0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
B84134A0025G001

B84134A0025G001

  • 厂商:

    EPCOS

  • 封装:

  • 描述:

    B84134A0025G001 - EMC filters - EPCOS

  • 数据手册
  • 价格&库存
B84134A0025G001 数据手册
EMC filters 4-line filters for installations and systems Rated current 25 and 50 A Series/Type: Date: B84134A, B84134B January 2006  EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet and the information contained therein without EPCOS’ prior express consent is prohibited. 4-line filters for installations and systems Power line filters for 3-phase systems Rated voltage 440/250 V AC, 50/60 Hz Rated current 25 and 50 A Construction ■ 4-line filter ■ Metal case with terminal compartments ■ Screw-type cable fittings for strain relief B84134A, B84134B on line and load side ■ I core chokes ■ One-stage or two-stage Features ■ Insertion loss ≥ 100 dB in the medium frequency range ■ UL approval Applications ■ Power supplies for elevators and industrial installations ■ Medical equipment Terminals ■ Screw terminals Marking Marking on component: Manufacturer’s logo, ordering code, rated voltage, rated current, rated temperature, climatic category, date code Minimum marking on packaging: Manufacturer’s logo, ordering code Please read Cautions and warnings and Important notes at the end of this document. 2 01/06 4-line filters for installations and systems Circuit diagrams B84134A0025G001 (25 A) LINE L1 B84134A, B84134B LOAD L1 ’ L2 L2 ’ L3 L3 ’ N N’ SSB1070-1 B84134B0050G001 (50 A) LINE L1 LOAD L1 ’ L2 L2 ’ L3 L3 ’ N N’ SSB1071-9 Please read Cautions and warnings and Important notes at the end of this document. 3 01/06 4-line filters for installations and systems Technical data and measuring conditions Rated voltage VR Rated current IR Test voltage Vtest Leakage current lleak Climatic category (IEC 60068-1) Approvals 440/250 V AC, 50/60 Hz B84134A, B84134B Referred to 40 °C ambient temperature L/L = line/line L/C = lines/case At 400 V AC, 50 Hz 25/085/21 (–25 °C/+85 °C/21 days damp heat test) UL 1283 Characteristics and ordering codes VR AC V 440/250 IR A 25 50 Vtest L/L (2 s) 1414 V DC 1100 V DC L/C (2 s) 2500 V DC 1100 V DC lleak A < 0.18 < 1.7 Approx. weight kg 12.5 30 Ordering code Approvals B84134A0025G001 B84134B0050G001 × – × = approval granted Please read Cautions and warnings and Important notes at the end of this document. 4 01/06 4-line filters for installations and systems Dimensional drawings B84134A0025G001 (25 A) 430 B84134A, B84134B Cable fitting PG 21 Cable fitting PG 21 470±1 PE M5 x 20 50±0.4 L1 L1’ L3 L3’ 2 N 450 M5 x 15 (4x) PE M5 x 20 N’ 6.6 SSB1072-H-E Please read Cautions and warnings and Important notes at the end of this document. 5 01/06 180±0.2 210±0.5 LINE L2 L2’ 40±0.4 1.5±0.1 98.5 max. 103 max. 4-line filters for installations and systems B84134B0050G001 (50 A) Cover removable (access to terminals) B84134A, B84134B Cable inlet PG 21 to DIN 46320 70 Cable inlet PG 21 220 870 215 220 PE M6 x 25 887 ø10 PE M6 x 23 M6 x 15 (4x) SSB1073-Q-E Please read Cautions and warnings and Important notes at the end of this document. 6 01/06 268±0.5 288 150 4-line filters for installations and systems Insertion loss (typical values at Z = 50 Ω) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) Filters for 25 A 120 dB α 100 SSB1074-Y-E B84134A, B84134B Filters for 50 A 120 dB α 100 SSB1075-7-E Measuring limit Measuring limit 80 80 60 60 40 40 20 B84134A0025G001 0 4 10 10 5 10 6 20 B84134B0050G001 0 10 4 10 5 10 6 10 7 Hz 10 f 8 10 7 Hz 10 8 f Please read Cautions and warnings and Important notes at the end of this document. 7 01/06 EMC filters Cautions and warnings Important information Please read all safety and warning notes carefully before installing the EMC filter and putting it into operation (see ). The same applies to the warning signs on the filter. Please ensure that the signs are not removed nor their legibility impaired by external influences. Death, serious bodily injury and substantial material damage to equipment may occur if the appro­ priate safety measures are not carried out or the warnings in the text are not observed. Using according to the terms The EMC filters may be used only for their intended application within the specified values in low­ voltage networks in compliance with the instructions given in the data sheets and the data book. The conditions at the place of application must comply with all specifications for the filter used. Warnings ■ It shall be ensured that only qualified persons (electricity specialists) are engaged on work such ■ ■ ■ ■ as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. Danger of electric shock. EMC filters contain components that store an electric charge. Danger­ ous voltages can continue to exist at the filter terminals for longer than five minutes even after the power has been switched off. The protective earth connections shall be the first to be made when the EMC filter is installed and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective-earth connection must be observed. Impermissible overloading of the EMC filter, such as impermissible voltages at higher frequen­ cies that may cause resonances etc. can lead to destruction of the filter housing. EMC filters must be protected in the application against impermissible exceeding of the rated currents by suitable overcurrent protective. 8 01/06 EMC filters Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as “hazardous”). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, EPCOS-Jones, Baoke, CeraDiode, CSSP, MLSC, PhaseCap, PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. 9 01/06
B84134A0025G001 价格&库存

很抱歉,暂时无法提供与“B84134A0025G001”相匹配的价格&库存,您可以联系我们找货

免费人工找货