0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
NLP250MEDICAL

NLP250MEDICAL

  • 厂商:

    EMERSON-NETWORKPOWER

  • 封装:

  • 描述:

    NLP250MEDICAL - Active PFC and EN61000-3-2 compliant - Emerson Network Power

  • 数据手册
  • 价格&库存
NLP250MEDICAL 数据手册
Embedded Power for Business-Critical Continuity NLP250 Medical Series Single Output Rev.05.12.09_181 NLP250 Medical Series 1 of 4 Total Power: 250 W Input Voltage: 85 - 264 VAC # of Outputs: Single Special Features • Medical safeties • Active PFC and EN61000-3-2 compliant • 250 W on main channel with forced air • Low profile fits 1U applications • U-Channel for maximum thermal performance • Optional cover (CJ suffix) • 5 V standby output • 12 V fan output • Integrated control and monitoring features • Overcurrent, overvoltage and overtemperature protection • Compliance to EN55022-B conducted noise standard • Dual AC fuses • RoHS compliant • 2 year warranty Electrical Specifications Input Input voltage range: Input frequency range: Input surge current: Safety ground leakage current: Input current: Input fuse: 264 Vac (cold start) 264 Vac, 50 Hz 120 Vac @ 250 W 230 Vac @ 250 W UL/IEC127 200 LFM forced air 250 LFM with cover Main output Main output Auxiliary outputs @ 120 Vac Input Main output 50 - 100% Step at 0.5 A/µs Main output Cyclic operation Singles 5 Vsb 12 V (fan) Universal input 85 - 264 Vac 47 - 63 Hz 40 A max. 150 µA 2.78 A rms 1.36 A rms T6.4 AH, 250 Vac In live and neutral 250 watts ± 5% ± 2.0% ± 5.0% 2.0 s max. 5.0% or 250 mV max. dev., 1 ms max recovery to 1% ±0.02%/°C 115%, ± 5% Continuous 0 A 5 V @ 1.0 A 12 V @ 0.3A Output Maximum power: Adjustment range: Total regulation: (line and load) Turn-on delay: Transient response: Safety • • • • VDE0750/EN60950 IEC950/IEC60601-1 File No. 1177400-3336-0759 UL60601-1 File No. E186249 Certificate No. 40014041 CB Ref DE1-36628 Temperature coefficient: Overvoltage protection: Short circuit protection: Minimum output current: Auxiliary outputs: (See Note 8, page 3) All specifications are typical at nominal input, full load at 25 °C unless otherwise stated Embedded Power for Business-Critical Continuity Rev.05.12.09_181 NLP250 Medical Series 2 of 4 EMC Characteristics (5) Conducted emissions: Harmonic current correction: Voltage flicker: ESD air: ESD contact: Radiated immunity: Fast transients: Surge: Conducted immunity: Voltage dips: EN55022, FCC part 15 EN61000-3-2 EN61000-3-3 EN61000-4-2 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-11 85 Vac @ 50 Hz 115 Vac @ 250 W 230 Vac @ 250 W Input/output Input/chassis Level B Compliant Compliant Level 3 Level 3 Level 3 Level 3 Level 3 Level 3 Compliant 20 ms @ 250 W 84% typ. 86% typ. 4000 Vac 2000 Vac 650g (22 oz) Telcordia SR-332 MIL-HDBK-217F 317,000 hours min. 158,000 hours min. General Specifications Hold-up time: Efficiency: Isolation voltage: Safety approvals (see Note 6, page 3): Weight: MTBF (@25º C): UL/cUL UL60601-1, VDE EN60601-1, CAN/CSA22.2 No. 601-1 Environmental Specifications Thermal performance: Operating ambient, (See derating curve) Non-operating 0 °C to 50 °C ambient, 200 LFM forced air 250 LFM with cover 0 °C to 50 °C ambient, 0 °C to 40 °C with cover Convection cooled 50 °C to 70 °C ambient, Convection cooled Relative humidity: Altitude: Vibration (See Note 7, page 3): Shock: Non-condensing Operating Non-operating 5 - 500 Hz Per MIL-STD-810E Derate linearly to 50% load 5 - 95% RH 10,000 feet max. 30,000 feet max. 2.5 G rms peak 516.4 Part IV 175 W -40 °C to +85 °C 250 W 0 °C to +70 °C Embedded Power for Business-Critical Continuity Ordering Information Output Voltage 12 V 24 V Notes Rev.05.12.09_181 NLP250 Medical Series  of 4 Output Current Min 0 A 0 A Max (free air) (1,4) Max (forced air) (2,4) 14.6 A 7.3 A 21 A 10.5 A Ripple (3) 120 mV 240 mV Total Regulation ± 2.0% ± 2.0% Model Numbers (9, 10) NLP250N-99S12J NLP250N-99S24J 1 Free air convection. Maximum continuous output power not to exceed 175 W. Refer to Figure 1 for the derating curve. 