EMC Filters
Series/Type:
B84299K0061
The following products presented in this data sheet are being withdrawn.
Ordering Code
Substitute Product
B84299K00670000
B84113H*,
B84115E*,
B84143B*R*
B84113H*,
2012-02-10
B84115E*,
B84143B*R*
B84299K00660000, 2012-01-13
B84142B0016R000
B84299K00660000
B84299K00650000
Date of
Withdrawal
2012-02-10
Deadline Last
Orders
2012-09-28
Last Shipments
2012-09-28
2012-12-31
2012-06-30
2012-09-30
2012-12-31
© EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
Ordering Code
Substitute Product
B84299K0064C000
B84113H*,
B84115E*,
B84143B*R*
B84113H*,
B84115E*,
B84143B*R*
B84113H*,
B84115E*,
B84143B*R*
B84113H*,
B84115E*,
B84143B*R*
B84299K0063C000
B84299K0062C000
B84299K0061C000
Date of
Withdrawal
2012-02-10
Deadline Last
Orders
2012-09-28
Last Shipments
2012-02-10
2012-09-28
2012-12-31
2012-02-10
2012-09-28
2012-12-31
2012-02-10
2012-09-28
2012-12-31
2012-12-31
For further information please contact your nearest EPCOS sales office, which will also support
you in selecting a suitable substitute. The addresses of our worldwide sales network are
presented at www.epcos.com/sales.
2-line filters
B84299K0061 … K0067
for installations and systems
Technical data and measuring conditions
Rated voltage VR
250 V DC/AC, 50/60 Hz
Rated current IR
Referred to 40 °C ambient temperature
Test voltage Vtest
1414 V DC, 2 s (line/line)
2830 V DC, 2 s (lines/case)
Overload capability (thermal)
1.5 · IR for 3 min per hour or
2.5 · IR for 30 s per hour
Leakage current lleak
At 230 V AC, 50 Hz
Climatic category (IEC 60068-1)
For K0061 and K0062:
25/100/21 (–25 °C/+100 °C/21 days damp heat test)
For K0063 ... K0067:
25/085/21 (–25 °C/+85 °C/21 days damp heat test)
Approvals
EN 133200, UL 1283
Characteristics and ordering codes
VR
AC/DC
V
250
IR
Terminal
cross section
AWG
mm2
lleak
Rtyp
mA
2
1.0
18
< 3.5
4
1.0
18
6
1.0
18
10
1.5
16
Approvals
mΩ
Approx. Ordering code
weight
kg
530
0.35
B84299K0061C000
×
—
< 3.5
150
0.37
B84299K0062C000
×
—
< 3.5
100
0.82
B84299K0063
—
×
16
< 3.5
45
1.0
B84299K0064C000
—
×
2.5
14
< 3.5
35
1.8
B84299K0065
—
—
25
4.0
12
< 3.5
25
2.9
B84299K0066
—
—
36
6.0
10
< 10
10
2.9
B84299K0067
—
—
A
× = approval granted
Please read Cautions and warnings and
Important notes at the end of this document.
3
01/06
2-line filters
B84299K0061 … K0067
for installations and systems
Dimensional drawings
B84299K0061C000, B84299K0062C000 (2 and 4 A)
45
30±0.4
M4 x 6
350±15
7
Line
Load
7
300±15
51
2 x litz wires
AWG 18 (BU, BK)
3 x litz wires AWG 18
(BU, BK, GNYE)
Marking
Type
Length
B84299K0061C000
B84299K0062C000
65 mm
75 mm
SSB2097-8-E
B84299K0063 (6 A)
M4 x 6
67
46±0.4
64±0.4
7
350±15
Line
Load
2 x litz wires
AWG 18 (BU, BK)
50
7.5
7
300±15
3 x litz wires AWG 18
(BU, BK, GNYE)
Marking
25.9
Ground terminal M4 x 6
for shielding braid
or fixing stud
for cable clamp
84.5
Please read Cautions and warnings and
Important notes at the end of this document.
