W2S130-AA03-87

W2S130-AA03-87

  • 厂商:

    EBMPAPST(依必安派特)

  • 封装:

    插件

  • 描述:

    FAN AXIAL 172X55MM 230VAC WIRE

  • 数据手册
  • 价格&库存
W2S130-AA03-87 数据手册
AC axial compact fan W2S130-AA03-87 sickled blades (S series) ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 · D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership · Headquarters Mulfingen County court Stuttgart · HRA 590344 General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen County court Stuttgart · HRB 590142 Nominal data Type W2S130-AA03-87 Motor M2S052-CA Phase 1~ 1~ Nominal voltage VAC 230 230 Frequency Hz 50 60 Type of data definition fa fa Valid for approval / standard CE CE Speed min-1 2800 3250 Power input W 45 39 Current draw A 0.31 0.25 Max. back pressure Pa 80 120 Max. ambient temperature °C 50 70 Starting current A 0.45 0.40 ml = max. load · me = max. efficiency · fa = running at free air · cs = customer specs · cu = customer unit Subject to alterations Item no. 10431-5-9980 · Revision 66668 · Release 2011-06-29 · Page 1 / 6 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com AC axial compact fan W2S130-AA03-87 sickled blades (S series) Technical features Mass 1.05 kg Size 130 mm Surface of rotor Rotor open, coated in black Material of blades Sheet steel, coated in black Material of wall ring Die-cast aluminium, coated in black Number of blades 7 Direction of air flow "V" Direction of rotation Counter-clockwise, seen on rotor Type of protection IP 20 Insulation class "B" Max. permissible ambient motor temp. (transp./ storage) + 80 °C Min. permissible ambient motor temp. (transp./storage) - 40 °C Mounting position Any Condensate discharge holes None Operation mode S1 Motor bearing Ball bearing Touch current acc. IEC 60990 (measuring network Fig. 4, TN system) < 0.75 mA Motor protection Thermal overload protector (TOP) wired internally Protection class I (if protective earth is connected by customer) Product conforming to standard CE Approval CCC; UL 507; CSA C22.2 Nr.113 Item no. 10431-5-9980 · Revision 66668 · Release 2011-06-29 · Page 2 / 6 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com W2S130-AA03-87 AC axial compact fan sickled blades (S series) Product drawing 1 Connecting cable AWG 26, tin-plated 6mm lead tips 2 Connection line AWG20, 2x brass lead tips crimped Item no. 10431-5-9980 · Revision 66668 · Release 2011-06-29 · Page 3 / 6 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com W2S130-AA03-87 AC axial compact fan sickled blades (S series) Connection screen 1 Fan connection diagram TOP Thermal overload protector L black N black 2 Hall IC circuit 3 Hall IC 4 Red (+5V) 5 White (out) 6 Black (0V) Item no. 10431-5-9980 · Revision 66668 · Release 2011-06-29 · Page 4 / 6 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com AC axial compact fan W2S130-AA03-87 sickled blades (S series) Charts: Air flow 50 Hz Druck p f s[Pa]für Rho=1,2kg/m^3 20 40 60 80 100 qv[cfm] 120 140 160 180 200 220 0,68 165 0,66 160 0,64 155 0,62 150 0,6 145 0,58 140 0,56 135 0,54 130 0,52 125 0,5 120 0,48 115 0,46 110 0,44 105 0,42 100 0,4 95 0,38 90 0,36 85 0,34 80 0,32 75 0,3 70 0,28 65 0,24 55 0,22 50 0,2 45 0,18 3 40 0,16 35 0,14 30 0,12 25 0,1 2 20 0,08 15 0,06 0,04 ] [Pa pf s 10 5 0 Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. 0,26 4 60 Measurement: LU-58475 p fs_E[IN H2O] pf s[Pa] 170 0 0,02 1 0 20 40 60 80 100 120 140 160 180 200 qv[m^3/h] 220 240 260 280 300 320 340 360 0 380 Measured values U f n Pe I qv pfs V Hz min-1 W A m3/h Pa 1 230 50 2800 45 0.31 340 0 2 230 50 2795 45 0.31 310 20 3 230 50 2780 46 0.31 270 40 4 230 50 2780 46 0.31 190 59 U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · qv = Air flow · pfs = Pressure increase Item no. 10431-5-9980 · Revision 66668 · Release 2011-06-29 · Page 5 / 6 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com AC axial compact fan W2S130-AA03-87 sickled blades (S series) Charts: Air flow 60 Hz Druck p f s[Pa]für Rho=1,2kg/m^3 qv[cfm] 50 100 150 200 250 175 0,7 0,68 170 165 0,66 160 0,64 0,62 155 150 145 140 0,58 0,56 135 0,54 130 0,52 0,5 0,48 115 0,46 0,44 110 105 100 0,42 95 0,4 0,38 90 0,36 85 80 75 0,34 0,32 4 Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. 0,3 70 0,28 0,26 65 60 55 0,24 0,22 0,2 3 50 45 0,18 40 0,16 0,14 35 30 0,12 2 25 0,1 0,08 20 0,06 ] [Pa pf s 15 10 5 0 Measurement: LU-58476 0,6 125 120 pf s[Pa] 0,72 p fs_E[IN H2O] 180 0 1 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 qv[m^3/h] 0,04 0,02 0 Measured values U f n Pe I qv pfs V Hz min-1 W A m3/h Pa 1 230 60 3250 39 0.25 390 0 2 230 60 3200 42 0.25 355 25 3 230 60 3165 43 0.26 305 50 4 230 60 3170 43 0.26 200 75 U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · qv = Air flow · pfs = Pressure increase Item no. 10431-5-9980 · Revision 66668 · Release 2011-06-29 · Page 6 / 6 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
W2S130-AA03-87 价格&库存

很抱歉,暂时无法提供与“W2S130-AA03-87”相匹配的价格&库存,您可以联系我们找货

免费人工找货