0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
NLP40-7627J

NLP40-7627J

  • 厂商:

    EMERSON-NETWORKPOWER

  • 封装:

  • 描述:

    NLP40-7627J - 40-50 W AC/DC Universal Input Switch Mode Power Supplies - Emerson Network Power

  • 数据手册
  • 价格&库存
NLP40-7627J 数据手册
NLP40 Series LOW TO MEDIUM POWER AC/DC POWER SUPPLIES • • • • • • • • Single, dual and triple output 40-50 W AC/DC Universal Input Switch Mode Power Supplies 1 4.25 x 2.5 x 1.15 inch package (1U applications) Smallest industry package Overvoltage and short circuit protection 40 W with free air convection EN55022, EN55011 conducted emission level B EN61000-4-2, -3, -4, -5, -6 immunity compliant UL, VDE and CSA safety approvals Available RoHS compliant The NLP40 series is a 40 W universal input ac-dc power supply on a 4.25 x 2.5 inch card with a maximum component height of 1.15 inches for use in 1U applications. This product is the smallest standard 40 W package in the industry making the series ideal for communication applications with space constraints where a standard 5 x 3 inch card solution is not suitable. The NLP40 provides 40 W of output power with free air convection cooling which can be boosted to 50 W with 20 CFM of air. Standard features include overvoltage and short circuit protection. The series, with full international safety approval and the CE mark, meets conducted noise EN55022 level B and has immunity compliance to EN61000-4-2,-3,-4, -5, -6. The NLP40 series is designed for use in low power data networking, computer and telecom applications such as hubs, routers, POS terminals, LCD projectors, cable modems and PABX’s. This list is not exclusive as the generic feature set of the NLP40 series with industry standard output configurations provides a solution for most low power applications including many industrial applications. All specifications are typical at nominal input, full load at 25 °C unless otherwise stated 2 YEAR WARRANTY SPECIFICATIONS OUTPUT SPECIFICATIONS Total regulation (Line and load) Rise time Transient response Temperature coefficient Overvoltage protection Short circuit protection Minimum output current INPUT SPECIFICATIONS Input voltage range (See Note 9) Input frequency range Input surge current Safety ground leakage current Input current Input fuse 120 Vac, cold start 230 Vac, cold start 120 Vac, 60 Hz 230 Vac, 50 Hz 120 Vac 230 Vac UL/IEC127 (10) GENERAL SPECIFICATIONS ±2.0% ±5.0% 1.0 s, max. Hold-up time Efficiency Isolation voltage Switching frequency Approvals and standards (See Note 8) Weight MTBF MIL-HDBK-217F Input/output Input/chassis Fixed 120 Vac 230 Vac 12 ms @ 40 W 20 ms @ 40 W 75% typical 3000 Vac 1500 Vac 65 kHz, ±5 kHz EN60950, IEC950, UL1950 VDE0805, CSA C22.2 No. 950 200 g (7.06 oz) 150,000 hours min. Main output Auxiliary outputs At turn-on Main output 5.0% max. dev., 25% step at 0.1 A/µs 1 ms rec. to 1.0% ±0.02%/°C Main outputs Cyclic operation Single Multiple 135%, ±15% Continuous 0A (See Note 5) ENVIRONMENTAL SPECIFICATIONS Universal input 90-264 Vac 120-370 Vdc 47-440 Hz 15 A max. 30 A max. 0.2 mA 0.4 mA 1.4 A rms 0.7 A rms 250 Vac H 3.15 A Thermal performance (See Notes 6, 7, 9) Operating ambient, 0 °C to +70 °C (see derating curve) Non-operating -40 °C to +70 °C 50 °C to 70 °C ambient, Derate to convection cooled 50% load 0 °C to 50 °C, ambient, 40 W convection cooled 0 °C to 50 °C ambient, 50 W 20 CFM forced air Peak (0 °C to +50 °C, 60 s) (See Note 2) Non-condensing Operating Non-operating 5-500 Hz per MIL-STD-810E 5% to 95% RH 10,000 feet max. 30,000 feet max. 2.4 G rms peak 516.4 Part IV Relative humidity Altitude Vibration (See Note 4) Shock EMC CHARACTERISTICS Conducted emissions Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity EN55022, FCC part 15 EN55022, FCC part 15 EN61000-4-2, level 3 EN61000-4-2, level 3 EN61000-4-5, level 3 EN61000-4-4, level 3 EN61000-4-3, level 3 EN61000-4-6, level 3 Perf. Perf. Perf. Perf. Perf. Perf. level B level A criteria 1 criteria 1 criteria 1 criteria 1 criteria 1 criteria 1 File Name: nlp40.pdf Rev (03): 08 Nov 2005 NLP40 Series LOW TO MEDIUM POWER AC/DC POWER SUPPLIES OUTPUT VOLTAGE +3.3 V (IA) +12 V (IB) –12 V (IC) +5 V (IA) +12 V (IB) –12 V (IC) +5 V (IA) +15 V (IB) –15 V (IC) +12 V (IA) -12 V (IB) +5 V (IA) +12 V (IB) 3.3 V (IA) 5V 12 V 15 V 24 V 48 V Notes 1 Single, dual and triple output 40-50 W AC/DC Universal Input Switch Mode Power Supplies 2 For the most current data and application support visit www.artesyn.com/powergroup/products.htm OUTPUT CURRENT RIPPLE MAX 4A 2A 0.2 A 4A 2A 0.2 A 4A 1.6 A 0.2 A 1.8 A 1.8 A 4A 2A 8A 8A 3.3 A 2.6 A 1.6 A 0.8 A (1) (3) TOTAL REGULATION MODEL NUMBER NLP40-76T366J (11,12) PEAK 5A 3A 1A 5A 3A 1A 5A 2A 1A (2) FAN (1) 4.5 A 3A 0.5 A 4.5 A 3A 0.5 A 4.5 A 2A 0.5 A 2.1 A 2.1 A 4.5 A 3A 9A 9A 4A 3.3 A 2A 1A 50 mV 120 mV 120 mV 50 mV 120 mV 120 mV 50 mV 150 mV 150 mV 120 mV 120 mV 50 mV 120 mV 50 mV 50 mV 120 mV 150 mV 240 mV 300 mV ±2.0% ±5.0% ±5.0% ±2.0% ±5.0% ±5.0% ±2.0% ±5.0% ±5.0% ±2.0% ±5.0% ±2.0% ±5.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% (5) NLP40-7608J (5) NLP40-7610J (5) 2.2 A 2.2 A 5A 3A 10 A 10 A 4.5 A 3.6 A 2.5 A 1.1 A NLP40-7627J (5) NLP40-7629J (5) NLP40-76S3J NLP40-7605J NLP40-7612J NLP40-7615J NLP40-7624J NLP40-7617J Maximum output power is 40 W for natural convection cooling. With 20 CFM fan cooling, the maximum output power is 50 W. 2 Peak output current lasting less than 60 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total reg. limits. 3 Figure is peak-to-peak. Output noise measurements are made across a 50 MHz bandwidth using a 12 inch twisted pair, terminated with a 47 µF capacitor. 4 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5 Hz to 500 Hz. 5 For multiple output units (except -7627J, 76T366J) to maintain stated regulation then: 0.25 ≤ IA / IB ≤ 5, for IB > 0.3 A 0.50 ≤ IA / IB ≤ 5, for IB < 0.3 A For maximum output current I(C) on triple output models, i.e. for IC = IMax., I A min. ≥ 0.5 A and IA ≥ IB. For NLP40-7627J only, to maintain stated regulation then: 0.5 ≤ IA / IB ≤ 2. For NLP40-76T366J only, to maintain stated regulation then: 0.25 ≤ IA / IB ≤ 4. 6 For optimum reliability, no part of the heatsink should exceed 120 °C, and no semiconductor case temperature should exceed 130 °C. 7 CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements. 8 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 9 When the input voltage is
NLP40-7627J 价格&库存

很抱歉,暂时无法提供与“NLP40-7627J”相匹配的价格&库存,您可以联系我们找货

免费人工找货