SSB2098-G-E
4
01/06
2-line filters
B84299K0061 … K0067
for installations and systems
B84299K0064C000 (10 A)
28
47±0.4
8
7
350±15
Ground terminal M4 x 8
for shielding braid
or fixing stud
for cable clamp
Marking
ø10
1
55
Load
2 x litz wires
AWG 16 (BU, BK)
Line
7
300±15
3 x litz wires AWG 16
(BU, BK, GNYE)
67
M4 x 8
80±0.4
68.5
100.5
Please read Cautions and warnings and
Important notes at the end of this document.
SSB2099-P-E
5
01/06
2-line filters
B84299K0061 … K0067
for installations and systems
B84299K0065 (16 A)
28
43±0.4
2 x litz wires
AWG 14 (BU, BK)
Marking
7
300±15
9
Ground terminal M4 x 8
for shielding braid
or fixing stud
for cable clamp
71
Load
Line
450±15
7
3 x litz wires AWG 14
(BU, BK, GNYE)
68
M4 x 6
107±0.4
100
132
Please read Cautions and warnings and
Important notes at the end of this document.
SSB2100-W-E
6
01/06
2-line filters
B84299K0061 … K0067
for installations and systems
B84299K0066 (25 A)
28
2 x litz wires
AWG 12 (BU, BK)
800±20
Load
Line
7
68.5
300±15
7
3 x litz wires AWG 12
(BU, BK, GNYE)
85
M5 x 7
73±0.4
130±0.4
8
Ground terminal M4 x 6
for shielding braid
or fixing stud
for cable clamp
Marking
15±3
183
Please read Cautions and warnings and
Important notes at the end of this document.
SSB2101-5-E
7
01/06
2-line filters
B84299K0061 … K0067
for installations and systems
B84299K0067 (36 A)
28
2 x litz wires
AWG 10 (BU, BK)
800±15
Load
Line
7
68.5
240±15
7
3 x litz wires AWG 10
(BU, BK, GNYE)
85
M5 x 7
73±0.4
130±0.4
8
Ground terminal M4 x 6
for shielding braid
or fixing stud
for cable clamp
Marking
15±3
183
Please read Cautions and warnings and
Important notes at the end of this document.
SSB2102-D-E
8
01/06
2-line filters
B84299K0061 … K0067
for installations and systems
Insertion loss (typical values at Z = 50 Ω)
unsymmetrical, adjacent branches terminated
common mode, all branches in parallel (asymmetrical)
differential mode (symmetrical)
Filters for 2 A
Filters for 4 A
SSB0323-3
100
SSB0324-B
100
B84299K0062C000
B84299K0061C000
α
dB
α
dB
80
80
60
60
40
40
20
20
0
10 4
10 5
10 6
10 7
0
10 4
Hz 10 8
f
Filters for 6 A
10 5
10 6
10 7
Hz 10 8
f
Filters for 10 A
SSB0325-J
100
SSB0326-S
100
B84299K0064C000
α
dB
α
dB
80
80
60
60
40
40
20
20
B84299K0063
0
10 4
10 5
10 6
Hz
f
Please read Cautions and warnings and
Important notes at the end of this document.
0
10 4
10 7
9
01/06
10 5
10 6
Hz
f
10 7
2-line filters
B84299K0061 … K0067
for installations and systems
Insertion loss (typical values at Z = 50 Ω)
unsymmetrical, adjacent branches terminated
common mode, all branches in parallel (asymmetrical)
differential mode (symmetrical)
Filters for 16 A
Filters for 25 A
SSB0327-1
100
α
SSB0328-9
100
dB
α
dB
80
80
60
60
40
40
20
20
B84299K0066
B84299K0065
0
10 4
10
5
10
6
Hz
f
10
0
10 4
7
Filters for 36 A
SSB0329-H
100
α
dB
80
60
40
20
B84299K0067
0
10 4
10 5
10 6
Hz
f
Please read Cautions and warnings and
Important notes at the end of this document.
