Power Capacitors Power Factor Correction B32343C Construction Dielectric: Polypropylene film Non PCB, biodegradable soft resin Extruded round aluminum can with stud Provided with discharge resistors Features Three phase, delta connected Naturally air cooled or forced air cooling Indoor mounting Typical applications PFC and detuned systems Terminals Fast-on terminals Mounting parts Threaded stud at bottom of can Max. torque = 4 Nm for M8 (Ø 53 mm) Max. torque = 10 Nm for M12 (Ø 63.5 mm) FK PM PFC Page 1 of 6 December 2004 Power Capacitors Power Factor Correction B32343C Technical data and specifications Standard Rated capacitance CN & QR Tolerance (%) Rated voltage UR Rated frequency fR Mean life expectancy Maximum ratings Maximum permissible overvoltage Umax UR + 10% (up to 8 h daily) UR + 15% (up to 30 min daily), UR + 20% (up to 5 min daily) UR + 30% (up to 1 min daily) 1.5 x IR (IR: rated current), including combined effects of harmonics, overvoltages and capacitance Max. 5 000 switchings per year according IEC 831 Up to 200 x IR < 0.2 W/kvar < 0.45 W/kvar 2.15 x UR , 10 s 3 000 VAC, 10 s -25/D Max. temp. 55 °C Max. mean 24 h = 45 °C Max. mean 1 year = 35 °C Safety Self-healing technology, overpressure disconnector, maximum allowed fault current 10 000 A in accordance with UL 810-standard Aluminum/cylindrical IP00, IP20, optionally IP54 95% 4 000 m above sea level Upright Threaded M8 (4 Nm / Ø 53 mm), M12 (10 Nm / Ø 63.5mm) IEC 831-1+2, IS: 13340/41 UL 810 5th edition, cUL file E106388 According to dimensions table -5 / +10 According to dimensions table 50/60 Hz Up to 100 000 operating hours Maximum permissible overcurrent Imax Number of switching operations Transient inrush current (max) IS Losses: Dielectric Total Test voltage, terminal/terminal UTT Test voltage, terminal/case UTC Temperature class Case/shape Enclosure Permissible maximum humidity Maximum permissible altitude Mounting position Mounting and grounding FK PM PFC Page 2 of 6 December 2004 Power Capacitors Power Factor Correction B32343C Dimensional drawing 11,8±0,5 FAST-ON Terminal 6,35 x 0,8 Creepage distance Clearance Expansion to l ±2 + α Marking l ±2 Diameter (ø) Expansion α Mounting M12 10.5 mm (ø 53) 10.0 mm (ø 63.5) 13.0 mm (ø 53) 16.5 mm (ø 63.5) 53 mm 63.5 mm max. 12 mm Torque Toothed washer Hex nut KLK1670-2 M12 (ø 63.5 mm) T=10 Nm J12.5 DIN 6797 BM12 DIN 439 M8 (ø 53 mm) T=4 Nm J8.0 DIN 6797 BM8 DIN 439 FK PM PFC Page 3 of 6 d 16 December 2004 Power Capacitors Power Factor Correction Rated voltage: 230 VAC, 50/60 Hz, delta connection Type 50 H z Output kvar MKP230-D-0.5 MKP230-D-0.7 MKP230-D-1.0 MKP230-D-1.5 0.5 0.7 1.0 1.5 IR A 1.3 1.9 2.5 3.8 60 H z Output kvar 0.6 0.9 1.2 1.8 IR A 1.6 2.3 3.0 4.6 CN µF 3 * 10 3 * 15 3 * 20 3 * 30 dxh mm 53 x 114 53 x 114 63.5 x 129 63.5 x 129 Weight B32343C Ordering code kg 0.30 0.30 0.30 0.40 B32343C2002A530 B32343C2002A730 B32343C2012A030 B32343C2012A530 Rated voltage: 400 VAC, 50/60 Hz, delta connection Type 50 H z Output kvar MKP400-D-1.0 MKP400-D-1.5 MKP400-D-2.0 MKP400-D-2.5 MKP400-D-5.0 1.0 1.5 2.0 2.5 5.0 IR A 1.4 2.2 2.9 3.6 7.2 60 H z Output kvar 1.2 1.8 2.4 3.0 6.0 IR A 1.7 2.6 3.5 4.3 8.6 CN µF 3*7 3 * 10 3 * 13 3 * 17 3 * 33 dxh mm 53 x 114 53 x 114 63.5 x 129 63.5 x 129 63.5 x 129 Weight Ordering code kg 0.30 0.30 0.40 0.40 0.40 B32343C4012A000 B32343C4012A500 B32343C4022A000 B32343C4022A500 B32343C4052A000 Rated voltage: 415 VAC, 50/60 Hz, delta connection Type 50 H z Output kvar 1.0 1.5 2.0 2.5 5.0 IR A 1.4 2.1 2.8 3.5 7.0 60 H z Output kvar 1.2 1.8 2.4 3.0 6.0 IR A 1.6 2.4 3.4 4.2 8.4 CN µF 3*6 3*9 3 * 12 3 * 15 3 * 31 dxh mm 53 x 114 53 x 114 53 x 114 63.5 x 129 63.5 x 154 Weight Ordering code kg 0.30 0.30 0.40 0.40 0.40 B32343C4012A010 B32343C4012A510 B32343C4022A010 B32343C4022A510 B32343C4052A010 MKP415-D-1.0 MKP415-D-1.5 MKP415-D-2.0 MKP415-D-2.5 MKP415-D-5.0 Rated voltage: 440 VAC, 50/60 Hz, delta connection Type 50 H z Output kvar MKP440-D-0.9 MKP440-D-1.0 MKP440-D-1.2 MKP440-D-1.5 MKP440-D-2.1 MKP440-D-2.5 MKP440-D-4.2 MKP440-D-5.0 0.9 1.0 1.2 1.5 2.1 2.5 4.2 5.0 IR A 1.2 1.3 1.6 2.0 2.7 3.3 5.5 6.5 60 H z Output kvar 1.0 1.2 1.5 1.8 2.5 3.0 5.0 6.0 IR A 1.3 1.6 2.0 2.3 3.3 3.9 6.6 7.8 CN µF 3*5 3*6 3*7 3*8 3 * 11 3 * 13 3 * 23 3 * 