0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
B84299K63

B84299K63

  • 厂商:

    TDK(东电化)

  • 封装:

    -

  • 描述:

    FILTER POWER LINE 6A 250V

  • 数据手册
  • 价格&库存
B84299K63 数据手册
EMC Filters Series/Type: B84299K0061 The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product B84299K00670000 B84113H*, B84115E*, B84143B*R* B84113H*, 2012-02-10 B84115E*, B84143B*R* B84299K00660000, 2012-01-13 B84142B0016R000 B84299K00660000 B84299K00650000 Date of Withdrawal 2012-02-10 Deadline Last Orders 2012-09-28 Last Shipments 2012-09-28 2012-12-31 2012-06-30 2012-09-30 2012-12-31 © EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. EPCOS AG is a TDK Group Company. Ordering Code Substitute Product B84299K0064C000 B84113H*, B84115E*, B84143B*R* B84113H*, B84115E*, B84143B*R* B84113H*, B84115E*, B84143B*R* B84113H*, B84115E*, B84143B*R* B84299K0063C000 B84299K0062C000 B84299K0061C000 Date of Withdrawal 2012-02-10 Deadline Last Orders 2012-09-28 Last Shipments 2012-02-10 2012-09-28 2012-12-31 2012-02-10 2012-09-28 2012-12-31 2012-02-10 2012-09-28 2012-12-31 2012-12-31 For further information please contact your nearest EPCOS sales office, which will also support you in selecting a suitable substitute. The addresses of our worldwide sales network are presented at www.epcos.com/sales. 2-line filters B84299K0061 … K0067 for installations and systems Technical data and measuring conditions Rated voltage VR 250 V DC/AC, 50/60 Hz Rated current IR Referred to 40 °C ambient temperature Test voltage Vtest 1414 V DC, 2 s (line/line) 2830 V DC, 2 s (lines/case) Overload capability (thermal) 1.5 · IR for 3 min per hour or 2.5 · IR for 30 s per hour Leakage current lleak At 230 V AC, 50 Hz Climatic category (IEC 60068-1) For K0061 and K0062: 25/100/21 (–25 °C/+100 °C/21 days damp heat test) For K0063 ... K0067: 25/085/21 (–25 °C/+85 °C/21 days damp heat test) Approvals EN 133200, UL 1283 Characteristics and ordering codes VR AC/DC V 250 IR Terminal cross section AWG mm2 lleak Rtyp mA 2 1.0 18 < 3.5 4 1.0 18 6 1.0 18 10 1.5 16 Approvals mΩ Approx. Ordering code weight kg 530 0.35 B84299K0061C000 × — < 3.5 150 0.37 B84299K0062C000 × — < 3.5 100 0.82 B84299K0063 — × 16 < 3.5 45 1.0 B84299K0064C000 — × 2.5 14 < 3.5 35 1.8 B84299K0065 — — 25 4.0 12 < 3.5 25 2.9 B84299K0066 — — 36 6.0 10 < 10 10 2.9 B84299K0067 — — A × = approval granted Please read Cautions and warnings and Important notes at the end of this document. 3 01/06 2-line filters B84299K0061 … K0067 for installations and systems Dimensional drawings B84299K0061C000, B84299K0062C000 (2 and 4 A) 45 30±0.4 M4 x 6 350±15 7 Line Load 7 300±15 51 2 x litz wires AWG 18 (BU, BK) 3 x litz wires AWG 18 (BU, BK, GNYE) Marking Type Length B84299K0061C000 B84299K0062C000 65 mm 75 mm SSB2097-8-E B84299K0063 (6 A) M4 x 6 67 46±0.4 64±0.4 7 350±15 Line Load 2 x litz wires AWG 18 (BU, BK) 50 7.5 7 300±15 3 x litz wires AWG 18 (BU, BK, GNYE) Marking 25.9 Ground terminal M4 x 6 for shielding braid or fixing stud for cable clamp 84.5 Please read Cautions and warnings and Important notes at the end of this document. SSB2098-G-E 4 01/06 2-line filters B84299K0061 … K0067 for installations and systems B84299K0064C000 (10 A) 28 47±0.4 8 7 350±15 Ground terminal M4 x 8 for shielding braid or fixing stud for cable clamp Marking ø10 1 55 Load 2 x litz wires AWG 16 (BU, BK) Line 7 300±15 3 x litz wires AWG 16 (BU, BK, GNYE) 67 M4 x 8 80±0.4 68.5 100.5 Please read Cautions and warnings and Important notes at the end of this document. SSB2099-P-E 5 01/06 2-line filters B84299K0061 … K0067 for installations and systems B84299K0065 (16 A) 28 43±0.4 2 x litz wires AWG 14 (BU, BK) Marking 7 300±15 9 Ground terminal M4 x 8 for shielding braid or fixing stud for cable clamp 71 Load Line 450±15 7 3 x litz wires AWG 14 (BU, BK, GNYE) 68 M4 x 6 107±0.4 100 132 Please read Cautions and warnings and Important notes at the end of this document. SSB2100-W-E 6 01/06 2-line filters B84299K0061 … K0067 for installations and systems B84299K0066 (25 A) 28 2 x litz wires AWG 12 (BU, BK) 800±20 Load Line 7 68.5 300±15 7 3 x litz wires AWG 12 (BU, BK, GNYE) 85 M5 x 7 73±0.4 130±0.4 8 Ground terminal M4 x 6 for shielding braid or fixing stud for cable clamp Marking 15±3 183 Please read Cautions and warnings and Important notes at the end of this document. SSB2101-5-E 7 01/06 2-line filters B84299K0061 … K0067 for installations and systems B84299K0067 (36 A) 28 2 x litz wires AWG 10 (BU, BK) 800±15 Load Line 7 68.5 240±15 7 3 x litz wires AWG 10 (BU, BK, GNYE) 85 M5 x 7 73±0.4 130±0.4 8 Ground terminal M4 x 6 