10 7
10
01/06
10
5
10 6
Hz
f
10 7
EMC filters
Cautions and warnings
Important information
Please read all safety and warning notes carefully before installing the EMC filter and putting it into
). The same applies to the warning signs on the filter. Please ensure that the signs
operation (see
are not removed nor their legibility impaired by external influences.
Death, serious bodily injury and substantial material damage to equipment may occur if the appro
priate safety measures are not carried out or the warnings in the text are not observed.
Using according to the terms
The EMC filters may be used only for their intended application within the specified values in low
voltage networks in compliance with the instructions given in the data sheets and the data book.
The conditions at the place of application must comply with all specifications for the filter used.
Warnings
■ It shall be ensured that only qualified persons (electricity specialists) are engaged on work such
■
■
■
■
as planning, assembly, installation, operation, repair and maintenance. They must be provided
with the corresponding documentation.
Danger of electric shock. EMC filters contain components that store an electric charge. Danger
ous voltages can continue to exist at the filter terminals for longer than five minutes even after
the power has been switched off.
The protective earth connections shall be the first to be made when the EMC filter is installed and
the last to be disconnected. Depending on the magnitude of the leakage currents, the particular
specifications for making the protective-earth connection must be observed.
Impermissible overloading of the EMC filter, such as impermissible voltages at higher frequen
cies that may cause resonances etc. can lead to destruction of the filter housing.
EMC filters must be protected in the application against impermissible exceeding of the rated
currents by suitable overcurrent protective.
11
01/06
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for certain
areas of application. These statements are based on our knowledge of typical requirements that are
often placed on our products in the areas of application concerned. We nevertheless expressly point
out that such statements cannot be regarded as binding statements about the suitability of our
products for a particular customer application. As a rule we are either unfamiliar with individual
customer applications or less familiar with them than the customers themselves. For these reasons, it is
always ultimately incumbent on the customer to check and decide whether a product with the properties
described in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or failure
before the end of their usual service life cannot be completely ruled out in the current state of the
art, even if they are operated as specified. In customer applications requiring a very high level of
operational safety and especially in customer applications in which the malfunction or failure of an
electronic component could endanger human life or health (e.g. in accident prevention or life-saving
systems), it must therefore be ensured by means of suitable design of the customer application or other
action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or
damage is sustained by third parties in the event of malfunction or failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this publication
may contain substances subject to restrictions in certain jurisdictions (e.g. because they are
classed as hazardous). Useful information on this will be found in our Material Data Sheets on the
Internet (www.tdk-electronics.tdk.com/material). Should you have any more detailed questions, please
contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications contained
in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available. The
aforementioned does not apply in the case of individual agreements deviating from the foregoing for
customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to our General Terms and
Conditions of Supply.
7. Our manufacturing sites serving the automotive business apply the IATF 16949 standard. The
IATF certifications confirm our compliance with requirements regarding the quality management system
in the automotive industry. Referring to customer requirements and customer specific requirements
(“CSR”) TDK always has and will continue to have the policy of respecting individual agreements. Even
if IATF 16949 may appear to support the acceptance of unilateral requirements, we hereby like to
emphasize that only requirements mutually agreed upon can and will be implemented in our
Quality Management System. For clarification purposes we like to point out that obligations from IATF
16949 shall only become legally binding if individually agreed upon.
8. The trade names EPCOS, CeraCharge, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CTVS,
DeltaCap, DigiSiMic, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue, MiniCell, MKD, MKK, MotorCap,
PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PowerHap, PQSine, PQvar, SIFERRIT, SIFI,
SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, ThermoFuse, WindCap are
trademarks registered or pending in Europe and in other countries. Further information will be found
on the Internet at www.tdk-electronics.tdk.com/trademarks.
Release 2018-10
12
01/06