0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BXB100-24S12FLTJ

BXB100-24S12FLTJ

  • 厂商:

    EMERSON-NETWORKPOWER

  • 封装:

  • 描述:

    BXB100-24S12FLTJ - Industry standard footprint - Emerson Network Power

  • 数据手册
  • 价格&库存
BXB100-24S12FLTJ 数据手册
Embedded Power for Business-Critical Continuity BXB100 Series Single output Rev.10.16.08_121 BXB100 Series 1 of 3 Total Power: 66 - 100 W Input Voltage: 18 - 36 V 36 - 75 V # of Outputs: Single Electrical Specifications Input Special Features • Industry standard footprint • High power density (36.5 W/in3) • MTBF >1.4 million hours (Bellcore 332) • Input voltage to ETS300-132-2 • Adjustable output voltage • No minimum load required • Separate case ground pin • Undervoltage lockout (UVLO) • UL, VDE and CSA safety approvals • 2 year warranty Input voltage range: Input current: Input current (max.): (See note 4) Input reflected ripple: Active low remote ON/OFF: Logic compatiblity: ON: OFF: Undervoltage lockout: 24 Vin nominal 48 Vin nominal No load Remote OFF 48 V models (See note 6) 18 - 36 Vdc 36 - 75 Vdc 100 mA max. 20 mA max. 4 A max. @ lo max. and Vin = 0 to 75 V 5 mA pk-pk Start-up time: (see note 8) (See note 7) Open collector ref to -input 1.2 Vdc max. Open circuit 24 Vin: power-up 17 V 24 Vin: power-down 16 V 48 Vin: power-up 34 V 48 Vin: power-down 32.5 V Power up 20 ms Remote ON/OFF 20 ms Low line to high line Full load to min. load At turn on and turn-off 3.3 V and 5 V 12V and 15 V 60% to 110% ±1.0% ±0.05% ±0.10% 0 % None None 75 mV pk-pk, 20 mV rms 100 mV pk-pk, 30 mV rms Output Voltage adjustability: Setpoint accuracy: Line regulation: Load regulation: Minimum load: Overshoot: Safety VDE0805/EN60950/IEC950 UL1950 CSA C22.2 No. 950 Undershoot: Ripple and noise: 5 Hz - 20 MHz (see note 1) Embedded Power for Business-Critical Continuity Output Continued Ripple and noise: 5 Hz - 20 MHz (see note 1) Temperature coefficient: Transient response: (see note 2) Remote Sense: 3.3 V and 5 V 12V and 15 V 75 mV pk-pk, 20 mV rms 100 mV pk-pk, 30 mV rms ±0.01% / ºC Rev.10.16.08_121 BXB100 Series 2 of 3 ±2.0% max. deviation 170 µs recovery to within ±1.0% 0.5 Vds transmission line drop compensation EMC Charateristics Conducted emissions: (see note 3) EN55022 (See note 3) FCC part 15 EN55022, CISPR22 Level A Level A Level A General Specifications Efficiency: Isolation voltage: Input/case Input/output Output/case Fixed Bellcore 332 MIL-HDBK-217F @ 40 °C, 100% load See table 1500 Vdc 1500 Vdc 1500 Vdc 500 kHz typ. VDE0805, EN60950, IEC950 UL1950, CSA C22.2 No. 950 Aluminum baseplate with plastic case UL94V-0 110 g (3.88 oz) 1,400,000 hours 580,000 hours min. Switching frequency: Approvals and standards: (see note 5) Case material: Material flammability: Weight: MTBF: Protection Short-circuit: Overvoltage: Undervoltage: Thermal: Continuous, automatic recovery Non-latching Non-latching 110 °C baseplate, automatic recovery Telecom Specifications Central office interface A: ETS300-132-2 Environmental Specifications Thermal performance: Altitude: Vibration: Operating case temp. Non-operating Operating Non-operating 5 - 500 Hz -40 ºC to +100 ºC -55 ºC to +125 ºC 10,000 feet max. 40,000 feet max. 2.4 G rms (approx.) Embedded Power for Business-Critical Continuity Americas Ordering Information Output Power (Max.) Input Voltage OVP Output Voltage Output Current (Min.) Output Current (Max.) Efficiency (Typ.) Regulation Line Load Model Number 100 W 100 W 100 W 18 - 36 Vdc 36 - 75 Vdc 36 - 75 Vdc 14.5 Vdc 6.5 Vdc 14.5 Vdc 12 V 5 V 12 V 0 A 0 A 0 A 8.33 A 20 A 8.33 A 85% 83% 86% ±0.05% ±0.05% ±0.05% ±0.1% ±0.1% ±0.1% BXB100-24S12FLTJ BXB100-48S05FLTJ BXB100-48S12FLTJ 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Rev.10.16.08_121 BXB100 Series 3 of 3 Europe (UK) External Output Trimming Output can be externally trimmed by using the method shown. 8 8 Notes 1 Measured with 10 µF tantalum capacitor and 1 µF ceramic capacitor across output. 2 di/dt = 0.1 A/1 µs, Vin = 48 Vdc, Tc = 25 °C, load change = 0.5 lo max. to 0.75 lo max. and 0.75 Io max. to 0.5 Io max. 3 Units should be characterised within systems. External components required. 4 Input fusing is recommended based on surge current and maximum input current. 5 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 6 Simulated source impedance of 12 µH. 12 µH inductor in series with +Vin. 7 Active high remote on/off option is available (standard product is active low), designate with the suffix ‘FHT’ e.g. BXB100-48S05FHTJ. Consult factory for further details and options. 8 Start-up into resistive load. 9 “J” suffix designation for RoHS 6/6. Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 TRIM UP 7 TRIM DOWN 6 RT1 OR RT2 7 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon 10K Hong Kong TRIMPOT Telephone: +852 2176 3333 Facsimile: +852 2176 3888 Asia (HK) 6 For global contact, visit: www.powerconversion.com techsupport.embeddedpower @emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Pin Connections Pin Number Function 1 2 3 4 5 6 7 8 9 +Vin Remote ON/OFF Case -Vin -Vout -Sense Trim +Sense +Vout Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Mechanical Drawing VIEW SHOWN PIN SIDE UP 1.90 (48.26) 0.500 (12.69) 0.010 (0.25) CASE Connectivity 0.200 (5.08) Min. Length for all Input and Output Pins DC Power Embedded Computing Embedded Power Monitoring 0.190 (4.83) 0.010 (0.25) +SEN TRIM -SEN 1.000 (25.40) 0.400 (10.16) 1.400 (35.56) Vo (-) VI (-) 0.700 (17.77) 0.400 (10.16) 1.000 (25.40) 2.000 (50.80) 2.40 (60.96) Max. Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services ON/OFF 1.400 (35.56) 7 x Ø.040 (1.02) 0.002 (0.05) 0.190 (4.83) 0.010 (0.25) 2.28 (57.91) Max. 2 x Ø.080 (2.03) 0.002 (0.05) 4 x M3 x 0.5 Through 0.500 (12.70) Vo(+) VI(+) Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co. ALL DIMENSIONS IN INCHES (mm) Tolerance : x.xx 0.02in. (0.51mm) x.xxx 0.010in. (0.254mm)
BXB100-24S12FLTJ 价格&库存

很抱歉,暂时无法提供与“BXB100-24S12FLTJ”相匹配的价格&库存,您可以联系我们找货

免费人工找货