Surge Arrester 2-Electrode-Arrester
A80-A75XSMD Ordering code: B88069X6350T602
DC spark-over voltage 1) 2) Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution at 1 kV/µs - for 99 % of measured values - typical values of distribution
75 ± 20 < 350 < 300 < 650 < 600 20 25 20 > 10 < 1.5 ~ 15 ~ 0.6 ~ 60 ~ 1.5 -40 ... +90 40/ 90/ 21 75 YY O
75 YY O - Nominal voltage - Year of production - Non radioactive
V % V V V V kA kA A GΩ pF V A V g °C
Nominal impulse discharge current (wave 8/20 µs) Single impulse discharge current (wave 8/20 µs) Nominal alternating discharge current (50 Hz, 1 s) Insulation resistance at 25 Vdc Capacitance at 1 MHz Arc voltage at 1 A Glow to arc transition current Glow voltage Weight Operation and storage temperature Climatic category (IEC 60068-1) Marking, blue
1) 2)
At delivery AQL 0.65 level II, DIN ISO 2859 In ionized mode Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
KB AB E / KB AB PM Page 1 of 2
Issue 02, 10.06.2004
Surge Arrester 2-Electrode-Arrester
A80-A75XSMD Ordering code: B88069X6350T602
Not to scale Dimensions in mm Non controlled document
Tape and reel packing comply with the specification of IEC 60286-3
EPCOS AG 2002. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Association), unless otherwise agreed. KB AB E / KB AB PM Page 2 of 2 Issue 02, 10.06.2004