤ 60
≤4
2
44
4400 FN
≤ 0,4
2
30
0
≤ 30
≤4
2
45
4312 / 4314
≤ 0,4
2
30
0
≤ 30
≤4
2
46
4318
U S High
Us
s
U S Low
t1
t
t2
1 Rotation
2 Pulse / Rotation
Signal frequenzy [F]= 2 x n/60 Hz
only for 4100 NH7 and NH8
U S High
Us
U S Low
t1
t
t2
1 Rotation
All
TD NTD,
fans. Ex.:
6400
6200
6400
TD,TD
DV 6200 TD, DV 6400 TD, RER / RG 160 NTD
U S High
Us
U S Low
t1
t
t2
1 Rotation
6 Pulse / Rotation
Signal frequenzy [F]= 6 x n/60 Hz
Fa n Speed
n
nmin
110
Signal data
Fan description
Speed signal
US High
Type
250
(+) Power
Sensor operating
voltage UBS
Condition: Isink
Customer
Speed signal
US Low
Fan
Perm. sink current
Isink max.
Electrical connection
Pulses per revolution
–
–
–
–
–
–
–
nmax
t
≤ 0,4
2
60
0
≤ 60
≤4
2
46
4312 / 4314 VARIOFAN ≤ 0,4
2
30
0
≤ 30
≤4
2
47
4318 VARIOFAN
≤ 0,4
2
60
0
≤ 60
≤4
2
47
4400
≤ 0,4
2
30
0
≤ 30
≤4
2
48
4100 N
≤ 0,4
2
30
0
≤ 30
≤4
2
49
4100 NHH...NH6
≤ 0,4
2
≤ 60
0
≤ 60
≤ 10
2
50
4100 NH7...NH8
≤ 0,4
2
≤ 60
0
≤ 60
≤ 20
3
51
DV 4100
≤ 0,4
2
30
0
≤ 30
≤4
2
52
5200 N
≤ 0,4
2
30
0
≤ 30
≤4
2
53
Information
DC centrifugal fans
Perm. sink current
Isink max.
≤ 30
≤4
2
54
0
≤5
≤ 20
2
55
60
0
≤ 60
≤ 20
2
55
≤ 72
0
≤ 72
≤4
2
56
2
72
0
≤ 72
≤ 20
6
57
≤ 0,4
2
60
0
≤ 60
≤ 20
2
58
7114 N
≤ 0,4
2
30
0
≤ 30
≤ 20
2
58
7200 N
≤ 0,4
2
15
0
≤ 15
≤ 20
2
59
6300
≤ 0,4
2
≤ 72
0
≤ 72
≤ 20
2
61
6300 TD
≤ 0,4
2
72
0
≤ 72
≤ 20
6
62
DV 6200
≤ 0,4
2
30
0
≤ 60
≤ 20
2
64
6400
≤ 0,4
2
60
0
≤ 60
≤ 20
2
66
2200 FTD
≤ 0,4
2
72
0
≤ 72
≤ 20
6
70
RL 48
≤ 0,4
2
3
0
≤ 30
≤4
2
81
RL 65
≤ 0,4
2
30
0
≤ 30
≤4
2
82
RL 90 N
≤ 0,4
2
30
0
≤ 30
≤4
2
83
RLF 100
≤ 0,4
2
30
0
≤ 30
≤4
2
84
RG 90 N
≤ 0,4
2
30
0
≤ 30
≤4
2
85
RG 125 N
≤ 0,4
2
30
0
≤ 30
≤4
2
86
RG 160 N
≤ 0,4
2
30
0
≤ 30
≤ 20
2
87
RG 160 TD
≤ 0,4
2
60
0
≤ 60
≤ 20
6
88
RG 190 TD
≤ 0,4
2
72
0
≤ 72
≤ 20
6
89
RG 220 TD
≤ 0,4
2
72
0
≤ 72
≤ 20
6
90
RG 225 TD
≤ 0,4
2
72
0
≤ 72
≤ 20
6
91
RET 97 TD
≤ 0,4
2
72
0
≤ 72
≤ 20
6
92
REF 100
≤ 0,4
2
30
0
≤ 30
≤4
2
93
RER 120 TD
≤ 0,4
2
72
0
≤ 72
≤ 20
6
95
RER 133 TD
≤ 0,4
2
72
0
≤ 72
≤ 20
6
97
RER 160 TD
≤ 0,4
2
60
0
≤ 60
≤ 20
6
99
REF 175 TD
≤ 0,4
2
72
0
≤ 72
≤ 20
6
100
RER 175 TD
≤ 0,4
2
72
0
≤ 72
≤ 20
6
101
RER 190 TD
≤ 0,4
2
72
0
≤ 72
≤ 20
6
102
RER 220 TD
≤ 0,4
2
72
0
≤ 72
≤ 20
6
103
RER 225 TD
≤ 0,4
2
72
0
≤ 72
≤ 20
6
104
≤ 0,4
2
15
5114 N / 5118 N
≤ 0,4
2
5300
≤ 0,4
2
5300 TD
≤ 0,4
7112 N / 7118 N
DC fans - specials
5112 N
Page
ACmaxx / i-maxx
30
AC axial fans
2
AC centrifugal fans
mA
≤ 0,4
Accessories
VDC
Attention:
With these fan options, deviations in regard to temperature range, voltage
range and power consumption are possible compared with standard fan
data.
111
Representatives
Sensor operating
voltage UBS
mA
0
Type
DV 5200
Signal data
Fan description
Condition: Isource
mA VDC
Condition: Isink
VDC
Speed signal
US Low
Speed signal
US High
Pulses per revolution
DC axial fans
Available on request:
– Electrically isolated sensor and signal circuit.
– Varying voltage potentials for power and logic circuit.
Speed signal /12
–
–
–
–
–
–
Speed-proportional rectangular pulse for external speed monitoring of fan motor.
2, 3 or 6 pulses per revolution.
TTL-compatible.
Integrated pull-up resistor.
Connection via separate lead.
The sensor signal also serves as a major comparison variable for setting and maintaining.
the setpoint speed for interactive or controlled cooling with one or more interconnected
fans.
Electrical connection
mA
mA
Page
1
2,5–5,5
1
1
31
1
2,5–5,5
1
1
31
≤ 0,4
1
2,5–5,5
1
1
36
4412 F/12 GM
≤ 0,4
1
2,5–5,5
1
1
44
4418 F/12
≤ 0,4
1
2,5–5,5
1
1
44
4312 /12 M
≤ 0,4
1
2,5–5,5
1
1
46
4314 /12
≤ 0,4
1
2,5–5,5
1
1
46
4182 N/12 X
≤ 0,4
1
2,5–5,5
1
1
49
Signal data
Speed signal
US Low
Type
VDC
mA
614 N/12 GM
≤ 0,4
618 N/12 N
≤ 0,4
8412 N/12 H
UB
output
US
(-) Power
All voltages measured to ground.
Signal output voltage
Standard signal for all models (exceptions see below)
U S High
Us
s
U S Low
t1
t
t2
Fan description
Perm. sink current
Isink max.
VDC
(+) Power
Speed signal
US High
Condition: Isource
Customer
Condition: Isink
Fan
1 Rotation
2 Pulse / Rotation
Attention:
With these fan options, deviations in regard to temperature range, voltage
range and power consumption are possible compared with standard fan data..
Signal frequenzy [F]= 2 x n/60 Hz
only for 4100 NH7 and NH8
U S High
Us
U S Low
t1
t
t2
1 Rotation
3 Pulse / Rotation
Signal frequenzy [F]= 3 x n/60 Hz
All TD NTD,
fans. Ex.:
6400
6200
6400
TD,TD
DV 6200 TD, DV 6400 TD, RER / RG 160 NTD
U S High
Us
U S Low
t1
t
t2
1 Rotation
6 Pulse / Rotation
Signal frequenzy [F]= 6 x n/60 Hz
Fa n Speed
n
nmin
112
nmax
t
Information
mA
Page
2
2,5–5,5
1
≤ 20
59
≤ 0,4
2
4,5–5,25
2
≤ 12
64
6424 /12 H
≤ 0,4
2
2,5–5,5
1
≤ 20
66
DV 6424 /12
≤ 0,4
2
4,5–5,25
2
≤ 12
68
DV 6448 /12
≤ 0,4
2
4,5–5,25
2
≤ 12
68
RG 125-19/12N/12
≤ 0,4
1
2,5–5,5
1
≤1
86
RG 160-28/12N/12
≤ 0,4
2
2,5–5,5
1
≤5
87
RG 160-28/18N/12
≤ 0,4
2
2,5–5,5
1
≤ 20
87
RER 125-19/12N/12 ≤ 0,4
1
2,5–5,5
1
≤1
96
RER 160-28/12N/12 ≤ 0,4
2
2,5–5,5
1
≤5
98
RER 160-28/18N/12 ≤ 0,4
2
2,5–5,5
1
≤ 20
98
7214 N/12
≤ 0,4
DV 6224 /12
DC fans - specials
mA
ACmaxx / i-maxx
VDC
AC axial fans
Speed signal
US Low
Type
Fan description
Perm. sink current
Isink max.
mA
Signal data
Speed signal
US High
VDC
Condition: Isink
Condition: Isource
DC centrifugal fans
DC axial fans
Available on request:
– Electrically isolated sensor and signal circuit.
– Varying voltage potentials for power and logic circuit.
113
Representatives
Accessories
AC centrifugal fans
Attention:
With these fan options, deviations in regard to temperature range, voltage
range and power consumption are possible compared with standard fan data.
Alarm signal /17
0
≤ 60
20
≤ 15
*
1500 ± 100
38
60
n > nG
0
≤ 60
20
≤ 15
*
1500 ± 100
38
2
60
n > nG
0
≤ 60
20
≤ 15
*
1500 ± 100
42
n < nG
2
60
n > nG
0
≤ 60
20
≤ 15
*
1500 ± 100
42
≤ 0,4
n < nG
2
60
n > nG
0
≤ 60
20
≤ 15
*
850 ± 100
46
≤ 0,4
n < nG
2
60
n > nG
0
≤ 60
20
≤ 15
*
1500 ± 100
49
≤ 0,4
n < nG
2
3314 /17
≤ 0,4
n < nG
3318 /17 H
≤ 0,4
4318 /17
4184 N /17 X
≤ 0,4
8318 /17 H
Condition:
60
Alarm output
voltage UA Low
2
8318 /17
min –1
Fan description
Alarm delay
time t2
n > nG
n < nG
VDC
Speed limit nG
Max. permissible
Sink current
S
VDC
Type
Condition:
Alarm operatingvoltage UBA max.
mA
mA
Alarm
signal data
Condition:
VDC
Alarm outputvoltage UA High
mA
Condition:
Isink =
Condition:
Isource
– Alarm signal for speed monitoring.
– Signal output via open collector.
– The fan emits a high continuous signal during trouble-free operation within the permissible
voltage range.
– Low signal when speed limit is not reached.
– After elimination of fault, the fan returns to its setpoint speed;
the alarm signal reverts to high.
Page
Attention: With these fan specials, deviations as regards temperature range,
voltage range and power consumption are possible compared with standard fans.
Electrical connection
Fan
Supply Voltage
UB
Customer
(+) Power
UB
t
UB
t2
+UBS
n
output
Isink
US
Speed
n>nG
nG
locked
n=0 min-1
n>nG
n>nG
n nG
0
≤ 60
20
≤ 15
*
1500 ± 100
47
2
60
n > nG
0
≤ 60
20
≤ 15
*
1150 ± 100
47
n < nG
2
60
n > nG
0
≤ 60
20
≤ 15
*
850 ± 100
47
n < nG
2
60
n > nG
0
≤ 60
15
≤ 15
*
1330 ± 60
59
60
4312/17 T
VARIOFAN
≤ 0,4
n < nG
2
4314/17 T
VARIOFAN
≤ 0,4
n < nG
4318/17 V
VARIOFAN
≤ 0,4
7214 N/17
≤ 0,4
AC axial fans
* After switching on UB
Accessories
AC centrifugal fans
Attention:
With these fan specials, deviations as regards temperature range,
voltage range and power consumption are possible compared with standard fans.
115
Representatives
2
Condition:
Alarm output
voltage UA Low
n < nG
DC fans - specials
≤ 60
≤ 0,4
Page
ACmaxx / i-maxx
0
4312/17 MV
VARIOFAN
min –1
Fan description
Alarm delaytime t2
n > nG
VDC
Speed limit nG
Max. permissible
Sink current
S
VDC
Type
Condition:
Alarm operatingvoltage UBA max.
mA
mA
Alarm
signal data
Condition:
VDC
Alarm outputvoltage UA High
mA
Condition:
Isink =
Condition:
Isource =
DC centrifugal fans
DC axial fans
Available on request:
– With integrated signal latching for subsequent recognition of short-time faults.
– Alarm circuit open collector or TTL.
– Electrically isolated for maximum device safety;
Defects in the power circuit do not affect the alarm circuit.
Alarm signal /19
Alarm delaytime t2
n < nG
0
≤ 60
20
≤ 15
*
1500 ± 100
38
60
n < nG
0
≤ 60
20
≤ 15
*
1500 ± 100
46
2
60
n < nG
0
4,5–60
10
10 ± 4
*
1800 ± 20
59
n > nG
2
≤ 28
n < nG
0
16–28
10
10 ± 4
*
1900 ± 100
84
n > nG
2
≤ 28
n < nG
0
16–28
10
10 ± 4
*
1900 ± 100
94
≤ 0,4
n > nG
2
60
4312 /19
≤ 0,4
n > nG
2
7214 N /19
≤ 0,4
n > nG
RLF 100-11/14 /19
≤ 0,4
RER 101-36/18N /19 HH
≤ 0,4
Speed limit nG
8314 /19 H
Condition:
Alarm output
voltage UA Low
VDC
Fan description
Max. permissible
Sink current
S
VDC
Type
Condition:
Alarm operatingvoltage UBA max.
mA
mA
Alarm
signal data
Condition:
VDC
Alarm output
voltage UA High
mA
Condition:
Isink =
Condition:
Isource =
– Alarm signal for speed monitoring.
– Signal output via open collector.
– The fan emits a low continuous signal during trouble-free operation within the permissible
voltage range.
– High signal when speed limit is not reached.
– After elimination of fault, the fan returns to its setpoint speed; the alarm signal reverts to
low.
min –1
Page
* After switching on UB
Attention:
With these fan specials, deviations as regards temperature range, voltage range and power consumption are possible compared with standard fans.
Available on request:
– With integrated signal latching for subsequent recognition of short-term faults.
– Alarm circuit open collector or TTL.
– Electrically isolated for max. device safety; defects in power circuit have no effect on the alarm circuit.
Electrical connection
Fan
Supply Voltage
UB
Customer
(+) Power
UB
t
UB
+UBS
t2
nG
n>nG
output
Isink
Speed
locked
n=0 min-1
n>nG
n>nG
n nG
0
≤ 28
10
nG
0
≤ 28
10
nG
Speed
n>nG
*) locked
n=0 min-1
US
t
Accessories
Fan
Supply Voltage
UB
(-) Power
UA
UAHigh
Alarm Signal
UALow
All voltages measured to ground.
External load resistor Ra from UA to UBA required.
t
t 2 = Alarm signal suppression during start-up.
* n < Speed limit nG by braking or locking.
117
Representatives
Electrical connection
AC centrifugal fans
AC axial fans
Attention:
With these fan specials, deviations as regards temperature range,
voltage range and power consumption are possible compared with standard fans.
Alarm signal /39
NG
≤ 28
10
nG
2
28
618 N /39 N
≤ 0,5
n > nG
2
3412 N/39 H
≤ 0,5
n > nG
3414 N/39 HH
≤ 0,5
n > nG
4412 F/39 GL
≤ 0,5
4412 F/39 M
≤ 0,5
614 N /39 M
Condition:
n = nG
28
≤ 0,5
612 F/39 H
Condition:
28
2
Alarm output
voltage UA Low
2
n > nG
412 /39
Fan description
0
n > nG
VDC
Speed limit nG
S
VDC
Type
Condition:
Max. permissible
Sink current Isink
mA
mA
Alarm
signal data
Alarm delaytime t2
Alarm operatingvoltage UBA max.
VDC
Alarm output
voltage UA High
mA
Condition:
Isink =
Condition:
Isource =
– Alarm signal for speed monitoring.
– Signal output via open collector.
– The fan emits a low continuous signal during trouble-free operation within the permissible
voltage range.
– High signal when speed limit is not reached.
– After elimination of fault, the fan returns to its setpoint speed;
the alarm signal reverts to low.
min –1
Page
*
*
*
*
0
25
0
28
0
31
0
31
*
*
0
40
n=max
approx. 1 V -> n=min
< 1 V -> n=0
start up at > 14 %
start up at > 1.4 V
Customer circuit
Connection
+
GND
Tach
0-10 V
PWM
Line 1
red
blue
white
violet
Line
Connection Colour Assignment / function
Line
Connection Colour Assignment / function
1
+
red
Maximum ripple ± 3.5 %
1
Tach
GND
blue
GND
white
3 pulses / revolution
0-10 V / PWM violet
122
Tach output:
Control input (Impedance 100 kΩ)
Fan
Information
against environmental influences HP
Û S
P
IP54
ACmaxx / i-maxx
Stainless steel bearings
Special bearings made of stainless steel provide
additional protection.
AC axial fans
IP 54 protection
The motor and circuit board are coated to protect them against splash water and humidity.
High protection classes up to IP 67 are available
on request.
Salt spray fog protection
Salt spray fog is extremely demanding on the
resistance of the product. ebm-papst makes
use of technologies that protect fans and blowers from salt spray fog reliably and durably.
Accessories
AC centrifugal fans
The solutions that are available and in use can differ depending on size. We would be glad to develop solutions tailored to the demands of your application.
123
Representatives
Moisture protection
A coating on the motor and printed circuit board
protects against humidity and condensation.
DC fans - specials
DC centrifugal fans
– Meeting special requirements for a broad range of applications.
– Resistant to environmental influences, such as dust, splash water, humidity, spray water and
salt spray fog.
