AC axial fan
W4D400-DP12-41
sickled blades (S series), single inlet
Wall ring with guard grille
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2 · D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
Limited partnership · Headquarters Mulfingen
County court Stuttgart · HRA 590344
General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen
County court Stuttgart · HRB 590142
Nominal data
Type
W4D400-DP12-41
Motor
M4D074-EI
Phase
Nominal voltage
VAC
Connection
Frequency
Hz
Type of data definition
Valid for approval / standard
3~
3~
3~
3~
380
400
400
480
Y
Y
Y
Y
50
50
60
60
fa
fa
fa
fa
CE
CE
CE
CE
Speed
min-1
1430
1450
1690
1640
Power input
W
145
135
185
250
Current draw
A
0.48
0.44
0.39
0.6
Max. back pressure
Pa
130
150
120
130
Min. ambient temperature
°C
-25
-25
-25
-25
Max. ambient temperature
°C
60
60
60
55
Starting current
A
1.7
1.7
1.7
ml = Max. load · me = Max. efficiency · fa = Running at free air · cs = Customer specs · cu = Customer unit
Subject to alterations
Data according to ErP directive
Request 2013
Request 2015
32.7
25.1
29.1
43.6
36
40
A
Overall efficiency ηes
Efficiency category
Static
Efficiency grade N
Variable speed drive
No
Power input Pe
kW
0.19
Specific ratio*
1.00
Air flow qv
m³/h
2595
Pressure increase pfs
Pa
91
Speed n
min-1
1415
*
Specific ratio = 1 + pfs / 100 000 Pa
%
Actual
Installation category
Data definition with optimum efficiency.
LU-27622
The ErP data is determined using a motor-impeller combination in a standardised measurement configuration.
Item no. 13681-5-9980 · Revision 81525 · Release 2014-05-05 · Page 1 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC axial fan
W4D400-DP12-41
sickled blades (S series), single inlet
Wall ring with guard grille
Technical features
Mass
9.4 kg
Size
400 mm
Surface of rotor
Coated in black
Material of blades
Sheet steel, coated in black
Material of wall ring
Sheet steel, galvanised and coated in black plastic (RAL 9005)
Material of guard grille
Steel, coated in black plastic (RAL9005)
Number of blades
5
Direction of air flow
"V"
Direction of rotation
Counter-clockwise, seen on rotor
Type of protection
IP 44; Depending on installation and position as per EN 60034-5
Insulation class
"F"
Humidity class
F2-2
Max. permissible ambient motor
temp. (transp./ storage)
+ 80 °C
Min. permissible ambient motor
temp. (transp./storage)
- 40 °C
Mounting position
Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharge holes
Rotor-side
Operation mode
S1
Motor bearing
Ball bearing
Touch current acc. IEC 60990
(measuring network Fig. 4, TN
system)
< 0.75 mA
Motor protection
Thermal overload protector (TOP) wired internally
Cable exit
Variable
Protection class
I (if protective earth is connected by customer)
Product conforming to standard
CE
Approval
CSA C22.2 Nr.100; UL 1004-1
Item no. 13681-5-9980 · Revision 81525 · Release 2014-05-05 · Page 2 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
W4D400-DP12-41
AC axial fan
sickled blades (S series), single inlet
Wall ring with guard grille
Product drawing
1
Direction of air flow "V"
2
Connection line PFA AWG18, 1x lead tip crimped, connection line PFA AWG20, 3x lead tips crimped
Item no. 13681-5-9980 · Revision 81525 · Release 2014-05-05 · Page 3 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC axial fan
W4D400-DP12-41
sickled blades (S series), single inlet
Wall ring with guard grille
Connection screen
Change direction of rotation by reversing two phases
L2
Three-phase motor
Y
Star connection
L1
= U1 = black
= V1 = blue
L3
= W1 = brown
PE
green / yellow
Item no. 13681-5-9980 · Revision 81525 · Release 2014-05-05 · Page 4 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC axial fan
W4D400-DP12-41
sickled blades (S series), single inlet
Wall ring with guard grille
Charts: Air flow 50 Hz
Druck p f s[Pa]für Rho=1,2kg/m^3
qv[cfm]
270
0
500
1.000
1.500
2.000
2.500
260
1,05
250
1
240
0,95
230
Air performance measured as per ISO 5801
Installation category A. For detailed
information on the measuring set-up, please
contact ebm-papst. Suction-side noise
levels: LwA measured as per ISO 13347 /
LpA measured with 1m distance to fan axis.
