AC axial fan
W4E400-CP14-70
sickled blades (S series), single inlet
with full round nozzle
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2 · D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
Limited partnership · Headquarters Mulfingen
County court Stuttgart · HRA 590344
General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen
County court Stuttgart · HRB 590142
Nominal data
Type
W4E400-CP14-70
Motor
M4E074-EI
Phase
1~
1~
Nominal voltage
VAC
115
115
Frequency
Hz
60
60
Type of data definition
fa
fa
Valid for approval / standard
CE
UL 2111
Speed
min-1
1680
1680
Power input
W
250
270
Current draw
A
2.19
Motor capacitor
µF
20
20
Capacitor voltage
VDB
220
220
Max. back pressure
Pa
75
75
Min. ambient temperature
°C
-25
-25
Max. ambient temperature
°C
30
30
ml = Max. load · me = Max. efficiency · fa = Running at free air · cs = Customer specs · cu = Customer unit
Subject to alterations
Item no. 14418-5-9980 · Revision 83262 · Release 2014-07-03 · Page 1 / 4
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC axial fan
W4E400-CP14-70
sickled blades (S series), single inlet
with full round nozzle
Technical features
Mass
8.17 kg
Size
400 mm
Surface of rotor
Coated in black
Material of impeller
Sheet steel, coated in black
Material of wall ring
Sheet steel, galvanised and coated in black plastic (RAL 9005)
Material of guard grille
Steel, coated in black plastic (RAL9005)
Direction of air flow
"V"
Direction of rotation
Counter-clockwise, seen on rotor
Type of protection
IP 44; Depending on installation and position as per EN 60034-5
Insulation class
"B"
Humidity class
F1-2
Max. permissible ambient motor
temp. (transp./ storage)
+ 80 °C
Min. permissible ambient motor
temp. (transp./storage)
- 40 °C
Mounting position
Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharge holes
Rotor-side
Operation mode
S1
Motor bearing
Ball bearing
Touch current acc. IEC 60990
(measuring network Fig. 4, TN
system)
< 0.75 mA
Motor protection
Thermal overload protector (TOP) wired internally
Cable exit
Variable
Protection class
I (if protective earth is connected by customer)
Product conforming to standard
EN 60335-1; CE
Approval
UL 2111; CSA C22.2 Nr.77
Item no. 14418-5-9980 · Revision 83262 · Release 2014-07-03 · Page 2 / 4
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC axial fan
W4E400-CP14-70
sickled blades (S series), single inlet
with full round nozzle
Product drawing
1
Direction of air flow "V"
2
Connection line PVC AWG20, 4x lead tips crimped
Connection screen
U1
blue
PE
green/yellow
Z
brown
U2
black
Item no. 14418-5-9980 · Revision 83262 · Release 2014-07-03 · Page 3 / 4
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC axial fan
W4E400-CP14-70
sickled blades (S series), single inlet
with full round nozzle
Charts: Air flow 60 Hz
0
120
500
1000
pfs @ rho=1,2 kg/m³
qv [CFM]
1500
2000
2500
3000
0,48
115
0,46
110
0,44
105
0,42
100
0,4
95
0,38
90
0,36
85
0,34
75
pfs [Pa]
0,32
4
0,3
70
0,28
65
0,26
60
0,24
55
0,22
3
50
0,18
40
0,16
35
0,14
0,12
2
25
Air performance measured as per ISO 5801
Installation category A. For detailed
information on the measuring set-up, please
contact ebm-papst. Suction-side noise
levels: LwA measured as per ISO 13347 /
LpA measured with 1m distance to fan axis.
The values given are valid under the
measuring conditions mentioned above and
may vary according to the actual installation
situation. With any deviation from the
standard set-up, the specific values have to
be checked and reviewed with the unit
installed.
0,2
45
30
pfs [InH2O]
80
0,1
20
0,08
15
0,06
10
0,04
5
0
0
Measurement: LU-33656
1
500
1000
1500
2000
2500
3000
qv [m³/h]
3500
4000
4500
0,02
0
5000
Measured values
U
f
n
Pe
I
qv
pfs
V
Hz
min-1
W
A
m3/h
Pa
1
115
60
1680
250
2.19
4820
0
2
115
60
1660
264
2.30
4530
25
3
115
60
1630
279
2.43
4190
50
4
115
60
1580
297
2.61
3705
75
U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · qv = Air flow · pfs = Pressure increase
Item no. 14418-5-9980 · Revision 83262 · Release 2014-07-03 · Page 4 / 4
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
很抱歉,暂时无法提供与“W4E400-CP14-70”相匹配的价格&库存,您可以联系我们找货