– Highly competent solutions for adapting fans to environmental conditions.
DC axial fans
Protected fans
124
Accessories
AC centrifugal fans
AC axial fans
ACmaxx / i-maxx
DC fans - specials
ACmaxx / i-maxx overview
130
ACmaxx / i-maxx axial fans
131
125
DC axial fans
126
DC centrifugal fans
ACmaxx / i-maxx technical information
Representatives
Information
ACmaxx / i-maxx
ACmaxx / i-maxx
Technical information
Progress made by ebm-papst
The best example: The ACmaxx fans from ebm-papst, which, thanks to an
ingenious yet simple improvement over conventional AC fans, provide
substantial benefits.
The aim in developing the new ACmaxx series was to raise the technology
standard of the conventional AC fan significantly and, in the process, facilitate the transition to the new technology by retaining the overall mounting dimensions. In short, to ensure the fans can be replaced 1:1 without
any peripheral changes or changes to the voltage situation.
ebm-papst offers two generations of ACmaxx products that meet different
needs.
AC
ACmaxx
i-maxx
What ACmaxx and i-maxx have in common:
Energy efficiency
Long service life
The drive concept is based on state-of-the-art GreenTech EC technology
with outstanding motor efficiency. Compared to AC fans of the same size,
ACmaxx energy consumption is up to 77% lower–for higher cooling capacity! The energy balance alone means that the products pay for themselves after only a few months. The savings over the entire service life, especially in systems with multiple fans, is considerable.
The efficiency of ACmaxx and i-maxx motors is up to 75% higher than that
of conventional AC fan variants. This not only saves energy, it also means
less intrinsic heating in the motor. The reduced heating has a direct, positive effect on the bearing system, which is why the fans have a service life
that is up to 85% longer! This also lengthens the service and maintenance
intervals significantly. The expense of replacement fans, and even more
expensive downtimes, are kept to a manageable minimum.
[ EUR ]
h
60
AC
40
N
000
4
80000
70000
70000
20
AC 4300
60000
ACi 4400
50000
88% increase
in life time
40000
37500
0
0
1
2
3
Years
30000
20000
The ACmaxx and i-maxx fans are prepared for direct connection to all AC
voltages and frequencies. The speed, and thus important properties of the
fan such as air flow and noise, are independent of the power frequency
and do not change, even within the defined voltage range. Voltage fluctuations in the power system are automatically compensated for.
126
10000
Service
Life
Independent of mains frequency and mains voltage
AC Standard
ACmaxx
Information
i-maxx is more efficient!
ACmaxx saves energy, and the i-maxx generation saves even more. While
an AC fan at 50 Hz can barely reach an overall efficiency of 5-6%, the
ACmaxx makes it to approx. 20-25%. With the new i-maxx ACi 4400, a
remarkable level of up to 30% is reached. This is the result of the optimisation of the entire package made up of drive, electronics, AC/DC conversion and aerodynamics. Thus the new i-maxx series boasts energy savings
of almost 75% compared to the corresponding AC fan, thus providing significantly higher savings than the 40% level of the old AC 4300 generation.
ACmaxx / i-maxx
Safety
• Safety certifications: UL, CSA and VDE 0805 / EN60950.
VDE 0700 / EN60335 on request.
• Our fans have the CE mark of conformity.
• EMC protection:
> EN61000-4-4 Level 1 (1 kV or 2 kV)B
> EN61000-4-2 Level 8 kV/15 kV or 4 kV/8 kV
> EN61000-4-3
> EN61000-4-6
> EN61000-4-8
> EN55022 Class B
Use
Use
[%]
80
60
AC axial fans
Saving
40
Saving
Use
Ambient influences
AC fans are extremely common and are used in a wide variety of applications. In control cabinet cooling, beer coolers, cooling cabinets, wood-burning stoves, medical devices – all have different requirements for resistance to ambient influences. ACmaxx and i-maxx fans offer the same
features for protection against moisture, splash water and rough ambient
conditions.
DC fans - specials
DC centrifugal fans
DC axial fans
ACmaxx / i-maxx
20
AC 4000 N
AC 4300
ACi 4400
Speed independent of voltage and frequency
For the i-maxx ACi 4400, the speed, and thus the air flow and operating
noise, are independent of the supply voltage and power frequency.
Versions are available for 115 VAC with a voltage range from 85 to 132
VAC and 230 VAC with a voltage range of 195 to 265 VAC. Voltage fluctuations and frequency differences in the power system are compensated for
automatically.
ACmaxx
i-maxx
127
Accessories
i-maxx is quieter!
The i-maxx ACi 4400 is quieter! Quieter than AC fans and quieter than the
existing ACmaxx generation. The reason for this is the optimised aerodynamics and the drive, which is optimised for minimum structure-borne
noise. Thus the fan is only half as loud at comparable air performance,
and is up to 6 dB(A) quieter at some operating points.
Representatives
i-maxx is more compact!
As large as existing AC fans – and not a bit larger. This is the most outstanding feature of the new i-maxx ACi 4400. Even in the hub area, the
fan does not differ from typical 119x119x38 mm AC fans. Out with the
AC, in with the i-maxx ACi 4400 – it's that simple.
AC centrifugal fans
Particular design features of the i-maxx (ACi 4400):
ACmaxx / i-maxx
Technical information
Particular design features of the ACmaxx:
Higher flexibility
The flexibility of ACmaxx is one-of-a-kind. With its intelligent features,
ACmaxx can be individually adapted to the specific application: standby
mode, overload mode at peak times or night reduction all the way to temperature-controlled quiet operation are all possible. From speed setting to
alarm or speed signal outputs, ACmaxx offers optional interfaces with
which you can quickly and easily implement operation monitoring.
128
Pa
[in H2O]
Or you can simply contact our application engineers to discuss your ideal
ACmaxx or i-maxx fan.
100
0,4
75
0,3
125
0,5
150
50
0,2
Higher performance
Unlike conventional AC technology, the state-of-the-art drive concept of
this fan series is not linked to a fixed power frequency. This allows the
motor speed to be increased over a wide range. Thus ACmaxx provides
significantly higher air flow and significantly increased pressure.
You can find further information about these fan options in the
"Specialised fans" chapter, starting on page 107.
25
0,1
Prepared for all AC voltages
These models have a very wide voltage range from 85 to 265 VAC – the
global voltage range, so to speak. This enables the fan to be used around
the world, opening up large savings potentials. In addition to reduced logistics effort and stock-keeping, worldwide availability is key. ACmaxx is
compatible with every supply voltage–no switching needed. From 85 to
265 volts and mains frequencies of 50 and 60 hertz. Voltage fluctuations
in the power system are automatically compensated for.
0
ACmaxx
120 mm
Standard AC fans
120 mm
30
60
90
120
50
100
150
200
150
250
CFM
m³/h
Information
DC centrifugal fans
DC axial fans
Optional special versions
Information on pictograms
DC fans - specials
On the pages of the catalogue and on the following overview pages, the pictograms illustrated below provide information about technically possible special versions in the fan line presented.
Please note that these special versions are not possible for all voltages and speeds, and not in all combinations.
The special versions are designed for specific customers and projects and are not usually available off the shelf.
PWM control input
Go / No-go alarm
The fan uses a separate wire to output a static signal
Analogue control input
when it is stationary, thus providing information about
A
The speed of the fan can be changed via a control voltage. This control voltage is applied to a specially provided
details, please refer to page 117.
wire. For technical details, please refer to page 121.
Alarm with limit speed
Multi-option control input
If the speed drops below a certain level defined in the
The fan has a control input that the user can trigger eit-
fan's electronics, the fan will emit a static signal, thus
her using a PWM signal, an analogue signal or a
providing information about whether or not the rotor is
resistor. For technical details, please refer to page 122.
External temperature sensor
An NTC is connected to the fan via a separate wire and
HP
the fan changes its speed depending on the temperature at the NTC. For technical details, please refer to
page 120.
Internal temperature sensor
Protection against moisture
Protection for the fan's electronics against moisture and
condensation. For technical details, please refer to page
123.
Û
IP54
IP 54
Protection of motor and PCB board against splashed
water and humidity. For technical details, please refer to
In this case, the NTC is integrated into the fan and the
page 123.
fan changes its speed depending on the temperature at
Protection against salt spray fog
the NTC. For technical details, please refer to page
120.
SP
ACmaxx / i-maxx
provided wire. For technical details, please refer to page
121.
turning. For technical details, please refer to page 114.
I
modulated signal. This signal is applied to a specially
For technical details, please refer to page 110.
whether or not the rotor is turning. For technical
T
The speed of the fan can be changed via a pulse-width-
Accessories
NG
PWM
AC axial fans
about its speed, and thus about the speed of the rotor.
AC centrifugal fans
The fan uses a separate wire to output information
Protection of fan against the damaging effects of salt
spray fog. For technical details, please refer to page
123.
129
Representatives
Speed signal
Fans for AC operation
Page
Air flow
Series
Dimension
Overview of air performance
m3/h 10
mm
80 x 32
AC 8300 H
92 x 38
AC 3200 J
119 x 25
AC 4400 FN
119 x 32
AC 4300 H
20
80
30
40
50
60
70 80 90 100
200
300
400
500 600 700 800 900 1000
2000
3000
108
131
144
109
132
205
110
133
204
134
ACi 4400 100..180
135
172 Ø x 51
AC 6100 N
350
136
172 Ø x 51
AC 6200 N
350
137
NEW 98,5 Ø x 130 AC 100 NR 80..135
138
NEW 119 x 38
aring
Go /
mm
AC 8300 H
80 x 80 x 32
*
•
•
•
•
•
•
•
–
•
•
•
131
AC 3200 J
92 x 92 x 38
*
•
•
•
•
•
•
•
–
•
•
•
132
AC 4400 FN
119 x 119 x 25
*
•
•
•
•
•
•
•
–
•
–
–
133
AC 4300
119 x 119 x 32
*
•
•
•
•
•
•
•
–
•
•
•
134
NEW ACi 4400
119 x 119 x 38
–
–
–
–
–
–
–
–
•
•
•
135
VDE
Sinte
Series
Dim
Sens
or
ve be
c slee
ensi
, UL,
on
CSA
s / ba
ll bea
No-g
o ala
Alarm
rm
with
limit
spee
Exte
d
rnal
temp
eratu
Inter
nal t
re se
emp
nsor
e
ratu
PWM
re se
cont
n
sor
rol in
Anal
put
ogue
cont
Mult
rol in
i-op
put
tion
cont
rol in
Hum
put
idity
prot
ectio
IP >
n
= IP
54
Salt
spra
y fog
prot
ectio
Page
n
rings
Overview of technically feasible designs
ACmaxx / i-maxx Axial fans
OPTIONAL
P.
AC 6100 N
172 Ø x 51
*
•
•
•
•
•
•
•
–
•
•
•
136
AC 6200 N
172 Ø x 51
*
•
•
•
•
•
•
•
–
•
•
•
137
–
–
–
–
–
–
–
–
•
•
–
138
NEW AC 100
100 Ø x 130
– not yet available
• available
Sleeve bearings
Ball bearings
* Partially granted, partially in registration stage.
Please note that these special versions are not possible for all voltages and speeds, and not in all combinations. The special versions are designed for specific customers and projects. As a rule they are not available
off the shelf and are tied to minimum volumes.
Please consult your customer support representative about the feasibility of your special variant.
130
Information
ACmaxx axial fans
Series AC 8300 H
80 x 80 x 32 mm
/
Watts
RPM
°C
85 ... 265
48
6,2
/
7,5
5 000
-20...+75
115 / 230 50 / 60
DC axial fans
DC centrifugal fans
Bel(A)
Hours
Hours
55 000 / 25 000
Curve
dB(A)
at T max
VAC
Service life L10
at 40 °C
Nominal speed
Hz
Temperature range
Power input
47,1
Sintec sleeve bearings
Ball bearings
80
AC 8300 H
Sound power level
V
Sound pressure level
Type
Voltage range
CFM
Nominal data
Frequency
Nominal voltage
m3/h
Air flow
Air flow
Highlights:
– Universally suitable for all AC voltages between 85 and 265 V.
– Fan speed not dependent on line frequency.
– Significantly reduced power consumption compared to conventional AC fans.
– Open loop speed control, sensor and alarm signal possible on request.
General attributes:
– Material: fibreglass-reinforced plastic. PA impeller, PBTP housing.
– Fully integrated electronic commutation.
– Protected against locking.
– Connection via single strands AWG 22, TR 64. Bared and tin-plated.
– Air exhaust over struts. Direction of rotation clockwise, seen on rotor.
– Mass: 325 g.
1
DC fans - specials
80 m3/h
max.
1
Accessories
0,3
0,2
60
20
0,1
40
5
22
32 + 0,3
0
8
10
16
20
30
24
40
32
50
40
60
64 + 0,5
CFM
m³/h
NG
T
I
PWM
A
HP
Û S
P
IP54
131
Representatives
80
0,4
120
100
AC centrifugal fans
[in H2O]
Pa
AC axial fans
ACmaxx / i-maxx
Speed variants available on request.
ACmaxx axial fans
144 m3/h
max.
Series AC 3200 J
92 x 92 x 38 mm
Service life L10
at 40 °C
at T max
Hz
VAC
dB(A)
Bel(A)
/
Watts
RPM
°C
Hours
Hours
85 ... 265
55
6,4
/
11
6 800
-20...+70
HP
IP54
115 / 230 50 / 60
Pa
[in H2O]
Speed variants available on request.
1
0,1
40
0,2
80
0,3
0,4
120
0,5
160
0,6
0,7
61.7+ 0.2
54.2 + 0.15
200
6+ 0.3
6+ 0.3
38 + 0.5
0
15
20
132
30
40
45
60
80
60
100
75
120
NG
70.7 + 0.8
0.3
CFM
m³/h
T
I
PWM
A
Û S
P
70 000 / 35 000
Curve
Temperature range
84,8
Nominal speed
144
Power input
AC 3200 JH
Sintec sleeve bearings
Ball bearings
V
Sound power level
CFM
Sound pressure level
Nominal voltage
m3/h
Voltage range
Air flow
Type
Nominal data
Frequency
Air flow
Highlights
– Universally suitable for all AC voltages between 85 and 265 V.
– Fan speed independent of power frequency.
– Significantly reduced power consumption compared to conventional AC fans.
– Open loop speed control, sensor and alarm signal possible on request.
– Rigid compression curve for high air flow at high back pressure.
– Innovative impeller with winglets for low noise levels.
General attributes:
– Material: fibreglass-reinforced plastic. PA impeller, PBTP housing.
– Fully integrated electronic commutation. Protected against locking.
– Connection via single strands AWG 22, TR 64. Bared and tin-plated.
– Air exhaust over struts. Direction of rotation clockwise, seen on rotor.
– Mass: 325 g.
1
Information
ACmaxx axial fans
Series AC 4400 FN
119 x 119 x 25 mm
DC axial fans
at T max
DC centrifugal fans
Service life L10
at 40 °C
Hz
VAC
dB(A)
Bel(A)
/
Watts
RPM
°C
Hours
Hours
85 ... 265
53
6,2
/
12
4 850
-20...+70
115 / 230 50 / 60
60 000 / 30 000
Curve
Temperature range
120,7
Nominal speed
205
Power input
AC 4400 FNN
Sintec sleeve bearings
Ball bearings
V
Sound power level
CFM
Sound pressure level
Nominal voltage
m3/h
Voltage range
Air flow
Type
Nominal data
Frequency
Air flow
Highlights:
– Universally suitable for all AC voltages between 85 and 265 V.
– Fan speed independent of power frequency.
– Significantly reduced power consumption compared to conventional AC fans.
– Open loop speed control, sensor and alarm signal possible on request.
– Rigid compression curve for high air flow at high back pressure.
– Innovative impeller with winglets for low noise levels.
General attributes:
– Material: fibreglass-reinforced plastic. PA impeller, PBTP housing.
– Fully integrated electronic commutation. Protected against locking.
– Connection via single strands AWG 22, TR 64. Bared and tin-plated.
– Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor.
– Mass: 370 g..
1
DC fans - specials
205 m3/h
max.
150
Accessories
0,5
0,2
25
25.4 + 0.15
0
30
50
60
100
90
150
120
200
150
250
CFM
m³/h
57.9
+ 0.5
NG
T
I
PWM
A
HP
133
Representatives
50
0,1
75
0,4
100
1
0,3
125
AC centrifugal fans
[in H2O]
Pa
AC axial fans
ACmaxx / i-maxx
Speed variants available on request.
ACmaxx axial fans
204 m3/h
max.
Series AC 4300
119 x 119 x 32 mm
dB(A)
Bel(A)
/
Watts
120,1
115 / 230 50 / 60
RPM
°C
Hours
Hours
85 ... 265
51
6,4
/
11
3 400
-20...+70
HP
IP54
0,2
O
60
O
54
52,7
0,3
1
80
max. 0,4 mm
Rotorüberstand
Rotor
protrudes
[in H2O]
Pa
Speed variants available on request.
0,1
40
20
22
0
134
15
30
45
60
75
90
CFM
25
50
75
100
125
150
m³/h
NG
64 + 0,6
T
I
PWM
A
Û S
P
45 000 / 22 500
Curve
VAC
at T max
Hz
Service life L10
at 40 °C
Power input
V
Temperature range
Sintec sleeve bearings
Ball bearings
CFM
Nominal speed
Sound power level
204
Sound pressure level
AC 4300 H
Voltage range
m3/h
Frequency
Type
Nominal voltage
Nominal data
Air flow
Air flow
Highlights:
– Universally suitable for all AC voltages between 85 and 265 V.
– Fan speed independent of power frequency.
– Significantly reduced power consumption compared to conventional AC fans.
– Open loop speed control, sensor and alarm signal possible on request.
General attributes:
– Material: fibreglass-reinforced plastic. PA impeller, PBTP housing.
– Fully integrated electronic commutation.
– Protected against locking.
– Connection via single strands AWG 22, TR 64. Bared and tin-plated.
– Air exhaust over struts. Direction of rotation clockwise, seen on rotor.
