Embedded Power for Business-Critical Continuity
LPS120 Series
120 Watts
Total Power: Input Voltage: # of Outputs: 80 - 130 Watts 85 - 264 VAC Single
Rev. 09.15.09_12 LPS120 Series 1 of 3
Special Features
• • • • • • • • • • • • • Active power factor correction 3” x 5” footprint Less than 1U high EN61000-3-2 compliant Remote sense Power fail and remote inhibit Single wire current sharing Adjustable main output Built-in Class B EMI filter Overvoltage protection Overload protection Thermal overload protection 5 V Standby output and 12V Fan output
Electrical Specifications
Input
Input range: Frequency: Inrush current: Efficiency: EMI/RFI: Power factor: Safety ground leakage current: 85 - 264 VAC ; 127 - 300VDC 47 - 440 Hz 40 A max., cold start @ 25 °C 80% typical at full load FCC Class B conducted; CISPR22 Class B conducted; EN55022 Class B conducted; VDE0878PT3 Class B conducted 0.99 typical 0 .5 mA @ 50/60 Hz, 264 VAC input
Output
Maximum power: Adjustment range: Fan output: Standby outputs: 80 W for convection ; 130 W with 30CFM forced air ± 5% minimum on the main outputs 12 V @ 500mA - 5%, +7% 5V @ 500mA ± 5% Hold-up time: 20ms @ 125 W load, 120 VAC input Overload protection: Short circuit protection on all outputs. Case overload protected @ 120 - 135% above rating Overvoltage protection: 20 - 35% above nominal output Remote sense: Compensates for 0.5 V lead drop max. Will operate without remote sense connected. Reverse connection protected.
Logical Control
Safety
TUV: UL: CSA NEMKO: AUSTEL: CB: CE: 60950 60950 60950 60950 60950 Certificate and report Mark (LVD)
Power failure: Remote inhibit: Remote sense:
T TL logic signal goes high 100 - 500 msec after main output; it goes low at least 4 msec before loss of regulation Requires a contact closure to disable the outputs, except 5 V standby. C ompensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected.
Embedded Power for Business-Critical Continuity
Environmental Specifications
Operating temperature: 0° to 50 °C ambient derate each Mechanical Drawing output as 2.5% per degree from 50° to 70 °C. -20 °C start up -40 °C to +85 °C Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Operating; non-condensing 10% to 95% RH IEC68-2-6 to the levels of IEC721-3-2 > 550,000 hours at full load and 25 °C ambient conditions
3.00 (76.2) 2.55 (64.8)
Rev. 09.15.09_128 LPS120 Series 2 of 3
Storage temperature: Electromagnetic susceptibility: Humidity: Vibration: MTBF demonstrated
SK1
P1
EARTH
0.15" DIA. 4 places (4.0)
NEUTRAL
LIVE
4.55 (115.6)
5.00 (127.0)
V Adjust POT
SK3
1 5 6 10
2 SK2
1
M3.5 (2 places)
1.29 (32.8)
SK3
0.20" (5)
Embedded Power for Business-Critical Continuity
Ordering Information
Model Number LPS121 LPS122 LPS123 LPS124 LPS125 LPS128 Output Voltage 3.3 V 5 V 12 V 15 V 24 V 48 V Minimum Load 0 A 0 A 0 A 0 A 0 A 0 A Maximum Load with Convection Cooling 21 A 16 A 6.7 A 5.3 A 3.4 A 1.7A Maximum Load with 30CFM Peak Load Regulation2 Forced Air 36 A 26 A 10.8 A 8.7 A 5.4 A 2.7 A 29 A 29 A 12.8 A 10.0 A 6.3 A 3.2 A ± 2% ± 2% ± 2% ± 2% ± 2% ± 2% Ripple P/P (PARD)3 50 mV 50 mV 120 mV 150 mV 240 mV 480 mV
Americas
5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698
Rev. 09.15.09_12 LPS120 Series 3 of 3
Europe (UK)
1. Peak current lasting < 30 seconds with a maximum 10% duty cycle. 2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. 4. When in parallel a 10% load is required for each power supply.
Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355
Asia (HK)
Pin Assignments
Connector SK1 SK2 SK3 LPS120 Pin1 Pin3 TB-1 TB-2 Pin1 Pin2 Pin3 Pin4 Pin5 Pin6 Pin7 Pin8 Pin9 Pin10 Neutral Line COMMON Main output +V1 Remote sense -V1 Remote sense +Remote inhibit -Remote inhibit +Power fail Common SWP +12V 12V common +5V standby
14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888
For global contact, visit:
www.PowerConversion.com techsupport.embeddedpower @emerson.com
While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2009 Emerson Electric Co.
Mating Connectors (SK1)AC Input: (SK2)DC Output: (SK3) Control Signals:
Molex 09-50-8031 (connector) 08-52-0113 (pins) Molex series 19141-0058/0063 Spade lug Molex 90142-0010 (USA) PINS: 90119-2110 or Amp: 87977-3 PINS: 87309-8
Emerson Network Power Connector Kit # 70-841-020, includes all of the above. Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ± .02”. 3. mounting holes MH1, MH2, MH3 should be grounded for EMI purpose 4. Mounting MH1 is safety ground connection 5. Specifications are for convection rating at factory settings at 115 VAC input 25 °C unless otherwise stated. 6. This power supply requires mounting on metal standoffs 0.20” (5m) in height. 7. Warranty: 2 year 8. Weight: 0.71 lb. / 0.32 kg