PRODUCT DATA SHEET
ADSL Transformer
Features
∗ ∗ ∗ ∗ ∗ ∗ Lead-free (Pb-free) Low Distortion IEC 950 and UL 60950 Certified UL Recognized Component Supplementary Insulation Industry Standard Footprint
P3937
Applications
∗ Alcatel DynaMiTe CO ∗ ADSL over POTS
DESCRIPTION
P3937 is a low distortion transformer for Central Office ADSL over POTS applications using the Alcatel MTK 20450 chipset. P3937 is certified to safety standards IEC 950 and UL 60950 for supplementary insulation, 250V working voltage. P3937 is a UL Recognized Component and is supported by an IEC CB Test Certificate. The part is completely lead-free and suitable for lead-free and conventional processing. The safety system yields very low transformer parasitics, ensuring that P3937 exhibits excellent frequency response and balance; in combination with its good harmonic distortion performance, P3937 is ideally suited to low cost yet demanding ADSL applications.
ETALDOC 63/4
Page 1 of 4
January 2004
P3937
SPECIFICATIONS
Electrical Typical values at T = 25ºC, unless otherwise stated. Parameter Inductance Leakage inductance Interwinding capacitance DC resistance Turns ratio Voltage isolation
(1)
Conditions 10kHz 100mV 1-5 (link 2-4) 100kHz, 100mV, 1-5 (link 2-4; link 6, 7, 9, 10) 100kHz 100mV 5-6 (link 1, 2, 4, 5; link 6, 7, 9, 10) 1-4; 2-5 6-9; 7-10 5-1 : 6-10 (link 2-4; link 7-9) 50Hz DC (1, 2, 4, 5 : 6, 7, 9, 10) Ambient temperature
Min 390 -
Typ -
Max 430 10 30
Units µH µH pF
1.98 2.12 3.0
0.34 0.22 2.00 -
2.02 -
Ω Ω kVrms kV
Operating range: Functional Storage Notes
-40 -40
-
+85 +85
ºC ºC
1. Components are 100% tested at 3.25kV DC.
ETALDOC 63/4
Page 2 of 4
January 2004
P3937
CONSTRUCTION
Dimensions
Fig. 1
13,60 max (0.54)
Connections
Fig. 2
13,30 m ax (0.52)
5,08 (0.20) ø1,00 (0.04) 10,16 (0.40)
12,80 max (0.50)
2:1
Ø0,60 (0.02) 3,80 (0.15) 10,16 (0.40) 5,08 (0.20) 10,16 (0.40)
T erminals finished: S nAg
Dimensions shown are in millimetres (inches). Terminal references in parentheses denote alternative customer designation.
SAFETY
Constructed in accordance with IEC 60950-1, EN 60950-1 and UL 60950-1, supplementary insulation, 250V maximum working voltage, flammability class V-0. Installation requirements should be observed whereby a minimum of 1.0mm creepage and 1.5mm clearance is maintained between the ferrite core and accessible conductive parts in the host equipment.
ABSOLUTE MAXIMUM RATINGS
(Ratings of components independent of circuit). Short term isolation voltage (1s) Storage temperature Terminal temperature (10s) 2.12kVrms, 3.0kVDC -40ºC to +85ºC 260ºC
ETALDOC 63/4
Page 3 of 4
January 2004
10,16 (0.40)
P3937
CERTIFICATION
Certified by BSI to IEC 950:1991/A4:1996 (IEC CB Test Certificate No. GB518W) sub-clauses 1.5, 1.5.1, 1.5.3, 2.2, 2.2.2, 2.2.3, 2.2.4, 2.9.2, 2.9.3, 2.9.4, 4.4, 4.4.3.2 (class V-0) and 5.3 for a maximum working voltage of 250Vrms, nominal mains supply voltage not exceeding 300Vrms and a maximum operating temperature of +85ºC in Pollution Degree 2 environments, supplementary insulation, clearance greater than 2.0mm, creepage greater than 2.5mm, distance through solid insulation greater than 0.4mm. Recognized under the Component Recognition Program of Underwriters Laboratories Inc. to US and Canadian requirements CAN/CSA C22.2 No. 60950-1-03/UL60950-1, First Edition, based on IEC 60950-1, First Edition, maximum working voltage 250Vrms, Pollution Degree 2, supplementary insulation. UL File number E203175 Additionally, Profec Technologies certifies all transformers as providing voltage isolation of 2.12kVrms, 3kV DC minimum. All shipments are supported by a Certificate of Conformity to current applicable safety standards.
COPYRIGHT
ETAL and P3937 are Trade Marks of Profec Technologies Ltd. The Trade Mark ETAL is registered at the UK Trade Marks Registry. Profec Technologies Ltd. is the owner of the design right under the Copyright Designs and Patents Act 1988 and no rights or licences are hereby granted or implied to any third party. © 2001, 2004 Profec Technologies Ltd. Reproduction prohibited.
E203175
ISO 9001 FM 25326
ETAL Group Oy, Kuormatie 14, FIN-03101, Nummela Telephone: +358 (0)20 7500 330 Fax: +358 (0)20 7500 333 Website: www.etalgroup.com Email: etalgroup@egruppen.com ETALDOC 63/4 Page 4 of 4 January 2004