Temperature measurement
B57514K
Probe assemblies
K514
Dimensional drawing
Applications
Temperature measurement in household
appliances (e.g. dryers, cookers, small
appliances)
Features
NTC thermistor assembled in a stainless
steel case with cable outlet
Temperature range 20 to 200 °C
Wire heat-resistant up to 200 °C
(PTFE-insulated wire in fiberglass sleeve)
Fast and simple flange installation
Options
Alternative casing, cable lengths,
R/T characteristics, connectors available
on request.
Delivery mode
Bulk
Dimensions in mm
Approx. weight 4.5 g
General technical data
Climatic category
Resistance tolerance
Rated temperature
Dissipation factor
Thermal time constant
Insulation resistance
Test voltage
(IEC 60068-1)
(in air)
(in water)
(V = 500 V DC)
(t = 1 s)
∆RR/RR
TR
δth
τa
Rins
Vtest
20/200/42
±2.5
100
approx. 3
approx. 3
> 100
1250
%
°C
mW/K
s
MΩ
V AC
Electrical specification and ordering codes
R100
Ω
3300
R25
Ω
48538
Please read Cautions and warnings and
Important notes at the end of this document.
No. of R/T
characteristic
7002
Page 2 of 11
B25/100
K
3988 ±1%
Ordering code
B57514K0493A001
Temperature measurement
B57514K
Probe assemblies
K514
Reliability data
Test
Standard
Storage in
dry heat
IEC
60068-2-2
Storage in damp
heat, steady state
Rapid temperature
cycling
Voltage proof test
Insulation test
Test conditions
∆R25/R25
(typical)
< 3%
Storage at upper category
temperature
T: 200 °C
t: 1000 h
IEC
Temperature of air: 85 °C
< 3%
60068-2-67 Relative humidity of air: 85%
Duration: 1000 h
Lower test temperature: 20 °C < 3%
Upper test temperature: 200 °C
Number of cycles: 1000
Medium: air
Applied voltage between metal
housing and sensor wires:
1250 V AC/60 s
The sensors are placed in a
vessel containing metallic balls
of 1 mm diameter (with total
immersed head) at room
temperature. The applied voltage
is 500 V DC.
Remarks
No visible
damage
No visible
damage
No visible
damage
No flashover
Above
100 MΩ
Note
Contact of NTC thermistors with any liquids and solvents shall be prevented. It must be
ensured that no water enters the NTC thermistors (e.g. through plug terminals).
Avoid dewing and condensation unless thermistor is specified for these conditions.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 11
Temperature measurement
B57514K
Probe assemblies
K514
R/T characteristics
R/T No. 7002
T (°C) B25/100 = 3988 K
T (°C)
RT/R25
α (%/K)
B25/100 = 3988 K
T (°C)
RT/R25
α (%/K)
B25/100 = 3988 K
RT/R25
α (%/K)
55.0
50.0
45.0
40.0
35.0
96.33
66.866
47.037
33.508
24.156
7.4
7.2
6.9
6.7
6.4
65.0
70.0
75.0
80.0
85.0
0.20872
0.17558
0.14837
0.12592
0.10731
3.5
3.4
3.3
3.2
3.2
185.0
190.0
195.0
200.0
205.0
0.0086582
0.0078408
0.0071148
0.0064685
0.005892
2.0
2.0
1.9
1.9
1.8
30.0
25.0
20.0
15.0
10.0
17.613
12.98
9.6643
7.2656
5.5129
6.2
6.0
5.8
5.6
5.4
90.0
95.0
100.0
105.0
110.0
0.091816
0.078862
0.067988
0.058824
0.051071
3.1
3.0
2.9
2.9
2.8
210.0
215.0
220.0
225.0
230.0
0.0053767
0.0049152
0.0045011
0.0041287
0.0037934
1.8
1.8
1.7
1.7
1.7
5.0
0.0
5.0
10.0
15.0
4.22
3.2575
2.5348
1.9876
1.5699
5.3
5.1
4.9
4.8
4.6
115.0
120.0
125.0
130.0
135.0
0.044489
0.03888
0.034084
0.02997
0.02643
2.7
2.7
2.6
2.5
2.5
235.0
240.0
245.0
250.0
255.0
0.0034908
0.0032173
0.0029697
0.0027451
0.0025412
1.6
1.6
1.6
1.6
1.5
20.0
25.0
30.0
35.0
40.0
1.2488
1.0000
0.80594
0.65355
0.53312
4.5
4.4
4.3
4.1
4.0
140.0
145.0
150.0
155.0
160.0
0.023373
0.020727
0.018429
0.016427
0.014679
2.4
2.4
2.3
2.3
2.2
260.0
265.0
270.0
275.0
280.0
0.0023556
0.0021865
0.0020323
0.0018913
0.0017623
1.5
1.5
1.5
1.4
1.4
45.0
50.0
55.0
60.0
0.43735
0.36074
0.29911
0.24925
3.9
3.8
3.7
3.6
165.0
170.0
175.0
180.0
0.013149
0.011806
0.010623
0.0095804
2.2
2.1
2.1
2.0
285.0
290.0
295.0
300.0
0.0016441
0.0015357
0.001436
0.0013444
1.4
1.4
1.3
1.3
Please read Cautions and warnings and
Important notes at the end of this document.
Page 4 of 11
Temperature measurement
B57514K
Probe assemblies
K514
Cautions and warnings
General
See "Important notes" on page 2.
Storage
Store thermistors only in original packaging. Do not open the package prior to processing.
Storage conditions in original packaging: storage temperature 25 °C ... +45 °C, relative
humidity ≤75% annual mean,
很抱歉,暂时无法提供与“B57514K0493A001”相匹配的价格&库存,您可以联系我们找货
免费人工找货