Nominal data
Type
W4D300-DT04-09
Motor
M4D068-DF
Phase
Nominal voltage
VAC
Wiring
Frequency
Hz
Method of obtaining data
Valid for approval/standard
3~
3~
3~
3~
3~
230
230
400
400
460
Δ
Δ
Y
Y
Y
50
60
50
60
60
ml
ml
ml
ml
ml
CE
CE
CE
CE
CE
Speed (rpm)
min-1
1350
1530
1350
1530
1600
Power consumption
W
65
90
65
90
100
Current draw
A
0.28
0.29
0.16
0.17
0.17
Max. back pressure
Pa
60
75
60
75
80
Max. back pressure
in. wg
0.24
0.3
0.24
0.3
0.32
Min. ambient temperature
°C
-25
-25
-25
-25
-25
Max. ambient temperature
°C
70
70
70
70
70
ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment
Subject to change
Item no. 16471-5-9980 · ENU · Change 92090 · Approved 2018-09-10 · Page 1 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC axial fan - HyBlade
W4D300-DT04-09
sickle-shaped blades (S series), single-intake
Fan housing with guard grille
Technical description
Weight
3 kg
Size
300 mm
Motor size
68
Rotor surface
Painted black
Blade material
PP plastic
Fan housing material
Sheet steel, galvanized and coated with black plastic (RAL 9005)
Guard grille material
Steel, coated with black plastic (RAL 9005)
Number of blades
5
Airflow direction
V
Direction of rotation
Counterclockwise, viewed toward rotor
Degree of protection
IP44; installation- and position-dependent as per EN 60034-5
Insulation class
"F"
Moisture (F) / Environmental (H)
protection class
H1
Max. permitted ambient temp.
for motor (transport/storage)
+ 80 °C
Min. permitted ambient temp. for
motor (transport/storage)
- 40 °C
Installation position
Shaft horizontal or rotor on bottom; rotor on top on request
Condensation drainage holes
On rotor side
Mode
S1
Motor bearing
Ball bearing
Touch current according to IEC
60990 (measuring circuit Fig. 4,
TN system)
< 0.75 mA
Motor protection
Thermal overload protector (TOP) with basic insulation
With cable
Lateral
Protection class
I (with customer connection of protective earth)
Conformity with standards
EN 60335-1
Approval
UL 1004-1; CSA C22.2 No. 100
Item no. 16471-5-9980 · ENU · Change 92090 · Approved 2018-09-10 · Page 2 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
W4D300-DT04-09
AC axial fan - HyBlade
sickle-shaped blades (S series), single-intake
Fan housing with guard grille
Product drawing
1
Airflow direction "V"
2
Cable PFA AWG20, 9x crimped ferrules
Item no. 16471-5-9980 · ENU · Change 92090 · Approved 2018-09-10 · Page 3 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC axial fan - HyBlade
W4D300-DT04-09
sickle-shaped blades (S series), single-intake
Fan housing with guard grille
Connection diagram
Note: Change of rotation direction by reversing two phases
Δ
Delta connection
Y
Star connection
L1
black
L2
blue
L3
brown
U1
black
V1
blue
W1
brown
U2
green
V2
white
W2
yellow
TOP
2x gray
PE
green/yellow
Item no. 16471-5-9980 · ENU · Change 92090 · Approved 2018-09-10 · Page 4 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC axial fan - HyBlade
W4D300-DT04-09
sickle-shaped blades (S series), single-intake
Fan housing with guard grille
50
in. wg
4
ρ = 1.178 kg/m³ ± 2 %
0.2
Pa
Curves: Air performance 50 Hz
Measurement: LU-141395-1
Air performance measured according to ISO
5801 installation category A. For detailed
information on the measurement setup,
contact ebm-papst. Intake sound level:
Sound power level according to ISO 13347 /
sound pressure level measured at 1 m
distance from fan axis. The values given are
valid under the specified measuring
conditions and may vary due to conditions of
installation. For deviations from the standard
configuration, the parameters have to be
checked on the installed unit.
3
0.15
40
0.1
30
2
0
pfs
10
0.05
20
200
qv
400
400
600
800
800
1200
1000
1600
1cfm
m³/h
Measured values
Wired
U
f
n
Pe
I
LpAin
LwAin
qV
pfs
qV
pfs
V
Hz
min-1
W
A
dB(A)
dB(A)
m3/h
Pa
cfm
in. wg
1
Y
400
50
1410
52
0.15
53
60
1805
0
1065
0.00
2
Y
400
50
1395
57
0.15
52
59
1575
20
925
0.08
3
Y
400
50
1385
60
0.15
51
59
1350
40
795
0.16
4
Y
400
50
1350
65
0.16
55
62
1090
60
640
0.24
Wired = Wiring · U = Voltage · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · LpAin = Sound pressure level intake side · LwAin = Sound power level intake side
qV = Air flow · pfs = Pressure increase
Item no. 16471-5-9980 · ENU · Change 92090 · Approved 2018-09-10 · Page 5 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC axial fan - HyBlade
W4D300-DT04-09
sickle-shaped blades (S series), single-intake
Fan housing with guard grille
in. wg
0.35
Pa
Curves: Air performance 60 Hz
4
80
0.3
Measurement: LU-141399-1
Measurement: LU-141397-1
0.15
3
62
0.1
40
Air performance measured according to ISO
5801 installation category A. For detailed
information on the measurement setup,
contact ebm-papst. Intake sound level:
Sound power level according to ISO 13347 /
sound pressure level measured at 1 m
distance from fan axis. The values given are
valid under the specified measuring
conditions and may vary due to conditions of
installation. For deviations from the standard
configuration, the parameters have to be
checked on the installed unit.
0.25
7
0.2
60
ρ = 1.177 kg/m³ ± 2 %
8
0.05
20
pfs
0
200
qv
400
600
500
800
1000
51
1000
1500
cfm
m³/h
Measured values
Wired
U
f
n
Pe
I
LpAin
LwAin
qV
pfs
qV
pfs
V
Hz
min-1
W
A
dB(A)
dB(A)
m3/h
Pa
cfm
in. wg
1
Y
460
60
1650
77
0.15
57
64
2085
0
1225
0.00
2
Y
460
60
1630
84
0.16
56
63
1815
26
1070
0.10
3
Y
460
60
1615
89
0.16
56
63
1550
54
910
0.22
4
Y
460
60
1600
100
0.17
58
65
1210
80
710
0.32
5
Y
400
60
1605
70
0.14
56
63
2035
0
1200
0.00
6
Y
400
60
1580
78
0.15
55
62
1765
25
1040
0.10
7
Y
400
60
1560
82
0.16
55
62
1500
50
880
0.20
8
Y
400
60
1530
90
0.17
56
63
1160
75
685
0.30
Wired = Wiring · U = Voltage · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · LpAin = Sound pressure level intake side · LwAin = Sound power level intake side
qV = Air flow · pfs = Pressure increase
Item no. 16471-5-9980 · ENU · Change 92090 · Approved 2018-09-10 · Page 6 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
很抱歉,暂时无法提供与“RLF100-11/18”相匹配的价格&库存,您可以联系我们找货
免费人工找货