K2E225-RA40-02

K2E225-RA40-02

  • 厂商:

    EBMPAPST(依必安派特)

  • 封装:

  • 描述:

    风扇 管轴式 115VAC 方形 - 270mm 长 x 270mm 高 滚珠 4 位置矩形连接器

  • 数据手册
  • 价格&库存
K2E225-RA40-02 数据手册
AC centrifugal module - RadiCal K2E225-RA40-02 backward-curved, single-intake with housing ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 · D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership · Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart · HRA 590344 General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart · HRB 590142 Nominal data Type K2E225-RA40-02 Motor M2E068-DF Phase 1~ 1~ 1~ Nominal voltage VAC 115 115 115 Frequency Hz 50 60 60 Method of obtaining data ml ml ml Valid for approval/standard CE CE UL 2111 Speed (rpm) min-1 2550 2700 2700 Power consumption W 165 225 235 Current draw A 1.47 1.95 1.97 Capacitor µF 14 14 14 Capacitor voltage VDB 250 250 250 Capacitor standard S0 (CE) S0 (CE) UL Min. back pressure Pa 0 0 0 Min. back pressure inH2O 0 0 0 Min. ambient temperature °C -25 -25 -25 Max. ambient temperature °C 60 60 60 Starting current A 2.9 2.7 2.8 ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment Subject to change Item no. 11022-5-9980 · ENU · Change 85808 · Approved 2016-09-14 · Page 1 / 6 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com AC centrifugal module - RadiCal K2E225-RA40-02 backward-curved, single-intake with housing Technical description Weight 3.2 kg Fan size 225 mm Rotor surface Painted black Impeller material PA plastic Housing material PA plastic Number of blades 7 Direction of rotation Clockwise, viewed toward rotor Degree of protection IP44; installation- and position-dependent as per EN 60034-5 Insulation class "F" Moisture (F) / Environmental (H) protection class H0+ Max. permitted ambient temp. for motor (transport/storage) + 80 °C Min. permitted ambient temp. for motor (transport/storage) - 40 °C Installation position Shaft horizontal or rotor on bottom; rotor on top on request Condensation drainage holes On rotor side Mode S1 Motor bearing Ball bearing Touch current according to IEC 60990 (measuring circuit Fig. 4, TN system) < 0.75 mA Electrical hookup With plug Motor protection Thermal overload protector (TOP) internally connected With cable Variable Protection class I (with customer connection of protective earth) Conformity with standards EN 60335-1; CE Approval CCC; UL 2111; CSA C22.2 No. 77 Item no. 11022-5-9980 · ENU · Change 85808 · Approved 2016-09-14 · Page 2 / 6 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com K2E225-RA40-02 AC centrifugal module - RadiCal backward-curved, single-intake with housing Product drawing 1 tyco coded plug system 4-pole connector housing tyco 926305-7 4x plug pin tyco 926 885-1 Mating connector (not included in scope of delivery): 4-pole connector housing tyco 926298-6 4x socket tyco 926 884-1 1.1 PE 1.2 L 1.3 N + capacitor 1.4 Capacitor (capacitor not included in scope of delivery) 2 Mounting dimensions Item no. 11022-5-9980 · ENU · Change 85808 · Approved 2016-09-14 · Page 3 / 6 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com AC centrifugal module - RadiCal K2E225-RA40-02 backward-curved, single-intake with housing Connection diagram U1 blue PE green/yellow Z brown U2 black Item no. 11022-5-9980 · ENU · Change 85808 · Approved 2016-09-14 · Page 4 / 6 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com AC centrifugal module - RadiCal K2E225-RA40-02 backward-curved, single-intake with housing Curves: Air performance 50 Hz Druck p f s[Pa]für Rho=1,2kg/m^3 100 200 qv[cfm] 400 300 500 600 700 800 580 2,3 560 2,2 540 520 2,1 500 2 480 4 Air performance measured according to ISO 5801 installation category A. For detailed information on the measurement setup, contact ebm-papst. Intake sound level: Sound power level according to ISO 13347 / sound pressure level measured at 1 m distance from fan axis. The values given are valid under the specified measuring conditions and may vary due to conditions of installation. For deviations from the standard configuration, the parameters have to be checked on the installed unit. 1,8 440 420 1,7 400 1,6 380 1,5 3 360 1,4 340 320 1,3 300 1,2 280 1,1 260 1 240 0,9 220 2 200 0,8 180 0,7 160 0,6 140 120 0,5 100 0,4 80 0,3 60 0,2 ] [Pa pf s 40 20 0 Measurement: LU-128358-1 1,9 460 pf s[Pa] 2,4 p fs_E[IN H2O] 600 0 0,1 1 0 100 200 300 400 500 600 700 800 qv[m^3/h] 900 1.000 1.100 1.200 1.300 0 1.400 Measured values U f n Pe I LpAin LwAin qV pfs qV pfs V Hz min-1 W A dB(A) dB(A) m3/h Pa cfm inH2O 1 115 50 2660 130 1.30 66 74 1180 0 695 0.00 2 115 50 2575 158 1.42 63 70 945 200 555 0.80 3 115 50 2550 165 1.47 62 69 680 350 400 1.41 4 115 50 2630 148 1.35 64 72 390 450 230 1.81 U = Power supply · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · LpAin = Sound pressure level intake side · LwAin = Sound power level intake side qV = Air flow · pfs = Pressure increase Item no. 11022-5-9980 · ENU · Change 85808 · Approved 2016-09-14 · Page 5 / 6 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com AC centrifugal module - RadiCal K2E225-RA40-02 backward-curved, single-intake with housing Curves: Air performance 60 Hz Druck p f s[Pa]für Rho=1,2kg/m^3 qv[cfm] 0 100 200 300 400 500 600 700 800 800 3,2 3,1 750 3 2,9 700 Measurement: LU-128357-1 2,8 2,7 650 Air performance measured according to ISO 5801 installation category A. For detailed information on the measurement setup, contact ebm-papst. Intake sound level: Sound power level according to ISO 13347 / sound pressure level measured at 1 m distance from fan axis. The values given are valid under the specified measuring conditions and may vary due to conditions of installation. For deviations from the standard configuration, the parameters have to be checked on the installed unit. 2,6 2,5 600 2,4 2,3 4 550 2,2 2,1 500 2 1,8 1,7 400 1,6 1,5 350 p fs_E[IN H2O] 450 pf s[Pa] 1,9 3 1,4 1,3 2 300 1,2 1,1 250 1 0,9 200 0,8 0,7 150 0,6 0,5 100 0,4 0,3 50 ] [Pa pf s 0 0,2 1 0 100 200 300 400 500 600 700 800 qv[m^3/h] 900 1.000 1.100 1.200 1.300 1.400 0,1 0 1.500 Measured values U f n Pe I LpAin LwAin qV pfs qV pfs V Hz min-1 W A dB(A) dB(A) m3/h Pa cfm inH2O 1 115 60 3025 187 1.61 69 76 1340 0 790 0.00 2 115 60 2700 225 1.95 62 70 900 300 530 1.20 3 115 60 2765 218 1.89 61 69 650 450 385 1.81 4 115 60 2890 204 1.76 64 71 435 550 255 2.21 U = Power supply · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · LpAin = Sound pressure level intake side · LwAin = Sound power level intake side qV = Air flow · pfs = Pressure increase Item no. 11022-5-9980 · ENU · Change 85808 · Approved 2016-09-14 · Page 6 / 6 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
K2E225-RA40-02 价格&库存

很抱歉,暂时无法提供与“K2E225-RA40-02”相匹配的价格&库存,您可以联系我们找货

免费人工找货