B58620S3300B360

B58620S3300B360

  • 厂商:

    TDK(东电化)

  • 封装:

    SENSOR_4.3X4.3MM_SM

  • 描述:

    PRESSURE SENSOR ABSOLUTE 17.4PSI

  • 详情介绍
  • 数据手册
  • 价格&库存
B58620S3300B360 数据手册
Pressure sensors Barometric pressure transmitters for SMT Series/Type: Ordering code: ASB series Date: Version: 2011-11-10 2.4 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the color to "white". This ensures that the table disappears (invisible) for the customer PDF. Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it! Identification/Classification 1 (header 1 + top left bar): Pressure sensors Identification/Classification 2 (header 2 + bottom left header bar): Barometric pressure transmitters for SMT Ordering code: (top right header bar) Series/Type: (top right header bar) ASB series Preliminary data (optional): (if necessary) Preliminary data Department: SEN PS PD T Date: 2011-11-10 Version: 2.4 released / signed: PD Hundertmark  EPCOS AG 2009. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited Pressure sensors Barometric pressure transmitters for SMT ASB series Preliminary data Description  Pressure sensor transmitters based on piezoresistive silicon pressure dies  On board compensation circuit for non-linearity and temperature error  Miniaturized SMD hybrid package (4.3mm x 4.3mm x 2.4mm) Features  Analog ratiometric or fixed voltage interface with adjustable output limits (clipping)  Diagnosis functions like loss of Vdd/Vss, bridge connections and short cuts  High immunity against electromagnetic influences  Plastic free surface mount technology for reflow soldering  Conforming to RoHS Directive Options  Other output characteristics and / or rated pressure ranges upon request Table of Contents 1. Technical Data .........................................................................................................3 2. Analog Output (VR/V1) ............................................................................................4 3. Digital Output – I²C (D5) ..........................................................................................5 4. Total Error (Temperature Error Multiplier) ................................................................9 5. Board Layout (Recommendation) .............................................................................9 6. Reliability Testing ...................................................................................................10 7. Product Key............................................................................................................11 8. Ordering Codes ......................................................................................................11 9. Packaging...............................................................................................................12 10. Reflow Soldering ....................................................................................................13 Symbols and terms........................................................................................................14 Cautions and warnings ..................................................................................................15 SEN PS PD T Please read Cautions and warnings and Important notes at the end of this document. 2011-11-10 Page 2 of 12 Pressure sensors Barometric pressure transmitters for SMT ASB series Preliminary data 1. Technical Data Absolute maximum ratings Parameter Symbol Conditions Min. Max. Unit Tst 1) Temperature ranges Storage temperature range Operating temperature range Top Tc Soldering temperature Tsolder +125 °C -40 +85 °C 2) -40 +125 °C 0 +70 °C +260 °C TN TE Compensated temperature range -40 2) 3),4) Pressure ranges Rated pressure Overpressure pr absolute 0.2 (2.9) pov 4), 5) 2 pr 3 pr Burst pressure 1.2 (17.4) bar (psi) Supply voltage /-current Supply voltage Vsupply Supply current Isupply Signal output current Start up time 6) 5.5 V Iout = 0 2.5 mA Iout 7) 2 mA tSTA 8) 10 ms SEN PS PD T Please read Cautions and warnings and Important notes at the end of this document. 2.7 2011-11-10 Page 3 of 12 Pressure sensors Barometric pressure transmitters for SMT ASB series Preliminary data 2. Analog Output (VR/V1) Parameter Symbol Conditions Min. Typ. Max. Unit Analog output signal (VR/V1) @ Top = 25°C, Vsupply = 5 V, Iout < 0.1 mA Offset (at pr,min) Vout,0 VR: ratiometric V1: 0 … 1000 mV VR: ratiometric Signal span (Full Scale) 9) V1: 0 … 1000 mV Vout,0 + VFS 10) 9), 10) 10 %VCC 2.5 mV 80 %VCC 1000 mV 90 %VCC enabled upon request Diagnostic levels Non-linearity Response time Resolution Basic accuracy Terminal assignment disabled 10), 11) L Simple output ±0.1 % FS t10-90 12) 2 ms rOUT 13) 12 bit Top: 0 … 70°C ±2 ±3 % FS Dimensional drawings Pin Symbol Signal 1 2 3 4 not connected Ground Output signal Supply voltage GND Vout Vsupply VR: ratiometric 0 10) VFS Full scale output at pr,max 9) Output Characteristics Application Circuit Vout,min + VFS Vsupply Vout,min pr,min 2 3 1 4 Vout pr,max Conversion Formula  − pr ,min )  Vmeas ⋅ − Vout ,min  + p r ,min   VFS  VSupply  ( p r ,max − pr ,min ) = ⋅ (Vmeas − Vout ,min ) + p r ,min VFS VR: p meas = V1 p meas (p r , max SEN PS PD T Please read Cautions and warnings and Important notes at the end of this document. 