– Mass: 325 g.
1
Information
180 m3/h
max.
i-maxx axial fans
Series ACi 4400
119 x 119 x 38 mm
DC axial fans
DC centrifugal fans
Hours
DC fans - specials
Hours
100
58,8
230
195...265
25
4,1
1,4
1 850
-20...+75
80 000 / 30 000
160 000
1
NEW ACi 4420 H
160
94,1
230
195...265
39
5,1
3,3
3 000
-20...+75
70 000 / 30 000
140 000
2
NEW ACi 4420 HH
180
105,9
230
195...265
42
5,3
4,4
3 350
-20...+75
62 500 / 30 000
125 000
3
NEW ACi 4410 HH
180
105,9
115
85...132
42
5,3
4,4
3 350
-20...+75
62 500 / 30 000
125 000
3
AC centrifugal fans
AC axial fans
NEW ACi 4420 ML
ACmaxx / i-maxx
°C
(40 °C)
RPM
Curve
Life expectancy L10Δ
Service life L10 (Tmax)
ebm-papst Standard
Service life L10 (40 °C)
ebm-papst Standard
Watts
Temperature range
/
dB(A) Bel(A)
Nominal speed
VAC
Power input
VAC
Sintec sleeve bearings
Ball bearings
CFM
Sound power level
Voltage range
m3/h
Sound pressure level
Nominal voltage
Type
Air flow
Nominal data
Air flow
Highlights:
– Energy efficient AC fan with EC technology.
– Conversion and drive electronics fully integrated.
– Significant lower power consumption than existing AC fans.
– Significantly lower noise than existing AC fans.
– Significant higher service life than existing AC fans.
– Fan speed not dependent on line frequency.
General characteristics:
– Material: fibreglass-reinforced plastic. Impeller PA, housing PBT.
– Electronic locked rotor protection.
– Electrical connection via 2 flat plugs 2,8 x 0,5 mm, flying leads optional.
– Air exhaust over struts, direction of rotation clockwise, seen on rotor.
– Mass: 250 g.
38 +0,5
Pa
[in H2O]
6 +0,3
6 +0,3
3
60
Accessories
0,20
2
0,10
40
1
0
20
20
40
50
60
100
80
100
150
CFM
m³/h
HP
Û S
P
IP54
135
Representatives
0
ACmaxx axial fans
350 m3/h
max.
Series AC 6100 N
172 ø x 51 mm
Service life L10
at 40 °C
at T max
Hz
VAC
dB(A)
Bel(A)
/
Watts
RPM
°C
Hours
Hours
85 ... 265
52
6,1
/
14
2 850
-20...+70
HP
IP54
115 / 230 50 / 60
Speed variants available on request.
(32.5)
50.8 +0.2
Pa
[in H2O]
Förderrichtung
50
0,2
25
0,1
75
0,4
100
1
0,3
125
0,5
150
3 +0.2
27.5
0
40
80
100
136
120
200
160
200 CFM
300
NG
83.3+0.6
m³/h
T
I
PWM
A
Û S
P
80 000 / 37 500
Curve
Temperature range
206,0
Nominal speed
350
Power input
AC 6100 NM
Sintec sleeve bearings
Ball bearings
V
Sound power level
CFM
Sound pressure level
Nominal voltage
m3/h
Voltage range
Air flow
Type
Nominal data
Frequency
Air flow
Highlights:
– Universally suitable for all AC voltages between 85 and 265 V.
– Fan speed independent of power frequency.
– Significantly reduced power consumption compared to conventional AC fans.
– Open loop speed control, sensor and alarm signal possible on request.
General attributes:
– Material: fibreglass-reinforced PA housing and impeller.
– Fully integrated electronic commutation.
– Protected against locking.
– Connection via single strands AWG 22, TR 64. Bared and tin-plated.
– Air exhaust over struts. Direction of rotation clockwise, seen on rotor.
– Mass: 760 g.
1
Information
ACmaxx axial fans
350 m3/h
max.
Series AC 6200 N
172 ø x 51 mm
dB(A)
Bel(A)
/
Watts
RPM
°C
Hours
Hours
85 ... 265
50
5,7
/
14
2 850
-20...+70
115 / 230 50 / 60
80 000 / 40 000
1
DC centrifugal fans
at T max
VAC
DC fans - specials
Service life L10
at 40 °C
Hz
Curve
Temperature range
206,0
Nominal speed
350
Power input
AC 6200 NM
Sintec sleeve bearings
Ball bearings
V
Sound power level
CFM
Sound pressure level
Nominal voltage
m3/h
Voltage range
Air flow
Type
Nominal data
Frequency
Air flow
– Universally suitable for all AC voltages between 85 and 265 V, 50-60 Hz.
– Fan speed independent of power frequency.
– Significantly reduced power consumption compared to conventional AC fans.
– Open loop speed control, sensor and alarm signal possible on request.
General attributes:
– Material: aluminium housing, fibreglass-reinforced PA impeller. Housing with grounding lug
for screw M4 x 8 (Torx).
– Fully integrated electronic commutation.
– Protected against locking.
– Connection via single strands AWG 22, TR 64. Bared and tin-plated.
– Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor.
– Mass: 900 g.
DC axial fans
Highlights:
AC centrifugal fans
AC axial fans
ACmaxx / i-maxx
Speed variants available on request.
166
50
100
100
CFM
150
200
300
63,7
Accessories
0,1
0
15 30,5 +0,2
m³/h
NG
T
I
PWM
A
HP
Û S
P
IP54
137
Representatives
0,2
25
7,5
7,5
10
0,4
50
0,8
0,8
74
75
1
0,3
Pa
100
[in H2O]
83,3 +0,6
ACmaxx in-line duct fan
135 m3/h
max.
Series AC 100 NR
Ø 98,5 x 130 mm
Air flow
Nominal voltage
Frequency
Voltage range
Sound pressure level
Sound power level
Sintec sleeve bearings
Ball bearings
Power input
Nominal speed
Temperature range
Service life L10
at 40 °C
at T max
m3/h
CFM
V
Hz
VAC
dB(A)
Bel(A)
/
Watts
RPM
°C
Hours
Hours
80
47,1
105
61,8
Nominal data
Type
AC 100 NR
115/230
50-60
85...265
Pa
70
60
[in H2O]
Optional: Max. speed at 135 m3/h (Curve 3).
2
50
40
30
20
3
0,16
boost
0,12
nominal
1
0,08
NEW
10
0
20
20
138
40
40
60
60
80
HP
80
100
120
Û
IP44
CFM
m³/h
35
4,7
2,5
2 750
42
5,3
4,5
3 500
-10...+55
70 000 / 40 000
Curve
Air flow
Highlights:
– Highest energy efficiency thanks to EC technology.
– Protection class IP44 (IP45 possible depending on mounting position).
– Speed-boost function via mains voltage switch.
– Vibration-isolated motor.
– Global voltage - one product applicable for all line voltages and frequencies
between 85-265 VAC and 50/60 Hz. Fan speed independent from power frequency.
General features:
– Material: fibreglass-reinforced plastic, housing PP, impeller PA.
– Electrical connection via 3-pole terminal block, max. 1.5 mm2.
– Protection class 2.
– Approvals: VDE 60335-3-80. UL, CE, CSA on request.
– Mass: 400 g.
1
2
Information
DC axial fans
0.03 - 0.045 W/m3/h free air (Specific fan power).
2 speed settings possible via boost function.
Reduced transmission of vibrations from motor to housing.
Speed settings and control outputs optional.
DC centrifugal fans
Highest energy efficiency:
Boost speed setting:
Vibration isolation:
Intelligence:
Connection
N
L
L
Example 3:
Simple connection,
nominal speed
without switching.
ACmaxx / i-maxx
N
DC fans - specials
Example 2:
Nominal speed via light
switch, separate boost
switch.
N
L
L
AC centrifugal fans
N
AC axial fans
Example 4:
Simple connection, boost
speed without switching.
Accessories
Scope of delivery
139
Representatives
Example 1:
Continuous operation at
nominal speed boost
speed via light switch.
140
Accessories
AC centrifugal fans
AC axial fans
ACmaxx / i-maxx
DC fans - specials
143
AC axial fans
144
141
DC centrifugal fans
AC axial fan overview
Representatives
DC axial fans
Information
AC axial fans
AC fans
Technical information
Product line
The renowned ebm-papst AC fans are used
when DC voltage is not available. The AC range
of fans is based on experience gained from
decades of development activity, millions of
units in series production and competence in
innovation of a world-wide technological leader.
A wide range of fans for AC operation is presented in this catalogue. In addition to complete
device fans, you will also find fans without
external housing, providing a particularly economical advantage when the air duct can be
integrated in the respective device.
Variety of sizes
AC fans are available in a variety of sizes with
either air exhaust or air intake over struts.
Silent running models with sleeve bearings or
for extreme ambient conditions; fans with ball
bearings are available with plug connection or
external leads.
Shaded-pole or capacitor motors
Fan drives by shaded-pole or capacitor motors,
most of which incorporate the world-famous
ebm-papst external rotor principle: The fan
blades are directly attached to the external rotor
of the external rotor motor, thus combining both
high performance and profitability.
Flat built AC fans
ebm-papst also has particularly flat built AC
fans with internal rotor motor. Their advantage:
quick start to full speed. A plastic impeller and
the both smaller and lighter internal rotor motor
lead to a lower moment of inertia.
142
Bearings
AC fans with sleeve bearings are powered by
Class E insulated motors. Fans with ball
bearings are equipped with Class B, E or F
insulated motors.
Protection class
All ebm-papst fans conform to the requirements
of IP 20. Fans conforming to IP 54 and special
types of protection class are also available.
AC voltage
The line of AC fans for Euro voltage according
to IEC 60038 (230 V + 6 %, -10 %) is basically
also available for 115 V.
Frequencies
AC fans can be operated at frequencies of 50
Hz or 60 Hz. However, their technical data then
changes accordingly.
Capacitor
Fans driven by capacitor external motors
provide particularly high operating efficiency.
Generally, the required operating capacitor is
already integrated in the fan housing.
Overloading
Almost all AC fans are protected against overloading (e.g. due to locked rotor) the drive
motors are either impedance protected (marked
“Impedance protected”, and/or “Z.P.”) or are
equipped with a thermal switch (marked
“Thermally protected” or “Th.P.”). The model
designation of these fans ends with “S”.
Information
Axial fans for AC operation
20
30
50
40
60
70 80 90 100
200
300
400
500 600 700 800 900 1000
2000
3000
80 x 38
8000 A
29...57
144
80 x 38
8000 N
30...61
145
Ø
76 x 37
8000 TA
23...45
146
Ø
76 x 37
8000 TV
24...47
147
92 x 25
3900
31...70
148
92 x 38
3000
49...89
149
119 x 25
9900
84...135
150
119 x 38
4000 N
80...180
151
119 x 38
4000 Z
100...180
152
153
108 x 37
4600 TZ
125...140
154
127 x 38
5900
150...206
135 x 38
5600
235...270
156
150 x 172 x 38
7000
330...390
157
Ø
150 x 55
7800
325...380
158
Ø
150 x 55
7400
390...445
159
Ø
172 x 51
6000
375...500
160
Ø
225 x 80
W**200
450...1030
161
W2E 250
1865
162
280 x 80
129
155
• available
mm
8000 A
80 x 80 x 38
yes
/
–
8000 N
80 x 80 x 38
yes
/
–
8000 TA
76 Ø x 37
yes
/
–
8000 TV
76 Ø x 37
yes
/
–
3900
92 x 92 x 25
yes
/
–
3000
92 x 92 x 38
yes
/
–
9900
119 x 119 x 25
yes
/
–
4000 N
119 x 119 x 38
yes
/
4000 Z
119 x 119 x 38
yes
/
•
•
4600 TA
113 Ø x 37
yes
/
–
4600 TZ
108 Ø x 37
yes
/
–
5900
127 x 127 x 38
yes
/
5600
135 x 135 x 38
yes
7000
150 x 172 x 38
7800
7400
6000
prot
On the pages of the catalogue and on the following overview pages, the
sible special versions in the fan line presented.
Please note that these special versions are not possible for all voltages
Axial fans
Series
Information on pictograms
pictograms illustrated below provide information about technically pos-
Page
Salt
spra
y fog
ectio
prot
54
idity
= IP
IP >
nsor
Hum
d se
Spee
VDE
Dim
, UL,
ensio
n
CSA
Sinte
c
ball sleeve b
bear earing
ings
s/
n
ectio
n
Overview of technically feasible designs
OPTIONAL
P.
and speeds, and not in all combinations.
•
•
•
•
•
•
•
•
144
The special versions are designed for specific customers and projects
145
and are not usually available off the shelf.
–
–
148
•
•
149
The fan uses a separate wire to output information about its
–
–
150
speed, and thus about the speed of the rotor. For technical
•
•
•
•
•
•
•
•
151
–
–
155
–
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
156
yes
–
–
–
–
157
150 Ø x 55
yes
•
–
–
–
158
150 Ø x 55
yes
–
–
–
–
159
172 ¯ x 51
yes
–
–
–
–
160
– not yet available
Sleeve bearings
–
DC fans - specials
Ø
ACmaxx / i-maxx
138...147
AC axial fans
4600 TA
146
147
Speed signal
details, please refer to page 110.
152
153
154
HP
Protection against moisture
Protection for the fan's electronics against moisture and
AC centrifugal fans
113 x 37
condensation. For technical details, please refer to page 123.
Û
IP54
IP 54
Protection of motor and PCB board against splashed water
and humidity. For technical details, please refer to page 123.
Ball bearings
SP
Protection against salt spray fog
Accessories
Ø
DC axial fans
10
Protection of fan against the damaging effects of salt spray
fog. For technical details, please refer to page 123.
143
Representatives
m3/h
mm
DC centrifugal fans
Page
Air flow
Series
Dimension
Overview of air performance
57 m3/h
AC axial fans
Series 8000 A
Temperature range
Service life L10
at 40 °C
9,0
1 750
-10...+80
60 000 / 25 000
1
/
12,5
2 150
-10...+70
52 500 / 25 000
2
5,0
/
12,0
2 700
-10...+70
52 500 / 25 000
3
37
5,1
/
12,0
2 800
-40...+90
52 500 / 15 000
3
60
29
4,3
/
8,0
1 950
-10...+80
62 500 / 25 000
4
115
60
34
4,8
/
11,0
2 500
-10...+70
55 000 / 27 500
5
115
60
41
5,5
/
11,0
3 200
-10...+75
55 000 / 25 000
6
115
60
42
5,7
/
11,0
3 300
-40...+95
55 000 / 15 000
6
m3/h
CFM
V
Hz
dB(A)
Bel(A)
8880 A
29
17,1
230
50
26
4,1
8850 A
36
21,2
230
50
31
4,6
8550 A
48
28,3
230
50
36
8556 A
48
28,3
230
50
8830 A
34
20,0
115
8800 A
45
26,5
8500 A
57
33,5
8506 A
57
33,5
Nominal data
Type
0,15
Pa
40
[in H2O]
Series 8000 A with
reinforced flanges
3
6
0,10
30
20
0,05
10
2
5
1
0
4
5
10
10
15
20
20
30
25
40
50 Hz
144
HP
30
50
CFM
m³/h
60 Hz
Û S
P
IP54
Curve
Nominal speed
/
Sound power level
Hours
Sound pressure level
°C
Frequency
RPM
Nominal voltage
Watts
Air flow
/
Air flow
Power input
AC fans with external rotor shaded-pole motor. Impedance protected against overloading.
Metal fan housing and impeller.
Air intake over struts. Direction of rotation clockwise, seen on rotor.
Electrical connection via 2 flat plugs 2.8 x 0.5 mm.
Fan housing with grounding lug and screw M4 x 8 (TORX).
Mass: 490 g.
Optionally available with electrical connection via leads.
Optionally available with air exhaust over struts and clockwise direction of rotation.
Please note our new ACmaxx series. With identical mounting dimensions and voltages, this
series achieves higher energy efficiency.
Sintec sleeve bearings
Ball bearings
–
–
–
–
–
–
–
–
–
80 x 80 x 38 mm
at T max
max.
Hours
Service life L10
at 40 °C
60 000 / 25 000
1
-10...+70
52 500 / 25 000
2
4,4
/
12,0
2 700
-10...+70
52 500 / 25 000
3
31
4,5
/
12,0
2 800
-40...+90
52 500 / 15 000
3
60
21
3,7
/
8,0
1 950
-10...+80
62 500 / 25 000
4
115
60
28
4,3
/
11,0
2 500
-10...+70
55 000 / 27 500
5
115
60
34
4,8
/
11,0
3 200
-10...+75
55 000 / 25 000
6
115
60
35
5,0
/
11,0
3 300
-40...+95
55 000 / 15 000
6
dB(A)
Bel(A)
8880 N
30
17,7
230
50
18
3,3
8850 N
37
21,8
230
50
24
3,9
8550 N
50
29,4
230
50
30
8556 N
50
29,4
230
50
8830 N
36
21,2
115
8800 N
47
27,7
8500 N
61
35,9
8506 N
61
35,9
Fan type
8830 N
Lead wires
8800 N
8880 N
8556 N
8500 N
310 mm long
AWG 18, TR 64
310 mm long
AWG 18, TR 64
310 mm long
AWG 22
440 mm long
AWG 18, TR 64
AC centrifugal fans
60
6
2
Accessories
0,20
3
0,15
5
0,10
30
4
20
1
0,05
10
0
5
10
10
15
20
20
30
25
40
50 Hz
30
50
CFM
m³/h
60 Hz
HP
Û S
P
IP54
145
Representatives
40
8506 N
8550 N
[in H2O]
Pa
8850 N
Hours
ACmaxx / i-maxx
Hz
50
Information
Temperature range
-10...+80
2 150
V
Curve
Nominal speed
1 750
12,5
CFM
Type
at T max
Power input
9,0
/
Sound power level
/
Sound pressure level
Hours
Frequency
°C
Nominal voltage
RPM
Air flow
Watts
Air flow
/
m3/h
Nominal data
DC centrifugal fans
AC fans with external rotor shaded-pole motor. Impedance protected against overloading.
