PTC thermistors
Series/Type:
D901
The following products presented in this data sheet are being withdrawn.
Ordering Code
Substitute Product
B59901D0120A040
B59901D0110A040
B59901D0100A040
B59052D1120A040
B59052D1110A040
B59052D1100A040
Date of
Withdrawal
2019-03-01
2019-03-01
2019-03-01
Deadline Last
Orders
2019-06-07
2019-06-07
2019-06-07
Last
Shipments
2019-09-07
2019-09-07
2019-09-07
Ordering Code
Substitute Product
B59901D0090A040
B59901D0080A040
B59901D0070A040
B59901D0060A040
B59052D1090A040
B59052D1080A040
B59052D1070A040
B59052D1060A040
Date of
Withdrawal
2019-03-01
2019-03-01
2019-03-01
2019-03-01
Deadline Last
Orders
2019-06-07
2019-06-07
2019-06-07
2019-06-07
Last
Shipments
2019-09-07
2019-09-07
2019-09-07
2019-09-07
Please contact your nearest TDK sales office if you need support in selecting a suitable
substitute. The addresses of our worldwide sales network are presented at www.tdkelectronics.tdk.com/sales.
Sensors
Limit temperature sensors, probe assemblies
D901, D1052
Applications
Limit temperature sensor
Dimensional drawings
Type D1052
Features
Sensor with epoxy resin coating
Tinned leads
Metal tag for easy mounting
Characteristics for sensing temperatures
Tsense = 90 to 120 °C conform with DIN 44081
Metal tag permits good thermal coupling and
thus short response time
Marking type D1052: Type, manufacturer's
logo, Tsense temperature in °C and date code
YYWW
Marking type D901: Three digits stamped on
to identify Tsense
RoHS-compatible
Type D901
Delivery mode
Type D1052: Cardboard strips with hot-melt
adhesive tape in cardboard box (800 pcs.)
Type D901: Cardboard strips with manila
paper strips in cardboard box (500 pcs.)
Dimensions in mm
General technical data
Max. operating voltage
Measuring voltage1)
Max. measuring voltage1)
Rated resistance
Insulating test voltage
Operating temperature range
Operating temperature range
(TA = 0 ... 40 °C)
(TA = 40 °C ... Tsense +5 K)
For TA see table "Electrical
specifications"
(VPTC ≤ 2.5 V)
(between tags and leads)
(V ≤ Vmeas,max)
(V = Vmax)
1) Vmeas and Vmeas,max for 90 °C ≤ Tsense ≤ 120 °C acc. to DIN 44081.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 2 of 11
Vmax
Vmeas
Vmeas,max
30
≤ 2.5
7.5
V DC
V DC
V DC
RR
Vins
Top
Top
≤ 100
500
40/ Tsense +23
0/+40
Ω
V AC
°C
°C
Sensors
Limit temperature sensors, probe assemblies
D901, D1052
Electrical specifications and ordering codes
Tsense
°C
R
(Tsense 5 K)
(VPTC ≤ 2.5 V)
Ω
Type D1052
60
≤ 570
70
≤ 570
80
≤ 570
90
≤ 550
Type D901
60
≤ 570
70
≤ 570
80
≤ 570
90
≤ 550
100
≤ 550
110
≤ 550
120
≤ 550
R
(Tsense + 5 K)
(VPTC ≤ 2.5 V)
Ω
R
(Tsense + 15 K)
(VPTC ≤ 7.5 V)
Ω
R
Stamp Ordering code
(Tsense + 23 K) code
(VPTC ≤ 7.5 V)
Ω
≥ 570
≥ 570
≥ 570
≥ 1330
≥4k
≥ 10 k
≥ 10 k
≥ 10 k
-
-
B59052D1060A040
B59052D1070A040
B59052D1080A040
B59052D1090A040
≥ 570
≥ 570
≥ 570
≥ 1330
≥ 1330
≥ 1330
≥ 1330
≥4k
≥4k
≥4k
≥4k
≥ 10 k
≥ 10 k
≥ 10 k
-
331
341
351
361
371
381
391
B59901D0060A040
B59901D0070A040
B59901D0080A040
B59901D0090A040
B59901D0100A040
B59901D0110A040
B59901D0120A040
Reliability data
Test
Electrical endurance,
constant
Damp heat
Standard
IEC 60738-1
Rapid change
of temperature
IEC 60738-1
Vibration
IEC 60738-1
IEC 60738-1
Please read Cautions and warnings and
Important notes at the end of this document.
