NTC thermistors for temperature measurement
NTC Probes
Series/Type:
Ordering code:
M703/10K/A39
B57703M0103A039
Date:
Version:
2010-05-03
1
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the
table and then change the color to "white". This ensures that the table disappears (invisible) for the customer PDF.
Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it!
Identification/Classification 1
(header 1 + top left header bar):
NTC thermistors for temperature measurement
Identification/Classification 2
(header 2 + bottom left header bar):
NTC Probes
Ordering code: (top right header bar)
B57703M0103A039
Series/Type: (top right header bar)
M703/10K/A39
Preliminary data (optional): (if necessary)
Department:
SEN NTC PD
Date:
2010-05-03
Version:
1
Prepared by:
Noor T. Hardiyanto
Release signed by:
Noor T. Hardiyanto
Release signed QS:
Duduh Khotim
Modifications/Remarks:
Customer, PN: Alcatel, T115/21044
Filename:B57703M0103A039.doc
Specification No.:
Issue of specification:
Date of specification:
Date of confirmation of specification by EPCOS:
PPAP issue:
Reliability
PPAP date:
Extended reliability (more than standard)
EPCOS AG 2010. Reproduction, publication and dissemination of this publication, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited
NTC thermistors for temperature measurement
NTC Probes
B57703M0103A039
M703/10K/A39
Application
Air Temperature Sensor for base
Station in Telecom Application
Dimensions in mm
Version
NTC thermistor soldered to wire AWG 26 PTFE insulated and potted to the ring tongue.
No. Item
1
2
3
4
Thermistor
Ring Tongue
Casting
Wire
Material
Property
Remarks
Ceramic
EPCOS NTC
CuZn, tinned
Epoxy Resin
Copper Silvered PTFE
Insulated
AWG26/7 E=600V
Ratings and characteristics
Climatic category (IEC 60068-1)
Lower category temperature
Upper category temperature
Black
Black
: 55/125/56
[°C] : -55
[°C] : +125
Rated resistance RN // Tolerance
Rated temperature
B-value : B(25/100) // Tolerance
R/T-Curve no. // R25
RN
TN
BN
Max power rating at 25°C
P25
Dissipation factor (in air)
Thermal time constant (water)
th
a
Insulation resistance
Voltage proof
Ris
Vis
[ // %] :
[°C] :
[K//%] :
[n//] :
10000 // 1
25
3988 // 1
8016 // 10000
[mW] : 150
[mW/K] : Approx. 3
[s] : Approx. 50
[MΩ] : >100
[V] : 1000
Remarks: --
SEN NTC PD
Please read Cautions and warnings and
Important notes at the end of this document.
2010-05-03
Page 2 of 7
NTC thermistors for temperature measurement
NTC Probes
B57703M0103A039
M703/10K/A39
NTC-RESISTANCE-TEMPERATURE-CURVE
1%
R/T-Curve
= 8016 / A01
B(25/100)
= 3988 K
R at 25°C
= 10000
RN at 25 °C
= 10000 1 %
Temp. [°C]
R Nom
R Min
R Max
R [±%]
-55
-50
-45
-40
-35
-30
-25
-20
-15
-10
-5
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
963048
670100
471687
336500
242589
177000
130370
97070
72929
55330
42315
32650
25388
19900
15708
12490
10000
8057
6531
5327
4369
3603
2986
2488
2083
1752
1481
1258
1072
917,7
788,5
680,0
588,6
511,2
445,4
389,3
341,7
905697
632939
447377
320419
231867
169786
125487
93743
70652
53765
41237
31907
24877
19550
15470
12330
9900
7955
6434
5237
4286
3528
2918
2427
2028
1703
1437
1219
1037
886,1
760,2
654,6
565,8
490,7
426,9
372,6
326,6
1020399
707261
495998
352582
253311
184214
135252
100397
75206
56895
43393
33393
25898
20250
15946
12650
10100
8159
6628
5417
4451
3678
3054
2549
2138
1801
1525
1297
1108
949,3
816,9
705,4
611,4
531,7
463,9
406,0
356,8
6,0
5,5
5,2
4,8
4,4
4,1
3,7
3,4
3,1
2,8
2,5
2,3
2,0
1,8
1,5
1,3
1,0
1,3
1,5
1,7
1,9
2,1
2,3
2,5
2,6
2,8
3,0
3,1
3,3
3,4
3,6
3,7
3,9
4,0
4,2
4,3
4,4
SEN NTC PD
Please read Cautions and warnings and
Important notes at the end of this document.
2010-05-03
Page 3 of 7
NTC thermistors for temperature measurement
NTC Probes
B57703M0103A039
M703/10K/A39
RELIABILITY DATA :
Test
Test conditions
R25/R25
(typical)
Remarks
Storage in
dry heat
Storage at upper category temperature
T: 125 °C
t: 1000 h
< 1%
No visible
damage
Storage in damp
heat, steady
state
Temperature of air: 40 °C
Relative humidity of air: 93%
Duration: 56 days
< 1%
No visible
damage
Rapid
temperature
cycling
Lower test temperature: - 55 °C
Upper test temperature: +125 °C
Dwelling time : 10 minute, travel time : 30 second
Number of cycles: 10