Self-powered Time Counter
H7ET
Counters
• Seven digits, time range 0 to 3999d23.9h. • Dual time range: 999999.9 ←→ 3999d23.9h or 999h59m59s ←→ 9999h59.9m
Model Number Structure
I Model Number Legend
H7ET - N
1 2
3 4
1. Count Input None: No-voltage input V: PNP/NPN universal DC voltage input FV: AC/DC multi-voltage input 2. Time Range None: 999999.9h/3999d23.9h 1: 999h59m59s/9999h59.9m
3. Case Color None: Light gray B: Black 4. Display None: 7-segment LCD without backlight H: 7-segment LCD with backlight
Ordering Information
I Time Counters
Timer input Display 999999.9h ←→ 3999d23.9h (switchable) Light-gray body PNP/NPN universal DC volt- 7-segment LCD with backage input light 7-segment LCD AC/DC multi-voltage input No-voltage input 7-segment LCD 7-segment LCD H7ET-NV-H H7ET-NV H7ET-NFV H7ET-N Black body H7ET-NV-BH H7ET-NV-B H7ET-NFV-B H7ET-N-B Time range 999h59min59s ←→ 9999h59.9min (switchable) Light-gray body H7ET-NV1-H H7ET-NV1 H7ET-NFV1 H7ET-N1 Black body H7ET-NV1-BH H7ET-NV1-B H7ET-NFV1-B H7ET-N1-B
I Accessories (Order Separately)
Lithium Battery Wire-wrap Terminal (set of two terminals) Flush Mounting Adapter Y92S-36 Y92S-37 26 mm × 45.3 mm 27.5 mm × 52.5 mm 24.8 mm × 48.8 mm Note: The New H7E models are supplied with a Y92F-34 Mounting Bracket. Y92F-75 Y92F-76 Y92F-77B Compact Flush Mounting Bracket (See note.) Y92F-35
Self-powered Time Counter
H7ET
C-17
Specifications
I General
Item Operating mode Mounting method External connections Reset Display Number of digits Time range Timer input H7ET-NV-@ H7ET-NV-@H Accumulating Flush mounting Screw terminals External/Manual reset 7-segment LCD with or without backlight, zero suppression (character height: 8.6 mm) (see note 1) 7 0.0h to 999999.9h ←→ 0.0h to 3999d23.9h (switchable with switch) PNP/NPN univer- AC/DC multi-voltsal DC voltage in- age input put Light gray or black (-B models) Waterproof packing, flush mounting bracket, time unit labels (see note 2) UL863, CSA C22.2 No.14, Lloyds Conforms to EN61010-1/IEC61010-1 (pollution degree2/overvoltage category III) Conforms to VDE0106/P100 No-voltage input 0s to 999h59min59s ←→ 0.0min to 9999h59.9min (switchable with switch) PNP/NPN univer- AC/DC multi-voltsal DC voltage in- age input put No-voltage input H7ET-NFV-@ H7ET-N-@ H7ET-NV1-@ H7ET-NV1-@H H7ET-NFV1-@ H7ET-N1-@
Case color Attachment Approved standard
Note: 1. Only PNP/NPN universal DC voltage input models (-H models) have a backlight. 2. “-hours”, “-d-h”, “-h-m”, and “-h-m-s” labels are included.
I Ratings
Item Supply voltage H7ET-NV@-@ H7ET-NV@-@H H7ET-NFV@-@ H7ET-N@-@ Backlight model: 24 VDC (0.3 W max.) Not required (powered by built-in battery) (for backlight) No-backlight model: Not required (powered by built-in battery) High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input impedance: Approx. 4.7 kΩ) High (logic) level: 24 to 240 VAC/VDC, 50/60 Hz Low (logic) level: 0 to 2.4 VAC/VDC, 50/ 60 Hz No voltage input Maximum short-circuit impedance: 10 kΩ max. Short-circuit residual voltage: 0.5 V max. Minimum open impedance: 750 kΩ min. 1s External reset and manual reset: Minimum signal width of 20 ms 0.98 N·m max. No voltage input Maximum short-circuit impedance: 10 kΩ max. Short-circuit residual voltage: 0.5 V max. Minimum open impedance: 750 kΩ min.
Timer input
Reset input
Minimum pulse width Reset system Terminal screw tightening torque
Ambient tempera- Operating: -10°C to 55°C (with no condensation or icing) Storage: -25°C to 65°C (with no condensation or icing) ture Ambient humidity Operating: 25% to 85%
C-18
Self-powered Time Counter H7ET
I Characteristics
Item Time accuracy Insulation resistance H7ET-NV@-@ H7ET-NV@-H@ ±100 ppm (25°C) 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts, and between the backlight power supply and timer input terminals/reset terminals for backlight models 1,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying metal parts and between the backlight power supply and timer input terminals/reset terminals for backlight models 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts and between timer input terminals and reset terminals 3,700 VAC, 50/60 Hz for 1 min between timer input terminals and exposed non-current-carrying metal parts 2,200 VAC, 50/60 Hz for 1 min between reset terminals and exposed non-current-carrying metal parts and between timer input terminals and reset terminals 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts Counters H7ET-NFV@-@ H7ET-N@-@
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying metal parts
Impulse withstand voltage
4.5 kV between current-carrying termi- 4.5 kV between current-carrying termi- 4.5 kV between current-carrying terminal and exposed non-current-carrying nal and exposed non-current-carrying nal and exposed non-current-carrying metal parts metal parts metal parts 3 kV between timer input terminals and reset terminals Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) ±600 V (Between timer input terminals/ ±1.5 kV (Between timer input termiBetween reset terminals) nals) ±480 V (Between the backlight power ±500 V (Between reset terminals) supply terminals for backlight models) ±500 V (Between timer input terminals/ Between reset terminals)
Noise immunity
Static immunity Vibration resistance Shock resistance EMC
±8 kV (malfunction) Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions Malfunction: 200 m/s2 3 times each in 6 directions Destruction: 300 m/s2 3 times each in 6 directions (EMI) Emission Enclosure: (EMS) Immunity ESD: EN61326 EN55011 Group 1 class B EN61326 EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves: EN61000-4-3: 10 V/m (900 MHz ± 5 MHz) (level 3) Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power line (level 3) 2 kV I/O signal line (level 4) Front panel: IP66, NEMA4 with waterproof packing Terminal block: IP20 No-backlight model: Approx. 60 g Backlight model: Approx. 65 g Approx. 60 g Approx. 60 g
Degree of protection Weight (see note)
Note: Weight includes waterproof packing and flush mounting bracket.
