B44066T0025E402_07 数据手册
Thyristor module for dynamic PFC Accessories for Power Factor Correction Series/Type: TSM-LC25/TSM-LC50 Ordering code: B44066T0025E402/B44066T0050E402 Date: Version: May 2007 4 Content of inside pages of data sheet. Data will be automatically entered into frontpage headlines, headers and footers. Please fill in the table and then change the colour to “White”. This ensures that the table disappears for the customer pdf. Identification/Classification 1: (header 1) Identification/Classification 2: (header 2) Ordering code: Series/Type: Preliminary data (optional): (if necessary) Department: Date: Thyristor module for dynamic PFC Accessories for Power Factor Correction B44066T0025E402/B44066T0050E402 TSM-LC25/TSM-LC50 Preliminary data FK PC PM PFC May 2007 © EPCOS AG 2007. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Thyristor module for dynamic PFC Accessories for Power Factor Correction Preliminary data Characteristics Fast electronically controlled self observing thyristor switch Usage in dynamic (fast) power factor correction systems For capacitive loads up to 50 kvar B44066T0025E402/B44066T0050E402 TSM-LC25/TSM-LC50 Features Easy installation: self-check after turn-on of main voltage Display and control via LED-display Permanent self-controlling: voltage parameters, phase sequence, capacitor output, temperature Technical data Dimensions Weight Voltage Maximum voltage - in conventional PFC-systems (without reactors) - in detuned PFC-systems (7% detuning) - in detuned PFC-systems (14% detuning) Frequency Max. power 440 V 440 V (no upward tolerance permitted) 400 V 50 Hz/60 Hz TSM-LC 25: 25 kvar for PFC-systems with/without reactors up to 14% TSM-LC 50: 50 kvar for PFC-systems with/without reactors up to 14% (cascading of several modules possible for increasing the kvar output) 10 … 24 V DC, internally insulated Operation, faults, activation, temperature Note: Before re-switching after temperature fault, heat sink temperature must be below 50 °C (hysteresis)! Display Power circuit Thermal power Fuses* (required for protection of TSM-LC and capacitor): *not included in the delivery Switching time Operating ambient temperature Ordering code 2 LEDs/phase connection: 2 × two-phase (L1, L3) with 4 terminals 25 mm2 cross section PD (W) = 2.0 × I (A) 25 kvar: at 400 V typical 75 W 50 kvar: at 400 V typical 150 W 3 × electronic fuse „superflink“ (NH00 AC 690 V) 50 kvar: 125 A (e.g. SIBA Art.No.: 20 209 20-125) 25 kvar: 63 A (e.g. SIBA Art.No.: 20 209 20-63) approx. 5 ms –10 °C ... +55 °C TSM-LC 25: B44066T0025E402 TSM-LC 50: B44066T0050E402 157 × 200 × 180 mm (w × h × d) 4.8 kg 3 × 400 V Activation Monitoring FK PC PM PFC Please read Cautions and warnings and Important notes at the end of this document. Page 2 of 6 May 2007 Thyristor module for dynamic PFC Accessories for Power Factor Correction Preliminary data Connection diagram Three-phase load (standard) Capacitor branch L 1 (R) L2 (S) L3 (T) N PE Fuse superfast 125A at 50kvar 63A at 25 kvar B44066T0025E402/B44066T0050E402 TSM-LC25/TSM-LC50 input (controller signal) _ + S ignal 10-24VDC L1 fault/ “O n” operation L3 fault/ “O n” operation TSM - LC electronic thyristor-module for capacitor switching C1 L1 L3 C3 FK PC PM PFC Please read Cautions and warnings and Important notes at the end of this document. Page 3 of 6 May 2007 Thyristor module for dynamic PFC Accessories for Power Factor Correction Preliminary data Connection diagram Single (two) phase load e.g. single phase welding machine L 1 (R) L2 (S) L3 (T) B44066T0025E402/B44066T0050E402 TSM-LC25/TSM-LC50 PE input (controller signal) +_ S ignal 10-24VDC L1 fault/ “O n” operation L3 fault/ “O n” operation TSM - LC electronic thyristor-module for capacitor switching C1 L1 L3 C3 C1 C2 FK PC PM PFC Please read Cautions and warnings and Important notes at the end of this document. Page 4 of 6 May 2007 Thyristor module for dynamic PFC Accessories for Power Factor Correction Preliminary data Cautions and warnings B44066T0025E402/B44066T0050E402 TSM-LC25/TSM-LC50 General • Thyristor modules TSM series may only be used for the purpose they have been designed for. • Thyristor modules TSM series may only be used in combination with appropriate pre-switched grid separator device. • Thyristor modules have to be projected in such a way that in case of any failure no uncontrolled high current and voltages may occur. • The devices in operation have to be protected against moisture and dust, sufficient cooling has to be assured. Attention Due to the switching principle of the thyristor module the power capacitors are permanently loaded to the peak value of the grid voltage (DC voltage) even when switched off. Therefore the following rules have to be obeyed in any case: • For standard PFC-systems (without reactors) power capacitors of 440 V nominal voltage have to be used; for detuned systems PFC capacitors of 525 V nominal voltage have to be used. • Due to the high voltage (2 × peak value of nominal voltage) that occurs, the discharge resistors of the power capacitors have to be replaced by special types. • In dynamic systems with TSM modules no fast discharge reactors may be used (reactor = DCwise short circuit). • For standard PFC-systems 2 current limiting reactors are mandatory per thyristor module. • Thyristor modules in general have to be protected by superfast electronic fuses. Principles for dimensioning have to be considered. Fuses in the system have to be marked. • Due to the special switching, the PFC capacitors are fully loaded even when the particular step has been switched off. Protection against contact has to be guaranteed. Warning signals in the systems are required. • Even in switched off state no electrical isolation is achieved for electronic switches. Therefore parts of the systems may not be touched after switching off the complete system before the capacitors have been completely discharged. FAILURE TO FOLLOW CAUTIONS MAY RESULT, WORST CASE, IN PREMATURE FAILURES OR PHYSICAL INJURY. U Please read cautions information about PFC capacitors and cautions as well as installation and maintenance instructions in the actual version of the Product Profile Power Factor Correction to ensure optimum performance and prevent products from failing, and in worst case, bursting and fire, etc. The actual Product Profile is available at www.epcos.com/publications. Information given in the PFC-product profile and values given in the data sheet reflect typical specifications. You are kindly requested to approve our product specifications or request our approval for your specification before ordering. FK PC PM PFC Please read Cautions and warnings and Important notes at the end of this document. Page 5 of 6 May 2007 Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as “hazardous”). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSSP, MiniBlue, MLSC, MotorCap, PhaseCap, PhaseMod, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. FK PC PM PFC Page 6 of 6 May 2007
B44066T0025E402_07
1. 物料型号: - 系列/型号:TSM-LC25/TSM-LC50 - 订购代码:B44066T0025E402/B44066T0050E402

