NTC thermistors for
temperature measurement
Miniature sensors
with bendable wires
Series/Type:
B57867S
Date:
January 2018
© EPCOS AG 2018. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
Temperature measurement
B57867S
Miniature sensors with bendable wires
S867
Applications
Temperature measurement
Dimensional drawing
Features
Short response time
High measuring accuracy
Different tolerances available
Epoxy encapsulation
Silver-plated nickel leads
UL approval (E69802)
Options
Alternative lead lengths on request
Delivery mode
Bulk
Dimensions in mm
Approx. weight 60 mg
General technical data
Climatic category
Max. power
Resistance tolerance
Rated temperature
Dissipation factor
Thermal cooling time constant
Heat capacity
(IEC 60068-1)
(at 25 °C)
(in air)
(in air)
P25
∆RR/RR
TR
δth
τc
Cth
55/155/56
60
±1, ±3, ±5
25
approx. 1.5
approx. 12
approx. 18
mW
%
°C
mW/K
s
mJ/K
Electrical specification and ordering codes
R25
Ω
2k
3k
5k
10 k
30 k
50 k
No. of R/T
characteristic
1038
8016
8016
8016
8018
2901
B25/100
K
3560 ±1%
3988 ±1%
3988 ±1%
3988 ±1%
3964 ±1%
3760 ±1%
+ = Resistance tolerance
F = ±1%
H = ±3%
J = ±5%
Please read Cautions and warnings and
Important notes at the end of this document.
Page 2 of 23
Ordering code
B57867S0202+141
B57867S0302+140
B57867S0502+140
B57867S0103+140
B57867S0303+140
B57867S0503+140
Temperature measurement
B57867S
Miniature sensors with bendable wires
S867
Reliability data
Test
Standard
Storage in
dry heat
IEC
60068-2-2
Storage in damp
heat, steady state
Rapid temperature
cycling
Endurance
Long-term stability
(empirical value)
Test conditions
Storage at upper
category temperature
T: 155 °C
t: 1000 h
IEC
Temperature of air: 40 °C
60068-2-78 Relative humidity of air: 93%
Duration: 56 days
IEC
Lower test temperature: 55 °C
60068-2-14 Upper test temperature: 155 °C
Number of cycles: 100
Pmax: 60 mW
t: 1000 h
Temperature: 70 °C
t: 10000 h
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 23
∆R25/R25
(typical)
< 2%
Remarks
< 1%
No visible
damage
< 1%
No visible
damage
< 3%
No visible
damage
No visible
damage
< 2%
No visible
damage
Temperature measurement
B57867S
Miniature sensors with bendable wires
S867
Reliability data according to AEC-Q200, Rev. D
Test
Standard
High temperature
exposure (storage)
Biased humidity
MIL-STD-202,
method 108
MIL-STD-202,
method 103
Operational life
Temperature
cycling
Terminal strength
(leaded)
Test conditions
Storage at T = +125 °C
t = 1000 h
T = 85 °C
Relative humidity of air 85%
t = 1000 h
Test voltage max. 0.3 V DC on
NTC1)
MIL-STD-202, T = +125 °C
method 108
t = 1000 h
Test voltage max. 0.3 V DC on
NTC1)
JESD 22,
Lower test temperature: 55 °C
method JA-104 Upper test temperature: 125 °C
1000 cycles
Dwell time: max. 30 min at each
temperature
Transition time in air: max. 1 min
MIL-STD-202, Test leaded device integrity
method 211
Condition A: 2.27 N2)
Mechanical shock
MIL-STD-202,
method 213,
condition C
Vibration
MIL-STD-202,
method 204
Acceleration: 40 g 2)
Pulse duration: 6 ms
Number of bumps: 3, each
direction
Acceleration: 5 g
t = 20 min
12 cycles in each of 3 directions
Frequency range: 10 ... 2000 Hz
∆R25/R25
(typical)
< 2%