OM1905NMM OM1915NMM OM1912NMM
HERMETIC SURFACE MOUNT FIXED VOLTAGE NEGATIVE REGULATORS APPROVED TO DESC DRAWINGS
Three Terminal, Fixed Voltage, 1.5 Amp Precision Negative Regulators In Hermetic Surface Mount Package
FEATURES
• • • • • • Hermetic Surface Mount Package Output Voltages: -5V, -12V, -15V Output Voltages Set Internally To ±1% Built-In Thermal Overload Protection Short Circuit Current Limiting Product Is Available Hi-Rel Screened
DESCRIPTION
These three terminal negative regulators are supplied in a hermetically sealed surface mount package. All protective features are designed into the circuit including thermal shutdown, current limiting and safe-area control. With heat sinking, they can deliver over 1.5 amps of output current. These units feature internally trimmed output voltages to ±1% of nominal voltage. Standard voltages are -5V, -12V, and -15V. These units are ideally suited for Military applications where a hermetic surface mount package is required.
PART NUMBER DESIGNATOR
Standard Military Drawing Number 5962-8874601 NX 5962-8874701 NX 5962-8874801 NX Omnirel Part Number OM1905NMM OM1912NMM OM1915NMM
3.5
4 11 R0
3.5 - 53
OM1905NMM - OM1915NMM
ABSOLUTE MAXIMUM RATINGS @ 25°C
Input Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -35 V Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . .- 55°C to + 150°C Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C Typical Power/Thermal Charateristics: Rated Power @ 25° C TC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15W TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3W Thermal Resistance θJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5°C/W aa θJA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120°C/W
ELECTRICAL CHARACTERISTICS -5 Volt
Parameter Output Voltage Symbol VOUT
VIN = -10V, Io = 500mA, -55°C ≤ TA ≤ 125°C (unless otherwise specified) Min. -4.95 Max. -5.05 -5.15 Unit V V
Test Conditions TA = 25°C VIN = -7.5V to -20V IO = 5mA to 1.0 A, P < 15W
•
-4.85
Line Regulation (Note 1) (Note 4)
VRLINE
VIN = -7.5V to -20V
12
mV mV mV mV mV mV mV mV mA mA mA
•
VIN = -8.0V to -12V
25 5
•
Load Regulation (Note 1) IO = 250mA to 750 mA VRLOAD IO = 5mA to 1.5 Amp
12 20
• •
25 15 30 2.5
Standby Current Drain
ISCD ∆ISCD (Line) ∆ISCD (Load) VDO IO (pk) IDS ∆VIN ∆VOUT NO ∆VOUT ∆t ∆VOUT = 100mV, IO = 1.0A TA = 25°C VIN = -35V IO = 5mA to 1000mA VIN = -7.0V to -20V
Standby Current Drain Change With Line Standby Current Drain Change With Load Dropout Voltage Peak Output Current Short Circuit Current (Note 2) Ripple Rejection
• • • •
1.5
3.0 0.4
0.4
mA
2.5 3.3 1.2
V A A A dB dB
•
f =120 Hz, ∆VIN = -10V (Note 3) TA = 25°C, f =10 Hz to 100KHz TA = 25°C, t = 1000 hrs. 63
2.8
•
60 40
Output Noise Voltage (Note 3) Long Term Stability
µV/V RMS
75
mV
3.5
(Note 3)
Notes: 1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately. 2. Short Circuit protection is only assured up to VIN = -35V. 3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range.