2. 器件简介: - 该器件是用于动态功率因数校正(PFC)的晶闸管模块,适用于电容性负载,最大可达50 kvar。

3. 引脚分配: - 功率回路连接:2个两相(L1, L3)带有4个端子,每个端子的截面积为25 mm²。

4. 参数特性: - 尺寸:157 x 200 x 180 mm(宽x高x深) - 重量:4.8 kg - 电压:3 x 400V - 最大电压:根据不同的PFC系统(无电抗器、7%失谐、14%失谐),最大电压分别为440V、440V(不允许向上公差)和400V。 - 频率:50Hz/60Hz - 最大功率:TSM-LC25为25 kvar,TSM-LC50为50 kvar(可以级联多个模块以增加kvar输出) - 激活电压:10 ... 24 V DC,内部绝缘 - 监控功能:操作、故障、激活、温度(注意:在因温度故障重新开关之前,散热器温度必须低于50°C(滞后)) - 显示:每相2个LED - 热功率:PD(W)= 2.0x1(A) 25 kvar:在400V时典型为75W,50 kvar:在400V时典型为150W - 保险丝(需要保护TSM-LC和电容器):3个电子保险丝superflink"(NH00 AC 690 V)50 kvar:125 A(例如SIBA型号:20 209 20-125),25 kvar:63 A(例如SIBA型号:20 209 20-63) - 开关时间:约5 ms - 操作环境温度:-10°C... +55°C

5. 功能详解: - 快速电子控制自观察晶闸管开关,适用于动态(快速)功率因数校正系统。 - 易于安装:主电压开启后自检。 - 通过LED显示进行显示和控制。 - 永久自控制:电压参数、相序、电容器输出、温度。

6. 应用信息: - 用于动态功率因数校正系统,适用于电容性负载。

7. 封装信息: - 封装尺寸:157 x 200 x 180 mm(宽x高x深)。