0.1µF GND 2011-11-10 Page 4 of 12 Pressure sensors Barometric pressure transmitters for SMT ASB series Preliminary data 3. Total Error (Temperature Error Multiplier) The output accuracy over the whole temperature range can be calculated by multiplying the basic accuracy with a temperature dependant factor as shown in the following graph. Temperature error multiplier 2,0 1,9 1,8 1,7 1,6 1,5 Temperature error multiplier 1,4 1,3 1,2 1,1 1,0 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0,2 0,1 125 120 115 110 105 95 100 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 5 10 0 -5 -10 -15 -20 -25 -30 -35 -40 0,0 Temperature [°C] 4. Board Layout (Recommendation) SEN PS PD T Please read Cautions and warnings and Important notes at the end of this document. 2011-11-10 Page 5 of 12 Pressure sensors Barometric pressure transmitters for SMT ASB series Preliminary data 5. Reliability Testing Test Criterion: All sensors have to be within the specified tolerances (refer to chapters 1 – 4) before and after each test listed below. Performed Tests: Test Standard Test conditions Early Life Failure Rate (ELFR) following to AEC-Q100-008 - Storage for 24h at +105°C Preconditioning (PC) following to AEC-Q100, JEDEC J-STD-020 and JEDEC JESD22-A113 - Parts from ELFR test - 5 cycles shipping conditions (-40°C to +60°C) - Bake 24h at +125°C - Soak 192h at +30°C and 60% r.h. - Apply 3 reflow soldering cycles High Temperature Storage Life (HTSL) following to AEC-Q100 and JEDEC JESD22-A103 - Parts from PC test - Storage for 1000h at +125°C - Unpowered High Temperature Operating Life (HTOL) following to AEC-Q100 and JEDEC JESD22-A108 - Parts from ELFR test - Operating for 408h at +105°C - Powered with Vsupply at +5VDC Variable Frequency Vibration Test (VFV) following to AEC-Q100 and JEDEC JESD22-B103 - Parts from ELFR test - Logarithmic sweep from 20Hz to 2KHz to 20Hz within 4min - Max. acceleration at 50g - 4 x 4min in each orientation (total 144min) Mechanical Shock Test (MS) following to AEC-Q100 and JEDEC JESD22-B104 - Parts from ELFR test - 5 pulses with 1,500g peak acceleration in positive vertical direction - Peak duration 0.5ms Pressure Cycle Test (Internal standard) - Parts from ELFR test - 1,000,000 pressure cycles between minimum rated pressure (pr,min) and overpressure (pov) - Test performed at room temperature SEN PS PD T Please read Cautions and warnings and Important notes at the end of this document. 2011-11-10 Page 6 of 12 Pressure sensors Barometric pressure transmitters for SMT ASB series Preliminary data 6. Product Key AS B 1.200 VR TN H19 KXXXX Customer Specific Index Optional, reserved Pressure Feed Reserved Operating Temperature Range TN TE Normal Temp. Range (-40°C … +85°C) Extended Temp. Range (-40°C … +125°C)* *only available upon request Output signal VR V1 Rated pressure range 0.1 ... 0.9 V/V (ratiometrical) 0 ... 1 V 1.200 bar (17.4 psi) Measuring type B Barometric (Absolute) Sensor type AS Advanced Surface Mount Technology 8. Ordering Codes Rated Pressure pr [bar] ([psi]) 1.200 Normal Temperature Range Ratiometric 0..1000 mV Samples available upon request (17.4) I²C (14 bit) Ratiometric 0..1000 mV I²C (14 bit) B58620S3300B362 B58620S3300B365 B58620S3300B366 B58620S3300B367 (ASB 1.200 D5 TN H19) (ASB 1.200 VR TE H19) (ASB 1.200 V1 TE H19) (ASB 1.200 D5 TE H19) SEN PS PD T Please read Cautions and warnings and Important notes at the end of this document. Extended Temperature Range 2011-11-10 Page 7 of 12 Pressure sensors Barometric pressure transmitters for SMT ASB series Preliminary data 9. Packaging Packaging for samples is separated in ESD bags and ESD box. (Tape and reel packaging acc. to IEC 60286-3 will be defined.) SEN PS PD T Please read Cautions and warnings and Important notes at the end of this document. 2011-11-10 Page 8 of 12 Pressure sensors Barometric pressure transmitters for SMT ASB series Preliminary data 10. Reflow soldering Recommended temperature characteristic for reflow soldering following JEDEC J-STD-020D Profile feature Sn-Pb eutectic assembly Pb-free assembly Preheat and soak - Temperature min Tsmin 100 °C 150 °C - Temperature max Tsmax 150 °C 200 °C - Time tsmin to tsmax 60 … 120 s 60 … 180 s Average ramp-up rate Tsmax to Tp 3 °C/s max. 3 °C/s max. Liquidous temperature TL 183 °C 217 °C Time at liquidous tL Peak package body temperature Tp 60 … 150 s A) 220 °C … 235 °C 3) Time (tp) within 5 °C of specified classification temperature (Tc) Average ramp-down rate Time 25 °C to peak temperature 20 s Tp to Tsmax C) 60 … 150 s B) 245 °C … 260 °C 30 s B) C) 6 °C/s max. 6 °C/s max. maximum 6 min maximum 8 min A) Tolerance for peak profile temperature (Tp) is defined as a supplier minimum and a user maximum. B) Depending on package thickness. For details please refer to JEDEC J-STD-020D. C) Tolerance for time at peak profile temperature (tp) is defined as a supplier minimum and a user maximum. SEN PS PD T Please read Cautions and warnings and Important notes at the end of this document. 