Test conditions
Storage at Vmax and Top,max (@ Vmax)
Test duration: 1000 h
Temperature of air: 40 °C
Relative humidity of air: 93%
Duration: 56 days
Test according to IEC 60068-2-78
T1 = Top,min (0 V), T2 = Top,max (0 V)
Number of cycles: 5
Test duration: 30 min
Test according to IEC 60068-2-14, test Na
Frequency range: 10 to 55 Hz
Displacement amplitude: 0.75 mm
Test duration: 3 × 2 h
Test according to IEC 60068-2-6, test Fc
Page 3 of 11
∆R25/R25
< 25%
< 10%
< 25%
< 5%
Sensors
Limit temperature sensors, probe assemblies
Characteristics (typical) for type D1052
PTC resistance RPTC versus
PTC temperature TPTC (measured at low signal voltage)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 4 of 11
D901, D1052
Sensors
Limit temperature sensors, probe assemblies
Characteristics (typical) for type D901
PTC resistance RPTC versus
PTC temperature TPTC (measured at low signal voltage)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 5 of 11
D901, D1052
Sensors
Limit temperature sensors, probe assemblies
D901, D1052
Cautions and warnings
General
EPCOS thermistors are designed for specific applications and should not be used for purposes
not identified in our specifications, application notes and data books unless otherwise agreed
with EPCOS during the design-in-phase.
Ensure suitability of thermistor through reliability testing during the design-in phase. The thermistors should be evaluated taking into consideration worst-case conditions.
Storage
Store thermistors only in original packaging. Do not open the package prior to processing.
Storage conditions in original packaging: storage temperature 25 °C ... +45 °C, relative humidity ≤75% annual mean, maximum 95%, dew precipitation is inadmissible.
Avoid contamination of thermistors surface during storage, handling and processing.
Avoid storage of thermistor in harmful environment with effect on function on long-term operation (examples given under operation precautions).
Use thermistor within the following period after delivery:
Through-hole devices (housed and leaded PTCs): 24 months
Motor protection sensors, glass-encapsulated sensors and probe assemblies: 24 months
Telecom pair and quattro protectors (TPP, TQP): 24 months
Leadless PTC thermistors for pressure contacting: 12 months
Leadless PTC thermistors for soldering: 6 months
SMDs in EIA sizes 3225 and 4032, and for PTCs with metal tags: 24 months
SMDs in EIA sizes 1210 and smaller: 12 months
Handling
PTCs must not be dropped. Chip-offs must not be caused during handling of PTCs.
The ceramic and metallization of the components must not be touched with bare hands. Gloves
are recommended.
Avoid contamination of thermistor surface during handling.
Soldering (where applicable)
Use rosin-type flux or non-activated flux.
Insufficient preheating may cause ceramic cracks.
Rapid cooling by dipping in solvent is not recommended.
Complete removal of flux is recommended.
Standard PTC heaters are not suitable for soldering.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 6 of 11
Sensors
Limit temperature sensors, probe assemblies
D901, D1052
Mounting
Electrode must not be scratched before/during/after the mounting process.
Contacts and housing used for assembly with thermistor have to be clean before mounting. Especially grease or oil must be removed.
When PTC thermistors are encapsulated with sealing material, the precautions given in chapter
"Mounting instructions", "Sealing and potting" must be observed.
When the thermistor is mounted, there must not be any foreign body between the electrode of
the thermistor and the clamping contact.
The minimum force and pressure of the clamping contacts pressing against the PTC must be
10 N and 50 kPa, respectively. In case the assembly is exposed to mechanical shock and/ or
vibration this force should be higher in order to avoid movement of the PTC during operation.
During operation, the thermistor’s surface temperature can be very high. Ensure that adjacent
components are placed at a sufficient distance from the thermistor to allow for proper cooling at
the thermistors.
Ensure that adjacent materials are designed for operation at temperatures comparable to the
surface temperature of thermistor. Be sure that surrounding parts and materials can withstand
this temperature.
Avoid contamination of thermistor surface during processing.
Operation
Use thermistors only within the specified temperature operating range.
Use thermistors only within the specified voltage and current ranges.
Environmental conditions must not harm the thermistors. Use thermistors only in normal atmospheric conditions. Avoid use in deoxidizing gases (chlorine gas, hydrogen sulfide gas, ammonia gas, sulfuric acid gas etc), corrosive agents, humid or salty conditions. Contact with any
liquids and solvents should be prevented.
Be sure to provide an appropriate fail-safe function to prevent secondary product damage
caused by abnormal function (e.g. use VDR for limitation of overvoltage condition).
This listing does not claim to be complete, but merely reflects the experience of EPCOS AG.
Display of ordering codes for EPCOS products
The ordering code for one and the same EPCOS product can be represented differently in data
sheets, data books, other publications, on the EPCOS website, or in order-related documents
such as shipping notes, order confirmations and product labels. The varying representations of
the ordering codes are due to different processes employed and do not affect the
specifications of the respective products. Detailed information can be found on the Internet
under www.epcos.com/orderingcodes
Please read Cautions and warnings and
Important notes at the end of this document.