Metal fan housing and impeller.
Air exhaust over struts. Direction of rotation clockwise, seen on rotor.
Electrical connection via 2 leads. Bared and tin-plated.
Fan housing with grounding lug for screw M4 x 8 (TORX).
Mass: 490 g.
Please note our new ACmaxx series. With identical mounting dimensions and voltages, this
series achieves higher energy efficiency.
Sintec sleeve bearings
Ball bearings
–
–
–
–
–
–
–
80 x 80 x 38 mm
DC fans - specials
Series 8000 N
DC axial fans
AC axial fans
AC axial fans
61 m3/h
max.
45 m3/h
AC axial fans
Series 8000 TA
Service life L10
at 40 °C
9,0
1 650
-10...+80
60 000 / 25 000
–
/
12,0
2 100
-10...+70
52 500 / 25 000
–
25
/
12,0
2 650
-10...+70
52 500 / 25 000
–
50
26
/
12,0
2 750
-40...+90
52 500 / 15 000
–
115
60
18
/
8,0
1 850
-10...+80
62 500 / 25 000
–
20,0
115
60
23
/
11,0
2 450
-10...+70
55 000 / 27 500
–
26,5
115
60
30
/
11,0
3 150
-10...+75
55 000 / 25 000
–
26,5
115
60
31
/
11,0
3 250
-40...+95
55 000 / 15 000
–
8800 TA
325 mm long
AWG 18, TR 64
CFM
V
Hz
dB(A)
8880 TA
23
13,5
230
50
15
8850 TA
30
17,7
230
50
19
8550 TA
38
22,4
230
50
8556 TA
38
22,4
230
8830 TA
26
15,3
8800 TA
34
8500 TA
45
8506 TA
45
Type
The air flow and noise level of fans without external housing depends on the installation conditions. The stated air
flow and noise has been measured with an orifice 76.5
mm Ø at a distance of approx. 17 mm from the mounting
bracket. Under exceptionally favourable mounting conditions, the air flow of fan series 8000 A is achievable. The
noise in the optimal operating range can only be measured
for these fans in a specific application.
Fan type
8880 TA
8850 TA
8550 TA
8500 TA
325 mm long
AWG 18, TR 64
8556 TA
8506 TA
325 mm long
AWG 18
37 +1
10
ø75,8
325 +10
6 +1
HP
Û S
P
IP54
R4
101 + 0,2
0,3
3
146
Hours
Lead wires
8830 TA
90°
Curve
Temperature range
/
m3/h
Nominal data
at T max
Nominal speed
Hours
Sound pressure level
°C
Frequency
RPM
Nominal voltage
Watts
Air flow
/
Air flow
Power input
AC fans with external rotor shaded-pole motor. Impedance protected against overloading.
Impeller and mounting bracket of metal.
Air intake over mounting bracket. Direction of rotation clockwise, seen on rotor.
Electrical connection via 2 leads. Bared and tin-plated.
Mass: 370 g.
Please note our new ACmaxx series. With identical mounting dimensions and voltages, this
series achieves higher energy efficiency.
Sintec sleeve bearings
Ball bearings
–
–
–
–
–
–
76 Ø x 37 mm
3,7 + 0,15
max.
Information
Nominal speed
Temperature range
Service life L10
at 40 °C
9,0
1 650
-10...+80
60 000 / 25 000
–
/
12,0
2 100
-10...+70
52 500 / 25 000
–
27
/
12,0
2 650
-10...+70
52 500 / 25 000
–
50
28
/
12,0
2 750
-40...+90
52 500 / 15 000
–
115
60
18
/
8,0
1 850
-10...+80
62 500 / 25 000
–
21,2
115
60
24
/
11,0
2 450
-10...+70
55 000 / 27 500
–
27,7
115
60
32
/
11,0
3 150
-10...+75
55 000 / 25 000
–
27,7
115
60
33
/
11,0
3 250
-40...+95
55 000 / 15 000
–
20
8550 TV
40
23,5
230
50
8556 TV
40
23,5
230
8830 TV
27
15,9
8800 TV
36
8500 TV
47
8506 TV
47
The air flow and noise level of fans without external housing depends on the installation conditions. The stated air
flow and noise has been measured with an orifice 76.5
mm Ø at a distance of approx. 17 mm from the mounting
bracket. Under exceptionally favourable mounting conditions, the air flow of fan series 8000 N is achievable. The
noise in the optimal operating range can only be measured
for these fans in a specific application.
Fan type
ACmaxx / i-maxx
15
50
Lead wires
8880 TV
8850 TV
325 mm long
AWG 18, TR 64
8550 TV
8500 TV
325 mm long
AWG 18, TR 64
8556 TV
8506 TV
325 mm long
AWG 18
3
8830 TV
8800 TV
37 +1
AC axial fans
50
230
AC centrifugal fans
230
18,2
10
R4
Accessories
14,1
31
Curve
24
8850 TV
Hours
101 + 0,2
8880 TV
3,7 + 0,15
dB(A)
0,3
Hz
ø75,8
V
325 +10
CFM
Type
at T max
Power input
/
Sound pressure level
Hours
Frequency
°C
Nominal voltage
RPM
Air flow
Watts
Air flow
/
m3/h
Nominal data
DC centrifugal fans
AC fans with external rotor shaded-pole motor. Impedance protected against overloading.
Impeller and mounting bracket of metal.
Air exhaust over mounting bracket. Direction of rotation clockwise, seen on rotor.
Electrical connection via 2 leads. Bared and tin-plated.
Mass: 370 g.
Please note our new ACmaxx series. With identical mounting dimensions and voltages, this
series achieves higher energy efficiency.
Sintec sleeve bearings
Ball bearings
–
–
–
–
–
–
76 Ø x 37 mm
DC fans - specials
Series 8000 TV
DC axial fans
AC axial fans
90°
HP
Û S
P
IP54
147
Representatives
47 m3/h
6 +1
max.
70 m3/h
max.
AC axial fans
Series 3900
Frequency
Sound pressure level
Sound power level
Sintec sleeve bearings
Ball bearings
Power input
Nominal speed
Temperature range
Service life L10
at 40 °C
CFM
V
Hz
dB(A)
Bel(A)
/
Watts
RPM
°C
Hours
3950 L
31
18,2
230
50
24
3,8
/
6,0
1 550
-10...+80
70 000 / 27 500
1
3956 L
31
18,2
230
50
24
3,8
/
6,0
1 550
-40...+80
70 000 / 27 500
1
3950 M
45
26,5
230
50
29
4,2
/
6,0
2 150
-10...+80
70 000 / 27 500
2
3956 M
45
26,5
230
50
29
4,2
/
6,0
2 150
-40...+80
70 000 / 27 500
2
3950
59
34,7
230
50
35
4,7
/
11,0
2 650
-20...+80
55 000 / 20 000
3
3956
59
34,7
230
50
35
4,7
/
11,0
2 650
-40...+80
55 000 / 20 000
3
3900 L
39
23,0
115
60
27
4,0
/
5,0
1 850
-10...+80
70 000 / 27 500
4
3906 L
39
23,0
115
60
27
4,0
/
5,0
1 850
-40...+80
70 000 / 27 500
4
3900 M
53
31,2
115
60
34
4,6
/
5,0
2 600
-10...+80
70 000 / 27 500
5
3906 M
53
31,2
115
60
34
4,6
/
5,0
2 600
-40...+80
70 000 / 27 500
5
3900
70
41,2
115
60
40
5,1
/
9,0
3 150
-20...+80
60 000 / 22 500
6
3906
70
41,2
115
60
40
5,1
/
9,0
3 150
-40...+80
60 000 / 22 500
6
Pa
[in H2O]
Type
60
16
40
0,15
50
0,20
3
15
2
0,10
30
14
20
1
0,05
10
0
10
10
20
20
30
30
40
50
50 Hz
148
HP
CFM
60
m³/h
60 Hz
Curve
Nominal voltage
m3/h
Nominal data
at T max
Air flow
AC fans with internal rotor shaded-pole motor. Impedance protected against overloading.
Metal fan housing, impeller of mineral-reinforced plastic PA.
Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor.
Electrical connection via 2 flat plugs 2.8 x 0.5 mm.
Fan housing with grounding lug for screw M4.
Mass: 280 g.
Please note our new ACmaxx series. With identical mounting dimensions and voltages, this
series achieves higher energy efficiency.
Air flow
–
–
–
–
–
–
–
92 x 92 x 25 mm
Hours
Information
Frequency
Sound pressure level
Sound power level
Sintec sleeve bearings
Ball bearings
Power input
Nominal speed
Temperature range
Service life L10
at 40 °C
m3/h
CFM
V
Hz
dB(A)
Bel(A)
/
Watts
RPM
°C
Hours
3850
49
28,8
230
50
24
3,7
/
9,0
1 750
-10...+75
60 000 / 27 500
1
3856
54
31,8
230
50
26
3,9
/
9,0
1 950
-40...+90
60 000 / 20 000
2
3550
67
39,4
230
50
32
4,4
/
8,5
2 300
-10...+80
60 000 / 25 000
3
3556
67
39,4
230
50
33
4,5
/
8,5
2 400
-40...+90
60 000 / 20 000
3
3650
75
44,1
230
50
36
4,8
/
12,0
2 650
-10...+55
52 500 / 37 500
4
3656
75
44,1
230
50
37
4,9
/
12,0
2 700
-40...+75
52 500 / 22 500
4
3800
54
31,8
115
60
26
3,9
/
8,0
1 900
-10...+80
62 500 / 25 000
5
3806
60
35,3
115
60
29
4,2
/
8,0
2 150
-40...+95
62 500 / 17 500
6
3500
73
43,0
115
60
35
4,6
/
8,0
2 500
-10...+80
62 500 / 25 000
7
3506
73
43,0
115
60
36
4,7
/
8,0
2 600
-40...+95
62 500 / 17 500
7
3600
89
52,4
115
60
41
5,1
/
11,0
3 100
-10...+65
55 000 / 30 000
8
3606
89
52,4
115
60
42
5,2
/
11,0
3 200
-40...+75
55 000 / 25 000
8
Lead wires
With sleeve bearings
310 mm long
AWG 18, TR 64
With ball bearings
310 mm long
AWG 18
AC centrifugal fans
Fan type
ACmaxx / i-maxx
Hours
[in H2O]
Pa
60
8
0,25
70
Curve
Nominal voltage
Type
Nominal data
at T max
Air flow
DC centrifugal fans
AC fans with external rotor shaded-pole motor. Impedance protected against overloading.
Metal fan housing and impeller.
Air exhaust over struts. Rotational direction CW looking at rotor.
Electrical connection via 2 leads. Bared and tin-plated.
Fan housing with grounding lug and screw M4 x 8 (TORX).
Mass: 420 g.
Please note our new ACmaxx series. With identical mounting dimensions and voltages, this
series achieves higher energy efficiency.
Air flow
–
–
–
–
–
–
–
92 x 92 x 38 mm
DC fans - specials
Series 3000
DC axial fans
AC axial fans
AC axial fans
89 m3/h
max.
7
2
6
Accessories
0,15
3
0,10
30
20
5
0,05
10
1
0
10
10
20
30
20
30
40
50
40
60
50 Hz
70
CFM
m³/h
60 Hz
HP
Û S
P
IP54
149
Representatives
40
0,2
4
50
135 m3/h
max.
AC axial fans
Series 9900
119 x 119 x 25 mm
Nominal voltage
Frequency
Sound pressure level
Sound power level
Sintec sleeve bearings
Ball bearings
Power input
Nominal speed
Temperature range
Service life L10
at 40 °C
CFM
V
Hz
dB(A)
Bel(A)
/
Watts
RPM
°C
Hours
9956 L
84
49,4
230
50
29
4,4
/
9,5
1850
-40...+80
57 500 / 22 500
1
9956 M
104
61,2
230
50
35
4,7
/
10,0
2250
-40...+80
57 500 / 22 500
2
9950
117
68,9
230
50
37
5,0
/
14,0
2450
-20...+70
47 500 / 22 500
3
9956
117
68,9
230
50
37
5,0
/
14,0
2450
-40...+70
47 500 / 22 500
3
9906 L
100
58,9
115
60
34
4,6
/
8,0
2100
-40...+80
62 500 / 25 000
4
9906 M
111
65,3
115
60
37
5,0
/
8,0
2450
-40...+80
62 500 / 25 000
5
9900
135
79,5
115
60
42
5,4
/
12,0
2850
-20...+70
52 500 / 25 000
6
9906
135
79,5
115
60
42
5,4
/
12,0
2850
-40...+70
52 500 / 25 000
6
Pa
3
0,15
40
[in H2O]
Type
30
6
0,10
2
4
1
0,05
20
10
5
0
15
20
30
40
45
60
80
60
CFM
100
m³/h
50 Hz
150
HP
60 Hz
Curve
Air flow
m3/h
Nominal data
at T max
Air flow
– AC fans with external rotor shaded-pole motor.
Protected against overloading by thermal cut-out.
– Metal fan housing and impeller.
– Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor.
– Electrical connection via 2 flat plugs 2.8 x 0.5 mm.
– Fan housing with grounding lug and screw M4 x 8 (TORX).
– Mass: 320 g.
– Please note our new ACmaxx series. With identical mounting dimensions and voltages, this
series achieves higher energy efficiency.
Hours
230
50
25
4,0
/
230
50
32
4,4
/
230
50
41
5,2
85,3
230
50
44
94,2
230
50
46
160
94,2
230
50
4840 N
85
50,0
115
4800 N*
97
57,1
115
4530 N*
151
88,9
115
4500 N*
169
99,5
115
4600 N
180
105,9
4606 N
180
105,9
47,1
100
58,9
4580 N*
123
72,4
4550 N*
145
4650 N
160
4656 N
°C
Hours
11,0
1 550
-10...+70
55 000 / 27 500
1
10,0
1 800
-10...+70
57 500 / 27 500
2
/
18,0
2 350
-10...+55
40 000 / 27 500
3
5,4
/
16,5
2 550
-10...+55
42 500 / 30 000
4
5,4
/
19,0
2 650
-10...+55
37 500 / 27 500
5
47
5,5
/
19,0
2 650
-40...+85
37 500 / 15 000
5
60
26
4,1
/
10,0
1 650
-10...+75
57 500 / 25 000
6
60
32
4,3
/
9,0
1 750
-10...+75
60 000 / 27 500
7
60
45
5,4
/
16,0
2 700
-10...+65
42 500 / 25 000
8
60
48
5,7
/
15,0
3 000
-10...+65
47 500 / 25 000
9
115
60
50
5,7
/
18,0
3 100
-10...+60
40 000 / 25 000
10
115
60
51
5,8
/
18,0
3 100
-40...+90
40 000 / 15 000
10
* Fan with 3 blades.
AC centrifugal fans
Pa
[in H2O]
230 V and 115 V versions are rated for both 50 Hz and 60 Hz operation.
For 60 Hz data, please refer to the corresponding 115 V 60 Hz model,
for 50 Hz data please refer to the corresponding 230 V 50 Hz model.
Hours
10
0,3
80
9
0,2
[in H2O]
8
40
0,1
5
7
20
0,3
Pa
60
80
DC axial fans
Information
RPM
Curve
80
4850 N*
Watts
at T max
4890 N
Service life L10
at 40 °C
Sintec sleeve bearings
Ball bearings
/
Temperature range
Sound power level
Bel(A)
CFM
Type
Nominal speed
Sound pressure level
dB(A)
m3/h
Nominal data
Power input
Frequency
Hz
Air flow
V
Air flow
Nominal voltage
– AC fans with external rotor shaded-pole motor. Impedance protected against overloading.
– Metal fan housing and impeller
– Air intake over struts. Direction of rotation clockwise, seen on rotor.
Types 4890 N and 4840 N air exhaust over struts.
– Electrical connection via 2 flat plugs 3.0 x 0.5 mm.
– Impeller with 3 or 5 blades, see note for fan type.
– Optionally available: Models with reinforced flanges and single leads.
– Fan housing with grounding lug for screw M 4 and UNC.
– Mass: 550 g.
– Please note our new ACmaxx series. With identical mounting dimensions and voltages, this
series achieves higher energy efficiency.
DC centrifugal fans
119 x 119 x 38 mm
DC fans - specials
Series 4000 N
ACmaxx / i-maxx
AC axial fans
AC axial fans
180 m3/h
max.
60
4
0
20
0,2
25
40
50
75
60
100
80
125
Accessories
6
CFM
m³/h
60 Hz
40
3
0,1
2
20
1
20
25
40
50
75
60
100
80
125
CFM
m³/h
50 Hz
HP
Û S
P
IP54
151
Representatives
0
180 m3/h
AC axial fans
Series 4000 Z
Sound power level
Sintec sleeve bearings
Ball bearings
V
Hz
dB(A)
Bel(A)
/
4850 Z
100
58,9
230
50
26
4,0
/
4856 Z
100
58,9
230
50
26
4,0
/
4580 Z
115
67,7
230
50
30
4,3
4586 Z
115
67,7
230
50
30
4650 Z
160
94,2
230
50
40
4656 Z
160
94,2
230
50
4800 Z
105
61,6
115
4806 Z
105
61,6
115
4530 Z
120
70,6
4536 Z
120
70,6
4600 Z
180
4606 Z
180
40
13,0
1 700
-10...+65
50 000 / 27 500
1
13,0
1 700
-40...+75
50 000 / 20 000
1
/
13,0
1 900
-10...+65
50 000 / 27 500
2
4,3
/
13,0
1 900
-40...+75
50 000 / 20 000
2
5,3
/
19,0
2 650
-10...+50
37 500 / 30 000
3
40
5,3
/
19,0
2 650
-40...+75
37 500 / 17 500
3
60
28
4,1
/
12,0
1 800
-10...+70
52 500 / 25 000
4
60
28
4,1
/
12,0
1 800
-40...+75
52 500 / 17 500
4
115
60
32
4,4
/
12,0
2 000
-10...+70
52 500 / 25 000
5
115
60
32
4,4
/
12,0
2 000
-40...+75
52 500 / 17 500
5
105,9
115
60
45
5,6
/
18,0
3 100
-10...+60
40 000 / 25 000
6
105,9
115
60
45
5,6
/
18,0
3 100
-40...+85
40 000 / 15 000
6
2
0,10
5
20
1
0,05
4
0
20
25
40
50
75
60
100
80
125
100
150
50 Hz
152
HP
CFM
m³/h
60 Hz
Û S
P
IP54
Curve
Hours
6
3
30
10
°C
[in H2O]
0,25
Pa
50
RPM
0,20
60
Watts
0,15
70
Service life L10
at 40 °C
Sound pressure level
CFM
Temperature range
Frequency
m3/h
Nominal speed
Nominal voltage
Type
Nominal data
Power input
Air flow
AC fans with external rotor shaded-pole motor. Impedance protected against overloading.