2 200 LFM (250 LFM with cover) forced air cooling from the longer side. Maximum continuous output power not to exceed 250 W. 3 Figure is peak-to-peak for room temperature rating. Output noise measurements are made across a 20 MHz bandwidth using a 6 inch twisted pair, terminated with a 10 µF tantalum capacitor and a 0.1 µF ceramic capacitor. 4 CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements. For optimum reliability no part of the heatsink should exceed 115 °C and no semi-conductor case temperature should exceed 120 °C. 5 No external filtering required during conducted emissions testing but some applications may require additional filtering to achieve system compliance. Compliance with radiated EMI specifications may require mounting in a suitable enclosure. 6 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 7 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G 8 5 V sb (standby) output is available whenever AC is present, regardless of remote ON/OFF signal status. 12 V (fan) present when main output is present. 9 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. “CJ” suffix indicates covered RoHS version. 10 NOTICE: Some models do not support all options. Please contact your local Emerson Network Power representative or use the on-line model number search tool at http://www.PowerConversion.com to find a suitable alternative. Mechanical Drawing CUSTOMER MOUNTING HOLES MAX. SCREW PENETRATION 0.08IN 6-32 J1 4.000 [101.60] E L N 1 J3 JP1 VR7 J4 J2 1.140 (28.96) 1 0.750 (19.05) M3.0 5.850 (148.59) 1 0.25 (6.35) 6.250 (158.75) M3.0 4 PLACES 7.000 [177.80] 6-32 4 PLACES 4.700 (119.38) 1.500 [38.10] 5.500 (139.70) BOTTOM VIEW 2.500 (63.50) Embedded Power for Business-Critical Continuity DERATING CURVE Output Power (Watts) Figure 1: Derating Curve Output Power (Watts) All Models Forced Air Figure 1b: Derating Curve With Cover Output Power (Watts) DERATING CURVE Output Power (Watts) WITH COVER 250 W 250 LFM (1.25 m/s) FORCED AIR COOLING 175 W 12 V Free Air 125 W NATURAL FREE AIR CONVECTION COOLING 75 W All Models Forced Air Americas Rev.05.12.09_181 NLP250 Medical Series 4 of 4 250 W 200 LFM (1.0 m/s) FORCED AIR COOLING 175 W 24 V Free Air 12 V Free Air 24 V Free Air 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 125 W NATURAL FREE AIR CONVECTION COOLING 87 W 75 W Europe (UK) 0W 0C 10 C 20 C 30 C 40 C 50 C 60 C 70 C 0W 0C 10 C 20 C 30 C 40 C 50 C 60 C 70 C Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Connector and Mating Connector Types Asia (HK) Connector J1 J2 J3 Type Mating Connector Type Molex 09-65-2058 (5273 series)void pins Molex 09-52-4054 (5239 series) or equivalent with Molex 2 and 4 or equivalent 08-52-0072 (2478 series) or equivalent crimp terminals Molex 22-23-2021 (6373 series) or equivalent Molex terminal block 387007504 or equivalent Molex 22-23-2091 (6373 series) or equivalent Molex 22-01-3027 (2695 series) or equivalent with Molex 08-50-01113 (2759 series) or equivalent crimp terminals Terminal block contains #6-32 screw with clamp washer suitable for wire size 12-22 awg (0.5-2.5 mm2). Max Torque tp 1.36 Nm (12 in.lb) Molex 22-01-3097 (2695 series) or equivalent with Molex 08-50-0113 (2759 series) or equivalent crimp terminals 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.PowerConversion.com techsupport.embeddedpower @emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. J4 Pin Connections J1 Pin 1 Pin 2 Pin 3 Ground/Earth Live Neutral Pin Connections Continued J2 Pin 1 Pin 2 +12 V SGND Vo Vo RTN RTN +S -S LS PS OFF PS ON SGND PW OK 5 Vsb DC OK Fan Voltage Return + Main Output + Main Output Main Return Main Return +Vo Remote Sense Vo Remote Sense Load Share Signal Remote ON/OFF signal NO Remote ON/OFF signal NC Signal Common Power Good Stand-by Voltage DC Power Good Signal Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2009 Emerson Electric Co. J3 Pin 1 Pin 2 Pin 3 Pin 4 J4 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9
NLP250MEDICAL 价格&库存

很抱歉,暂时无法提供与“NLP250MEDICAL”相匹配的价格&库存,您可以联系我们找货

免费人工找货