for shielding braid or fixing stud for cable clamp Marking 15±3 183 Please read Cautions and warnings and Important notes at the end of this document. SSB2102-D-E 8 01/06 2-line filters B84299K0061 … K0067 for installations and systems Insertion loss (typical values at Z = 50 Ω) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) Filters for 2 A Filters for 4 A SSB0323-3 100 SSB0324-B 100 B84299K0062C000 B84299K0061C000 α dB α dB 80 80 60 60 40 40 20 20 0 10 4 10 5 10 6 10 7 0 10 4 Hz 10 8 f Filters for 6 A 10 5 10 6 10 7 Hz 10 8 f Filters for 10 A SSB0325-J 100 SSB0326-S 100 B84299K0064C000 α dB α dB 80 80 60 60 40 40 20 20 B84299K0063 0 10 4 10 5 10 6 Hz f Please read Cautions and warnings and Important notes at the end of this document. 0 10 4 10 7 9 01/06 10 5 10 6 Hz f 10 7 2-line filters B84299K0061 … K0067 for installations and systems Insertion loss (typical values at Z = 50 Ω) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) Filters for 16 A Filters for 25 A SSB0327-1 100 α SSB0328-9 100 dB α dB 80 80 60 60 40 40 20 20 B84299K0066 B84299K0065 0 10 4 10 5 10 6 Hz f 10 0 10 4 7 Filters for 36 A SSB0329-H 100 α dB 80 60 40 20 B84299K0067 0 10 4 10 5 10 6 Hz f Please read Cautions and warnings and Important notes at the end of this document. 10 7 10 01/06 10 5 10 6 Hz f 10 7 EMC filters Cautions and warnings Important information Please read all safety and warning notes carefully before installing the EMC filter and putting it into ). The same applies to the warning signs on the filter. Please ensure that the signs operation (see are not removed nor their legibility impaired by external influences. Death, serious bodily injury and substantial material damage to equipment may occur if the appro­ priate safety measures are not carried out or the warnings in the text are not observed. Using according to the terms The EMC filters may be used only for their intended application within the specified values in low­ voltage networks in compliance with the instructions given in the data sheets and the data book. The conditions at the place of application must comply with all specifications for the filter used. Warnings ■ It shall be ensured that only qualified persons (electricity specialists) are engaged on work such ■ ■ ■ ■ as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. Danger of electric shock. EMC filters contain components that store an electric charge. Danger­ ous voltages can continue to exist at the filter terminals for longer than five minutes even after the power has been switched off. The protective earth connections shall be the first to be made when the EMC filter is installed and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective-earth connection must be observed. Impermissible overloading of the EMC filter, such as impermissible voltages at higher frequen­ cies that may cause resonances etc. can lead to destruction of the filter housing. EMC filters must be protected in the application against impermissible exceeding of the rated currents by suitable overcurrent protective. 11 01/06 Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule we are either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether a product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.tdk-electronics.tdk.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to our General Terms and Conditions of Supply. 7. Our manufacturing sites serving the automotive business apply the IATF 16949 standard. The IATF certifications confirm our compliance with requirements regarding the quality management system in the automotive industry. Referring to customer requirements and customer specific requirements (“CSR”) TDK always has and will continue to have the policy of respecting individual agreements. Even if IATF 16949 may appear to support the acceptance of unilateral requirements, we hereby like to emphasize that only requirements mutually agreed upon can and will be implemented in our Quality Management System. For clarification purposes we like to point out that obligations from IATF 16949 shall only become legally binding if individually agreed upon. 8. The trade names EPCOS, CeraCharge, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CTVS, DeltaCap, DigiSiMic, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue, MiniCell, MKD, MKK, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PowerHap, PQSine, PQvar, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.tdk-electronics.tdk.com/trademarks. Release 2018-10 12 01/06
B84299K63 价格&库存

很抱歉,暂时无法提供与“B84299K63”相匹配的价格&库存,您可以联系我们找货

免费人工找货