Metal fan housing and impeller.
Air exhaust over struts. Direction of rotation clockwise, seen on rotor.
Electrical connection via 2 flat plugs 2.8 x 0.5 mm.
Optionally available: Models with reinforced flanges and single leads.
Fan housing with grounding lug and screw M4 x 8 (TORX).
Mass: 540 g.
Please note our new ACmaxx series. With identical mounting dimensions and voltages, this
series achieves higher energy efficiency.
Air flow
–
–
–
–
–
–
–
–
119 x 119 x 38 mm
at T max
max.
Hours
4650 TA
138
81,2
230
50
41
/
4656 TA
138
81,2
230
50
42
/
4600 TA
147
86,5
115
60
43
4606 TA
147
86,5
115
60
44
Information
DC centrifugal fans
/
RPM
°C
Hours
19,0
2 550
-10...+45
37 500 / 32 500
–
19,0
2 550
-40...+75
37 500 / 17 500
–
/
18,0
2 900
-10...+50
40 000 / 32 500
–
/
18,0
2 900
-40...+80
40 000 / 17 500
–
The air flow and noise level of fans without external housing depends on the installation conditions. The stated
air flow and noise has been measured with an orifice
109 mm Ø at a distance of approx. 17 mm from the
mounting bracket. Under exceptionally favourable
mounting conditions, the air flow of fan series 4600 N
is achievable. The noise in the optimal operating range
can only be measured for these fans in a specific application.
Fan type
Curve
at T max
Watts
Hours
Lead wires
4600 TA
AWG 22, TR 32
4656 TA
4606 TA
AWG 18
R4
16
37 +1
AC centrifugal fans
AC axial fans
4650 TA
DC fans - specials
dB(A)
ACmaxx / i-maxx
Hz
3
0,5 +0,3
375
+10
6 +1
148,2
+ 0,2
Accessories
Sintec sleeve bearings
Ball bearings
V
Service life L10
at 40 °C
Sound pressure level
CFM
Temperature range
Frequency
m3/h
Nominal speed
Nominal voltage
Type
Nominal data
Power input
Air flow
AC fans with external rotor shaded-pole motor. Impedance protected against overloading.
Impeller and mounting bracket of metal.
Air intake over mounting bracket. Direction of rotation clockwise, seen on rotor.
Electrical connection via 2 leads. Bared and tin-plated.
Mass: 430 g.
Please note our new ACmaxx series. With identical mounting dimensions and voltages, this
series achieves higher energy efficiency.
Air flow
–
–
–
–
–
–
113 Ø x 37 mm
90°
HP
Û S
P
IP54
153
Representatives
Series 4600 TA
DC axial fans
AC axial fans
ø112,5 + 0,3
147 m3/h
4,3 + 0,15
max.
AC axial fans
Series 4600 TZ
Sintec sleeve bearings
Ball bearings
V
Hz
dB(A)
/
4650 TZ
125
73,6
230
50
42
/
4656 TZ
125
73,6
230
50
42
/
4600 TZ
140
82,4
115
60
45
4606 TZ
140
82,4
115
60
45
RPM
°C
Hours
19,0
2 600
-10...+50
37 500 / 37 500
–
19,0
2 600
-40...+65
37 500 / 20 000
–
/
18,0
2 950
-10...+50
40 000 / 32 500
–
/
18,0
2 950
-40...+75
40 000 / 17 500
–
The air flow and noise level of fans without external
housing depends on the installation conditions. The stated air flow and noise has been measured with an orifice 109 mm Ø at a distance of approx. 17 mm from the
mounting bracket. Under exceptionally favourable
mounting conditions, the air flow of fan series 4000 Z
is achievable. The noise in the optimal operating range
can only be measured for these fans in a specific application.
Fan type
4600 TZ
AWG 22, TR 32
4656 TZ
4606 TZ
AWG 18
37 + 1
3
0,5 + 0,3
6 +1
148,2 + 0,2
ø108 + 0,3
R4
16
Hours
Lead wires
4650 TZ
90°
154
HP
Û S
P
IP54
Curve
Watts
at T max
Service life L10
at 40 °C
Sound pressure level
CFM
Temperature range
Frequency
m3/h
Nominal speed
Nominal voltage
Type
Nominal data
Power input
Air flow
AC fans with external rotor shaded-pole motor. Impedance protected against overloading.
Impeller and mounting bracket of metal.
Air exhaust over mounting bracket. Direction of rotation clockwise, seen on rotor.
Electrical connection via 2 leads. Bared and tin-plated.
Mass: 430 g.
Please note our new ACmaxx series. With identical mounting dimensions and voltages, this
series achieves higher energy efficiency.
Air flow
–
–
–
–
–
–
108 Ø x 37 mm
375 +10
140 m3/h
4,3 + 0,15
max.
Bel(A)
/
150
88,3
230
50
37
4,9
/
180
105,9
230
50
43
5,4
/
5958
180
105,9
230
50
44
5,5
5938
162
95,3
115
60
40
5900
206
121,2
115
60
46
5908
206
121,2
115
60
47
5950
Information
RPM
°C
Hours
13,0
2 250
-30...+55
35 000 / 20 000
1
18,0
2 700
-20...+50
40 000 / 32 500
3
/
18,0
2 750
-30...+60
40 000 / 25 000
3
4,9
/
12,0
2 500
-30...+55
35 000 / 20 000
2
5,7
/
17,0
3 050
-20...+55
42 500 / 30 000
4
5,8
/
17,0
3 100
-30...+75
42 500 / 20 000
4
Curve
Watts
Hours
AC centrifugal fans
4
40
0,15
50
0,20
1
Accessories
Pa
60
3
0,25
70
[in H2O]
AC axial fans
5988
DC centrifugal fans
Sintec sleeve bearings
Ball bearings
dB(A)
ACmaxx / i-maxx
Sound power level
Hz
Service life L10
at 40 °C
Sound pressure level
V
Temperature range
Frequency
CFM
Type
Nominal speed
Nominal voltage
m3/h
Nominal data
Power input
Air flow
AC fans with internal rotor shaded-pole motor. Impedance protected against overloading.
Metal fan housing and impeller of fibreglass-reinforced plastic PA.
Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor.
Electrical connection via 2 flat plugs 2.8 x 0.8 mm.
Fan housing with grounding lug and screw M4 x 6.
Mass: 570 g.
Please note our new ACmaxx series. With identical mounting dimensions and voltages, this
series achieves higher energy efficiency.
Air flow
–
–
–
–
–
–
–
127 x 127 x 38 mm
DC fans - specials
Series 5900
DC axial fans
AC axial fans
at T max
206 m3/h
max.
2
0,10
30
0
20
25
40
50
75
60
100
80
125
100
150
50 Hz
CFM
m³/h
60 Hz
HP
155
Representatives
10
0,05
20
270 m3/h
max.
AC axial fans
Series 5600
135 x 135 x 38 mm
Pa
[in H2O]
100
138,3
230
50
46
5,9
/
158,9
115
60
50
6,2
/
2
1
0,2
60
20
0,1
40
0
40
50
80
100
150
120
200
50 Hz
156
HP
CFM
250
m³/h
60 Hz
Û S
P
IP54
Watts
RPM
°C
Hours
30,0
2 700
-35...+70
45 000 / 20 000
1
26,0
3 100
-35...+80
47 500 / 20 000
2
Curve
/
at T max
Bel(A)
Service life L10
at 40 °C
dB(A)
Temperature range
Hz
Nominal speed
V
0,3
80
CFM
Power input
270
Sintec sleeve bearings
Ball bearings
5606 S
Sound power level
235
Sound pressure level
5656 S
Frequency
m3/h
Nominal voltage
Type
Nominal data
Air flow
Air flow
– AC fans with external rotor shaded-pole motor.
Protected against overloading by thermal cut-out.
– Metal fan housing and impeller.
– Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor.
– Electrical connection via 2 flat plugs 2.8 x 0.5 mm.
– Fan housing with grounding lug and screw M4 x 8 (TORX).
– Mass: 800 g.
– Please note our new ACmaxx series. With identical mounting dimensions and voltages, this
series achieves higher energy efficiency.
Hours
Information
Series 7000
150 x 172 x 38 mm
230
50
51
6,4
/
223,6
115
60
56
6,8
/
DC centrifugal fans
188,3
Watts
RPM
°C
Hours
27,0
2 800
-25...+55
60 000 / 32 000
1
28,0
3 350
-25...+65
55 000 / 18 000
2
Hours
ACmaxx / i-maxx
/
Curve
Bel(A)
at T max
dB(A)
Service life L10
at 40 °C
Hz
Temperature range
V
Nominal speed
CFM
Power input
380
Sintec sleeve bearings
Ball bearings
7006 ES
Sound power level
320
Sound pressure level
7056 ES
Frequency
m3/h
Nominal voltage
Type
Nominal data
Air flow
Air flow
– AC fans with external rotor capacitor motor. Protected against
overloading by integrated thermal cut-out.
– Metal fan housing and impeller.
– Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor.
– Electrical connection via 2 flat plugs 2.8 x 0.5 mm.
– Fan housing with grounding lug and screw M4 x 6.
– Mass: 900 g.
– Please note our new ACmaxx series. With identical mounting dimensions and voltages, this
series achieves higher energy efficiency.
DC axial fans
AC axial fans
DC fans - specials
380 m3/h
max.
1
AC centrifugal fans
Pa
[in H2O]
2
0,6
AC axial fans
Minimum ambient temperature -15 °C.
Accessories
0,2
80
0,3
0,4
120
0,5
160
0,1
40
40
50
80
100
150
120
200
160
250
200
300
50 Hz
CFM
m³/h
60 Hz
157
Representatives
0
380 m3/h
max.
AC axial fans
Series 7800
150 Ø x 55 mm
Sintec sleeve bearings
Ball bearings
Bel(A)
/
191,3
230
50
49
6,0
/
191,3
230
50
49
6,0
/
380
223,7
115
60
53
6,4
380
223,7
115
60
53
6,4
325
7805 ES
7806 ES
RPM
°C
Hours
45,0
2 800
-25...+50
60 000 / 47 000
1
45,0
2 800
-25...+70
60 000 / 23 000
1
/
38,0
3 250
-25...+70
60 000 / 47 000
2
/
38,0
3 250
-25...+90
60 000 / 18 000
2
80
0,5
Pa
100
0,4
120
2
0,3
140
[in H2O]
Minimum ambient temperature -15 °C, admissible for a short time at -30 °C; without condensation.
1
0,2
60
20
0,1
40
0
40
50
80
100
150
120
200
160
250
200
300
50 Hz
158
CFM
m³/h
60 Hz
Curve
325
7856 ES
Watts
at T max
7855 ES
Service life L10
at 40 °C
Sound power level
dB(A)
Temperature range
Sound pressure level
Hz
m3/h
Nominal speed
Frequency
V
Type
Nominal data
Power input
Nominal voltage
CFM
Air flow
Air flow
– AC fans with external rotor shaded-pole motor. Protected against
overloading by integrated thermal cut-out.
– Metal fan housing and impeller.
– Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor.
– Electrical connection via 2 leads. Bared and tin-plated.
– Fan housing with grounding lug and screw M4 x 6.
– Mass: 1.1 kg.
– Please note our new ACmaxx series. With identical mounting dimensions and voltages, this
series achieves higher energy efficiency.
Hours
Information
Series 7400
150 Ø x 55 mm
230
50
60
6,8
/
250,1
115
60
62
6,9
/
DC centrifugal fans
223,6
Watts
RPM
°C
Hours
47,0
2 700
-25...+50
63 000 / 50 000
1
46,0
3 050
-25...+70
50 000 / 24 000
2
Hours
ACmaxx / i-maxx
/
Curve
Curve
Bel(A)
at T max
dB(A)
Service life L10
at 40 °C
Hz
Temperature range
V
Nominal speed
CFM
Power input
425
Sintec sleeve bearings
Ball bearings
7400 ES
Sound power level
380
Sound pressure level
7450 ES
Frequency
m3/h
Nominal voltage
Type
Nominal data
Air flow
Air flow
– AC fans with external rotor shaded-pole motor. Protected against
overloading by integrated thermal cut-out.
– Metal fan housing and impeller.
– Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor.
– Electrical connection via 2 leads. Strand ends with brass lead tips.
– Fan housing with grounding lug and screw M4 x 6.
– Mass: 1.1 kg.
– Please note our new ACmaxx series. With identical mounting dimensions and voltages, this
series achieves higher energy efficiency.
DC axial fans
AC axial fans
DC fans - specials
425 m3/h
max.
AC centrifugal fans
[in H2O]
Pa
AC axial fans
Minimum ambient temperature -15 °C, admissible for a short time at -30 °C; without condensation.
120
2
Accessories
0,4
0,2
60
20
0,1
40
0
40
80
100
120
200
160
200
240
400
300
50 Hz
CFM
m³/h
60 Hz
159
Representatives
80
1
0,3
100
500 m3/h
max.
AC axial fans
Series 6000
172 Ø x 51 mm
Sintec sleeve bearings
Ball bearings
dB(A)
Bel(A)
/
220,7
230
50
55
5,9
/
247,2
230
50
54
6,3
/
440
259,0
115
60
60
6,4
500
284,3
115
60
58
6,7
6058 ES
375
6078 ES
420
6008 ES
6028 ES
RPM
°C
Hours
24,0
2 800
-25...+70
62 000 / 31 000
1
26,0
2 800
-25...+60
62 000 / 39 000
2
/
26,0
3 300
-25...+70
57 000 / 28 000
3
/
29,0
3 300
-25...+75
57 000 / 22 000
4
0,6
Pa
0,2
80
0,3
0,4
120
0 ,5
160
[in H2O]
Minimum ambient temperature -15 °C, admissible for a short time at -30 °C; without condensation.
0,1
40
1
0
40
80
100
120
200
160
200
400
300
50 Hz
160
2
240
3
4
CFM
m³/h
60 Hz
Curve
Watts
at T max
Service life L10
at 40 °C
Sound power level
Hz
m3/h
Temperature range
Sound pressure level
V
Type
Nominal speed
Frequency
Nominal data
Power input
Nominal voltage
CFM
Air flow
Air flow
– AC fans with external rotor capacitor motor. Protected against
overloading by integrated thermal cut-out.
– Metal fan housing and impeller.
– Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor.
– Electrical connection via 2 flat plugs 2.8 x 0.5 mm.
– Fan housing with grounding lug and screw M4 x 6.
– Mass: 1.0 kg.
– Please note our new ACmaxx series. With identical mounting dimensions and voltages, this
series achieves higher energy efficiency.
Hours
Information
W** 200
225 x 225 x 80 mm
Sound power level
Sleeve bearings
Ball bearings
Power input
Nominal speed
Temperature range
Service life L10
at 40 °C
Hz
dB(A)
Bel(A)
/
Watts
RPM
°C
Hours
606,2
115
60
61
6,7
/
80,0
2800
-25...+65
60 000 / 58 000
2
880
517,9
230
50
58
6,6
/
64,0
2550
-25...+60
63 000 / 60 000
2
450
264,9
230
50
40
4,7
/
30,0
1370
-25...+70
85 000 / 80 000
1
1030
W2E200-HK38-01*
W4S200-HK04-01**
[in H2O]
0,20
AC axial fans
30
0,1
1
0
50
100
100
150
200
200
300
250
400
CFM
AC centrifugal fans
10
0,05
20
m³/h
0,4
2
Accessories
Pa
80
0,3
100
[in H2O]
50 Hz
0,2
60
20
0,1
40
0
100
200
200
300
400
400
600
500
CFM
800
m³/h
50 Hz
60 Hz
161
Representatives
40
0,15
50
Hours
ACmaxx / i-maxx
W2E200-HK86-01*
Pa
m3/h
DC fans - specials
Sound pressure level
V
Type
Curve
Frequency
Nominal data
at T max
Nominal voltage
CFM
Air flow
Air flow
– External-rotor single-phase motor.* / External rotor shaded-pole motor.**
– Motor protection: TOP wired internally.
– Material: Wall ring die-cast aluminium, seven blades of sheet steel. Blades and rotor
coated in black.
– Direction of air flow “V”, air exhaust over struts. Direction of rotation: counter-clockwise,
seen on rotor.
– Electrical connection: Terminal strip (operating capacitor connected).
– Continuous operation (S1).
– Insulation class: “F”
– Mass: 2 kg.
– Please note our new ACmaxx series. With identical mounting dimensions and voltages,
this series achieves higher energy efficiency.
DC axial fans
AC axial fans
DC centrifugal fans
1030 m3/h
max.
max.
1865 m3/h
AC axial fans
W2E 250 280 x 280 x 80 mm
Sound pressure level
Sound power level
Sleeve bearings
Ball bearings
Power input
Nominal speed
Temperature range
Service life L10
at 40 °C
V
Hz
dB(A)
Bel(A)
/
Watts
RPM
°C
Hours
230
50
66
7,2
/
127,0
2 550
-25...+60
1865 1077,1
Pa
W2E 250-HL06-01
[in H2O]
m3/h
80
0,4
100
32
0,3
120
0,5
140
0,2
60
20
0,1
40
0
200
400
400
800
600
1200
800
CFM
1600
50 Hz
162
m³/h
60 Hz
Curve
Frequency
CFM
Type
at T max
Nominal voltage
Nominal data
Air flow
Air flow
– External-rotor single-phase motor.