27 dxh mm 53 x 114 53 x 114 53 x 114 53 x 114 53 x 114 63.5 x 129 63.5 x 129 63.5 x 154 Weight Ordering code kg 0.30 0.30 0.30 0.30 0.40 0.30 0.40 0.50 B32343C4011A040 B32343C4012A040 B32343C4011A540 B32343C4012A540 B32343C4021A540 B32343C4022A540 B32343C4051A040 B32343C4052A040 Rated voltage: 480 VAC, 50/60 Hz, delta connection Type 50 H z Output kvar MKP480-D-1.5 MKP480-D-2.0 MKP480-D-2.5 1.5 2.0 2.5 IR A 1.8 2.4 3.0 60 H z Output kvar 1.8 2.4 3.0 IR A 2.2 2.9 3.6 CN µF 3*7 3*9 3 *11 dxh mm 63.5 x 129 63.5 x 129 63.5 x 129 Weight kg 0.40 0.40 0.40 B32343C4012A580 B32343C4022A080 B32343C4022A580 Ordering code FK PM PFC Page 4 of 6 December 2004 Power Capacitors Power Factor Correction Rated voltage: 525 VAC, 50/60 Hz, delta connection Type 50 H z Output kvar MKP525-D-1.0 MKP525-D-1.5 MKP525-D-2.0 MKP525-D-2.5 1.0 1.5 2.0 2.5 IR A 1.1 1.6 2.2 2.7 60 H z Output kvar 1.2 1.8 2.4 2.7 IR A 1.3 2.0 2.6 3.0 CN µF 3*4 3*6 3*8 3*9 dxh mm 53 x 114 53 x 114 63.5 x 129 63.5 x 129 Weight B32343C Ordering code kg 0.30 0.30 0.40 0.40 B32343C5012A020 B32343C5012A520 B32343C5022A020 B32343C5022A520 FK PM PFC Page 5 of 6 December 2004 Power Capacitors Power Factor Correction B32343C Cautions Discharge and short circuit capacitor before handling! Mechanical damage In case of dents of more than 0.5 mm or any other mechanical damage, capacitors must not be used at all. Vibration resistance The resistance to vibration of capacitors corresponds to IEC 68, part 2–6. Max. test conditions: Test duration 2 h corresponding to max. 0.7 g Frequency range 10 ... 55 Hz corresponding to max. 0.7 g Displacement amplitude 0.75 mm corresponding to max. 0.7 g These figures apply to the capacitor alone. Because the fixing and the terminals may influence the vibration properties, it is necessary to check stability when a capacitor is built in and exposed to vibration. Irrespective of this, you are advised not to locate capacitors where vibration amplitude reaches the maximum in strongly vibrating equipment. Connection Make sure connection cables are of flexible type or flexible copper bands are used. This is mandatory to allow the overpressure disconnector work and avoid mechanical stress on the terminals and feed throughs. The connection cables to the capacitor should be designed for a current of at least 1.5 times the rated current so that no heat is conducted into the capacitor. If reactors are used in an application, the distance between reactor and capacitor must be great enough so that no heat of the reactors, which are operating at a much higher temperature level, is conducted via connection cable to the capacitors. Avoid bending cable lugs, cables or other mechanical force on the terminals. Otherwise leakages may set the safety device out of operation. Ensure firm fixing of terminals, fixing torque to be applied as per individual specification. Maximum specified terminal current (please refer to technical data of specific series) must not be exceeded at any case. Grounding The threaded bottom stud of the capacitor has to be used for grounding. In case grounding is done via metal chassis that the capacitor is mounted to, the layer of varnish beneath the washer and nut should be removed. Storage and operating conditions Do not use or store capacitors in corrosive atmosphere, especially where chloride gas, sulfide gas, acid, alkali, salt or the like are present. In dusty environments regular maintenance and cleaning especially of the terminals is required to avoid conductive path between phases and/or phases and ground. U Please read information about PFC capacitors and cautions as well as installation and maintenance instructions (Power Factor Correction Product Profile, actual version) to ensure optimum performance and prevent products from failing, and in worst case, bursting and fire, etc. Information given in the PFC-product profile and values given in the data sheet reflect typical specifications. You are kindly requested to approve our product specifications or request our approval for your specification before ordering.  EPCOS AG 2004. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Association), unless otherwise agreed. FK PM PFC Page 6 of 6 December 2004
B32343C4022A000
### 物料型号 - 型号:B32343C

