4-Line Filters for Converters and Power Electronics
Power line filters for three-phase systems Rated voltage 440/250 V~, 50/60 Hz Rated current 16 to 1600 A Construction
■ Four-line filter ■ Metal case ■ Threaded bushes at end faces for
B84144
RF-tight installation Features
■ ■ ■ ■ ■
Low leakage current Easy to install Degree of protection up to 180 A: IP 201) Space-saving design Design based on EN 133200, UL 1283, CSA 22.2 No.8 1986
Applications
■ ■ ■ ■
General-purpose application in power electronics UPS Wind farms For machine tools, textile and packaging machines
Terminals
■ Safe-to-touch terminal blocks for filters up to 180 A ■ Busbars for filters 250 to 1600 A
Marking Marking on component: Manufacturer’s logo, ordering code, rated voltage, rated current, date code Minimum marking on packaging: Manufacturer’s logo, ordering code
1) In accordance with IEC 60529: 1989; EN 60529: 1991; DIN VDE 0470-1
274 04/02
4-Line Filters for Converters and Power Electronics
Typical circuit diagram
LINE L1 LOAD L1’
B84144
L2
L2’
L3
L3’
N PE
N’ PE
SSB1076-F
Technical data Rated voltage V R Rated current I R Test voltage V P 440/250 V~, 50/60 Hz Referred to 40 °C ambient temperature 1770 V–, 2 s (line/line) 2700 V–, 2 s (lines/case), for 16 … 50 A 2550 V–, 2 s (lines/case), for 80 … 180 A 2121 V–, 2 s (lines/case), for 250 … 1600 A 1,5 · IR for 3 min per hour or 2,5 · IR für 30 s per hour at 400 V~, 50 Hz 25/100/21 (– 25 °C/+100 °C/21 days damp heat test) in accordance with EN 60068-1
Overload capability Leakage current Ileak Climatic category
275 04/02
4-Line Filters for Converters and Power Electronics
Characteristics and ordering codes IR A 16 25 36 50 80 120 150 180 250 500 1000 1600 Terminal cross section mm2 4 10 10 10 25 50 50 95 Busbars I leak mA Rtyp mΩ 10 6 3,5 1,3 0,7 0,5 0,35 0,25 0,095 0,060 0,030 0,020 PV W 8 11 14 10 13 22 24 24 18 45 90 150 Approx. weight kg 2,2 3,7 3,7 4,0 9,5 10 10 13 32 53 140 185
B84144
Ordering code
< 3,5 < 3,5 < 3,5
很抱歉,暂时无法提供与“B84144-A120-R”相匹配的价格&库存,您可以联系我们找货