2011-11-10 Page 9 of 12 Pressure sensors Barometric pressure transmitters for SMT ASB series Preliminary data Symbols and terms 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) Storage temperature range Tst A storage of the pressure sensor within the temperature range Tst,min up to Tst,max and without applied pressure and supply voltage will not affect the performance of the pressure sensor. Operating temperature range Top An operation of the pressure sensor within the temperature range Top,min up to Top,max will not affect the performance of the pressure sensor. Compensated temperature range Tc While operating the pressure sensor within the temperature range Tc,min up to Tc,max, the deviation of the output signal from the values at 25 °C will not exceed the temperature coefficients. Out of the compensated temperature range, the deviations may increase. Rated pressure pr Within the rated pressure range 0 up to pr,max the signal output characteristic corresponds to this specification. Overpressure pOV Pressure cycles within the pressure range 0 up to pov will not affect the performance of the pressure sensor. Supply voltage Vsupply Vsupply,max is the maximum permissible supply voltage, which can be applied without damages. Vsupply,min is the minimum required supply voltage, which has to be applied for normal operation. Signal output current IA IA,max is the maximum permissible sink current of the signal output. Exceeding (e.g. short circuit) may cause irreparable damages. Start up time tSTA Time between the start up of the normal operation after power on and the first valid output signal. Offset Vout,0 The offset Vout,0 is the signal output VA(p = 0) at zero pressure. Signal span (Full Scale) Simple output: VFS = FS = Vout(pr,max) – VA0 Non-linearity L (including pressure hysteresis) The non-linearity is the deviation of the real sensor characteristic VA = f(p) from the ideal straight line. It can be approximated by a polynomial of second order, with the maximum at px = pr / 2 . The equation to calculate the non-linearity is: L= 12) 13) Vout ( p x ) − Vout , 0 p x − Vout ( pr ) − Vout , 0 pr Response time t10-90 Delay between a pressure change (10 ... 90% pr) and the corresponding signal output change (10 ... 90% FS). Resolution rOUT The resolution of the output DAC (digital/analog converter). For ratiometric output only 80% of DAC range is used. SEN PS PD T Please read Cautions and warnings and Important notes at the end of this document. 2011-11-10 Page 10 of 12 Pressure sensors Barometric pressure transmitters for SMT ASB series Preliminary data Cautions and warnings Storage The pressure sensors should be stored in their original packaging. They should not be placed in harmful environments such as corrosive gases nor exposed to heat or direct sunlight, which may cause deformations. Similar effects may result from extreme storage temperatures and climatic conditions. Avoid storing the pressure sensors in an environment where condensation may form or in a location exposed to corrosive gases, which will adversely affect their performance. Soldering The thermal capacity of the pressure sensor is normally low, so steps should be taken to minimize the effects of external heat. High temperatures may lead to damage or changes in characteristics. A no-clean flux should normally be used. Flux removal processes are not recommended. Avoid rapid cooling due to dipping in solvent. Note that the output signal may change if pressure is applied to the terminals during soldering. Operation Media compatibility with the pressure sensors must be ensured to prevent their failure (see page 2). The use of other media can cause damage and malfunction. Never use them in atmospheres containing explosive liquids or gases. Ensure pressure equalization to the environment, if relative pressure sensors are used. Avoid operating the pressure sensors in an environment where condensation may form or in a location exposed to corrosive gases. These environments adversely affect their performance. If the operating pressure is not within the rated pressure range, it may change the output characteristics. Be sure that the applicable pressure does not exceed the overpressure, it may damage the pressure sensor. Do not exceed the maximum rated supply voltage, it may damage the pressure sensor. Do not exceed the rated storage temperature range, it may damage the pressure sensor. Temperature variations in both the ambient conditions and the media (liquid or gas) can affect the accuracy of the output signal from the pressure sensors. Be sure to check the operating temperature range and thermal error specification of the pressure sensors to determine their suitability for the application. Connections must be wired in accordance with the terminal assignment specified in this publication. Care should be taken as reversed pin connections can damage the pressure sensors or degrade their performance. Contact between the pressure sensor terminals and metals or other materials may cause errors in the output characteristics. This listing does not claim to be complete, but merely reflects the experience of EPCOS AG. SEN PS PD T Please read Cautions and warnings and Important notes at the end of this document. 2011-11-10 Page 11 of 12 Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DSSP, MiniBlue, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. Page 12 of 12
B58620S3300B360
物料型号:EPCOS ASB系列

