0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
G1G120-AB67-02

G1G120-AB67-02

  • 厂商:

    EBMPAPST(依必安派特)

  • 封装:

    -

  • 描述:

    FAN BLOWER 178X115MM 24VDC WIRE

  • 数据手册
  • 价格&库存
G1G120-AB67-02 数据手册
EC centrifugal fan G1G120-AB67-02 forward curved, single inlet with housing (flange) ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 · D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership · Headquarters Mulfingen County court Stuttgart · HRA 590344 General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen County court Stuttgart · HRB 590142 Nominal data Type G1G120-AB67-02 Motor M1G055-BD Nominal voltage VDC 24 Nominal voltage range VDC 16 .. 28 Type of data definition fa Speed min-1 2200 Power input W 40 Current draw A 1.9 Min. ambient temperature °C -25 Max. ambient temperature °C 60 ml = Max. load · me = Max. efficiency · fa = Running at free air · cs = Customer specs · cu = Customer unit Subject to alterations Item no. 50907-5-9980 · Revision 82585 · Release 2014-05-08 · Page 1 / 5 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com EC centrifugal fan G1G120-AB67-02 forward curved, single inlet with housing (flange) Technical features Mass 1.57 kg Size 120 mm Surface of rotor Thick layer passivated Material of impeller Sheet steel, hot-galvanised Housing material Die-cast aluminium Direction of rotation Clockwise, seen on rotor Type of protection IP 22 Insulation class "B" Humidity class F0 Max. permissible ambient motor temp. (transp./ storage) + 80 °C Min. permissible ambient motor temp. (transp./storage) - 40 °C Mounting position Any Condensate discharge holes None Operation mode S1 Motor bearing Ball bearing Technical features - Control input 0-10 VDC / PWM - Tach output - Motor current limit - Soft start EMC interference immunity Acc. to EN 61000-6-2 (industrial environment) EMC interference emission Acc. to EN 61000-6-3 (household environment) Motor protection Reverse polarity and locked-rotor protection Cable exit Axial Product conforming to standard EN 60950-1 Approval CSA C22.2 Nr.77; EAC; UL 1004-1 Item no. 50907-5-9980 · Revision 82585 · Release 2014-05-08 · Page 2 / 5 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com G1G120-AB67-02 EC centrifugal fan forward curved, single inlet with housing (flange) Product drawing 1 Connection line AWG20, 4x brass lead tips crimped Item no. 50907-5-9980 · Revision 82585 · Release 2014-05-08 · Page 3 / 5 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com EC centrifugal fan G1G120-AB67-02 forward curved, single inlet with housing (flange) Connection screen No. Conn. Designation Colour Function / assignment 1 1 GND blue Reference mass 1 2 Tach white Speed monitoring output, 2 pulses per rotation, Isink max = 10 mA 1 3 0-10 VDC yellow Control input Re > 100 K 1 4 Un +24 VDC red Power supply 24 VDC, residual ripple 3.5 % Item no. 50907-5-9980 · Revision 82585 · Release 2014-05-08 · Page 4 / 5 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com EC centrifugal fan G1G120-AB67-02 forward curved, single inlet with housing (flange) Charts: Air flow Druck p f s[Pa]für Rho=1,2kg/m^3 qv[cfm] 500 0 20 40 60 80 100 120 140 160 480 2 1,9 460 1,8 440 4 420 1,7 400 1,6 380 1,5 360 3 340 1,4 8 1,3 320 300 1,2 pf s[Pa] 1,1 260 1 240 Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. 0,9 220 200 0,8 12 180 0,7 2 11 160 0,6 6 140 0,5 120 100 0,4 10 80 0,3 60 0,2 40 9 0 20 40 60 80 100 120 140 160 qv[m^3/h] 180 200 5 220 240 ] [Pa pf s ] [Pa pf s a] s[P pf 20 0 p fs_E[IN H2O] 7 280 Measurement: LU-48521 Measurement: LU-48520 Measurement: LU-48522 260 1 280 0,1 0 300 Measured values U n Ped I qv pfs V min-1 W A m3/h Pa 1 28 2380 49 2.09 270 0 2 28 2675 45 1.82 215 164 3 28 3025 39 1.54 155 348 4 28 3315 31 1.23 85 418 5 24 2200 40 1.90 250 0 6 24 2480 36 1.64 200 140 7 24 2730 29 1.34 140 280 8 24 2940 24 1.10 75 330 9 16 1750 19 1.32 195 0 10 16 1895 16 1.11 150 80 11 16 2050 13 0.92 105 155 12 16 2215 9.9 0.78 55 178 U = Supply voltage · n = Speed · Ped = Power input · I = Current draw · qv = Air flow · pfs = Pressure increase Item no. 50907-5-9980 · Revision 82585 · Release 2014-05-08 · Page 5 / 5 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
G1G120-AB67-02 价格&库存

很抱歉,暂时无法提供与“G1G120-AB67-02”相匹配的价格&库存,您可以联系我们找货

免费人工找货