AC centrifugal fan
R2E140-AS77-05
forward curved
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2 · D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
Limited partnership · Headquarters Mulfingen
County court Stuttgart · HRA 590344
General partner: Elektrobau Mulfingen GmbH · Headquarters Mulfingen
County court Stuttgart · HRB 590142
Nominal data
Type
R2E140-AS77-05
Motor
M2E068-BF
Phase
1~
1~
Nominal voltage
VAC
230
230
Frequency
Hz
50
60
Type of data definition
fa
fa
Valid for approval / standard
CE
CE
Speed
min-1
1500
1400
Power input
W
100
110
Current draw
A
0.45
0.48
Motor capacitor
µF
2
2
Capacitor voltage
VDB
450
450
Capacitor standard
P0 (CE)
P0 (CE)
Min. back pressure
Pa
0
0
Max. ambient temperature
°C
40
30
ml = max. load · me = max. efficiency · fa = running at free air · cs = customer specs · cu = customer unit
Subject to alterations
Item no.: 11080-5-9980 · Revision: 72138 · Print-out: 2012-02-09 · Y. Uhlmann (VM-TDO) · Page 1 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC centrifugal fan
R2E140-AS77-05
forward curved
Technical features
Mass
1.1 kg
Size
140 mm
Material of impeller
PP-TV40 plastic
Direction of rotation
Clockwise, seen on rotor
Type of protection
IP 44; Depending on installation and position
Insulation class
"B"
Humidity class
F0
Max. permissible ambient
motor temp. (transp./ storage)
+ 80 °C
Min. permissible ambient
motor temp. (transp./storage)
- 40 °C
Mounting position
Any
Condensate discharge holes
None
Operation mode
S1
Motor bearing
Ball bearing
Leakage current
< 0.75 mA
Motor protection
Thermal overload protector (TOP) wired internally
Cable exit
Variable
Protection class
I (if protective earth is connected by customer)
Product conforming to
standard
EN 60335-1; CE
Approval
CCC
Item no.: 11080-5-9980 · Revision: 72138 · Print-out: 2012-02-09 · Y. Uhlmann (VM-TDO) · Page 2 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC centrifugal fan
R2E140-AS77-05
forward curved
Product drawing
1
Accessory part: Inlet nozzle 09576-2-4013, not included in the standard scope of delivery
2
Depth of screw max. 5 mm
3
Connection line PVC 4G 0.5mm², 4x brass lead tips crimped
Connection screen
U1
blue
PE
green/yellow
Z
brown
U2
black
Item no.: 11080-5-9980 · Revision: 72138 · Print-out: 2012-02-09 · Y. Uhlmann (VM-TDO) · Page 3 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC centrifugal fan
R2E140-AS77-05
forward curved
Charts: Air flow 50 Hz
Druck p sf[Pa]für Rho=1,2kg/m^3
qv[cfm]
400
0
50
100
150
200
250
1,6
1,55
380
1,5
1,45
360
1,4
340
1,3
320
1,25
4
300
1,2
1,15
280
1,1
260
1,05
3
1
240
0,9
p sf _E[IN H2O]
0,95
220
psf[Pa]
Measurement: LU-4523
1,35
0,85
200
0,8
Air performance measured as per ISO 5801
Installation category A. For detailed
information on the measuring set-up, please
contact ebm-papst. Suction-side noise
levels: LwA measured as per ISO 13347 /
LpA measured with 1m distance to fan axis.
The values given are valid under the
measuring conditions mentioned above and
may vary according to the actual installation
situation. With any deviation from the
standard set-up, the specific values have to
be checked and reviewed with the unit
installed.
0,75
180
0,7
0,65
160
0,6
2
140
0,55
0,5
120
0,45
100
0,4
0,35
80
0,3
0,25
60
0,2
40
0,15
1
a]
0
P
ps f[
20
0
20
40
60
80
100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420
qv[m^3/h]
0,1
0,05
0
Measured values
U
f
n
Pe
I
qv
psf
V
Hz
min-1
W
A
m3/h
Pa
1
230
50
1500
100
0.45
405
0
2
230
50
1880
94
0.41
335
140
3
230
50
2175
86
0.38
250
250
4
230
50
2410
78
0.35
155
300
Item no.: 11080-5-9980 · Revision: 72138 · Print-out: 2012-02-09 · Y. Uhlmann (VM-TDO) · Page 4 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC centrifugal fan
R2E140-AS77-05
forward curved
Charts: Air flow 60 Hz
Druck p sf[Pa]für Rho=1,2kg/m^3
540
0
20
40
60
80
100
qv[cfm]
120
140
160
180
200
220
520
2,1
500
2
480
1,9
Measurement: LU-4526
460
1,8
440
1,7
420
4
400
1,6
380
1,5
360
1,4
340
3
psf[Pa]
300
1,2
280
1,1
260
1
240
220
0,9
200
0,8
180
0,7
160
2
0,6
140
120
0,5
100
0,4
80
0,3
60
0,2
40
]
[Pa
ps f
20
0
p sf _E[IN H2O]
1,3
320
Air performance measured as per ISO 5801
Installation category A. For detailed
information on the measuring set-up, please
contact ebm-papst. Suction-side noise
levels: LwA measured as per ISO 13347 /
LpA measured with 1m distance to fan axis.
The values given are valid under the
measuring conditions mentioned above and
may vary according to the actual installation
situation. With any deviation from the
standard set-up, the specific values have to
be checked and reviewed with the unit
installed.
0,1
1
0
20
40
60
80
0
100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400
qv[m^3/h]
Measured values
U
f
n
Pe
I
qv
psf
V
Hz
min-1
W
A
m3/h
Pa
1
230
60
1400
110
0.48
365
0
2
230
60
1840
108
0.47
300
150
3
230
60
2420
101
0.44
205
300
4
230
60
2755
94
0.41
130
400
Item no.: 11080-5-9980 · Revision: 72138 · Print-out: 2012-02-09 · Y. Uhlmann (VM-TDO) · Page 5 / 5