AC centrifugal fan
R4E280-AD12-15
backward-curved, single-intake
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2 · D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
Limited partnership · Headquarters Mulfingen
Amtsgericht (court of registration) Stuttgart · HRA 590344
General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen
Amtsgericht (court of registration) Stuttgart · HRB 590142
Nominal data
Type
R4E280-AD12-15
Motor
M4E068-DF
Phase
1~
1~
Nominal voltage
VAC
115
115
Frequency
Hz
60
60
Method of obtaining data
fa
fa
Valid for approval/standard
UL 1004-3 CE
Speed (rpm)
min-1
1630
1630
Power consumption
W
115
105
Current draw
A
1.05
0.93
Capacitor
µF
10
10
Capacitor voltage
VDB
250
250
Capacitor standard
UL
S0 (CE)
Min. back pressure
Pa
0
0
Min. back pressure
in. wg
0
0
Min. ambient temperature
°C
-25
-25
Max. ambient temperature
°C
30
30
Starting current
A
1.6
1.5
ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment
Subject to change
Item no. 16753-5-9980 · ENU · Change 200952 · Approved 2019-06-04 · Page 1 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC centrifugal fan
R4E280-AD12-15
backward-curved, single-intake
Technical description
Weight
2.9 kg
Size
280 mm
Motor size
68
Rotor surface
Painted black
Impeller material
Sheet steel, painted black
Number of blades
11
Direction of rotation
Clockwise, viewed toward rotor
Degree of protection
IP44; installation- and position-dependent as per EN 60034-5
Insulation class
"B"
Moisture (F) / Environmental (H)
protection class
H1
Max. permitted ambient temp.
for motor (transport/storage)
+ 80 °C
Min. permitted ambient temp. for
motor (transport/storage)
- 40 °C
Installation position
Shaft horizontal or rotor on bottom; rotor on top on request
Condensation drainage holes
On rotor side
Mode
S1
Motor bearing
Ball bearing
Touch current according to IEC
60990 (measuring circuit Fig. 4,
TN system)
< 0.75 mA
Motor protection
Thermal overload protector (TOP) internally connected
With cable
Variable
Protection class
I (with customer connection of protective earth)
Conformity with standards
EN 60335-1; CE
Approval
UL 1004-3
Item no. 16753-5-9980 · ENU · Change 200952 · Approved 2019-06-04 · Page 2 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R4E280-AD12-15
AC centrifugal fan
backward-curved, single-intake
Product drawing
1
Accessory part: inlet ring 96360-2-4013 not included in scope of delivery
2
Max. clearance for screw 5 mm
3
Cable PVC AWG20, 4x crimped splices
Item no. 16753-5-9980 · ENU · Change 200952 · Approved 2019-06-04 · Page 3 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC centrifugal fan
R4E280-AD12-15
backward-curved, single-intake
Accessory part
Accessory part: inlet ring 96360-2-4013 not included in scope of delivery
Connection diagram
U1
blue
PE
green/yellow
Z
brown
U2
black
Item no. 16753-5-9980 · ENU · Change 200952 · Approved 2019-06-04 · Page 4 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC centrifugal fan
R4E280-AD12-15
backward-curved, single-intake
Pa
in. wg
250
1
Curves: Air performance 60 Hz
ρ = 1.15 kg/m³ ± 2 %
Measurement: LU-33556-1
0.6
100
Air performance measured according to ISO
5801 installation category A. For detailed
information on the measurement setup,
contact ebm-papst. Intake sound level:
Sound power level according to ISO 13347 /
sound pressure level measured at 1 m
distance from fan axis. The values given are
valid under the specified measuring
conditions and may vary due to conditions of
installation. For deviations from the standard
configuration, the parameters have to be
checked on the installed unit.
4
0.8
150
0.4
200
3
pfs
50
0.2
2
0
200
qv
400
400
600
800
11000
800
1200
1600
cfm
m³/h
Measured values
Wired
U
f
n
Pe
I
qV
pfs
qV
pfs
V
Hz
min-1
W
A
m3/h
Pa
cfm
in. wg
1
1~
115
60
1630
105
0.93
1640
0
965
0.00
2
1~
115
60
1565
120
1.04
1295
80
765
0.32
3
1~
115
60
1500
127
1.10
905
150
535
0.60
4
1~
115
60
1535
122
1.06
585
200
345
0.80
Wired = Wiring · U = Voltage · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · qV = Air flow · pfs = Pressure increase