0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
RLF100-11/18

RLF100-11/18

  • 厂商:

    EBMPAPST(依必安派特)

  • 封装:

  • 描述:

    风扇 离心式鼓风机 48VDC 方形/圆形 - 127mm 长 x 127mm 高 滚珠 37.7 CFM(1.06m³/min) 2 引线

  • 数据手册
  • 价格&库存
RLF100-11/18 数据手册
AC axial fan - HyBlade W4D300-DT04-09 sickle-shaped blades (S series), single-intake Fan housing with guard grille ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 · D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership · Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart · HRA 590344 General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart · HRB 590142 Nominal data Type W4D300-DT04-09 Motor M4D068-DF Phase Nominal voltage VAC Wiring Frequency Hz Method of obtaining data Valid for approval/standard 3~ 3~ 3~ 3~ 3~ 230 230 400 400 460 Δ Δ Y Y Y 50 60 50 60 60 ml ml ml ml ml CE CE CE CE CE Speed (rpm) min-1 1350 1530 1350 1530 1600 Power consumption W 65 90 65 90 100 Current draw A 0.28 0.29 0.16 0.17 0.17 Max. back pressure Pa 60 75 60 75 80 Max. back pressure in. wg 0.24 0.3 0.24 0.3 0.32 Min. ambient temperature °C -25 -25 -25 -25 -25 Max. ambient temperature °C 70 70 70 70 70 ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment Subject to change Item no. 16471-5-9980 · ENU · Change 92090 · Approved 2018-09-10 · Page 1 / 6 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com AC axial fan - HyBlade W4D300-DT04-09 sickle-shaped blades (S series), single-intake Fan housing with guard grille Technical description Weight 3 kg Size 300 mm Motor size 68 Rotor surface Painted black Blade material PP plastic Fan housing material Sheet steel, galvanized and coated with black plastic (RAL 9005) Guard grille material Steel, coated with black plastic (RAL 9005) Number of blades 5 Airflow direction V Direction of rotation Counterclockwise, viewed toward rotor Degree of protection IP44; installation- and position-dependent as per EN 60034-5 Insulation class "F" Moisture (F) / Environmental (H) protection class H1 Max. permitted ambient temp. for motor (transport/storage) + 80 °C Min. permitted ambient temp. for motor (transport/storage) - 40 °C Installation position Shaft horizontal or rotor on bottom; rotor on top on request Condensation drainage holes On rotor side Mode S1 Motor bearing Ball bearing Touch current according to IEC 60990 (measuring circuit Fig. 4, TN system) < 0.75 mA Motor protection Thermal overload protector (TOP) with basic insulation With cable Lateral Protection class I (with customer connection of protective earth) Conformity with standards EN 60335-1 Approval UL 1004-1; CSA C22.2 No. 100 Item no. 16471-5-9980 · ENU · Change 92090 · Approved 2018-09-10 · Page 2 / 6 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com W4D300-DT04-09 AC axial fan - HyBlade sickle-shaped blades (S series), single-intake Fan housing with guard grille Product drawing 1 Airflow direction "V" 2 Cable PFA AWG20, 9x crimped ferrules Item no. 16471-5-9980 · ENU · Change 92090 · Approved 2018-09-10 · Page 3 / 6 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com AC axial fan - HyBlade W4D300-DT04-09 sickle-shaped blades (S series), single-intake Fan housing with guard grille Connection diagram Note: Change of rotation direction by reversing two phases Δ Delta connection Y Star connection L1 black L2 blue L3 brown U1 black V1 blue W1 brown U2 green V2 white W2 yellow TOP 2x gray PE green/yellow Item no. 16471-5-9980 · ENU · Change 92090 · Approved 2018-09-10 · Page 4 / 6 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com AC axial fan - HyBlade W4D300-DT04-09 sickle-shaped blades (S series), single-intake Fan housing with guard grille 50 in. wg 4 ρ = 1.178 kg/m³ ± 2 % 0.2 Pa Curves: Air performance 50 Hz Measurement: LU-141395-1 Air performance measured according to ISO 5801 installation category A. For detailed information on the measurement setup, contact ebm-papst. Intake sound level: Sound power level according to ISO 13347 / sound pressure level measured at 1 m distance from fan axis. The values given are valid under the specified measuring conditions and may vary due to conditions of installation. For deviations from the standard configuration, the parameters have to be checked on the installed unit. 3 0.15 40 0.1 30 2 0 pfs 10 0.05 20 200 qv 400 400 600 800 800 1200 1000 1600 1cfm m³/h Measured values Wired U f n Pe I LpAin LwAin qV pfs qV pfs V Hz min-1 W A dB(A) dB(A) m3/h Pa cfm in. wg 1 Y 400 50 1410 52 0.15 53 60 1805 0 1065 0.00 2 Y 400 50 1395 57 0.15 52 59 1575 20 925 0.08 3 Y 400 50 1385 60 0.15 51 59 1350 40 795 0.16 4 Y 400 50 1350 65 0.16 55 62 1090 60 640 0.24 Wired = Wiring · U = Voltage · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · LpAin = Sound pressure level intake side · LwAin = Sound power level intake side qV = Air flow · pfs = Pressure increase Item no. 16471-5-9980 · ENU · Change 92090 · Approved 2018-09-10 · Page 5 / 6 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com AC axial fan - HyBlade W4D300-DT04-09 sickle-shaped blades (S series), single-intake Fan housing with guard grille in. wg 0.35 Pa Curves: Air performance 60 Hz 4 80 0.3 Measurement: LU-141399-1 Measurement: LU-141397-1 0.15 3 62 0.1 40 Air performance measured according to ISO 5801 installation category A. For detailed information on the measurement setup, contact ebm-papst. Intake sound level: Sound power level according to ISO 13347 / sound pressure level measured at 1 m distance from fan axis. The values given are valid under the specified measuring conditions and may vary due to conditions of installation. For deviations from the standard configuration, the parameters have to be checked on the installed unit. 0.25 7 0.2 60 ρ = 1.177 kg/m³ ± 2 % 8 0.05 20 pfs 0 200 qv 400 600 500 800 1000 51 1000 1500 cfm m³/h Measured values Wired U f n Pe I LpAin LwAin qV pfs qV pfs V Hz min-1 W A dB(A) dB(A) m3/h Pa cfm in. wg 1 Y 460 60 1650 77 0.15 57 64 2085 0 1225 0.00 2 Y 460 60 1630 84 0.16 56 63 1815 26 1070 0.10 3 Y 460 60 1615 89 0.16 56 63 1550 54 910 0.22 4 Y 460 60 1600 100 0.17 58 65 1210 80 710 0.32 5 Y 400 60 1605 70 0.14 56 63 2035 0 1200 0.00 6 Y 400 60 1580 78 0.15 55 62 1765 25 1040 0.10 7 Y 400 60 1560 82 0.16 55 62 1500 50 880 0.20 8 Y 400 60 1530 90 0.17 56 63 1160 75 685 0.30 Wired = Wiring · U = Voltage · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · LpAin = Sound pressure level intake side · LwAin = Sound power level intake side qV = Air flow · pfs = Pressure increase Item no. 16471-5-9980 · ENU · Change 92090 · Approved 2018-09-10 · Page 6 / 6 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
RLF100-11/18 价格&库存

很抱歉,暂时无法提供与“RLF100-11/18”相匹配的价格&库存,您可以联系我们找货

免费人工找货