PTH05050WAZ

PTH05050WAZ

  • 厂商:

    EMERSON-NETWORKPOWER

  • 封装:

  • 描述:

    PTH05050WAZ - DC-DC CONVERTERS - Emerson Network Power

  • 数据手册
  • 价格&库存
PTH05050WAZ 数据手册
Embedded Power for Business-Critical Continuity PTH05050 5 Vin Single Output Total Power: 21.6W Input Voltage: 4.5 - 5.5VDC # of Outputs: Single Rev.07.30.08 PTH05050 1 of 5 Electrical Specifications Output Special Features • 6 A output current • 5 V input voltage • Wide-output voltage adjust (0.8 Vdc to 3.6 Vdc) • Auto-track™ sequencing* • Pre-bias start-up capability • Efficiencies up to 95% • Output ON/OFF inhibit • Output voltage sense • Point-of-Load-Alliance (POLA) compatible • Available RoHS compliant • 2 Year Warranty Voltage adjustability Setpoint accuracy Line regulation Load regulation total regulation Minimum load Ripple and noise Temperature co-efficient Transient response (see note 5) (See note 4) 0.8 - 3.6 Vdc ± 2.0% Vo ±10% mV typ. ±12 mV typ. ± 3% Vo 0A 20 mV pk-pk ± 5% Vo 70 μs recovery time Overshoot/undershoot 100 MV 20 MHz bandwidth -40°C to +85 °C Input Input voltage range Input current Remote ON/OFF Startup time Undervoltage lockout Track input voltage Pin 2 (See note 6, 7) See note 3 No load See note 1 4.5 - 5.5 Vdc 10 mA typ. Positive logic 1 V/ms 3.7 - 4.3 Vdc typ. ± 0.3% Vin Safety UL/cUL CAN/CSA-C22.2 No. 60950-1-03/UL 60950-1, File No. E186249 TÜV Product Service (EN60950) Certificate No. B 06 07 38572 068 EMC Charateristics Electrostatic discharge Conducted immunity Radiated immunity EN61000-4-2, IEC801-2 EN61000-4-6 EN61000-4-3 Embedded Power for Business-Critical Continuity General Specifications Efficiency Insulation voltage Switching frequency Approvals and standards Material flammability Dimensions Weight MTBF demonstrated Telcordia SR-332F 550 kHz to 650 Khz EN60950 UL/cUL60950 UL94V-0 (L x W x H) 22.10 x 12.57 x 8.50 mm 0.870 x 0.495 x 0.335 in. 2.9 g (0.10 oz) 7,092,000 hours See Efficiency Table 95% max. Non-isolated Rev.07.30.08 PTH05050 2 of 5 Environmental Specifications Thermal performance (see note 2) MSL ('Z' suffix only) Protection Short-circuit Auto reset 12 A typ. Operating ambient, temperature Non-operating JEDEC J-STD-020C -40 °C to +85 °C -40 °C to +125 °C Level 3 *Auto-track™ is a trade mark of Texas Instruments All specifications are typical at nominal input, full load at 25 °C unless otherwise stated Cin = 100 μF, Cout = 0 μF Ordering Information Output Power (Max.) Input Voltage Output Voltage Output Current (Min.) Output Current (Max.) Efficiency (Typ.) Regulation2 Line Load Model Number 21.6 W 4.5 - 5.5 Vdc 0.8 - 3.6 V 0A 6A 95% ± 10 mV ± 12 mV PTH05050 Embedded Power for Business-Critical Continuity Part Number System with Options Product Family Input Voltage Output Current Mechanical Package Output Voltage Code Pin Option (8) Mounting Option (9) Rev.07.30.08 PTH05050 3 of 5 Packaging Options PTH POLA compatible 05 05 = 5 V 05 05 = 6 A 0 Always 0 W W = Wide A A = Through-Hole Std. Pin Length (0.140") A = Surface-mount Tin/Lead Solder Ball S D = Horizontal Through-hole (RoHS 6/6) H = Horizontal Through-hole (roHS 5/6) S = Surface-mount (RoHS 5/6) Z = Surface-mount (RoHS 6/6) T No suffix = Trays T = Tape and Reel Notes 1 Remote ON/OFF. Positive Logic ON: Pin 3 open; or V > Vin - 0.5 V OFF: Pin 3 GND; or V < 0.8 V (min - 0.2 V). 2 See Figure 1 for safe operating curve. 3 A 100 μF electrolytic input capacitor is required for proper operation. The capacitor must be rated for a minimum of 300 mA rms of ripple current. 4 An external output capacitor is not required for basic operation. Adding 100 μF of distributed capacitance at the load will improve the transient response. 5 1 A/μs load step, 50 to 100% Iomax, Cout = 100 μF. 6 If utilized Vout will track applied voltage by ±0.3 V (up to Vo set point). 