– Motor protection: TOP wired internally.
– Material: Wall ring die-cast aluminium, seven blades of sheet steel. Blades and rotor coated in
black.
– Direction of air flow “V”, air exhaust over struts. Direction of rotation: counter-clockwise, seen
on rotor.
– Electrical connection: Terminal strips (operating capacitor connected).
– Continuous operation (S1).
– Insulation class: “F”
– Mass: 2 kg.
– Please note our new ACmaxx series. With identical mounting dimensions and voltages, this
series achieves higher energy efficiency.
Hours
63 000 / 70 000
3
Accessories
AC centrifugal fans
AC axial fans
ACmaxx / i-maxx
DC fans - specials
165
AC centrifugal fans
166
163
DC centrifugal fans
AC centrifugal fan overview
Representatives
DC axial fans
Information
AC centrifugal fans
AC fans
Technical information
Product line
The renowned ebm-papst AC fans are used
when DC voltage is not available. The AC range
of fans is based on experience gained from
decades of development activity, millions of
units in series production and competence in
innovation of a world-wide technological leader.
A wide range of fans for AC operation is presented in this catalogue. In addition to complete
device fans, you will also find fans without
external housing, providing a particularly economical advantage when the air duct can be
integrated in the respective device.
Variety of sizes
AC fans are available in a variety of sizes with
either air exhaust or air intake over struts.
Silent running models with sleeve bearings or
for extreme ambient conditions; fans with ball
bearings are available with plug connection or
external leads.
Shaded-pole or capacitor motors
Fan drives by shaded-pole or capacitor motors,
most of which incorporate the world-famous
ebm-papst external rotor principle: The fan
blades are directly attached to the external rotor
of the external rotor motor, thus combining both
high performance and profitability.
Flat built AC fans
ebm-papst also has particularly flat built AC
fans with internal rotor motor. Their advantage:
quick start to full speed. A plastic impeller and
the both smaller and lighter internal rotor motor
lead to a lower moment of inertia.
164
Bearings
AC fans with sleeve bearings are powered by
Class E insulated motors. Fans with ball
bearings are equipped with Class B, E or F
insulated motors.
Protection class
All ebm-papst fans conform to the requirements
of IP 20. Fans conforming to IP 54 and special
types of protection class are also available.
AC voltage
The line of AC fans for Euro voltage according
to IEC 60038 (230 V + 6 %, -10 %) is basically
also available for 115 V.
Frequencies
AC fans can be operated at frequencies of 50
Hz or 60 Hz. However, their technical data then
change accordingly.
Capacitor
Fans driven by capacitor external motors
provide particularly high operating efficiency.
Generally, the required operating capacitor is
already integrated in the fan housing.
Overloading
Almost all AC fans are protected against overloading (e.g. due to locked rotor) the drive
motors are either impedance protected (marked
“Impedance protected”, and/or “Z.P.”) or are
equipped with a thermal switch (marked
“Thermally protected” or “Th.P.”). The model
designation of these fans ends with “S”.
Information
Centrifugal fans for AC operation
10
20
30
50
40
60
70 80 90 100
200
300
400
500 600 700 800 900 1000
2000
3000
121 x 37
RL 90
40...42
166
135 x 38
RG 90
47...54
167
180 x 40
RG 125
86...94
168
220 x 56
RG 160
202...223
169
Ø
138 x 40
RER 125
104...115
170
Ø
176 x 54
RER 160
234...274
171
–
RG 90
135 x 135 x 38
yes
/
–
RG 125
180 x 180 x 40
yes
–
RG 160
220 x 220 x 56
yes
–
RER 125
138 Ø x 40
yes
–
RER 160
176 Ø x 54
yes
–
– not yet available
prot
OPTIONAL
Sleeve bearings
•
•
•
•
•
•
P.
•
•
•
•
•
•
•
•
•
•
•
•
and speeds, and not in all combinations.
166
The special versions are designed for specific customers and projects
167
and are not usually available off the shelf.
AC axial fans
/
168
169
Speed signal
170
The fan uses a separate wire to output information about its
171
speed, and thus about the speed of the rotor. For technical
Ball bearings
details, please refer to page 110.
HP
Protection against moisture
Protection for the fan's electronics against moisture and
AC centrifugal fans
yes
condensation. For technical details, please refer to page 123.
Û
IP54
IP 54
Protection of motor and PCB board against splashed water
and humidity. For technical details, please refer to page 123.
SP
Protection against salt spray fog
Accessories
121 x 121 x 37
sible special versions in the fan line presented.
Protection of fan against the damaging effects of salt spray
fog. For technical details, please refer to page 123.
165
Representatives
• availabe
mm
RL 90
On the pages of the catalogue and on the following overview pages, the
Please note that these special versions are not possible for all voltages
Centrifugal fans
Series
Information on pictograms
pictograms illustrated below provide information about technically pos-
Page
Salt
spra
y fog
ectio
prot
54
idity
= IP
IP >
nsor
Hum
d se
Spee
VDE
Dim
, UL,
ensio
n
CSA
Sinte
c
ball sleeve b
bear earing
ings
s/
n
ectio
n
Overview of technically feasible designs
ACmaxx / i-maxx
DC fans - specials
DC axial fans
m3/h
mm
DC centrifugal fans
Page
Air flow
Series
Dimension
Overview of air prformance
42 m3/h
max.
AC centrifugal fans
Series RL 90
121 x 121 x 37 mm
Nominal voltage
Frequency
Sound power level
Sintec sleeve bearings
Ball bearings
Power input
Nominal speed
Temperature range
Service life L10
at 40 °C
CFM
V
Hz
Bel(A)
/
Watts
RPM
°C
Hours
RL 90-18/50
40
23,5
230
50
5,6
/
20,0
2 450
-10...+50
37 500 / 30 000
1
RL 90-18/56
40
23,5
230
50
5,6
/
20,0
2 450
-30...+70
37 500 / 20 000
1
RL 90-18/00
42
24,7
115
60
6,0
/
19,5
2 550
-10...+60
37 500 / 25 000
2
RL 90-18/06
42
24,7
115
60
6,0
/
19,5
2 550
-30...+85
37 500 / 15 000
2
Type
Pa
[in H2O]
Fan type
2
100
0,4
120
0,3
1
80
0,2
60
20
0,1
40
0
4
5
8
10
12
15
20
16
25
20
30
50 Hz
166
HP
CFM
m³/h
60 Hz
Û S
P
IP54
Curve
Air flow
m3/h
Nominal data
at T max
Air flow
– AC centrifugal fan with external rotor shaded-pole motor. Impedance protected
against overloading.
– Spiral housing and impeller of fibreglass-reinforced plastic.
Housing base of galvanised steel plate. Housing base with flat plug 6.3 x 0.8 mm for
protective earth.
– Direction of air flow radial, through housing port. Direction of rotation clockwise, seen on
rotor.
– Electrical connection via 2 leads. Bared and tin-plated.
– Mass: 680 g.
Hours
Lead wires
RL 90-18/50
RL 90-18/00
AWG 18, TR 32
RL 90-18/56
RL 90-18/06
AWG 22
Information
135 x 135 x 38 mm
Type
Type
dB(A)
Bel(A) Bel
/ /
Watts
Watts
RPM
RPM
Curve
DC centrifugal fans
°C °C
at T max
Service life L10
at 40 °C
Temperature range
Nominal speed
Power input
Sintec sleeve bearings
Ball bearings
Sound power level
Frequency
Hz Hz
Nominal data
Air flow
3/s V DCV
m3m
/h3/h10-3 m
CFM
Air flow
Nominal voltage
– AC centrifugal fan with external rotor shaded-pole motor. Impedance protected
against overloading.
– Spiral housing and impeller of fibreglass-reinforced plastic.
Housing base of galvanised steel plate.
– Direction of air flow radial, through housing port. Direction of rotation clockwise, seen on
rotor.
– Electrical connection via 2 leads AWG 22. Bared and tin-plated.
– Mass: 560 g.
Hours
Hours Hours
Hours
54
31,8
230
50
5,8
/
22,0
2 200
-30...+60
35 000 / 20 000
1
RG 90-18/56
54
31,8
230
50
5,8
/
22,0
2 200
-30...+60
35 000 / 20 000
1
RG 90-18/00
47
27,7
115
60
6,2
/
22,0
1 900
-30...+65
35 000 / 20 000
2
RG 90-18/06
47
27,7
115
60
6,2
/
22,0
1 900
-30...+65
35 000 / 20 000
2
100
AC centrifugal fans
2
0,4
120
0,3
Accessories
1
80
0,2
60
20
0,1
40
0
5
10
10
15
20
20
30
25
40
50 Hz
30
50
CFM
m³/h
60 Hz
HP
Û S
P
IP54
167
Representatives
Pa
[in H2O]
AC axial fans
RG 90-18/50
DC fans - specials
Series RG 90
DC axial fans
AC centrifugal fans
ACmaxx / i-maxx
54 m3/h
max.
94 m3/h
max.
AC centrifugal fans
Series RG 125
180 x 180 x 40 mm
Nominal voltage
Frequency
Sound power level
Sintec sleeve bearings
Ball bearings
Power input
Nominal speed
Temperature range
Service life L10
at 40 °C
CFM
V
Hz
Bel(A)
/
Watts
RPM
°C
Hours
RG 125-19/56
86
50,6
230
50
5,8
/
20,0
2 550
-30...+70
37 500 / 20 000
1
RG 125-19/06
94
55,3
115
60
6,0
/
19,0
2 750
-30...+80
40 000 / 15 000
2
Pa
[in H2O]
Type
2
200
1
0,4
0,6
100
50
0,2
150
0
10
20
20
30
40
40
50 Hz
168
HP
50
80
60
CFM
m³/h
60 Hz
Û S
P
IP54
Curve
Air flow
m3/h
Nominal data
at T max
Air flow
– AC centrifugal fan with external rotor shaded-pole motor. Impedance protected
against overloading.
– Spiral housing and impeller of fibreglass-reinforced plastic.
Housing base of galvanised steel plate.
– Direction of air flow radial, through housing port. Direction of rotation clockwise, seen on
rotor.
– Electrical connection via 2 leads AWG 22. Bared and tin-plated.
– Mass: 850 g.
Hours
Information
Series RG 160
220 x 220 x 56 mm
TypType
dB(A)
Bel(A) Bel
/ /
Watts
Watts
RPM
RPM
Curve
DC centrifugal fans
°C °C
at T max
Service life L10
at 40 °C
Temperature range
Nominal speed
Power input
Sintec sleeve bearings
Ball bearings
Sound power level
Frequency
Hz Hz
Nominal data
Air flow
3/s V DCV
m3m
/h3/h10-3 m
CFM
Air flow
Nominal voltage
– AC centrifugal fan with external rotor shaded-pole motor. Thermal contactor as protection
against thermal overloading.
– Spiral housing and impeller of fibreglass-reinforced plastic.
Housing base of galvanised steel plate.
– Direction of air flow radial, through housing port. Direction of rotation counter-clockwise,
seen on rotor.
– Electrical connection via leads AWG 18. Bared and tin-plated.
– Mass: 1.7 kg.
DC axial fans
AC centrifugal fans
Hours
Hours Hours
Hours
202
118,9
230
50
6,6
/
47,0
2 750
-30...+70
30 000 / 15 000
1
RG 160-28/06S
223
131,3
115
60
6,9
/
50,0
3 050
-30...+80
27 500 / 12 500
2
AC centrifugal fans
[in H2O]
Pa
AC axial fans
ACmaxx / i-maxx
RG 160-28/56S
DC fans - specials
223 m3/h
max.
2
400
0
20
40
50
60
100
80
100
120
200
150
50 Hz
CFM
m³/h
60 Hz
HP
Û S
P
IP54
169
Representatives
0,8
100
Accessories
1
1,2
200
0,4
300
115 m3/h
max.
AC centrifugal fans
Series RER 125
138 Ø x 40 mm
Sound power level
Sintec sleeve bearings
Ball bearings
Power input
Nominal speed
Temperature range
Service life L10
at 40 °C
CFM
V
Hz
Bel(A)
/
Watts
RPM
°C
Hours
RER 125-19/56
104
61,2
230
50
6,2
/
19,0
2 600
-30...+60
37 500 / 22 500
1
RER 125-19/06
115
67,7
115
60
6,5
/
18,0
2 850
-30...+70
40 000 / 20 000
2
Pa
[in H2O]
The air flow and noise level of fans without
external housing depend on the installation
conditions. The stated air flow and noise levels
have been measured under the
following conditions:
Centrifugal fan mounted on a base plate
220 x 220 mm. Cover plate 220 x 220 mm
with an air inlet of Ø 86 mm, concentric to
the impeller.
2
100
80
0,3
1
0,2
60
0,1
40
20
0
10
20
20
30
40
40
60
50
80
50 Hz
170
HP
60
CFM
100
m³/h
60 Hz
Û S
P
IP54
Curve
Frequency
m3/h
Nominal data
at T max
Nominal voltage
Type
Air flow
Air flow
– AC centrifugal fan with external rotor shaded-pole motor. Impedance protected
against overloading.
– Impeller of fibreglass-reinforced plastic, with steel plate reinforced.
– Direction of air flow radial. Direction of rotation clockwise, seen on rotor.
– Electrical connection via leads AWG 22. Bared and tin-plated.
– Mass: 500 g.
Hours
Information
AC centrifugal fans
Series RER 160
176 Ø x 54 mm
TypType
dB(A)
Bel(A) Bel
/ /
Watts
Watts
RPM
RPM
DC axial fans
Curve
DC centrifugal fans
°C °C
at T max
Service life L10
at 40 °C
Temperature range
Nominal speed
Power input
Sintec sleeve bearings
Ball bearings
Hz Hz
Sound power level
Frequency
Nominal data
Air flow
3/s V DCV
m3m
/h3/h10-3 m
CFM
Air flow
Nominal voltage
– AC centrifugal fan with external rotor shaded-pole motor. Impedance protected
against overloading.
– Impeller of fibreglass-reinforced plastic, with steel plate reinforced.
– Direction of air flow radial. Direction of rotation counter-clockwise, seen on rotor.
– Electrical connection via leads AWG 18. Bared and tin-plated.
– Mass: 1.0 kg.
Hours
Hours Hours
Hours
234
137,7
230
50
6,6
/
45,0
2 800
-30...+60
30 000 / 20 000
1
RER 160-28/06S
274
161,3
115
60
6,8
/
46,0
3 250
-30...+70
30 000 / 15 000
2
ACmaxx / i-maxx
RER 160-28/56S
DC fans - specials
274 m3/h
max.
AC axial fans
AC centrifugal fans
Pa
[in H2O]
The air flow and noise level of fans without
external housing depend on the installation
conditions. The stated air flow and noise
levels have been measured under the
following conditions:
Centrifugal fan mounted on a base plate
260 x 260 mm. Cover plate 260 x 260 mm
with an air inlet of Ø 100 mm, concentric to
the impeller.
2
250
Accessories
50
0
30
60
50
100
90
150
120
200
50 Hz
150
250
CFM
m³/h
60 Hz
HP
Û S
P
IP54
171
Representatives
0,4
0,6
100
0,2
150
0,8
1
200
172
Information
Fan filter guard grilles
180
Inlet nozzles
182
Connection cables / Accessories
183
DC axial fans
174
AC axial fans
ACmaxx / i-maxx
DC fans - specials
Guard grilles
DC centrifugal fans
Accessories
Accessories
AC centrifugal fans
Everything that you need for your
fan. ebm-papst provides an
extensive range of accessories for
optimum fan operation: From
temperature sensing for speedcontrolled fans to finger guards of
all types, switched-mode power
supply, connecting cable, filter,
screens, spacers and assembly
parts. In addition to the accessories and assembly parts listed in
this catalogue, ebm-papst also
supplies numerous special parts
for fan operation. The sales
experts at ebm-papst will be
happy to assist you in your enquiries concerning fan assembly and
application.
173
Representatives
From selection to accessories:
Insist on the efficient and reliable
service provided by
ebm-papst.
Guard grilles
– Guard grille acc. to DIN EN ISO 13857 (previously EN 294), made of galvanised or nickelplated and passivated steel wire for device fans.
– Additional guard grilles that do not conform to DIN EN ISO 13857 are available on request.
– Our guard grilles are specially designed for use with ebm-papst fans. Their design ensures
maximum safety with minimum effect on the operating noise level. Note that when using
guard grilles from other manufacturers, compliance with safety-related distances will not
always be present.
Fan series
Guard grilles
Fan series
Guard grilles
Fan series
Guard grilles
400
LZ29-1
5600
LZ25
DV 6200
LZ37
Intake side
500
LZ31
5200
LZ35
DV 6200
LZ39
Outlet side
600
LZ28-1
5300
LZ53
DV 6400
LZ38
Intake side
3000
LZ23-1
5900
LZ35
DV 6400
LZ39
Outlet side
8000
LZ32-4 / LZ22-2
7000
LZ36
9000
LZ30-4 / LZ 30
6300
LZ37
4000
LZ30-4 / LZ 30
6400
LZ38
5100
LZ25
2200F
LZ22
LZ29-1
Fan size 40 x 40
LZ31
Fan size 50 x 50
LZ28-1
Fan size 60 x 60
50
1,8
2 +0,3
4,
2±
4,5
0,
5
42
50
42
30+1
59
4,8
Fan size 92 x 92
LZ32-4
Fan size 80 x 80
LZ30-4
104,8
71,5
82,5
71,5
82,5
Fan size 119 x 119
2 + 0,3
2+0,3
40+1
_
92 1
174
0,
4,7+1
3+
40+1
78,2 ±0,5
2
4,
4,7+1
4,
4,
3+
0,
2
3+
0,
2
2 + 0,3
104,8
LZ23-1
4,2 +0,5
51,5 +1
_
119 1
4,7+1
Information
Fan size 135 x 135
LZ35
Fan size 127 x 127
LZ36
Fan size 150 x 172
LZ37
Fan size 172 Ø x 51
LZ38
Fan size 172 Ø x 51
LZ39
Fan size 172 Ø x 51
LZ53
Fan size 140 x 140
LZ30
Fan size 119 x 119
LZ22-2
AC axial fans
78±1
48±1
105,5 +0,5
115 ±1
153,5 ±1
+ 0,2
70
136,5
124,5
Fan size 80 x 80
3±0,25
4,3+0,2
+
6,45
2,5+0,3
5+1
2
0,
AC centrifugal fans
4,3+0,2
5
LZ22
ACmaxx / i-maxx
DC fans - specials
DC centrifugal fans
DC axial fans
LZ25
+1
Fan size 200 x 51
8,
14
(
Accessories
199,5 + 0,5
186,5 )
5
8,45
+1
175
Representatives
5 + 0,2
27,5
ACmaxx guard grilles
– Guard grille acc. to DIN EN ISO 13857 (previously EN 294), made of galvanised or nickelplated and passivated steel wire for device fans.
