0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
H7ET

H7ET

  • 厂商:

    ETC

  • 封装:

  • 描述:

    H7ET - Self-powered Time Counter - List of Unclassifed Manufacturers

  • 数据手册
  • 价格&库存
H7ET 数据手册
Self-powered Time Counter H7ET Counters • Seven digits, time range 0 to 3999d23.9h. • Dual time range: 999999.9 ←→ 3999d23.9h or 999h59m59s ←→ 9999h59.9m Model Number Structure I Model Number Legend H7ET - N 1 2 3 4 1. Count Input None: No-voltage input V: PNP/NPN universal DC voltage input FV: AC/DC multi-voltage input 2. Time Range None: 999999.9h/3999d23.9h 1: 999h59m59s/9999h59.9m 3. Case Color None: Light gray B: Black 4. Display None: 7-segment LCD without backlight H: 7-segment LCD with backlight Ordering Information I Time Counters Timer input Display 999999.9h ←→ 3999d23.9h (switchable) Light-gray body PNP/NPN universal DC volt- 7-segment LCD with backage input light 7-segment LCD AC/DC multi-voltage input No-voltage input 7-segment LCD 7-segment LCD H7ET-NV-H H7ET-NV H7ET-NFV H7ET-N Black body H7ET-NV-BH H7ET-NV-B H7ET-NFV-B H7ET-N-B Time range 999h59min59s ←→ 9999h59.9min (switchable) Light-gray body H7ET-NV1-H H7ET-NV1 H7ET-NFV1 H7ET-N1 Black body H7ET-NV1-BH H7ET-NV1-B H7ET-NFV1-B H7ET-N1-B I Accessories (Order Separately) Lithium Battery Wire-wrap Terminal (set of two terminals) Flush Mounting Adapter Y92S-36 Y92S-37 26 mm × 45.3 mm 27.5 mm × 52.5 mm 24.8 mm × 48.8 mm Note: The New H7E models are supplied with a Y92F-34 Mounting Bracket. Y92F-75 Y92F-76 Y92F-77B Compact Flush Mounting Bracket (See note.) Y92F-35 Self-powered Time Counter H7ET C-17 Specifications I General Item Operating mode Mounting method External connections Reset Display Number of digits Time range Timer input H7ET-NV-@ H7ET-NV-@H Accumulating Flush mounting Screw terminals External/Manual reset 7-segment LCD with or without backlight, zero suppression (character height: 8.6 mm) (see note 1) 7 0.0h to 999999.9h ←→ 0.0h to 3999d23.9h (switchable with switch) PNP/NPN univer- AC/DC multi-voltsal DC voltage in- age input put Light gray or black (-B models) Waterproof packing, flush mounting bracket, time unit labels (see note 2) UL863, CSA C22.2 No.14, Lloyds Conforms to EN61010-1/IEC61010-1 (pollution degree2/overvoltage category III) Conforms to VDE0106/P100 No-voltage input 0s to 999h59min59s ←→ 0.0min to 9999h59.9min (switchable with switch) PNP/NPN univer- AC/DC multi-voltsal DC voltage in- age input put No-voltage input H7ET-NFV-@ H7ET-N-@ H7ET-NV1-@ H7ET-NV1-@H H7ET-NFV1-@ H7ET-N1-@ Case color Attachment Approved standard Note: 1. Only PNP/NPN universal DC voltage input models (-H models) have a backlight. 2. “-hours”, “-d-h”, “-h-m”, and “-h-m-s” labels are included. I Ratings Item Supply voltage H7ET-NV@-@ H7ET-NV@-@H H7ET-NFV@-@ H7ET-N@-@ Backlight model: 24 VDC (0.3 W max.) Not required (powered by built-in battery) (for backlight) No-backlight model: Not required (powered by built-in battery) High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input impedance: Approx. 4.7 kΩ) High (logic) level: 24 to 240 VAC/VDC, 50/60 Hz Low (logic) level: 0 to 2.4 VAC/VDC, 50/ 60 Hz No voltage input Maximum short-circuit impedance: 10 kΩ max. Short-circuit residual voltage: 0.5 V max. Minimum open impedance: 750 kΩ min. 1s External reset and manual reset: Minimum signal width of 20 ms 0.98 N·m max. No voltage input Maximum short-circuit impedance: 10 kΩ max. Short-circuit residual voltage: 0.5 V max. Minimum open impedance: 750 kΩ min. Timer input Reset input Minimum pulse width Reset system Terminal screw tightening torque Ambient tempera- Operating: -10°C to 55°C (with no condensation or icing) Storage: -25°C to 65°C (with no condensation or icing) ture Ambient humidity Operating: 25% to 85% C-18 Self-powered Time Counter H7ET I Characteristics Item Time accuracy Insulation resistance H7ET-NV@-@ H7ET-NV@-H@ ±100 ppm (25°C) 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts, and between the backlight power supply and timer input terminals/reset terminals for backlight models 1,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying metal parts and between the backlight power supply and timer input terminals/reset terminals for backlight models 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts and between timer input terminals and reset terminals 3,700 VAC, 50/60 Hz for 1 min between timer input terminals and exposed non-current-carrying metal parts 2,200 VAC, 50/60 Hz for 1 min between reset terminals and exposed non-current-carrying metal parts and between timer input terminals and reset terminals 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts Counters H7ET-NFV@-@ H7ET-N@-@ Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying metal parts Impulse withstand voltage 4.5 kV between current-carrying termi- 4.5 kV between current-carrying termi- 4.5 kV between current-carrying terminal and exposed non-current-carrying nal and exposed non-current-carrying nal and exposed non-current-carrying metal parts metal parts metal parts 3 kV between timer input terminals and reset terminals Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) ±600 V (Between timer input terminals/ ±1.5 kV (Between timer input termiBetween reset terminals) nals) ±480 V (Between the backlight power ±500 V (Between reset terminals) supply terminals for backlight models) ±500 V (Between timer input terminals/ Between reset terminals) Noise immunity Static immunity Vibration resistance Shock resistance EMC ±8 kV (malfunction) Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions Malfunction: 200 m/s2 3 times each in 6 directions Destruction: 300 m/s2 3 times each in 6 directions (EMI) Emission Enclosure: (EMS) Immunity ESD: EN61326 EN55011 Group 1 class B EN61326 EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves: EN61000-4-3: 10 V/m (900 MHz ± 5 MHz) (level 3) Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power line (level 3) 2 kV I/O signal line (level 4) Front panel: IP66, NEMA4 with waterproof packing Terminal block: IP20 No-backlight model: Approx. 