Embedded Power for Business-Critical Continuity
HPS3000 Series
3000 Watts
Distributed Power Bulk Front-End
Single Output
Rev. 7.10.09_81 HPS3000 Series 1 of 7
Special Features
• 3000 W output power • 40 W/cu-in • Optional customer provided air • 1U x 3U form factor • N+1 Redundant • Hot-swap • Internal OR-ing • 5 V housekeeping • High efficiency 89% @ 200 Vac, 100% load • Variable speed “smart fans” • One year warranty
Electrical Specifications
Input
Input range (operating): Input range (nominal): Frequency: Input fusing: Inrush current: Power factor: Harmonics: Input current: Holdup time: Leakage current: 180 - 264 Vac 90 - 140 Vac 200 Vac 110 Vac 43 to 63 Hz Internal 25 A fuses ≤40 A peak 0.97 typical Meets IEC 1000-3-2 requirements 19 A max input current 10 ms minimum 1.4 mA MOV directly after the fuse At full rated load At 240 Vac Input through Card Edge Connection on same end as DC output Both lines fused Either hot or cold start Meets EN61000-3-2 @ 50% load
Compliance
• POE Isolation • EMI Class B - EN55022, Level “A” • EN61000 Immunity
Power line transient:
Safety
• UL/cUL • CSA • China • Nemko • CB Report • CSA 22.2 60950 60950 CCC TUV 60950
Embedded Power for Business-Critical Continuity
2 30V ac E ffi c i en c y
230 Vac Efficiency
100.00 90.0 0 80.0 0 70.0 0 60.0 0 50.0 0 40.0 0 30.0 0 20.0 0 10.0 0 10 20 30 40 50 60 70 80 90 10 0
% o f T o t al O u t p u t P o w e r
Rev. 7.10.09_81 HPS3000 Series of 7
Output
Output rating 48 V @ 62.0 A 5 Vsb @ 3.0 A 48 V @ 29.4 A 5V @ 3 A 48 V 48 V ± 10% 5 Vsb ± 4% 3000 W maximum @ 200 Vac Input 1500 W maximum @ 110 Vac Input 48 V @ 0.0 A 5 Vsb @ 0.0 A 480 mV max P-P 100 mV max P-P ± 5% maximum 5% maximum deviation 180 - 264 Vac 90 - 140 Vac Programmable ±10% through I2C serial bus Line/load/transient when measured at output connection No derating over operating temp range No loss of regulation 48 V output 5 Vsb output Measured with a 0.1µF Ceramic and 10 µF Tantalum capacitor on any input Nominal Voltage Setting 50% load step @ 1 A/us Step load valid between 10% to 100% of output rating. Total power in 1U 19” rack is 12 KW Output to return >2000 Vac Digital sharing control 48 V output 5 Vsb output 48 V output 5 Vsb output Both PFC and output converter monitored 5 Vsb will operate under overtemperature condition. Built in hysteresis
Set point Total regulation range Rated load Minimum load Output noise
Output voltage overshoot Transient response Max units in parallel Short circuit protection Output isolation Forced load sharing Over current protection (OCP)
Up to 4 120% - 130% of rated output Per POE specs Within 10% of all shared outputs 120% to 130% 100% to 125% Over voltage protection (OVP) 110% to 120% 110% to 125% Over temperature protection 10 - 15 deg C above safe operating area
Environmental Specifications
Vibration/Shock: Operating temperature: Storage Temperature: Cooling Operating Relative Humidity: Storage Relative Humidity: Operating Altitude Storage Altitude: RoHS Compliant: Non-operational 5G Sine sweep from 5 Hz to 500 Hz, dwelling at resonant frequencies for 1 hour each -10 ° to +40 °C -40 ° to +85 °C External fans with Fan Fail and Fan Speed control 5% to 95% non-condensing 5% to 95% non-condensing Up to 10,000 feet above sea level Up to 30,000 feet above sea level Yes
Embedded Embedded Power for Business-Critical Continuity
Module Information
(All units in mm)
321.4 ± 1.2 11.9 ± 1 Tyco Connector PN: 2007209 or FCI 10053363-400LF 106.7 ± 0.8
Rev. 7.10.09_81 HPS3000 Series 3 of 7
327.6 ± 1.2
AIRFLOW DIRECTION
11.6 ± 0.5 40 ± 0.8
Pin Assignments
Bottom
Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 AC LINE AC LINE n.c. AC NEUTRAL AC NEUTRAL n.c. n.c. n.c. +48 Vdc out +48 Vdc out +48 Vdc out +48 Vdc out +48 Vdc out +48 Vdc out +48 Vdc out +48 Vdc RTN +48 Vdc RTN +48 Vdc RTN +48 Vdc RTN +48 Vdc RTN +48 Vdc RTN +48 Vdc RTN n.c. V_STBY STBY_RTN_SENSE PRESENT# DCOK/PWOK# SDA HVCC PSON# #ALERT ISHARE
Top
Pin 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 AC LINE AC LINE n.c. AC NEUTRAL AC NEUTRAL n.c. n.c. n.c. +48 Vdc out +48 Vdc out +48 Vdc out +48 Vdc out +48 Vdc out +48 Vdc out +48 Vdc out +48 Vdc RTN +48 Vdc RTN +48 Vdc RTN +48 Vdc RTN +48 Vdc RTN +48 Vdc RTN +48 Vdc RTN n.c. SYS_GND STBY_SENSE ACOK# SMBUS_ALERT_OUT SCL A2 PSKILL A1 A0
8 ± 0.5
19
Embedded Power for Business-Critical Continuity
Rev. 7.10.09_81 HPS3000 Series 4 of 7
Timing Diagram
AC Input
AC On T Vout_Holdup
AC On T PWOK_Off_
Main Vout
T AC_On_Delay
T PWOK_Off_ T PWOK_Off_ T PWOK_On T PWOK_Off_ T PWOK_Delay T PWOK_On T sb_On T PWOK_On T PSON_PWOK T PWOK_Off
PWOK
5 vsb Vout T SB_Vout T PSON_On_Delay
PS_ON T ACOK_Delay AC_OK AC Input ON / OFF Cycle
PSON ON / OFF Cycle
Embedded Power for Business-Critical Continuity
Timing Signal Definitions
Turn ON/OFF Timing
Item Tvout_rise Tsb_on_delay Tac_on_delay Tvout_holdup Tpwok_holdup Tpson_on_delay Tpson_pwok Tacok_delay Tpwok_on Tpwok_off Tpwok_low Tsb_vout Description 48 V Output rise time Delay from AC being applied to 5 Vsb being within regulation. Delay from AC being applied to all output voltages being within regulation. Time all output voltages, including 5 Vsb, stay within regulation after loss of AC. Delay from loss of AC to de-assertion of PWOK Delay from PSON# active to output voltages within regulation limits. Delay from PSON# de-active to PWOK being de-asserted. Delay from loss of AC input to de-assertion of ACOK#. Delay from output voltages within regulation limits to PWOK asserted at turn on. Delay from PWOK de-asserted to 48 V dropping out of regulation limits. Duration of PWOK being in the de-asserted state during an off/on cycle using AC or the PSON# signal. Delay from 5 Vsb being in regulation to 48 V being in regulation at AC turn on. 10 5 5 400 50 10 100 1 100 50 2000 1000 1000 Min 5 Max 300 1500 2000 Units msec msec msec msec msec msec msec msec msec msec msec msec
Rev. 7.10.09_81 HPS3000 Series 5 of 7
Signals and Controls - All Models
PSON #
The PSON# signal is required to remotely turn on/off the power supply. PSON# is an active low signal that turns on the 48 V power rail. When this signal is not pulled low by the system, or left open, the 48 V output turns off. The 5 Vsb output remains on. This signal is pulled to a standby voltage by a pull-up resistor internal to the power supply. The power supply fan(s) shall operate at the lowest speed.
PSON# Signal Characteristic Signal Type
PSON# = Low PSON# = Open
Accepts an open collector/drain input from the system. Pulled-up to the 5 Vsb located in power supply. ON OFF MIN MAX 0.8 V 4.80 V 4 mA 400 msec 0 V 2.0 V -5 msec
Logic level low (power supply ON) Logic level high (power supply OFF) Source current, Vpson = low Power up delay: Tpson_on_delay
Embedded Power for Business-Critical Continuity
PWOK# (Power Good)
Rev. 7.10.09_81 HPS3000 Series 6 of 7
PWOK# is a power good signal and will be pulled LOW by the power supply to indicate that both the outputs are above the regulation limits of the power supply. When any output voltage falls below regulation limits or when AC power has been removed for a time sufficiently long so that power supply operation is no longer guaranteed, PWOK will be de-asserted to a HIGH state. The start of the PWOK# delay time shall be inhibited as long as the 48 V output is in current limit or the 5 Vsb output is below the regulation limit.