– The guard grilles shown on this page are designed specially for ACmaxx series fans and
are installed on the outlet side.
Fan series
Guard grilles
Fan series
Guard grilles
AC 8300
LZ32-4
Intake side s.P.174
AC 6200 N
LZ37
Intake side s.P.175
AC 8300 H
LZ32-7
Outlet side
AC 6200 N
LZ37-2
Outlet side
AC 3200 J
LZ23-1
Intake side s.P.174
AC 6100 N
LZ37
Intake side s.P.175
AC 3200 J
LZ23-6
Outlet side
AC 6100 N
*
Outlet side
AC 4400 FN
LZ30-4
Intake side s.P.174
*Outlet-side grilles on request
AC 4400 FN
LZ30-9
Outlet side
AC 4300
LZ30-4
Intake side s.P.174
AC 4300
LZ30-9
Outlet side
ACi 4400
LZ30
Intake side s.P.175
ACi 4400
LZ30
Outlet side s.P.175
LZ30-9
Fan size 119 X 119
LZ37-2
Fan size 172 Ø X 51
LZ23-6
Fan size 92 x 92
82,5
+ 0,2
51,5
89
2,5
2 +0,3
4,
3+
0,
2
4,5 +
4,7+1
51,5 +1
119 -1
LZ32-7
Fan size 80 x 80
0,5
79,8
+ 0,2
61,1 + 0,25
71,5
4,5 +
0,1
6,3 +
12,9
176
63,7
9
8,
15
104,8
Ø
+0,5
162 ±0,3
104,8
0,3
+ 0,3
4,3 ±0,2
6 ±0,5
0,1
7,3
Information
Guard grilles
W1G 250
09418-2-4039
W2E 250
09418-2-4039
W2E 200
78128-2-4039
78128-2-4039
Size 200
09418-2-4039
ACmaxx / i-maxx
78128-2-4039
Size 250
AC axial fans
Guard grilles
W4S 200
AC centrifugal fans
Fan series
78128-2-4039
Accessories
Guard grilles
W1G 200
177
Representatives
Fan series
DC fans - specials
DC centrifugal fans
DC axial fans
– Steel wire, plastic-coated, silver-metallic gloss.
Guard grilles
– Guard grille acc. to DIN EN ISO 13857 (previously EN 294), made of fibreglass-reinforced
plastic.
– Plastic grilles must not be used for the following models:
8200 JH3 / JH4
3200 JH3 / JH4
4100 NH5 - NH8
Guard grilles Mounting
B
C
D
E
Guard grilles Mounting
B
C
D
E
LZ32-2
A1
80-0,5
71,5±0,2
7,0
34
LZ30-5
A2
119-0,5
105±0,2
6,5
50
A3
80-0,5
71,5±0,2
A4
119-0,5
105±0,2
6,5
50
LZ23-2
A1
92,5-0,5
82,5±0,2
6,5
46
LZ33-1
A2
127-0,5
113,5±0,2
6,5
50
LZ23-3
A3
92,5-0,5
82,5±0,2
6,5
46
LZ33-2
A4
127-0,5
113,5±0,2
6,5
50
LZ32-3
7,0
34
LZ30-6
Screw connection
LZ32-2 / LZ32-3
Size 80 x 80
LZ23-2 / LZ23-3
Size 92 x 92
LZ30-5 / LZ30-6
Size 119 x 119
LZ33-1 / LZ33-2
Size 127 x 127
Barbed inserts
Suitable for bore diameters 4.3 - 4.7 only.
LZ32P
178
Fan size 80 x 80
LZ30P
Fan size 119 x 119
Information
Guard grilles
for compact centrifugal modules
9,0
RG 220
LZ47
166
8,7
RG 225
LZ48
158
8,7
a
b
ACmaxx / i-maxx
133
AC axial fans
b
LZ46
AC centrifugal fans
Guard grilles
Accessories
a
RG 190
179
Representatives
Fan series
DC fans - specials
DC centrifugal fans
DC axial fans
– PA plastic 6, fibreglass-reinforced
Fan filter guard grilles
–
–
–
–
Fan series DC
Fan series AC
4400 F
AC 4300
4400 FN
9900
4300
4000 N
4300 N
4000 Z
Filter guard grilles consist of a mounting plate, filter and screen.
Screen LZ40 N made of black, fibreglass-reinforced plastic with inserted wire netting LZ60.
Filter LZ60 made of Nirosta stainless steel wire netting.
Mounting plate LZ40-1 for installation.
4400
4200
4100 N
LZ40N
180
Screen
LZ40-1
Bracket
LZ60
Filter
Fan size
A
B
C
D
FF60
60 x 60 mm
65
65
13,5
50,0
Information
Replacement filter*
RF 60
FF80
80 x 80 mm
85
85
14,0
71,5
RF 80
FF92
92 x 92 mm
125
105
17,5
82,5
RF 92
FF119
119 x 119 mm
162
136
18,5
104,5
RF 119
FF172
ø 172 mm
226
190
19,5
162,0
RF 172
DC fans - specials
Protection filter
FF92 / FF 119
A
C
D
A
C
D
AC centrifugal fans
D
AC axial fans
D
D
C
B
A
92 x 92 mm
119 x 119 mm
FF 172
Accessories
Filter capacity
A fan filter guard filters out up to 75% of
dust particles up to a size of 5-10 microns
and withstands temperatures of up to
100°C. Flame retardant in accordance with
DIN 53438, grade F1. For installed, clean
filters, an air flow reduction of 20 – 30%
can be assumed.
¯172 mm
B
Fan size:
181
Representatives
Fan size:
60 x 60 mm
80 x 80 mm
B
Fan size:
ACmaxx / i-maxx
* Replacement filters only in packs of 5.
FF60 / FF80
DC axial fans
– Filter guard grille suitable for attachment to axial fan series of size 60 mm, 80 mm, 92 mm,
119 mm, ø 172 mm. All filter units fit directly onto the existing installation holes of the fans.
– Filter guard grille consisting of 3 parts: outer grille barrier, inner fastening plate and replaceable filter mat.
– Grille barrier made of moulded polycarbonate (PC), with matted surface.
– Fast and easy exchange of filter mat via a quick release on the grille barrier.
– Fastening plate made of wire netting, with black powder coating.
– Filter mat can be replaced while the fan is running, protection provided by welded wire
netting.
– Filter mat made of white, synthetically bonded fibres.
DC centrifugal fans
Fan filter guard grilles
Inlet nozzles
for centrifugal fans
– Material: Sheet steel, galvanised
Fan
Vers.
k
m
o
q
r1
s
t
u
No.:
RET 97
(S)
1
116,0
80,0
10,0
0,80
10,0
108,0
3x4,5
–
LZ 1000-097
RER 120
(P)
1
146,0
94,4
18,0
0,80
16,0
134,0
4x4,5
126,0
LZ 1000-120
RER 133
(P)
1
129,0
87,0
13,0
1,00
8,0
118,0
4x4,5
103,0
LZ 1000-133
RER 175 / 190 (P)
1
170,0
125,5
14,0
1,25
10,0
158,0
4x4,5
146,0
LZ 1000-175
RER 220
(P)
2
252,0
155,0
21,0
0,80
22,0
–
–
199,0
LZ 1000-220
RER 225
(P)
1
223,0
146,0
28,0
1,50
25,0
210,0
4x4,5
196,0
LZ 1000-225
(P) = plastic, (S) = sheet steel
Vers. 1
Vers. 2
45
118
°
4,
5
24
Øs
Øu
Øk
Øm
182
242
r1
q
t
6x
60
°
5,5
4 x 90°
3
0
Information
Connector cables
610
LZ120-4
2 000
LZ120-5
380
LZ120-6
610
Leads
DC axial fans
Plug
Leads end
Lead colour
Receptacle for tabs
0,5 mm2
0,5 mm2
G
C
black/black
2,8 x 0,5
Application
AC
G
A
black/black
2,8 x 0,5
AC
0,5 mm2
0,5 mm2
W
B
red/black
2,8 x 0,5
DC
W
B
red/black
2,8 x 0,5
DC
0,5 mm2
0,5 mm2
G
A
red/black
2,8 x 0,5
DC
G
B
black/black
2,8 x 0,5
AC
G
A
black/black
2,8 x 0,5
AC
LZ120-11
2 000
LZ120-16
800
LZ120-18
4 000
LZ126
1 000
0,5 mm2
0,5 mm2
G
C
black/black
2,8 x 0,5
AC
LZ127
1 600
0,5 mm2
G
B
black/black
2,8 x 0,5
AC
0,82 mm2
0,73 mm2
G
C
black/black
2,8 x 0,5
AC
G
B
black/black
2,8 x 0,8
AC
LZ130-1
610
LZ140
610
10
AC centrifugal fans
L1
Angled plug (W)
8
6
8,5 ±0,1
4
20 +0,5
8
L1
Leads end A
Tin-plated
Leads end B
Core end sleeve
Leads end C
ȯ1,5
Core crimp sleeve
5,5 –0,25
ȯ1,5
7,5
6
10+5
–2
6
183
Accessories
31
3,5 –0,25
Connector cable
4
Representatives
22,5
AC axial fans
8,5 ±0,1
7,5
11
16 –0,5
2±0,2
Straight plug (G)
16,5
15
12
Connector cable
DC centrifugal fans
L1 (mm)
LZ120
DC fans - specials
Plug model
Connector cable with injection-moulded plug in various lengths.
Strand ends with core-crimping sleeve, core-end sleeve or tin-plated.
Straight or angled plug.
For all types of fan with flat plug 2.8 / 3.0 x 0.5.
ACmaxx / i-maxx
–
–
–
–
Accessories
In addition to the accessories and assembly parts listed in this catalogue, ebm-papst also
supplies numerous special parts for fans. The sales experts at ebm-papst will be happy to
assist you in your enquiries concerning fan assembly and application.
Fan series
Accessories
Fan series
Accessories
8300
LZ212 / LZ260
5100
LZ210
8400 N
LZ261
5600
LZ210
3300
LZ212 / LZ260
5200
LZ210
3400 N
LZ261
5900
LZ210
9000
LZ210
7000
LZ210
4000
LZ210
VARIOFAN
LZ370
4300
LZ212 / LZ260
8300
LZ212
LZ212
LZ260/LZ261
LZ210
Screw clip of stainless steel.
For mounting fans with threaded
pin 3.5 DIN EN ISO 1478 (7970).
Spacer of fibreglass reinforced plastic. For
screw mounting over both fan mounting flanges.
Screw clip of hardened steel. For mounting
fans with threaded pin 6-32 UNC and/or 3.5
DIN 7970.
LZ370
LZ550
(2x) 0,5x45°
Pmax
= 0,25 W
5% @25°C
2%
50°
= 4190
0,5
12
Temperature sensor for speed-controlled
fan operation. Temperature range 30...50 °C.
184
6,9 ±0,1
11±0,3
(2x) Ø 4
= 100 K
B-value
Ø 11
R 25
Ø 6,6
Required performance data:
Rubber anti-vibration mounts
for fans with a hole ø of 4.3 ±0.2 mm and
flange thickness of 3 - 5.5 mm.
For a carrier plate with a hole ø of 6.5 ±0.15 mm and
plate thickness of 1 - 2 mm.
Representatives
185
Accessories
AC centrifugal fans
AC axial fans
ACmaxx / i-maxx
DC fans - specials
DC centrifugal fans
DC axial fans
Information
fan agent
compact fan agent
ebm-papst in Germany
motor specialist
motor agent
Germany
ebm-papst
Mulfingen GmbH & Co. KG
ebm-papst
St. Georgen GmbH & Co. KG
ebm-papst
Landshut GmbH
Bachmühle 2
D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com
Hermann-Papst-Straße 1
D-78112 St. Georgen
Phone +49 7724 81-0
Fax +49 7724 81-1309
info2@de.ebmpapst.com
Hofmark-Aich-Straße 25
D-84030 Landshut
Phone +49 871 707-0
Fax +49 871 707-465
info3@de.ebmpapst.com
www.ebmpapst.com
www.ebmpapst.com
www.ebmpapst.com
Agencies
Berlin
Dipl.-Ing. (TH) Jens Duchow
Händelstraße 7
D-16341 Panketal
Phone +49 30 944149-62
Fax +49 30 944149-63
Jens.Duchow@de.ebmpapst.com
Bielefeld
Dipl.-Ing. (FH) Wolf-Jürgen Weber
Niehausweg 13
D-33739 Bielefeld
Phone +49 5206 91732-31
Fax +49 5206 91732-35
Wolf-Juergen.Weber@de.ebmpapst.com
Dortmund
Dipl.-Ing. (FH) Hans-Joachim Pundt
Auf den Steinern 3
D-59519 Möhnesee-Völlinghausen
Phone +49 2925 800-407
Fax +49 2925 800-408
Hans-Joachim.Pundt@de.ebmpapst.com
Frankfurt
Dipl.-Ing. Christian Kleffmann
Dr.-Hermann-Krause-Straße 23
D-63452 Hanau
Phone +49 6181 1898-12
Fax +49 6181 1898-13
Christian.Kleffmann@de.ebmpapst.com
Halle
Dipl.-Ing. (TU) Michael Hanning
Lercheneck 4
D-06198 Salzatal / OT Lieskau
Phone +49 345 55124-56
Fax +49 345 55124-57
Michael.Hanning@de.ebmpapst.com
Hamburg
Ingenieurbüro Breuell GmbH
Ing. Dirk Kahl
Elektroingenieur
Grützmühlenweg 40
D-22339 Hamburg
Phone +49 40 538092-19
Fax +49 40 538092-84
Dirk.Kahl@de.ebmpapst.com
186
Heilbronn / Heidelberg
Dipl.-Ing. Mark Gartner
Gehrweg 12
D-74199 Unterheinriet
Phone +49 7130 404569-1
Fax +49 7130 404569-2
Mark.Gartner@de.ebmpapst.com
Kassel
Dipl.-Ing. (FH) Ralph Brück
Hoherainstraße 3 b
D-35075 Gladenbach
Phone +49 6462 4071-10
Fax +49 6462 4071-11
Ralph.Brueck@de.ebmpapst.com
Koblenz
Winfried Schaefer
Hinter der Kirch 10
D-56767 Uersfeld
Phone +49 2657 16-96
Fax +49 2657 16-76
Winfried.Schaefer@de.ebmpapst.com
Munich
Dipl.-Wirt.-Ing. (FH) Jens Peter
Uhlandstraße 6
D-74427 Fichtenberg
Phone +49 7971 260-180
Fax +49 7971 260-221
Jens.Peter@de.ebmpapst.com
Nuremberg
Dipl.-Wirt.-Ing. (FH) Axel Resch
Steinsfeldstraße 80
D-74626 Bretzfeld
Phone +49 7946 94401-02
Fax +49 7946 94401-03
Axel.Resch@de.ebmpapst.com
Offenburg
Dipl.-Ing. (FH) Ralf Braun
Hubeneck 21
D-77704 Oberkirch
Phone +49 7802 9822-52
Fax +49 7802 9822-53
Ralf.Braun@de.ebmpapst.com
Stuttgart
Dipl.-Ing. (FH) Rudi Weinmann
Hindenburgstraße 100/1
D-73207 Plochingen
Phone +49 7153 9289-80
Fax +49 7153 9289-81
Rudi.Weinmann@de.ebmpapst.com
Ulm
M.Sc. Reinhard Sommerreißer
Am Silbermannpark 10
D-86161 Augsburg
Phone +49 821 6610-7023
Fax +49 821 6610-7024
Reinhard.Sommerreisser@de.ebmpapst.com
Distributors
Burgdorf
ETB Electronic Team
Beratungs- u. Vertriebs GmbH
Wundramweg 1
31303 Burgdorf
Phone +49 5136 97229-30
Fax +49 5136 97229-39
info@etb-electronic.de
www.etb-electronic.de
Frankfurt
R.E.D. Handelsgesellschaft mbH
Gutenbergstraße 3
D-63110 Rodgau - Jügesheim
Phone +49 6106 841-0
Fax +49 6106 841-111
info@red-elektromechanik.de
www.red-elektromechanik.de
Arrow Central Europe GmbH
Max-Planck-Straße 1-3
63303 Dreieich
Phone +49 6103 304-8
Fax +49 6103 304-8562
spoerle@spoerle.e-mail.com
www.spoerle.com
Hamburg
Breuell + Hilgenfeldt GmbH
Grützmühlenweg 40
D-22339 Hamburg
Phone +49 40 538092-20
Fax +49 40 538092-84
info@breuell-hilgenfeldt.de
Walter Kluxen GmbH
Neuer Höltigbaum 6
20097 Hamburg
Phone +49 40 237010
Fax +49 40 23701309
Multi-Bauelemente-Service
Vertrieb von elektr. Bauelementen GmbH
Römerstraße 8
85661 Forstinning
Phone +49 8121 2506-0
Fax +49 8121 2506-200
multi.bauelemente@mbs.to
Belarus
ebm-papst Bel AgmbH
P.O. Box 117
BY-220138 Minsk
Phone +375 17 3851556
Fax +375 17 3851556
info@by.ebmpapst.com
www.ebmpapst.by
North
Breuell + Hilgenfeldt GmbH
Grützmühlenweg 40
D-22339 Hamburg
Phone +49 40 538092-20
Fax +49 40 538092-84
ebmpapst@breuell-hilgenfeldt.de
South
Scheffel
elektrotechnischer Vertrieb GmbH
Aischbach 1
70839 Gerlingen
Phone +49 7156 28357
Fax +49 7156 49425
info@ebmpapst-service.de
Belgium
ebm-papst Benelux B.V.
