0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
B84299K0066

B84299K0066

  • 厂商:

    EPCOS

  • 封装:

  • 描述:

    B84299K0066 - EMC filters - EPCOS

  • 数据手册
  • 价格&库存
B84299K0066 数据手册
EMC filters 2-line filters for installations and systems Rated current 2 to 36 A Series/Type: Date: B84299K0061 … K0067 January 2006  EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet and the information contained therein without EPCOS’ prior express consent is prohibited. 2-line filters for installations and systems Power line filters for 1-phase systems with additional LF suppression Rated voltage 250 V DC/AC, 50/60 Hz Rated current 2 to 36 A Construction ■ 2-line filter ■ Metal case ■ Polyurethane potting (UL 94 V-0) B84299K0061 … K0067 Features ■ Especially high differential-mode insertion loss from 20 kHz upwards ■ Safe mounting by press-in nuts ■ Space-saving design ■ ENEC10 and UL approval Applications ■ Switch-mode power supplies for traction, safety systems, automation engineering ■ Power supplies ■ Industrial electronics ■ DC applications Terminals ■ Litz wires Marking Marking on component: Manufacturer’s logo, ordering code, rated voltage, rated current, climatic category, date code Minimum marking on packaging: Manufacturer’s logo, ordering code Typical circuit diagram LINE Blue L LOAD Blue L’ N Black Please read Cautions and warnings and Important notes at the end of this document. N’ Black SSB0591-E-E 2 01/06 2-line filters for installations and systems Technical data and measuring conditions Rated voltage VR Rated current IR Test voltage Vtest Overload capability (thermal) Leakage current lleak Climatic category (IEC 60068-1) 250 V DC/AC, 50/60 Hz B84299K0061 … K0067 Referred to 40 °C ambient temperature 1414 V DC, 2 s (line/line) 2830 V DC, 2 s (lines/case) 1.5 · IR for 3 min per hour or 2.5 · IR for 30 s per hour At 230 V AC, 50 Hz For K0061 and K0062: 25/100/21 (–25 °C/+100 °C/21 days damp heat test) For K0063 ... K0067: 25/085/21 (–25 °C/+85 °C/21 days damp heat test) EN 133200, UL 1283 Approvals Characteristics and ordering codes VR AC/DC V 250 IR A 2 4 6 10 16 25 36 Terminal cross section mm2 AWG 1.0 1. 0 1. 0 1.5 2.5 4.0 6.0 18 18 18 16 14 12 10 lleak mA < 3.5 < 3.5 < 3.5 < 3.5 < 3.5 < 3.5 < 10 Rtyp mΩ 530 150 100 45 35 25 10 Approx. Ordering code weight kg 0.35 0.37 0.82 1.0 1.8 2.9 2.9 B84299K0061C000 B84299K0062C000 B84299K0063 B84299K0064C000 B84299K0065 B84299K0066 B84299K0067 Approvals × × — — — — — — — × × — — — × = approval granted Please read Cautions and warnings and Important notes at the end of this document. 3 01/06 2-line filters for installations and systems Dimensional drawings B84299K0061C000, B84299K0062C000 (2 and 4 A) M4 x 6 B84299K0061 … K0067 30±0.4 3 x litz wires AWG 18 (BU, BK, GNYE) 2 x litz wires AWG 18 (BU, BK) 51 7 300±15 Load Line 350±15 7 45 Type Marking Length 65 mm 75 mm B84299K0061C000 B84299K0062C000 SSB2097-8-E B84299K0063 (6 A) 64±0.4 M4 x 6 46±0.4 3 x litz wires AWG 18 (BU, BK, GNYE) 2 x litz wires AWG 18 (BU, BK) 7 350±15 300±15 7.5 Load Line 7 Marking 50 25.9 84.5 Please read Cautions and warnings and Important notes at the end of this document. Ground terminal M4 x 6 for shielding braid or fixing stud for cable clamp SSB2098-G-E 4 01/06 67 2-line filters for installations and systems B84299K0064C000 (10 A) 80±0.4 M4 x 8 B84299K0061 … K0067 47±0.4 28 2 x litz wires AWG 16 (BU, BK) 7 350±15 8 Load Line Marking ø10 68.5 100.5 1 55 3 x litz wires AWG 16 (BU, BK, GNYE) 300±15 Ground terminal M4 x 8 for shielding braid or fixing stud for cable clamp 7 SSB2099-P-E Please read Cautions and warnings and Important notes at the end of this document. 5 01/06 67 2-line filters for installations and systems B84299K0065 (16 A) 107±0.4 M4 x 6 B84299K0061 … K0067 43±0.4 28 2 x litz wires AWG 14 (BU, BK) 9 3 x litz wires AWG 14 (BU, BK, GNYE) 450±15 Load Marking 100 132 SSB2100-W-E Please read Cautions and warnings and Important notes at the end of this document. 