RF chokes LBC series, 5.2 s 12 (mm)
LBC choke (Large Bobbin Core) Rated inductance 1 NH to 100 000 NH Rated current 20 mA to 2200 mA Construction
■ Large ferrite drum core ■ Winding: enamel copper wire ■ Flame-retardant lacquer coating
B82144A
Features
■ ■ ■ ■
Very wide inductance range High rated current Suitable for wave soldering RoHS-compatible
Applications
■ RF blocking and filtering ■ Decoupling and interference suppression ■ For telecommunications (12- or 16-kHz blocking filter),
automotive electronics, energy-saving lamps, entertainment electronics Terminals
■ Central axial leads ■ Base material CuAg0.1 ■ Hot-dipped with pure tin
Marking Inductance indicated by color bands to IEC 60062 Delivery mode and packing units
■ Taped, Ammo and reel packing ■ Packing units:
Ammo (pcs./pack.) Axial 1250
Reel (pcs./reel) 1500
Please read C autions and warnings and Important notes at the end of this document.
2
03/08
RF chokes LBC series, 5.2 s 12 (mm)
Dimensional drawing
65±1 53±2 65±1 53±2
B82144A
ø0.8 max. ø0.8 max. ø5.2 max. ø4 max.
12 max. (IEC 60294) 9.2 max.
(IEC 60294)
6±0.5
5±0.25 5±0.25 10±0.25 10±0.25
6±0.5
3.5 min. 3.5 min.
11.5 max. 14.8 max. lacquered lacquered
IND0429-B-E IND0431-4-E
Dimensions in mm Minimum lead spacing 15 mm
Packing
ø30.5±0.15 ø82+1 ø90
30
ø360 _ 1
30
H
n w
Label
30
IND0452-V-E
L W
IND0635-W-E
n (mm): 72 +1 w (mm): 84 max
L × W × H (max. mm): 265 × 75 × 125
Dimensions in mm
Please read C autions and warnings and Important notes at the end of this document.
3
03/08
RF chokes LBC series, 5.2 s 12 (mm)
Technical data and measuring conditions Rated inductance LR
B82144A
Measured with LCR meter Agilent 4284A or impedance analyzer Agilent 4294A = 1 MHz Measuring frequency: LR ≤ 10 μ H 10 μH < LR ≤ 4700 μH = 100 kHz = 10 kHz LR > 4700 μH Measuring current: ≤ 1 mA Measuring temperature: 20 °C Measured with precision impedance analyzer Agilent 4294A, 20 °C 40 °C Maximum permissible DC current at rated temperature ≤ 10% (referred to initial value) at IR, 20 °C Measured at 20 °C Sn95.5Ag3.8Cu0.7: (245 ±5) °C, (3 ±0.3) s Wetting of soldering area ≥ 90% (to IEC 60068-2-20, test Ta) (260 ±5) °C, 10 s (to IEC 60068-2-20, test Tb) ≥ 20 N (to IEC 60068-2-21, test Ua) 55/125/56 (to IEC 60068-1) Mounted: –55 °C … +125 °C Packaged: –25 °C … +40 °C, ≤ 75% RH Approx. 1.1 g
Q factor Qmin Rated temperature TR Rated current IR Inductance decrease ΔL/L0 DC resistance Rmax Solderability (lead-free)
Resonance frequency fres,min Measured with Agilent 4294A or 8753ES, 20 °C
Resistance to soldering heat Tensile strength of leads Climatic category Storage conditions Weight Mounting information
When bending the leads, take care that the start-of-winding areas at the face ends (protected by glue and lacquer) are not subjected to any mechanical stress.
Please read C autions and warnings and Important notes at the end of this document.
