PRODUCT DATA SHEET
ULTRA LOW DISTORTION LINE MATCHING TRANSFORMER
Features
∗ ∗ ∗ ∗ ∗ ∗ ∗ ∗ ∗ Lead-free (Pb-free) RoHS compliant Low Distortion 12.6mm (0.5") seated height Extended Frequency Response IEC 60950 and UL 60950 certified UL Recognized Component Flat TX and RX Responses High Thermal Stability
P3176
Applications
∗ V.90 and V.92 modems
DESCRIPTION
P3176 is intended for V.90 and V.92 (56kbps) modems and other high-speed applications where low distortion at high power levels and very low voiceband frequencies is required at a competitive price. P3176 is mechanically compatible with industry standard P1200 and P2001 and electrically and mechanically compatible with P3146. P3176 has extended flat frequency response from 30Hz to 4kHz with very low levels of signal distortion at signal frequencies as low as 150Hz. P3176 also exhibits stable characteristics over its operating temperature range to maximize data throughput under varying environmental conditions without the need for modem retraining. P3176 meets international safety standards, being vacuum encapsulated and 100% tested to withstand 6.5kV. The part is completely lead-free, compliant with RoHS Directive 2002/95/EC, and suitable for lead-free and conventional processing. P3176 is certified to IEC 60950 and UL 60950. P3176 is a UL Recognized Component and is supported an IEC CB Test Certificate.
ETALDOC 575/9
Page 1 of 4
February 2006
P3176
SPECIFICATIONS
Electrical At T = 25ºC and as circuit Fig. 2 unless otherwise stated. Parameter Insertion Loss Frequency Response Conditions f = 2kHz, RL = 510Ω LF -3dB cutoff HF -3dB cutoff 100Hz - 4kHz 200Hz - 4kHz 450Hz 0dBm in line 150Hz -3dBm in line Excitation 50Hz 250Vrms. Output voltage across line 50Hz DC Ambient temperature -25 -40 +85 +125 ºC ºC Min 16 Typ 2.5 10 6 ±0.6 -85 -78 Max 10 65 Units dB Hz kHz dB dB dBm dBm Vrms Vpeak
Return Loss Third Harmonic Distortion (1) Saturation
Voltage isolation(2) Operating range: Functional Storage
3.88 5.5
-
-
kVrms kV
Lumped equivalent circuit parameters as Fig. 1 DC resistance, RDC(3) Leakage inductance ΔL Shunt inductance Lp Shunt loss Rp
(4) (4)
Sum of windings
180 22.3
11 25
220 27.7 -
Ω mH H kΩ
10mV 200Hz 10mV 200Hz
8.5 17
Notes 1. Third harmonic typically exceeds other harmonics by 10dB. 2. Components are 100% tested at 6.5kV DC. 3. Caution: do not pass DC through windings. Telephone line current, etc. must be diverted using semiconductor line hold circuit. 4. At signal levels greater than 100mV, Lp will increase and Rp will decrease slightly but the effect is usually favourable to the return loss characteristic.
Equivalent Circuit
F1 ig
IDE AL 1:1
LINE
E IP NT QU ME
ETALDOC 575/9
Page 2 of 4
February 2006
P3176
MATCHING RECOMMENDATIONS
600Ω MATCH
R ecommended Circuit
F2 ig
600 22μF 33nF LINE 330 39nF T X
EUROPEAN CTR21 COMPLEX MATCH
R ecommended Circuit
F3 ig
150nF 270 510 750 LINE 100 22μF 68nF 910 100nF 120 T X
CONSTRUCTION
e2
Dimensions shown are in millimetres (inches). Geometric centres of outline and pin grid coincide within a tolerance circle of 0.6mmØ. Windings may be used interchangeably as primary or secondary.
ETALDOC 575/9
Page 3 of 4
February 2006
P3176
SAFETY
Constructed in accordance with IEC 60950-1:2001, EN 60950-1:2001 and UL 60950-1 First Edition, supplementary insulation, 250Vrms maximum working voltage, flammability class V-0. Distances through solid insulation 0.4mm minimum.
CERTIFICATION
Certified under the IEC CB scheme (Certificate DK-9431) to IEC 60950-1:2001, sub-clauses 1.5, 1.5.1, 1.5.2, 1.7, 1.7.1, 2, 2.9, 2.9.1, 2.9.2, 2.9.3, 2.10, 2.10.1, 2.10.2, 2.10.3, 2.10.3.1, 2.10.3.3, 2.10.4, 2.10.5, 2.10.5.1, 2.10.5.4, 4, 4.7, 4.7.1, 4.7.3, 4.7.3.1, 4.7.3.4, 5, 5.2, 5.2.1, and 5.2.2 for a maximum working voltage of 250Vrms, nominal mains supply voltage not exceeding 300Vrms and a maximum operating temperature of 85ºC in Pollution Degree 2 environments, supplementary insulation, including national differences for Denmark, Finland, Germany, Norway, Sweden, Switzerland, USA, Canada and UK. Recognized under the Component Recognition Program of Underwriters Laboratories Inc. to US and Canadian requirements CAN/CSA C22.2 No. 60950-1-03/UL60950-1, First Edition, based on IEC 60950-1, First Edition, maximum working voltage 250Vrms, Pollution Degree 2, reinforced insulation. UL File number E203175. Additionally, Profec Technologies certifies all transformers as providing voltage isolation of 3.88kVrms, 5.5kV DC minimum. All shipments are supported by a certificate of conformity to current applicable safety standards.
ABSOLUTE MAXIMUM RATINGS
(Ratings of components independent of circuit). Short term isolation voltage (1s) DC current Storage temperature Lead temperature, 10s 4.6kVrms, 6.5kVDC 100μA -40ºC to +125ºC 260ºC
COPYRIGHT
ETAL, P3176, P3146, P1200 and P2001 are Trade Marks of Profec Technologies Ltd. The Trade Mark ETAL is registered at the UK Trade Marks Registry. Profec Technologies Ltd. is the owner of the design right under the Copyright Designs and Patents Act 1988 and no rights or licences are hereby granted or implied to any third party. © 1998 - 2006 Profec Technologies Ltd. Reproduction prohibited.
E203175
ETAL Group Oy, Kuormatie 14, FIN-03101, Nummela Telephone: +358 (0)20 7500 330 Fax: +358 (0)20 7500 333 Website: www.etalgroup.com Email: etalgroup@egruppen.com
ISO 9001 FM 25326
ETALDOC 575/9
Page 4 of 4