The values given are valid under the
measuring conditions mentioned above and
may vary according to the actual installation
situation. With any deviation from the
standard set-up, the specific values have to
be checked and reviewed with the unit
installed.
0,9
220
210
0,85
200
0,8
190
0,75
180
pf s[Pa]
160
0,65
150
0,6
140
0,55
130
0,5
120
0,45
110
4
100
0,4
90
0,35
80
0,3
3
70
0,25
60
50
0,2
40
2
0,15
30
0,1
20
a]
s[P
pf
10
0
p fs_E[IN H2O]
0,7
170
1
0
500
1.000
1.500
2.000
2.500
qv[m^3/h]
3.000
3.500
4.000
0,05
0
Measured values
Conn.
U
f
n
Pe
I
LpAin
LwAin
qv
pfs
V
Hz
min-1
W
A
dB(A)
dB(A)
m3/h
Pa
1
Y
400
50
1450
135
0.44
65
74
4000
0
2
Y
400
50
1435
161
0.47
65
73
3535
35
3
Y
400
50
1420
182
0.49
65
72
2995
70
4
Y
400
50
1410
203
0.50
67
74
2355
100
Conn. = Connection · U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · LpAin = Sound pressure level inlet side · LwAin = Sound power level inlet side
qv = Air flow · pfs = Pressure increase
Item no. 13681-5-9980 · Revision 81525 · Release 2014-05-05 · Page 5 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC axial fan
W4D400-DP12-41
sickled blades (S series), single inlet
Wall ring with guard grille
Charts: Air flow 60 Hz
Druck p f s[Pa]für Rho=1,2kg/m^3
300
0
500
qv[cfm]
1.500
1.000
2.000
2.500
3.000
290
1,15
280
1,1
270
260
1,05
250
1
240
0,9
220
210
0,85
200
0,8
190
0,75
180
p fs_E[IN H2O]
0,7
170
160
0,65
150
0,6
140
0,55
130
4
120
0,5
0,45
110
100
0,4
90
0,35
3
80
0,3
70
0,25
60
50
0,2
2
40
0,15
30
0,1
20
0,05
]
[Pa
pf s
10
0
Air performance measured as per ISO 5801
Installation category A. For detailed
information on the measuring set-up, please
contact ebm-papst. Suction-side noise
levels: LwA measured as per ISO 13347 /
LpA measured with 1m distance to fan axis.
The values given are valid under the
measuring conditions mentioned above and
may vary according to the actual installation
situation. With any deviation from the
standard set-up, the specific values have to
be checked and reviewed with the unit
installed.
0,95
230
pf s[Pa]
1,2
1
0
500
1.000
1.500
2.000
2.500
3.000
qv[m^3/h]
3.500
4.000
4.500
5.000
0
Measured values
Conn.
U
f
n
Pe
I
LpAin
LwAin
qv
pfs
V
Hz
min-1
W
A
dB(A)
dB(A)
m3/h
Pa
1
Y
400
60
1690
185
0.39
69
76
4615
0
2
Y
400
60
1660
223
0.45
70
76
4145
40
3
Y
400
60
1635
256
0.49
69
76
3580
80
4
Y
400
60
1605
290
0.54
70
76
2895
120
Conn. = Connection · U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · LpAin = Sound pressure level inlet side · LwAin = Sound power level inlet side
qv = Air flow · pfs = Pressure increase
Item no. 13681-5-9980 · Revision 81525 · Release 2014-05-05 · Page 6 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com