器件简介: - 基于压阻式硅压力芯片的气压传感器变送器。 - 板上补偿电路用于非线性和温度误差补偿。 - 微型SMD混合封装(4.3mm x 4.3mm x 2.4mm)。

引脚分配: - 1: 未连接 - 2: GND(地) - 3: Vout(输出信号) - 4: Vsupply(供电电压)

参数特性: - 工作温度范围:-40°C 至 +85°C(标准)或 -40°C 至 +125°C(扩展) - 额定压力范围:0.2 至 1.2 bar - 供电电压:2.7V 至 5.5V - 供电电流:在输出电流为0时最大2.5mA - 信号输出电流:最大2mA - 启动时间:10ms

功能详解: - 提供模拟比例或固定电压接口,具有可调节的输出限制(裁剪)。 - 诊断功能,如Vdd/Vss丢失、桥接和短路。 - 高电磁干扰抗性。 - 符合RoHS指令的无塑料表面贴装技术。

应用信息: - 可用于需要气压测量的各种应用,如气象站、高度计等。

封装信息: - 封装类型:SMD - 封装尺寸:4.3mm x 4.3mm x 2.4mm

注意事项: - 存储和操作时应避免高温、有害气体和直接日晒。 - 焊接时应使用无清洗助焊剂,避免快速冷却。 - 确保介质兼容性,避免在有爆炸性液体或气体的环境中使用。 - 确保压力传感器在额定压力范围内工作,不要超过最大额定供电电压。
B58620S3300B360 价格&库存

很抱歉,暂时无法提供与“B58620S3300B360”相匹配的价格&库存,您可以联系我们找货

免费人工找货