PRODUCT DATA SHEET
LINE MATCHING TRANSFORMER
P3034
Features
∗ ∗ ∗ ∗ ∗ ∗ ∗ Low Distortion Lead-free (Pb-free) RoHS compliant 12.6mm (0.5") seated height Vacuum encapsulated IEC 60950 and UL 60950 Certified UL Recognized Component
Applications
∗ ∗ ∗ ∗ Telecommunications V.34plus modems Portable computers Fax / modems
DESCRIPTION
P3034 is intended for V.34plus applications where low distortion at moderate power levels is required at a competitive price. P3034 is a drop-in replacement for industry standard P1200 for circuits to be upgraded to V.34plus (33,600 bits/second). P3034 is also mechanically and electrically compatible with P2001. P3034 meets international safety standards, being vacuum encapsulated and 100% tested to withstand 6.5kV DC. The part is completely lead-free, compliant with RoHS Directve 2002/95/EC, and suitable for lead-free and conventional processing. P3034 is certified to IEC 60950 and UL 60950. P3034 is a UL Recognized Component and is supported an IEC CB Test Certificate.
ETALDOC 458/10
Page 1 of 4
April 2005
P3034
SPECIFICATIONS
Electrical At T = 25ºC and as circuit fig. 2 unless otherwise stated. Parameter Insertion Loss Frequency response Conditions f = 2kHz, RL = 560Ω LF-3dB cutoff HF-3dB cutoff 200Hz - 4kHz 200Hz - 4kHz 450Hz 0dBm in line 300Hz -10dBm 600Hz -10dBm DC – 5kHz Method TG25 Excitation 50Hz 250V rms. Output voltage across line 50Hz DC Ambient temperature 0 -40 +70 +125 ºC ºC Min 10 18 80 Typ -78 –92 -105 Max 1.5 50 ±0.2 Units dB Hz kHz dB dB dBm dBm dBm dB
Return Loss Third Harmonic Distortion (1) Balance Saturation
3.88 5.5
-
10 65 -
Vrms Vpeak kVrms kV
Voltage isolation (2) Operating range: Functional Storage
Lumped equivalent circuit parameters as Fig. 1 DC resistance, RDC (3) Leakage inductance ΔL Shunt inductance Lp Shunt loss Rp (4) Notes 1. Third harmonic typically exceeds other harmonics by 20dB. 2. Components are 100% tested at 6.5kV DC. 3. Caution: do not pass DC through windings. Telephone line current, etc. must be diverted using choke or semiconductor line hold circuit. 4. At signal levels greater than 100mV, Lp will increase and Rp will decrease slightly but the effect is usually favourable to the return loss characteristic.
(4)
Sum of windings
120 14.5
6 18
148 19 -
Ω mH H kΩ
10mV 200Hz 10mV 200Hz
4.5 12
Equivalent Circuit
Fig. 1
½ L ½R
½R
½L
IDEAL 1:1
LINE
EQUIPMENT
ETALDOC 458/10
Page 2 of 4
April 2005
P3034
MATCHING RECOMMENDATIONS
600Ω MATCH
Recommended Circ uit
F2 ig.
600 + 50% 6.8μF _ 20% * 270 LINE 27nF + 5% _ 33nF + 5% _ 560 + 2% _ LINE * If return loss > 16dB, 300Hz - 4kHz is ac ceptable, bloc king capacitor may be relaxed to 4.7μF + 50% _
20%
EUROPEAN CTR21 COMPLEX MATCH
Recommended Circ uit
F3 ig.
(150nF) 100nF
150nF
2.2μF
750 56nF
750 (680)
150 (220)
Figure 3 gives flat RX and TX responses against the CTR21 complex reference impedance (typically around ±0.5dB 300Hz - 3.4kHz). Return loss is typically better than 20dB. The circuit values in parentheses give optimum flatness at a small sacrifice in return loss. For circuits with existing board drillings, figure 4 gives good return loss (>20dB) and RX flatness against the CTR21 complex reference impedance, but TX flatness is degraded by the use of this topology.
F4 ig.
150nF 270
2.2μF
750 LINE
68nF 330 27nF 820
CONSTRUCTION
e2
Dimensions shown are in millimetres (inches). Geometric centres of outline and pin grid coincide within a tolerance circle of 0.6mm Windings may be used interchangeably as primary or secondary.
ETALDOC 458/10
Page 3 of 4
April 2005
P3034
SAFETY
Constructed in accordance with IEC 60950-1, EN 60950-1, supplementary insulation, and UL 60950-1, reinforced insulation, 250Vrms maximum working voltage, flammability class V-0. Distances through solid insulation 0.4mm minimum.
CERTIFICATION
Certified under the IEC CB scheme (Certificate DK-8570) to IEC 60950-1-2001, sub-clauses 1.5, 1.5.1, 1.5.2, 1.7.1, 2.9, 2.9.1, 2.9.2, 2.9.3, 2.10, 2.10.1, 2.10.2, 2.10.3, 2.10.3.1, 2.10.3.3, 2.10.4, 2.10.5, 2.10.5.1, 2.10.5.2, 2.10.5.4, 4.7, 4.7.1 (classV-1), 4.7.3, 4.7.3.1, 4.7.3.4, 5.2, 5.2.1, 5.2.2, 6.1.2.1 (Finland, Norway, Sweden national deviations) for a maximum working voltage of 250Vrms, nominal mains supply voltage not exceeding 300Vrms and a maximum operating temperature of 70ºC in Pollution Degree 2 environments, supplementary insulation. Recognized under the Component Recognition Program of Underwriters Laboratories Inc. to US and Canadian requirements CAN/CSA C22.2 No. 60950-1-03/UL60950-1, First Edition, based on IEC 60950-1, First Edition, maximum working voltage 250Vrms, Pollution Degree 2, reinforced insulation. UL File number E203175. Additionally, Profec Technologies certifies all transformers as providing voltage isolation of 3.88kVrms, 5.5kV DC minimum. All shipments are supported by a certificate of conformity to current applicable safety standards
ABSOLUTE MAXIMUM RATINGS
(Ratings of components independent of circuit). Short term isolation voltage (1s) 4.6kVrms, 6.5kV DC 100μA -40ºC to +125ºC 260ºC
COPYRIGHT
ETAL, P1200, P2001 and P3034 are Trade Marks of Profec Technologies Ltd. The Trade Mark ETAL is registered at the UK Trade Marks Registry. Profec Technologies Ltd. is the owner of the design right under the Copyright Designs and Patents Act 1988 and no rights or licences are hereby granted or implied to any third party. © 1996 - 2005 Profec Technologies Ltd. Reproduction prohibited.
DC current Storage temperature
Lead temperature, 10s
E203175
ISO 9001 FM 25326
ETAL Group Oy, Kuormatie 14, FIN-03101, Nummela Telephone: +358 (0)20 7500 330 Fax: +358 (0)20 7500 333 Website: www.etalgroup.com Email: etalgroup@egruppen.com ETALDOC 458/10 Page 4 of 4 April 2005