I Reference Value
Item Battery life Value 10 years min. with continuous input at 25°C (lithium battery) Note The battery life is calculated according to the conditions in the left column and therefore is not a guaranteed value. Use these value as reference for maintenance or replacement.
Self-powered Time Counter
H7ET
C-19
Connections
I Terminal Arrangement
Bottom view: View of the Time Counter rotated horizontally 180°
Backlight Model
No-backlight Model
Backlight 24 VDC Timer input Reset input
Timer input
Reset input
I Connections
H7ET Time Counter
PNP/NPN Universal DC Voltage Input Model With Backlight
1. Contact Input (Input by a Relay or Switch Contact)
Relay Backlight 24 VDC Input Input Reset Relay
2. Solid-state Input
Open collector of a PNP transistor Open collector of a Backlight PNP transistor 24 VDC Reset
or Switch
or Switch
or Open collector of an NPN transistor
or Open collector of an NPN transistor
Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are functionally isolated. 2. Select input transistors according to the following: Dielectric strength of the collector ≥ 50 V Leakage current < 1 µA
C-20
Self-powered Time Counter H7ET
PNP/NPN Universal DC Voltage Input Model Without Backlight No-voltage Input Model
1. Contact Input (Input by a Relay or Switch Contact)
Relay Relay Relay Input Reset Relay
1. Contact Input (Input by a Relay or Switch Contact)
Input
Reset
or Switch or Switch or Switch
or Switch
2. Solid-state Input
Open collector of a PNP transistor Open collector of a PNP transistor
Note: Use Relays and Switches that have high contact reliability because the current flowing from terminals 1 or 3 is as small as approx. 10 µA. It is recommended that OMRON's G3TA-IA/ID be used as the SSR. 2. Solid-state Input (Open Collector Input of an NPN Transistor)
Open collector of an NPN transistor Input Open collector of an NPN transistor
Input
Reset
Reset
or Open collector of an NPN transistor
or Open collector of an NPN transistor
Terminals 2 and 4 are internally connected.
or Switch
Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are functionally isolated. 2. Select input transistors according to the following: Dielectric strength of the collector ≥ 50 V Leakage current < 1 µA
Note: 1. Residual voltage in the output section of Proximity Sensors or Photoelectric Sensors becomes less than 0.5 V because the current flowing from terminals 1 or 3 is as small as approx. 10 µA, thus allowing easy connection. 2. Select input transistors according to the following: Dielectric strength of the collector ≥ 50 V Leakage current < 1 µA
AC/DC Multi-voltage Input Model
Relay
Input
Reset
Relay
or Switch
or Switch
or Open collector of an NPN transistor
Self-powered Time Counter
H7ET
C-21
Counters
Terminals 2 and 4 are internally connected.
Operation
I Operating Modes
H7ET Time Counter
Incrementing Operation (Up)
Reset
Timer input
Internal clock timer value Full-scale (Full-scale −0.1 (1))
Timer display values
Nomenclature
Front view
H7ET
Reset Key Reset the count value. Not operable under key-protect.
Time-range switch If the time-range setting is changed, the present value will not be held and so press the Reset Key on the front panel. Setting (see note)
Front panel
Concave side
Key-protect Switch The Reset Key is not operable while the key-protect switch is set to ON. Setting (see note)
Front panel
Key-protect OFF (default setting)
Time range H7ET-N@@-@@ H7ET-N@@1-@@ 0s to 999h59min59s (default setting)
Bottom view
Concave side
0.0h to 3999d23.9h
Concave side
ON
Terminal block
Concave side
0.0h to 999999.9h (default setting) 0.0min to 9999h59.9min
Terminal block
Note: Perform switch setting before mounting to a control panel.
C-22
Self-powered Time Counter H7ET
Dimensions
Note: All units are in millimeters unless otherwise indicated.
H7ET-N
Panel Cutout Separate mounting
40 min. 45+0.5 0
Dimensions with Flush Mounting Bracket
22.2+0.5 0
Dense mounting
(48 Units − 2.5) 0
+1.0
22.2+0.5 0
Waterproofing is not possible for dense mounting • When mounting, insert the Counter into the cutout, insert the adapter from the back and push in the Counter while making the gap between the front panel and the cutout panel as small as possible. Use screws to secure the Counter. If waterproofing is desired, insert the waterproof packing. • When several Counters are installed, ensure that the ambient temperature will not exceed specifications. • The appropriate thickness of the panel is 1 to 5 mm. Note: A Compact Flush Mounting Bracket (Y92F-35) can also be used. Refer to Accessories for details.
Self-powered Time Counter
H7ET
C-23
Counters
很抱歉,暂时无法提供与“H7ET-NFV1-B”相匹配的价格&库存,您可以联系我们找货
免费人工找货