Sales office Belgium-Luxemburg
Romeinsestraat 6/0101
Research Park Haasrode
B-3001 Heverlee-Leuven
Phone +32 16 396-200
Fax +32 16 396-220
info@be.ebmpapst.com
www.ebmpapst.be
Information
Croatia
ebm-papst Industries Kft.
Ezred u. 2.
H-1044 Budapest
Phone +36 1 8722-190
Fax +36 1 8722-194
office@hu.ebmpapst.com
Compex Ges.m.b.H
Wurlitzergasse 10/3
A -1160 Wien
Phone +43 1 4804223
Fax +43 1 4864230
compex.wien@utanet.at
Czech Republic / Slovakia
ebm-papst CZ s.r.o.
Kaštanová 34a
CZ-620 00 Brno
Phone +420 544 502-411
Fax +420 547 232-622
info@ebmpapst.cz
www.ebmpapst.cz
Avnet Time Diegem
Eagle Building
Kouterveldstraat 20
B-1831 Diegem
Phone +32 27 099003
Fax +32 27 099801
TimeBe@avnet.com
www.avnettime.com
Accessories
(1 to 5 pieces)
DC fans - specials
Avnet Time Vienna
Diefenbachgasse 35/2
A-1150 Vienna
Phone +43 1 8664 20
Fax +43 1 8664 2250
TimeAustria@avnet.com
www.avnettime.com
ACmaxx / i-maxx
Munich
A. Schweiger GmbH
Ohmstraße 1
D-82054 Sauerlach
Phone +49 8104 897-0
Fax +49 8104 897-90
info@schweiger-gmbh.de
www.schweiger-gmbh.com
Compex Ges.m.b.H
Wurlitzergasse 10/3
A -1160 Wien
Phone +43 1 4804223
Fax +43 1 4864230
compex.wien@utanet.at
AC axial fans
Austria
ebm-papst Motoren & Ventilatoren GmbH
Straubingstraße 17
A-4030 Linz
Phone +43 732 321150-0
Fax +43 732 321150-20
info@at.ebmpapst.com
www.ebmpapst.at
Bulgaria
ebm-papst Romania S.R.L.
Str. Tarnavei Nr. 20
RO-500327 Brasov
Phone +40 268 312-805
Fax +40 268 312-805
dudasludovic@xnet.ro
AC centrifugal fans
Europe
187
Representatives
Klausdorf
ETB Electronic Team
Beratungs- u. Vertriebs GmbH
Zossener Straße 27
15838 Klausdorf
Phone +49 33703 69-0
Fax +49 33703 69-149
info@etb-electronic.de
www.etb-electronic.de
DC centrifugal fans
DC axial fans
ebm-papst in Germany and Europe
fan agent
compact fan agent
ebm-papst in Europe
motor specialist
motor agent
Denmark
ebm-papst Denmark ApS
Vallensbækvej 21
DK-2605 Brøndby
Phone +45 43 631111
Fax +45 43 630505
mail@dk.ebmpapst.com
www.ebmpapst.dk
Estonia
ebm-papst Oy, Eesti Filiaal
Kesk tee 13
Aaviku küla, Jüri Tehnopark
EST-75301 Rae Vald, Harjumaa
Phone +372 65569-78
Fax +372 65569-79
www.ebmpapst.ee
Finland
ebm-papst Oy
Puistotie 1
FIN-02760 Espoo
Phone +358 9 887022-0
Fax +358 9 887022-13
mailbox@ebmpapst.fi
www.ebmpapst.fi
France
ebm-papst SARL
ZI Nord - rue A. Mohler
BP 62
F-67212 Obernai-Cedex
Phone +33 820 326266
Fax +33 3 88673883
info@ebmpapst.fr
www.ebmpapst.fr
Greece
Helcoma
Th. Rotas & Co OE
Davaki 65
GR-17672 Kallithea-Attiki
Phone +30 210 9513-705
Fax +30 210 9513-490
contact@helcoma.gr
www.helcoma.gr
Assimacopoulos S.A.
11, Karitsi Square
GR-10561 Athen
Phone +30 10 322 1737
Fax +30 10 322 5708
assimac@interagora.gr
www.assimacopoulos.gr
188
Hungary
ebm-papst Industries Kft.
Ezred u. 2.
H-1044 Budapest
Phone +36 1 8722-190
Fax +36 1 8722-194
office@hu.ebmpapst.com
Macedonia
ebm-papst Industries Kft.
Ezred u. 2.
H-1044 Budapest
Phone +36 1 8722-190
Fax +36 1 8722-194
office@hu.ebmpapst.com
Compex KFT.
Elete út 56/B
H-1115 Budapest
Phone +36 12 0657 25
Fax +36 12 0657 71
compex@vnet.hu
Netherlands
ebm-papst Benelux B.V.
Engelseweg 127
NL-5705 AC Helmond
Phone +31 492 502-900
Fax +31 492 502-950
verkoop@nl.ebmpapst.com
www.ebmpapst.nl
Iceland
RJ Engineers
Stangarhyl 1a
IS-110 Reykjavik
Phone +354 567 8030
Fax +354 567 8015
rj@rj.is
www.rj.is
Ireland
ebm-papst UK Ltd.
Chelmsford Business Park
GB-Chelmsford Essex CM2 5EZ
Phone +44 1245 468555
Fax +44 1245 466336
sales@uk.ebmpapst.com
www.ebmpapst.co.uk
AuBren Limited
Portlaoise Business & Technology Park
Mountrath Road
IRL-Portlaoise, Co. Laois
Phone +353 57 8664343
Fax +353 57 8664346
sales@ie.aubren.com
www.aubren.com
Italy
ebm-papst Srl
Via Cornaggia 108
I-22076 Mozzate (Co)
Phone +39 0331 836201
Fax +39 0331 821510
info@it.ebmpapst.com
www.ebmpapst.it
Avnet Time Breda
Takkebijsters 2
NL-4817 BL Breda
Phone +31 765 722300
Fax +31 765 722303
Time NL@avnet.com
www.avnettime.com
Norway
ebm-papst AS
P.B. 173 Holmlia
N-1203 Oslo
Phone +47 22 763340
Fax +47 22 619173
mailbox@ebmpapst.no
www.ebmpapst.no
Poland
ebm-papst Polska Sp. z o.o.
ul. Annopol 4A
PL-03236 Warszawa
Phone +48 22 6757819
Fax +48 22 6769587
office@ebmpapst.pl
www.ebmpapst.pl
Compex Ges.m.b.H
Wurlitzergasse 10/3
A -1160 Wien
Phone +43 1 4804223
Fax +43 1 4864230
compex.wien@utanet.at
ebm-papst Rus GmbH
proezd 4529, vladenie 5, stroenie 1
RU-141000 Mytistschi, Oblast Moskau
Phone +7 495 9807524
Fax +7 495 5140924
info@ebmpapst.ru
www.ebmpapst.ru
Serbia & Montenegro
ebm-papst Industries Kft.
Ezred u. 2.
H-1044 Budapest
Phone +36 1 8722-190
Fax +36 1 8722-194
office@hu.ebmpapst.com
Information
DC fans - specials
ACmaxx / i-maxx
AC axial fans
Russia
ebm-papst Ural GmbH
Posadskaja-Strasse, 23(E), 3
RU-620102 Ekaterinburg
Phone +7 343 2338000
Fax +7 343 2337788
Konstantin.Molokov@ru.ebmpapst.com
www.ebmpapst.ur.ru
Switzerland
ebm-papst AG
Rütisbergstrasse 1
CH-8156 Oberhasli
Phone +41 44 73220-70
Fax +41 44 73220-77
verkauf@ebmpapst.ch
www.ebmpapst.ch
ebm-papst Automotive & Drives (UK) Ltd.
The Smithy
Fidlers Lane
GB-East Ilsley, Berkshire RG20 7LG
Phone +44 1635 2811-11
Fax +44 1635 2811-61
A&Dsales@uk.ebmpapst.com
www.ebmpapst-ad.com
Omni Ray AG
Im Schörli 5
CH-8600 Dübendorf
Phone +41 44 802 2880
Fax +41 44 802 2828
r.borner@omniray.ch
www.omniray.ch
AC centrifugal fans
Compex Ges.m.b.H
Wurlitzergasse 10/3
A -1160 Wien
Phone +43 1 4804223
Fax +43 1 4864230
compex.wien@utanet.at
Sweden
ebm-papst AB
Äggelundavägen 2
S-17562 Järfälla
Phone +46 8 7619400
Fax +46 8 362306
info@ebmpapst.se
www.ebmpapst.se
United Kingdom
ebm-papst UK Ltd.
Chelmsford Business Park
GB-Chelmsford Essex CM2 5EZ
Phone +44 1245 468555
Fax +44 1245 466336
sales@uk.ebmpapst.com
www.ebmpapst.co.uk
Turkey
Akantel Elektronik San. Tic. LTD. Sti.
Atatürk Organize Sanayi
Bölgesi 10007 SK. No.:6
TR-35620 Cigli-Izmir
Phone +90 232 3282090
Fax +90 232 3280270
akantel@akantel.com.tr
www.ebmpapst.com.tr
Ukraine
ebm-papst Ukraine LLC
Lepse Boulevard, 4, Building 47
UA-03067 Kiev
Phone +38 044 2063091
Fax +38 044 2063091
mail@ebmpapst.ua
www.ebmpapst.ua
Accessories
Romania
ebm-papst Romania S.R.L.
Str. Tarnavei Nr. 20
RO-500327 Brasov
Phone +40 268 312-805
Fax +40 268 312-805
dudasludovic@xnet.ro
Spain
ebm-papst Ibérica S.L.
Avda. del Sistema Solar, 29
E-28830 San Fernando de Henares (Madrid)
Phone +34 91 6780894
Fax +34 91 6781530
ventas@ebmpapst.es
189
Representatives
Portugal
ebm-papst (Portugal), Lda.
Centro Empresarial de Alverca
Rua de Adarse, Vale D’Ervas
Corpo D / Fracção 3
P-2615-178 Alverca do Ribatejo
Phone +351 218 394 880
Fax +351 218 394 759
info@pt.ebmpapst.com
www.ebmpapst.pt
DC centrifugal fans
DC axial fans
ebm-papst in Europe
fan agent
compact fan agent
ebm-papst in America, Africa and Asia
motor specialist
motor agent
America
Argentina
ebm-papst de Argentina S.A.
Hernandarias 148 Lomas del Mirador
Pcia. de Buenos Aires (1752)
Phone +54 11 46576135
Fax +54 11 46572092
ventas@ar.ebmpapst.com
www.ebmpapst.com.ar
Brasil
ebm-papst Motores Ventiladores Ltda.
Av. José Giorgi, 301 Galpões B6+B7
Condominio Logical Center
BR-06707-100 Cotia - São Paulo
Phone +55 11 4613-8700
Fax +55 11 3164-8924
vendas@br.ebmpapst.com
www.ebmpapst.com.br
Canada
ebm-papst Canada Inc.
1800 Ironstone Manor, Unit 2
CDN-Pickering, Ontario, L1W3J9
Phone +1 905 420-3533
Fax +1 905 420-3772
sales@ca.ebmpapst.com
www.ebmpapst.ca
Mexico
ebm Industrial S.de R.L. de C.V.
Paseo de Tamarindos 400-A-5to Piso
Col. Bosques de las Lomas
MEX-Mexico 05120, D.F.
Phone +52 55 3300-5144
Fax +52 55 3300-5243
sales@mx.ebmpapst.com
www.ebmpapst.com.mx
USA
ebm-papst Inc.
P.O. Box 4009
100 Hyde Road
USA-Farmington, CT 06034
Phone +1 860 674-1515
Fax +1 860 674-8536
sales@us.ebmpapst.com
www.ebmpapst.us
ebm-papst Automotive & Drives, Inc.
3200 Greenfield, Suite 255
USA-Dearborn, MI 48120
Phone +1 313 406-8080
Fax +1 313 406-8081
automotive@us.ebmpapst.com
www.ebmpapst-automotive.us
Africa
South Africa
ebm-papst South Africa (Pty) Ltd.
P.O. Box 3124
1119 Yacht Avenue
ZA-2040 Honeydew
Phone +27 11 794-3434
Fax +27 11 794-5020
info@za.ebmpapst.com
www.ebmpapst.co.za
Retron CC
P.O. Box 3 94 48, Bramley, 2018
SSF-Building, 706 - 4th Street, Wynberg
ZA-Johannesburg
Phone +27 11 7860553
Fax +27 11 4408275
Asia
China
ebm-papst Ventilator (Shanghai) Co., Ltd.
No. 418, Huajing Road
WaiGaoQiao Free Trade Zone
No. 2001, Yang Gao (N) Road
VRC-200131 Shanghai, P.R. of China
Phone +86 21 5046-0183
Fax +86 21 5046-1119
sales@cn.ebmpapst.com
www.ebmpapst.com.cn
Hong Kong
ebm-papst Hong Kong Ltd.
Unit No. 13,9 / F
Technology Park, 18 On Lai Street
Siu Lek Yuen, Shatin N.T.
Hong Kong - P.R. of China
Phone +852 2145-8678
Fax +852 2145-7678
info@hk.ebmpapst.com
India
ebm-papst India Pvt. Ltd.
26/3, G.N.T. Road, Erukkencherry
IND-Chennai-600118
Phone +91 44 25372556
Fax +91 44 25371149
sales@in.ebmpapst.com
www.ebmpapst.in
Indonesia
ebm-papst Indonesia
Representative Office
German Centre, 4th Floor, Suite 4470
Jl. Kapt. Subijono Dj. Bumi Serpong Damai
RI-15321 Tangerang
Phone +62 21 5376250
Fax +62 21 5388305
salesdept@id.ebmpapst.com
Israel
Polak Bros. Import Agencies Ltd.
9 Hamefalsim Street
IL-Kiryat Arie, Petach-Tikva 49514
Phone +972 3 9100300
Fax +972 3 5796679
polak@polak.co.il
www.polak.co.il
190
Malaysia
ebm-papst Malaysia
Representative Office
Unit 12-2, Jalan USJ Sentral 3
Persiaran Subang, Selangor Darul Ehsan
MAL-47600 Subang Jaya
Phone +60 3 8024-1680
Fax +60 3 8024-8718
salesdept@my.ebmpapst.com
Information
DC fans - specials
Australia
ebm-papst A&NZ Pty Ltd.
10 Oxford Road
AUS-Laverton North, Victoria, 3026
Phone +61 3 9360-6400
Fax +61 3 9360-6464
sales@ebmpapst.com.au
www.ebmpapst.com.au
New Zealand
ebm-papst A&NZ Pty Ltd.
102 Henderson Valley Road
NZ-Henderson, Auckland 1230
Phone +64 9 837-1884
Fax +64 9 837-1899
sales@ebmpapst.com.au
www.ebmpapst.com.au
ACmaxx / i-maxx
United Arab Emirates
ebm-papst Middle East FZE
PO Box 17755
Jebel Ali Free Zone / FZS1 / AP05
UAE-Dubai
Phone +971 4 88608-26
Fax +971 4 88608-27
info@ae.ebmpapst.com
www.ebmpapst.ae
Australia
Vietnam
ebm-papst Vietnam
Representative Office
Room #102, 25 Nguyen Van Thu Street
District 1
VN-Ho Chi Minh City
Phone +84 8 39104099
Fax +84 8 39103970
linh.nguyen@vn.ebmpapst.com
AC axial fans
Korea
ebm-papst Korea Co. Ltd.
6F, Trutec Bldg.
B 6-2, Digital Media City (DMC)
Sangam-Dong, Mapo-Gu
ROK-Seoul 121-270
Phone +82 2 366213-24
Fax +82 2 366213-26
info@kr.ebmpapst.com
www.ebmpapst.co.kr
Thailand
ebm-papst Thailand Co., Ltd.
99/349 Na-Nakorn Bldg., 4th Floor
Chaeng Wattana Road, Thungsonghong,
THA-10210 Laksi, BKK
Phone +66 2 57615-24
Fax +66 2 57615-42
salesdept@th.ebmpapst.com
AC centrifugal fans
Singapore
ebm-papst SEA Pte. Ltd.
No. 23 Ubi Road 4
#06-00 Olympia Industrial Building
SGP-Singapore 408620
Phone +65 65513789
Fax +65 68428439
salesdept@sg.ebmpapst.com
Accessories
Taiwan
ETECO Engineering & Trading Corp.
10F-I, No. 92, Teh-Wei Str.
RC-Tsow-Inn District, Kaohsiung
Phone +886 7 557-4268
Fax +886 7 557-2788
eteco@ms22.hinet.net
www.ebmpapst.com.tw
191
Representatives
Japan
ebm-papst Industries Japan K.K.
12 Floor, Benex S-3 Bldg.
3-20-8 Shinyokohama, Kohoku-ku
J-222-0033 Yokohama
Phone +81 45 47057-51
Fax +81 45 47057-52
info@jp.ebmpapst.com
www.ebmpapst.jp
DC centrifugal fans
DC axial fans
ebm-papst in Asia and Australia
37634-7-8811 · RA-12/10-10’
L1136 · 980 0000 047
Printed in Germany
ebm-papst
ebm-papst
ebm-papst
St. Georgen GmbH & Co. KG
Mulfingen GmbH & Co. KG
Landshut GmbH
Hermann-Papst-Straße 1
Bachmühle 2
Hofmark-Aich-Straße 25
D-78112 St. Georgen
D-74673 Mulfingen
D-84030 Landshut
Phone +49 7724 81-0
Phone +49 7938 81-0
Phone +49 871 707-0
Fax +49 7724 81-1309
Fax +49 7938 81-110
Fax +49 871 707-465