PSON# Signal Characteristic Signal Type Open collector/drain output from power supply. Pullup to 5 Vsb external to the power supply. ON OFF MIN Logic level low voltage, Isink=4mA Logic level high voltage, Isource=200µA Sink current, PWOK = low Source current, PWOK = high PWOK delay: Tpwok on PWOK rise and fall time Power down delay: Tpwok off 1 msec 100 msec 0 V 2.0 V MAX 0.8 V 4.80 V 4 mA 2 mA 1000 msec 100 µsec 1000 msec
PWOK = High PWOK = LOW
Power Supply Present Indicator (PRESENT#)
The PRESENT# signal is primarily used to provide a mechanism by which the host system can sense the number of power supplies physically present (operational or not). This pin is connected to ground in the power supply.
AC INPUT Present Indicator (ACOK#)
The AC OK# signal is used to indicate presence of AC input to the power supply. This signal shall be connected to 5 Vsb through a resistor on the host system side. A logic “Low” level on this signal shall indicate AC input to the power supply is present. A Logic “High” on this signal shall indicate a loss of AC input to the power supply.
Table 12 ACOK# Signal Characteristics Pull-up to 5 Vsb through a resistor in the host system. Present Not present MIN Logic level low voltage, Ising=4mA Logic level high voltage, Isink=50µA Sink current, PRESENT# = Low Source current, PRESENT# = High 0 V 2.0 V MAX 0.8 V 4.80 V 4 mA 50 µA
Signal Type PRESENT# = Low PRESENT# = High
Embedded Power for Business-Critical Continuity
Americas
Rev. 7.10.09_81 HPS3000 Series 7 of 7
LED INDICATORS
There will be a green POWER LED (PWR) to indicate that AC is applied to the PSU and standby voltage is available when blinking. This same LED should go solid when the 48 V output is enabled and operational.
5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698
Europe (UK) There will be an Amber Power Supply Fail LED (FAIL) to indicate that the power Waterfront Business Park supply has failed and a replacement of the unit is necessary. Faults including Merry Hill, Dudley UVP, OVP, OTP, or Fan Fail when PSON# is asserted “Logic Low” shall cause the West Midlands, DY5 1LX amber LED to turn on. The LED can be turned off by recycling PSON# signal or United Kingdom Telephone: +44 (0) 1384 842 211 by an AC power interruption more than 1 second. The LED shall be off when Facsimile: +44 (0) 1384 843 355 PSON# is not asserted “Logic Low”. Refer to table 13 for conditions of the LED’s: Asia (HK)
Table 13 LED Indicators Power LED (GREEN) OFF Blinking ON OFF ON
14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888
Power Supply Condition No AC power to PSU AC present / Standby Output On
Fail LED (AMBER) OFF OFF OFF ON Blinking
For global contact, visit:
www.PowerConversion.com techsupport.embeddedpower@ emerson.com
While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
Power supply 48 V output ON and OK Power supply failure (includes overvoltage, overtemperature) Current limit
Ordering Information
Model Number HPS3000-9 Main Output 48 Vdc
MTBF The power supply has a minimum MTBF of 300K hours using the Bell core 332, issue 6 specification @ 25 °C and 40 °C, ambient, at full load. With the power Emerson Network Power. supply installed in a system in a 25 °C ambient environment and The global leader in enabling business-critical continuity. operating at full load, capacitor life shall be 10 years, minimum for ALL electrolytic capacitors contained within this power supply. The power supply shall demonstrate a MTBF level of > 500,000 hours. AC Power Connectivity Quality Assurance Full QAV testing shall be conducted in accordance with Emerson Network DC Power Power Standards with reports available upon request. Embedded Computing Embedded Power Warranty Monitoring Emerson Network Power shall warrant the power supply to be free of defects in materials and workmanship for a minimum period of one year from the date Outside Plant of shipment, when operated within specifications. The warranty shall be fully Power Switching & Controls transferable to the end owner of the equipment powered by the supply. Precision Cooling Racks & Integrated Cabinets Services Surge Protection Main Output
Current 62.0 A Standby Output 5.0 V Standby Current 3.0 A