7 The pre-bias start-up feature is not compatible with Auto-Track™. This is because when the module is under Auto-Track™ control, it is fully active and will sink current if the output voltage is below that of a back-feeding source. Therefore to ensure a pre-bias hold-off, one of the following two techniques must be followed when input power is first applied to the module. The AutoTrack™ function must either be disabled, or the module’s output held off using the Inhibit pin. Refer to Application Note 158 for more details. 8 Tape and reel packaging only available on the surface-mount versions. 9 To order Pb-free (RoHS compatible) surface-mount parts replace the mounting option ‘S’ with ‘Z’, e.g. PTH05050WAZ. To order Pb-free (RoHS compatible) through-hole parts replace the mounting option ‘H’ with ‘D’, e.g. PTH05050WAD. 10 NOTICE: Some models do not support all options. Please contact your local sales representative or use the on-line model number search tool at http://www.powerconversions.com to find a suitable alternative. Output Voltage Adjustment of the PTH05050 Series The ultra-wide output voltage trim range offers major advantages to users who select the PTH05050. It is no longer necessary to purchase a variety of modules in order to cover different output voltages. The output voltage can be trimmed in a range of 0.8 Vdc to 3.6 Vdc. When the PTH05050 converter leaves the factory the output has been adjusted to the default voltage of 0.8 V. Efficiency Table (Io = 4 A) Output Voltage Efficiency Vo Vo Vo Vo Vo Vo Vo = = = = = = = 1.0 1.2 1.5 1.8 2.0 2.5 3.3 V V V V V V V 85% 87% 89% 90% 91% 93% 95% 90 TEMPERATURE (ºC) EFFICIENCY (%) 80 70 60 50 40 30 20 0 1 2 3 4 5 6 100LFM Nat conv 100 90 80 70 60 50 40 Vout 3.3V 2.5V 1.8V 1.2V 0.8V 0 1 2 3 4 5 6 OUTPUT CURRENT (A) OUTPUT CURRENT (A) Figure 1 - Safe Operating Area Vin = 5 V, Output Voltage = 3.3 V (See Note A) Figure 2 - Efficiency vs Load Current Vin = 5 V (See Note B) Embedded Power for Business-Critical Continuity Specifications Track Rev.07.30.08 PTH05050 4 of 5 Notes 1 2 6 Vout A B Vin 3 4 PTH05050 (Top View) 5 Co1 100F Electrolytic (Optional) + Co2 10F Ceramic (Optional) SOA curves represent the conditions at which internal components are within the Artesyn derating guidelines. Characteristic data has been developed from actual products tested at 25 °C. This data is considered typical data for the converter. Cin 100F (Required) + RSET 1%, 0.1W (Required) Inhibit GND GND Figure 3 - Standard Application 0.140 (3.55) 0.870 (22.10) 0.060 (1.52) 1 0.125 (3.18) 0.125 (3.18) 0.125 (3.18) 2 3 5 4 0.070 (1.78) (Standoff Shoulder) 0.750 (19.06) 6 0.060 (1.52) 0.040 (1.02) 6 Places 0.375 0.495 (12.57) (9.52) Lowest Component 0.010 min. (0.25) Bottom side Clearance TOP VIEW 0.335 (8.50) MAX. Dimensions in Inches (mm) Tolerances (unless otherwise specified) 2 Places 0.030 (0.76) 3 Places 0.010 (0.25) SIDE VIEW Host Board Figure 4 - Plated Through-Hole Mechanical Drawing Embedded Power for Business-Critical Continuity Americas Specifications 0.870 (22.10) 0.060 (1.52) 1 2 3 5 4 SIDE VIEW 0.750 (19.06) 6 0.495 0.375 (12.57) (9.52) Solder Ball 0.040 (1.02) 6 Places 0.060 (1.52) 0.335 (8.50) max.* *After solder reflow on customer board 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 (760) 930 4600 Facsimile: +1 (760) 930 0698 Rev.07.30.08 PTH05050 5 of 5 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 0.125 (3.18) 0.125 (3.18) 0.125 (3.18) Asia (HK) TOP VIEW Dimensions in Inches (mm) Tolerances (unless otherwise specified) 2 Places 0.030 (0.76) 3 Places 0.010 (0.25) 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.powerconversion.com technicalsupport@ powerconversion.com Figure 5 - Surface-Mount Mechanical Drawing Pin Connections Pin No. Function While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. 1 2 3 4 5 6 Ground Track Vin Inhibit* Vo adjust Vout Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower. com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co. *Denotes negative logic: Open = Normal operation Ground = Function active
PTH05050WAZ 价格&库存

很抱歉,暂时无法提供与“PTH05050WAZ”相匹配的价格&库存,您可以联系我们找货

免费人工找货