71 7 300±15 Line Ground terminal M4 x 8 for shielding braid or fixing stud for cable clamp 7 6 01/06 68 2-line filters for installations and systems B84299K0066 (25 A) 130±0.4 M5 x 7 B84299K0061 … K0067 73±0.4 28 3 x litz wires AWG 12 (BU, BK, GNYE) 2 x litz wires AWG 12 (BU, BK) 7 8 Ground terminal M4 x 6 for shielding braid or fixing stud for cable clamp 300±15 68.5 Marking 15±3 183 SSB2101-5-E Please read Cautions and warnings and Important notes at the end of this document. 7 01/06 800±20 Load Line 7 85 2-line filters for installations and systems B84299K0067 (36 A) 130±0.4 M5 x 7 B84299K0061 … K0067 73±0.4 28 2 x litz wires AWG 10 (BU, BK) 8 3 x litz wires AWG 10 (BU, BK, GNYE) 240±15 68.5 Marking 15±3 183 SSB2102-D-E Please read Cautions and warnings and Important notes at the end of this document. 8 01/06 800±15 Line Load 7 Ground terminal M4 x 6 for shielding braid or fixing stud for cable clamp 7 85 2-line filters for installations and systems Insertion loss (typical values at Z = 50 Ω) B84299K0061 … K0067 unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) Filters for 2 A 100 B84299K0061C000 SSB0323-3 Filters for 4 A 100 α dB 80 SSB0324-B B84299K0062C000 α dB 80 60 60 40 40 20 20 0 10 4 10 5 10 6 10 7 Hz 10 8 f 0 10 4 10 5 10 6 10 7 Hz 10 8 f Filters for 6 A 100 α dB 80 SSB0325-J Filters for 10 A 100 B84299K0064C000 α dB 80 SSB0326-S 60 60 40 40 20 20 B84299K0063 0 10 4 10 5 10 6 Hz f 10 7 0 10 4 10 5 10 6 Hz f 10 7 Please read Cautions and warnings and Important notes at the end of this document. 9 01/06 2-line filters for installations and systems Insertion loss (typical values at Z = 50 Ω) B84299K0061 … K0067 unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) Filters for 16 A 100 α dB 80 SSB0327-1 Filters for 25 A 100 α dB 80 SSB0328-9 60 60 40 40 20 20 B84299K0065 B84299K0066 7 0 10 4 10 5 10 6 Hz f 10 0 10 4 10 5 10 6 Hz f 10 7 Filters for 36 A 100 α dB 80 SSB0329-H 60 40 20 B84299K0067 0 10 4 10 5 10 6 Hz f 10 7 Please read Cautions and warnings and Important notes at the end of this document. 10 01/06 EMC filters Cautions and warnings Important information Please read all safety and warning notes carefully before installing the EMC filter and putting it into operation (see ). The same applies to the warning signs on the filter. Please ensure that the signs are not removed nor their legibility impaired by external influences. Death, serious bodily injury and substantial material damage to equipment may occur if the appro­ priate safety measures are not carried out or the warnings in the text are not observed. Using according to the terms The EMC filters may be used only for their intended application within the specified values in low­ voltage networks in compliance with the instructions given in the data sheets and the data book. The conditions at the place of application must comply with all specifications for the filter used. Warnings ■ It shall be ensured that only qualified persons (electricity specialists) are engaged on work such ■ ■ ■ ■ as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. Danger of electric shock. EMC filters contain components that store an electric charge. Danger­ ous voltages can continue to exist at the filter terminals for longer than five minutes even after the power has been switched off. The protective earth connections shall be the first to be made when the EMC filter is installed and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective-earth connection must be observed. Impermissible overloading of the EMC filter, such as impermissible voltages at higher frequen­ cies that may cause resonances etc. can lead to destruction of the filter housing. EMC filters must be protected in the application against impermissible exceeding of the rated currents by suitable overcurrent protective. 11 01/06 EMC filters Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as “hazardous”). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, EPCOS-Jones, Baoke, CeraDiode, CSSP, MLSC, PhaseCap, PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. 12 01/06
B84299K0066 价格&库存

很抱歉,暂时无法提供与“B84299K0066”相匹配的价格&库存,您可以联系我们找货

免费人工找货