60 g Backlight model: Approx. 65 g Approx. 60 g Approx. 60 g Degree of protection Weight (see note) Note: Weight includes waterproof packing and flush mounting bracket. I Reference Value Item Battery life Value 10 years min. with continuous input at 25°C (lithium battery) Note The battery life is calculated according to the conditions in the left column and therefore is not a guaranteed value. Use these value as reference for maintenance or replacement. Self-powered Time Counter H7ET C-19 Connections I Terminal Arrangement Bottom view: View of the Time Counter rotated horizontally 180° Backlight Model No-backlight Model Backlight 24 VDC Timer input Reset input Timer input Reset input I Connections H7ET Time Counter PNP/NPN Universal DC Voltage Input Model With Backlight 1. Contact Input (Input by a Relay or Switch Contact) Relay Backlight 24 VDC Input Input Reset Relay 2. Solid-state Input Open collector of a PNP transistor Open collector of a Backlight PNP transistor 24 VDC Reset or Switch or Switch or Open collector of an NPN transistor or Open collector of an NPN transistor Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are functionally isolated. 2. Select input transistors according to the following: Dielectric strength of the collector ≥ 50 V Leakage current < 1 µA C-20 Self-powered Time Counter H7ET PNP/NPN Universal DC Voltage Input Model Without Backlight No-voltage Input Model 1. Contact Input (Input by a Relay or Switch Contact) Relay Relay Relay Input Reset Relay 1. Contact Input (Input by a Relay or Switch Contact) Input Reset or Switch or Switch or Switch or Switch 2. Solid-state Input Open collector of a PNP transistor Open collector of a PNP transistor Note: Use Relays and Switches that have high contact reliability because the current flowing from terminals 1 or 3 is as small as approx. 10 µA. It is recommended that OMRON's G3TA-IA/ID be used as the SSR. 2. Solid-state Input (Open Collector Input of an NPN Transistor) Open collector of an NPN transistor Input Open collector of an NPN transistor Input Reset Reset or Open collector of an NPN transistor or Open collector of an NPN transistor Terminals 2 and 4 are internally connected. or Switch Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are functionally isolated. 2. Select input transistors according to the following: Dielectric strength of the collector ≥ 50 V Leakage current < 1 µA Note: 1. Residual voltage in the output section of Proximity Sensors or Photoelectric Sensors becomes less than 0.5 V because the current flowing from terminals 1 or 3 is as small as approx. 10 µA, thus allowing easy connection. 2. Select input transistors according to the following: Dielectric strength of the collector ≥ 50 V Leakage current < 1 µA AC/DC Multi-voltage Input Model Relay Input Reset Relay or Switch or Switch or Open collector of an NPN transistor Self-powered Time Counter H7ET C-21 Counters Terminals 2 and 4 are internally connected. Operation I Operating Modes H7ET Time Counter Incrementing Operation (Up) Reset Timer input Internal clock timer value Full-scale (Full-scale −0.1 (1)) Timer display values Nomenclature Front view H7ET Reset Key Reset the count value. Not operable under key-protect. Time-range switch If the time-range setting is changed, the present value will not be held and so press the Reset Key on the front panel. Setting (see note) Front panel Concave side Key-protect Switch The Reset Key is not operable while the key-protect switch is set to ON. Setting (see note) Front panel Key-protect OFF (default setting) Time range H7ET-N@@-@@ H7ET-N@@1-@@ 0s to 999h59min59s (default setting) Bottom view Concave side 0.0h to 3999d23.9h Concave side ON Terminal block Concave side 0.0h to 999999.9h (default setting) 0.0min to 9999h59.9min Terminal block Note: Perform switch setting before mounting to a control panel. C-22 Self-powered Time Counter H7ET Dimensions Note: All units are in millimeters unless otherwise indicated. H7ET-N Panel Cutout Separate mounting 40 min. 45+0.5 0 Dimensions with Flush Mounting Bracket 22.2+0.5 0 Dense mounting (48 Units − 2.5) 0 +1.0 22.2+0.5 0 Waterproofing is not possible for dense mounting • When mounting, insert the Counter into the cutout, insert the adapter from the back and push in the Counter while making the gap between the front panel and the cutout panel as small as possible. Use screws to secure the Counter. If waterproofing is desired, insert the waterproof packing. • When several Counters are installed, ensure that the ambient temperature will not exceed specifications. • The appropriate thickness of the panel is 1 to 5 mm. Note: A Compact Flush Mounting Bracket (Y92F-35) can also be used. Refer to Accessories for details. Self-powered Time Counter H7ET C-23 Counters

很抱歉,暂时无法提供与“H7ET”相匹配的价格&库存,您可以联系我们找货

免费人工找货