B84312C114B1

B84312C114B1

  • 厂商:

    TDK(东电化)

  • 封装:

    -

  • 描述:

    FILTER COMM LINE 0.1A 42VAC

  • 数据手册
  • 价格&库存
B84312C114B1 数据手册
Filters for Communication Lines ISDN Systems Series/Type: B84312 Date: January 2004 © EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. EPCOS AG is a TDK Group Company. Filters for communication lines B84312 ISDN systems For ISDN-Interfaces S0, S2, UP0 and U2 plus Siemens Hicom installations Stopband attenuation up to 40 GHz Features Use of coaxial feed-through capacitors on input and output Single or current-balanced chokes depending on requirement Insertion loss to CISPR 17 Installation Single filters are attached straight to the shielding wall. Larger numbers can be housed in filter cabinets or boxes. Various models and the matching flexible connector fittings are available. Overview of ISDN systems and suitable filters System Standard Number Transmission Focal of pairs rate frequency ftest S2 and/or PCM 30 S0 ISDN, 2B+D UP0 ISDN, 2B+D CCITT, G.703 2 2.048 Mbit/s Filter ZL Filter band (Ordering code) width (5 x ftest) Ω 1.024 MHz 5.12 MHz 120 B84312C0112E001 CCITT, I.430 ETS300012 ZVEI 2 144 kbit/s 96 kHz 480 kHz 85... B84312C0110E001 160 1 192 kHz 960 kHz 100 B84312C0114B001 U2B1Q ISDN, 2B+D UK0 ISDN, 2B+D U200 1B+D ANSI 1 304 kbit/s (152 kbit/s in each direction) 160 kbit/s 40 kHz 200 kHz 135 B84312C0060B001 160 kbit/s 60 kHz 300 kHz 150 B84312C0060B001 160 kbit/s (80 kbit/s in each direction) 128 kHz 640 kHz 130 B84312C0114B001 T1.601-1988 FTZ 1 1 TR 220 Interface for Siemens Hicom 1 2 Filters for communication lines B84312 ISDN systems General technical data Rated voltage VR,AC 42 and 100 V Rated voltage VR,DC 80 and 100 V Rated frequency fR See characteristics Rated current IR 100 Line impedance ZL See characteristics Test voltage Vtest 250 VDC, 2 s 250 VDC, 2 s Maximum DC resistance Rmax See characteristics Permissible ambient temperature TA 25/+40 Pass bandwidth at Z L mA Referred to +40 °C ambient temperature Line/line Line/case Per line °C Climatic category (EN 60068-1) 25/085/56 Approx. weight 560 25 °C/+85 °C/56 days damp heat test g Characteristics and ordering codes VR,AC VR,DC fR ZL Rmax V V Ω 100 80 80 80 MHz 0 ... 0.3 0 ... 4 0 ... 4 0 ... 10 Ω 100 42 42 42 150 100 100 50 2 4.2 4.2 1 3 Number of pairs Ordering code 1 1 2 2 B84312C0060B001 B84312C0114B001 B84312C0110E001 B84312C0112E001 Filters for communication lines B84312 ISDN systems Insertion loss αe in passband (typical) B84312C0060B001 Symmetrical measurement circuit with ZL = 150 Ω B84312C0110E001, ...C0114B001 Symmetrical measurement circuit with ZL = 100 Ω 4 Filters for communication lines B84312 ISDN systems B84312C0112E001 Symmetrical measurement circuit with ZL = 50 Ω 5 Filters for communication lines B84312 ISDN systems Insertion loss αe in stopband (typical) Asymmetrical measurement circuit to MIL-STD-220A B84312C0060B001 B84312C0110E001, ...C0114B001 6 Filters for communication lines B84312 ISDN systems B84312C0112E001 Signal characteristic to CCITT G.703 for filter B84312C0112E001 7 Filters for communication lines B84312 ISDN systems Dimensional drawing ➀ Line connection at both ends: 2 x tab connectors for receptacle 2.8 x 0.5 (in accessory bag) ➁ Strain relief with ground connection for cable diameter 4.5 ... 6 mm Hole for installation in shielding wall 8 Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule we are either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether a product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.tdk-electronics.tdk.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to our General Terms and Conditions of Supply. 7. Our manufacturing sites serving the automotive business apply the IATF 16949 standard. The IATF certifications confirm our compliance with requirements regarding the quality management system in the automotive industry. Referring to customer requirements and customer specific requirements (“CSR”) TDK always has and will continue to have the policy of respecting individual agreements. Even if IATF 16949 may appear to support the acceptance of unilateral requirements, we hereby like to emphasize that only requirements mutually agreed upon can and will be implemented in our Quality Management System. For clarification purposes we like to point out that obligations from IATF 16949 shall only become legally binding if individually agreed upon. 8. The trade names EPCOS, CeraCharge, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CTVS, DeltaCap, DigiSiMic, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue, MiniCell, MKD, MKK, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PowerHap, PQSine, PQvar, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.tdk-electronics.tdk.com/trademarks. Release 2018-10
B84312C114B1 价格&库存

很抱歉,暂时无法提供与“B84312C114B1”相匹配的价格&库存,您可以联系我们找货

免费人工找货