4
03/08
RF chokes LBC series, 5.2 s 12 (mm)
Characteristics and ordering codes LR μH 1.0 1.5 2.2 3.3 4.7 6.8 10 15 22 33 47 68 100 150 220 330 470 680 1000 1500 2200 3300 4700 6800 10000 15000 22000 33000 47000 68000 100000 ±5%
^
B82144A
Tolerance1) ±10%
^
Qmin 40 40 40 40 40 40 60 60 50
fQ MHz 7.96 7.96 7.96 7.96 7.96 7.96 2.52 2.52 2.52 2.52 2.52 2.52 0.796 0.796 0.796 0.796 0.796 0.796 0.252 0.252 0.252 0.252 0.252 0.252 0.0796 0.0796 0.0796 0.0796 0.0796 0.0796 0.0796
IR mA 2200 2100 1900 1750 1600 1500 1400 1250 1100 900 800 700 600 500 400 330 280 240 200 160 120 110 90 80 60 50 40 35 30 25 20
Rmax Ω 0.08 0.09 0.11 0.13 0.16 0.19 0.22 0.28 0.35 0.43 0.50 0.60 0.70 0.90 1.60 1.90 2.50 2.80 3.80 6.00 9.00 12.0 20.0 30.0 42.0 68.0 120 150 230 290 420
fres,min MHz 200 190 140 120 100 80 60 20 12 8.0 5.0 4.5 3.5 3.0 2.4 2.0 1.5 1.3 1.2 1.0 0.8 0.6 0.5 0.4 0.35 0.30 0.26 0.22 0.18 0.15 0.12
Ordering code (reel packing) 2) B82144A2102K000 B82144A2152K000 B82144A2222K000 B82144A2332K000 B82144A2472K000 B82144A2682K000 B82144A2103K000 B82144A2153K000 B82144A2223K000 B82144A2333J000 B82144A2473J000 B82144A2683J000 B82144A2104J000 B82144A2154J000 B82144A2224J000 B82144A2334J000 B82144A2474J000 B82144A2684J000 B82144A2105J000 B82144A2155J000 B82144A2225J000 B82144A2335J000 B82144A2475J000 B82144A2685J000 B82144A2106J000 B82144A2156J000 B82144A2226J000 B82144A2336J000 B82144A2476J000 B82144A2686J000 B82144A2107J000
K
J
40 40 30 50 50 50 50 40 30 60 60 60 60 60 60 50 50 50 50 40 40 30
1) Closer tolerances on request. 2) For Ammo pack the last digit has to be a »9«. Example: B82144A2102K009
Please read C autions and warnings and Important notes at the end of this document.
5
03/08
RF chokes LBC series, 5.2 s 12 (mm)
Characteristics and ordering codes LR μH 980 1450 2600 3050 5330 ±3% A 25 25 20 25 20 Tolerance Qmin fQ MHz IR mA Rmax Ω 3.8 6.0 11.0 12.0 25.0 fres,min MHz
B82144A
Ordering code (reel packing) 1)
For telecommunications in the blocking filter for 12-kHz and 16-kHz counting pulses
^
0.016 0.016 0.012 0.016 0.012
200 140 120 100 90
1.2 1.0 0.7 0.6 0.5
B82144A2984A000 B82144A2145A500 B82144A2265A000 B82144A2305A500 B82144A2535A300
1) For Ammo pack the last digit has to be a »9«. Example: B82144A2336J009
Please read C autions and warnings and Important notes at the end of this document.
6
03/08
RF chokes LBC series, 5.2 s 12 (mm)
Impedance |Z| versus frequency f measured with impedance analyzer Agilent 4294A or S-parameter network analyzer Agilent 8753ES, typical values at 20 °C
10 7 Ω |Z| 10 6 10 5 10 4 10 3 10 2 10
1 IND0131-7
B82144A
Inductance L versus DC load current IDC measured with LCR meter Agilent 4284A, typical values at 20 °C
IND0132-9
100000 µH 10000 µH 1000 µH 100 µH
B82144A
10 5 µH L 10 4
100000 µH 10000 µH
B82144A
10 µH 1 µH
10 3
1000 µH
10 2
100 µH
10 1
10 µH
10 0
_1
1 µH
10 0 5 10
10
6
10
7
10
8
Hz 10 f
9
10
10
_2
10
_1
10 0
A 10 1 I DC
Q factor versus frequency f measured with impedance analyzer Agilent 4294A, typical values at 20 °C
200 B82144A Q 100000 µH 10000 µH 1000 µH 100 µH 10 µH 1 µH
IND0133-R
Current derating Iop/IR versus ambient temperature TA (rated temperature TR = 40 °C)
1.2
IND0552-S-E
Iop IR
1.0
0.8
100
0.6
0.4
0.2
04 10
10 5
10 6
10 7 f
Hz 10 8
0
0
20
40
60
80
100
˚C
TA
140
7
03/08
Cautions and warnings
■ Please note the recommendations in our Inductors data book (latest edition) and in the data
sheets. – Particular attention should be paid to the derating curves given there. – The soldering conditions should also be observed. Temperatures quoted in relation to wave soldering refer to the pin, not the housing.
■ If the components are to be washed varnished it is necessary to check whether the washing
varnish agent that is used has a negative effect on the wire insulation, any plastics that are used, or on glued joints. In particular, it is possible for washing varnish agent residues to have a negative effect in the long-term on wire insulation.
■ The following points must be observed if the components are potted in customer applications:
– Many potting materials shrink as they harden. They therefore exert a pressure on the plastic housing or core. This pressure can have a deleterious effect on electrical properties, and in extreme cases can damage the core or plastic housing mechanically. – It is necessary to check whether the potting material used attacks or destroys the wire insulation, plastics or glue. – The effect of the potting material can change the high-frequency behaviour of the components.
■ Ferrites are sensitive to direct impact. This can cause the core material to flake, or lead to
breakage of the core.
■ Even for customer-specific products, conclusive validation of the component in the circuit can
only be carried out by the customer.
Please read C autions and warnings and Important notes at the end of this document.
8
03/08
Important notes
The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DSSP, MiniBlue, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. 9 03/09