0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PKA2231CI

PKA2231CI

  • 厂商:

    ERICSSON

  • 封装:

  • 描述:

    PKA2231CI - 25-40 W DC/DC Power Modules 24 V Input Series - Ericsson

  • 数据手册
  • 价格&库存
PKA2231CI 数据手册
PKA 2000 I 25–40 W DC/DC Power Modules 24 V Input Series • Single, dual and triple output • 500 V dc isolation voltage • MTBF >2 million hours @75 °C case temperature • Complete, no extra filters or heatsinks required The 25-40 watts PKA 2000 series hybrid DC/DC power modules are especially designed for decentralized 24/28 Vdc system distributed onboard DC/DC coverters. By using a thickfilm thecknology, which provides a high degree of intergration as well as efficient thermal management, and by utilizing a 300 kHz switching frequency, these highly reliable products comply to demanding applications within e.g. cellular radio, medical, industrial and airborne industri. Input to output isolation is 500 Vdc . Mechanical ruggedness – in conformance with IEC 68-2 - is close to requirements for discrete components. Extreme temperature conditions can be met since the converters can operate with full output power in ambient temperatures ranging from –45 to +85 °C or up to +115 °C case temperature, making the products ideal also for applications within various non-controlled environments. The PKA series is manufactured using highly automated manufacturing lines with a world-class quality commitment and a five-year warranty. Ericsson Microelectronics AB has been an ISO 9001 certified supplier since 1991. For a complete product program please reference the back cover. E General Absolute Maximum Ratings Characteristics TC TS VI VISO Case temperature1) min – 45 – 55 – 0.5 500 1.3 0 0 5 VO max +115 +125 36 Unit °C °C V dc V dc Ws V V Storage temperature Input voltage Isolation voltage (input to output test voltage) Transient input energy @ TA = +25 °C Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute MaximumRatings, sometimes referred to as no destruction limits, are normally tested with one parameter at a time exceeding the limits of Output data or Electrical Characteristics. If exposed to stress above these limits, function and performance may degrade in an unspecified manner. VRC Vadj 1) Remote control voltage (pin 9) Output adjust voltage (pin 10) Safety The PKA 2000 I Series DC/DC power modules are designed in accordance with EN 60 950, Safety of information technology equipment including electrical business equipment and certified by SEMKO. The PKA power modules are recognized by UL and meet the applicable requirements in UL 1950 Safety of information technology equipment, the applicable Canadian safety requirements and UL 1012 Standard for power supplies. The DC/DC power module shall be installed in an end-use equipment and considerations should be given to measuring the case temperature to comply with TC max when in operation. They are intended to be supplied by isolated secondary circuitry and shall be installed in compliance with the requirements of the ultimate application. If connected to a 24 V DC power system reinforced insulation must be provided in the power supply that isolates the input from the ac mains. The isolation in the DC/DC power module is an operational insulation in accordance with EN 60 950. One pole of the input and one pole of the output is to be grounded or both are to be kept floating. The terminal pins are only intended for connection to mating connectors of internal wiring inside the end-use equipment. The isolation voltage is a galvanic isolation and is verified in an electric strength test. Test voltage (VISO) between input and output is 500 V dc. The capacitor between input and output has a value of 10 nF and the leakage current is less than 1mA @ 26 V dc. Flammability ratings of the terminal support and internal plastic construction details meets UL 94V-0. Corresponding ambient temp. range (TA) at full output power is –45 to +85 °C. Input TC < TC max Characteristics Conditions TC < TC max VI Input voltage range TC < + 95 °C VIoff II rush II 2t PIi Input idling power Input transient peak current (transient immunity) 2) PKA 2411 PIL = 30 A, 2×10-3 A2s *) PKA 2432 PIL = 30 A, 5×10-3 A2s min 19 19 13 typ max 32 35 18 Unit V V V A A2 s W Turn-off input voltage Inrush current2) (See Operating Information) 15 IO = IOnom 5×10-4 IO = 0,TC = 0...+95°C P< 1 kW, VC < 50 V, tr/td = 10/1000 ms 0.8 20 A Environmental Characteristics Characteristics Test procedure & conditions Frequency Amplitude Acceleration Number of cycles Peak acceleration Shock duration Peak acceleration Bump duration Number of bumps Temperature Number of cycles Temperature Duration Temperature Humidity Duration 10–500 Hz 0.75 mm 10 g 10 in each axis 200 g 3 ms 40 g 6 ms 1000 in 6 directions –40°C to +125°C 10 40°C 56 days 85°C 85% RH 500 hours Vibration (Sinusoidal) IEC 68-2-6 Fc Shock (Half sinus) Bump (Half sinus) IEC 68-2-27 Ea IEC 68-2-29 Eb Temperature change Damp heat IEC 68-2-14 Na IEC 68-2-3 Ca Accelerated damp heat IEC 68-2-3 Ca with bias 2 EN/LZT 146 09 R1A © Ericsson Microelectronics AB, June 2000 Mechanical Data On-Card Off-Card Dimensions in mm (in) Connections Pin 1 2 3 4 5 6 Designation RC NC –In +In Aux NC –Out 2 –Out 3 NC +Out 2 –Out 1/Rtn +Out 1 Vadj Function Remote control. To turn-on and turn-off the output. It is also used to adjust the turn-off input voltage threshold. Not connected. Negative input. Positive input. Auxiliary. Not connected in singles. Negative output 2 in duals. Negative output 3 in triples. Not connected in singles. Positive output 2 in duals and triples. Negative output 1 in singles and duals. Output return in triples. Positive output 1in all models. Output voltage adjust. Weight 95 gr (3.35 oz) PKA 2432 PIL 112 gr (3.95 oz) Case Blue anodized self-cooled aluminium chassis with snap-on cover and with tin plated brass pins. Thermal data Thermal resistance case to ambient PI-version Rth case-amb. = 5.0 °C/W PIL-version Rth case-amb. = 4.6 °C/W For Off-Card versions (CI) the specification is valid if mounting surface has Rth < 7 °C/W to ambient. 3 7 8 9 10 EN/LZT 146 09 R1A © Ericsson Microelectronics AB, June 2000 Electrical Data Fundamental circuit diagrams Single output 5 4 1 9 8 10 3 Dual output 5 4 1 9 8 10 3 Triple output 5 4 7 6 9 8 1 10 3 4 EN/LZT 146 09 R1A © Ericsson Microelectronics AB, June 2000 PKA 2211 PI, CI TC = 0…+95°C, VI = 19...35V unless otherwise specified. Output Output 1 Characteristics Conditions min VOi Output voltage initial setting and accuracy Output adjust range1) Output voltage tolerance band Idling voltage Line regulation Load regulation ttr Load transient recovery time Long term drift included IO = 25 mA IO = IO max IO = 0.1 …1.0 ´ IO max, VI = 26 V IO= 0.1 …1.0 ´ IO max, VI = 26 V load step = 0.8 × IOmax di
PKA2231CI 价格&库存

很抱歉,暂时无法提供与“PKA2231CI”相匹配的价格&库存,您可以联系我们找货

免费人工找货