### 器件简介 - 构造:采用聚丙烯薄膜作为介质,非PCB、可生物降解的软树脂,铝制圆形外壳带有螺柱,配备放电电阻器。 - 特点:三相,三角接法,自然空气冷却或强制空气冷却,室内安装。

### 引脚分配 - 端子:快速连接端子。 - 安装部件:底部有螺纹螺柱,M8规格最大扭矩为4Nm(直径53mm),M12规格最大扭矩为10Nm(直径63.5mm)。

### 参数特性 - 标准:IEC 831-1+2, IS: 13340/41, UL 810 5h版,cUL文件E106388。 - 额定电容:根据尺寸表。 - 容差:-5%/+10%。 - 额定电压:根据尺寸表。 - 额定频率:50/60Hz。 - 平均寿命:高达100,000小时。 - 最大额定值: - 最大允许过电压Umax:UR + 10%(每日最多8小时)UR + 15%(每日最多30分钟)UR + 20%(每日最多5分钟)UR + 30%(每日最多1分钟)。 - 最大允许过电流/max:1.5 x IR(IR:额定电流),包括谐波、过电压和电容的联合效应。 - 开关操作次数:每年最多5000次开关操作,根据IEC 831。 - 瞬态涌入电流(最大)/s:高达200x IR。 - 介质损耗角:<0.2 W/kvar <0.45 W/kvar。 - 测试电压,端子/端子UTT:2.15 x UR,10秒。 - 测试电压,端子/外壳Urc:3000 VAC,10秒。 - 温度等级:-25/D。 - 安全:自愈技术,过压断路器,最大允许故障电流10000A,符合UL 810标准。

### 功能详解 - 应用:PFC和调谐系统。 - 外壳/形状:铝/圆柱形。 - 外壳:IP00, IP20, 可选IP54。 - 允许的最大湿度:95%。 - 最大允许海拔:4000米以上海平面。 - 安装位置:垂直。 - 安装和接地:螺纹M8(4Nm/53mm),M12(10Nm/63.5mm)。

### 应用信息 - 额定电压:230VAC, 50/60Hz,三角接法。 - 尺寸图:提供了详细的尺寸和安装信息。

### 封装信息 - 封装:铝制圆柱形。 - 安装:垂直安装,螺纹M8和M12,具体扭矩和尺寸已提供。