Page 7 of 11
Sensors
Limit temperature sensors, probe assemblies
Symbols and terms
Symbol
A
C
Cth
f
I
Imax
IR
Ires
IPTC
Ir
Ir,oil
Ir,air
IRMS
IS
ISmax
LCT
N
Nc
Nf
P
P25
Pel
Pdiss
RG
Rmin
RR
∆RR
RP
RPTC
Rref
RS
R25
R25,match
∆R25
Term
Area
Capacitance
Heat capacity
Frequency
Current
Maximum current
Rated current
Residual current
PTC current
Residual currrent
Residual currrent in oil (for level sensors)
Residual currrent in air (for level sensors)
Root-mean-square value of current
Switching current
Maximum switching current
Lower category temperature
Number (integer)
Operating cycles at Vmax, charging of capacitor
Switching cycles at Vmax, failure mode
Power
Maximum power at 25 °C
Electrical power
Dissipation power
Generator internal resistance
Minimum resistance
Rated resistance @ rated temperature TR
Tolerance of RR
Parallel resistance
PTC resistance
Reference resistance
Series resistance
Resistance at 25 °C
Resistance matching per reel/ packing unit at 25 °C
Tolerance of R25
Please read Cautions and warnings and
Important notes at the end of this document.
Page 8 of 11
D901, D1052
Sensors
Limit temperature sensors, probe assemblies
T
t
TA
ta
TC
tE
TR
Tsense
Top
TPTC
tR
Tref
TRmin
tS
Tsurf
UCT
V or Vel
Vc(max)
VF,max
VRMS
VBD
Vins
Vlink,max
Vmax
Vmax,dyn
Vmeas
Vmeas,max
VR
VPTC
α
∆
δth
τth
λ
Temperature
Time
Ambient temperature
Thermal threshold time
Ferroelectric Curie temperature
Settling time (for level sensors)
Rated temperature @ 25 °C or otherwise specified in the data sheet
Sensing temperature
Operating temperature
PTC temperature
Response time
Reference temperature
Temperature at minimum resistance
Switching time
Surface temperature
Upper category temperature
Voltage (with subscript only for distinction from volume)
Maximum DC charge voltage of the surge generator
Maximum voltage applied at fault conditions in protection mode
Root-mean-square value of voltage
Breakdown voltage
Insulation test voltage
Maximum link voltage
Maximum operating voltage
Maximum dynamic (short-time) operating voltage
Measuring voltage
Maximum measuring voltage
Rated voltage
Voltage drop across a PTC thermistor
Temperature coefficient
Tolerance, change
Dissipation factor
Thermal cooling time constant
Failure rate
Lead spacing (in mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 9 of 11
D901, D1052
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application. As a
rule we are either unfamiliar with individual customer applications or less familiar with them than
the customers themselves. For these reasons, it is always ultimately incumbent on the customer
to check and decide whether a product with the properties described in the product specification is
suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or failure
before the end of their usual service life cannot be completely ruled out in the current state
of the art, even if they are operated as specified. In customer applications requiring a very high
level of operational safety and especially in customer applications in which the malfunction or
failure of an electronic component could endanger human life or health (e.g. in accident
prevention or life-saving systems), it must therefore be ensured by means of suitable design of the
customer application or other action taken by the customer (e.g. installation of protective circuitry
or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or
failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Material
Data Sheets on the Internet (www.tdk-electronics.tdk.com/material). Should you have any more
detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products. Consequently,
we cannot guarantee that all products named in this publication will always be available.
The aforementioned does not apply in the case of individual agreements deviating from the
foregoing for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to our General Terms
and Conditions of Supply.
7. Our manufacturing sites serving the automotive business apply the IATF 16949 standard.
The IATF certifications confirm our compliance with requirements regarding the quality
management system in the automotive industry. Referring to customer requirements and
customer specific requirements (“CSR”) TDK always has and will continue to have the policy of
respecting individual agreements. Even if IATF 16949 may appear to support the acceptance of
unilateral requirements, we hereby like to emphasize that only requirements mutually agreed
upon can and will be implemented in our Quality Management System. For clarification
purposes we like to point out that obligations from IATF 16949 shall only become legally binding if
individually agreed upon.
Page 10 of 11
Important notes
8. The trade names EPCOS, CeraCharge, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CTVS,
DeltaCap, DigiSiMic, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue, MiniCell, MKD, MKK,
MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PowerHap, PQSine, PQvar,
SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, ThermoFuse,
WindCap are trademarks registered or pending in Europe and in other countries. Further
information will be found on the Internet at www.tdk-electronics.tdk.com/trademarks.
Release 2018-10
Page 11 of 11