3.5 - 54
OM1905NMM - OM1915NMM ELECTRICAL CHARACTERISTICS -12 Volt
Parameter Output Voltage Symbol VOUT VIN = -19V, Io = 500mA, -55°C ≤ TA ≤ 125°C (unless otherwise specified) Min. -11.88 Max. -12.12 -12.36 Unit V V
Test Conditions TA = 25°C VIN = -14.5V to -27V IO = 5mA to 1.0 A, P < 15W
•
-11.64
Line Regulation (Note 1) (Note 4)
VRLINE
VIN = -14.5V to -27V
20
mV mV mV mV mV mV mV mV mA mA mA
•
VIN = -16V to -22V
50 10
•
Load Regulation (Note 1) IO = 250mA to 750 mA VRLOAD IO = 5mA to 1.5 Amp
30 32
• •
60 16 30 3.5
Standby Current Drain
ISCD ∆ISCD (Line) ∆ISCD (Load) VDO IO (pk) IDS ∆VIN ∆VOUT NO ∆VOUT ∆t ∆VOUT = 100mV, IO = 1.0A TA = 25°C, IO = 5mA to 1A VIN = -35V IO = 5mA to 1000mA VIN = -14.5V to -27V
Standby Current Drain Change With Line Standby Current Drain Change With Load Dropout Voltage Peak Output Current Short Circuit Current (Note 2) Ripple Rejection
• • • •
1.5
4.0 0.8
0.5
mA
1.8 3.3 1.2
V A A A dB dB
•
f =120 Hz, ∆VIN = -10V (Note 3) TA = 25°C, f =10 Hz to 100KHz TA = 25°C, t = 1000 hrs. 56
2.8
•
53 40
Output Noise Voltage (Note 3) Long Term Stability (Note 3)
µV/V RMS
120
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately. 2. Short Circuit protection is only assured up to VIN = -35V. 3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range. 4. Minimum load current for full line regulation = 5 mA.
MECHANICAL OUTLINE
CONNECTION DIAGRAM
.140 .015 .075
.140
.140 .075
.157
1
2
.030 MIN.
Pin 1 Ground Pin 2 Output Pin 3 Input
3.5
.415
3
.062
.375
3.5 - 55
OM1905NMM - OM1915NMM
ELECTRICAL CHARACTERISTICS -15 Volt
Parameter Output Voltage Symbol VOUT VIN = -23V, Io = 500mA, -55°C ≤ TA ≤ 125°C (unless otherwise specified) Min. -14.85 Max. -15.15 -15.45 Unit V V
Test Conditions TA = 25°C VIN = -17.5V to -30V IO = 5mA to 1.0 A, P < 15W
•
-14.55
Line Regulation (Note 1) (Note 4)
VRLINE
VIN = -17.5V to -30V
25
mV mV mV mV mV mV mV mV mA mA mA
•
VIN = -20V to -26V
50 15
•
Load Regulation (Note 1) IO = 250mA to 750 mA VRLOAD IO = 5mA to 1.5 Amp
25 35
• •
75 21 45 6.0
Standby Current Drain
ISCD ∆ISCD (Line) ∆ISCD (Load) VDO IO (pk) IDS ∆VIN ∆VOUT NO ∆VOUT ∆t ∆VOUT = 100mV, IO = 1.0A TA = 25°C VIN = -35V IO = 5mA to 1000 mA VIN = -17.5V to -30V
Standby Current Drain Change With Line Standby Current Drain Change With Load Dropout Voltage Peak Output Current Short Circuit Current (Note 2) Ripple Rejection
• • • •
1.5
6.5 0.8
0.5
mA
2.5 3.3 1.2
V A A A dB dB
•
f =120 Hz, ∆VIN = -10V (Note 3) TA = 25°C, f =10 Hz to 100KHz TA = 25°C, t = 1000 hrs. 53
2.8
•
50 40
Output Noise Voltage (Note 3) Long Term Stability (Note 3)
µV/V RMS
150
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately. 2. Short Circuit protection is only assured up to VIN = -35V. 3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range.
TYPICAL PERFORMANCE CHARACTERISTICS
PEAK OUTPUT
3.5 3 2.5
DROPOUT VOLTAGE
100
RIPPLE REJECTION
Output Current (A)
Tj = -55°C
2
3.5
2
Tj = 25°C
1.5
IOUT = 500mA
Ripple Rejection (dB)
2.5
IOUT = 1A
80
VOUT = 5V
Output Current (A)
60
1.5 1 0.5
∆VOUT = 100mV Tj = 150°C
1
IOUT = 0A
40
VIN - V = 8VDC +3.5Vrms IOUT = 1A Tj = 25°C
0.5
∆VOUT = 100MV
20
0
5
10
15
20
25
30
35
0 -75-50 -25 0
2 5 5 0 7 5 100 125150
0 10 100 1k 10k
Input To Output Differential (V)
Junction Temperature (°C)
Frequency (Hz)
很抱歉,暂时无法提供与“OM1905NMM”相匹配的价格&库存,您可以联系我们找货