UHP-3-3-30-D48

UHP-3-3-30-D48

  • 厂商:

    ETC

  • 封装:

  • 描述:

    UHP-3-3-30-D48 - Single Output UHP Models - List of Unclassifed Manufacturers

  • 数据手册
  • 价格&库存
UHP-3-3-30-D48 数据手册
® ® PRELIMINARY INNOVATION and EXCELLENCE Single Output UHP Models 3.3 Volts @ 30 Amps 100 Watt, DC/DC Converters Features s s s s s s s s s s s s s Regulated 3.3V output @ 30 Amps Input range: 36V-75V Open frame: 2.3" x 2.4" x 0.47" Industry-standard package/pinout Light weight: 2.24 ounces (63.5g) Remose sense, Trim, On/Off Control High efficiency: 89% Fully isolated, 1500Vdc guaranteed Input under and overvoltage shutdown Output overvoltage protection Short circuit protection; thermal shutdown UL1950 and EN60950 safety approvals CE mark DATEL's fully isolated UHP series of DC/DC converters affords users a practical solution for their low-voltage/high-current applications. With an input voltage range of 36 to 75 Volts, the UHP-3.3/30-D48 delivers 30 Amps of output current from a fully regulated 3.3V output. Using both surface-mount technology and planar magnetics, these converters are manufactured on a 2.3" x 2.4" open-frame package with an industry-standard pinout configuration. UHP converters utilize a full-bridge, fixed-frequency topology along with synchronous output rectification to achieve a high efficiency of 89%. This efficiency, coupled with the open-frame package that allows unrestricted air flow, reduces internal component temperatures thereby allowing operation at elevated ambient temperatures. These DC/DC's provide output trim, sense pins and primary side on/off control (available with positive or negative logic) or sync. Standard features also include input overvoltage and undervoltage shutdown circuitry, output overvoltage protection, output short-circuit and current limiting protection and thermal shutdown. All devices meet IEC950, UL1950 and EN60950 safety standards and carry the CE mark (meet LVD) requirements). CB reports are available on request. +INPUT +3.3V OUTPUT OUTPUT RETURN SECONDARY SWITCH CONTROL PRIMARY SWITCH CONTROL –INPUT PWM CONTROLLER +SENSE OPTO ISOLATION REFERENCE & ERROR AMP –SENSE UV & OV COMPARATORS THERMAL SHUTDOWN Figure 1. Simplified Schematic DATEL, Inc., Mansfield, MA 02048 (USA) · Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 · Email: sales@datel.com · Internet: www.datel.com XHP Series 3.3V @ 30A, SINGLE OUTPUT DC/DC CONVERTERS Performance Specifications and Ordering Guide Output Model UHP-3.3/30-D48 ➀ ➁ ➂ ➃ ➀ Input Regulation (Max.) Line ±1% VOUT (Volts) 3.3 IOUT ➁ (Amps) 30 R/N (mVp-p) ➁ Typ. 80 Max. 120 Load ➂ ±1% VIN Nom. (Volts) 48 Range (Volts) 36-75 IIN ➃ (mA) 120/2340 Efficiency Min. 86.5 Typ. 88% Package (Case, Pinout) C27, P17 Typical at TA = +25°C under nominal line voltage and full-load conditions. Ripple/Noise (R/N) measured over a 20MHz bandwidth with 10µFtantalum and 1µF ceramic output capacitors. Tested from no load to 100% load. Nominal line voltage, no load/full load condition. PA R T N U M B E R S T R U C T U R E UHP - 3.3 / 30 - D48 N Unipolar High-Power Series Nominal Output Voltage: 3.3 Volts Maximum Output Current: 30 Amps Add "N" or "S" suffix as desired Input Voltage Range: D48 = 36-75 Volts (48V nominal) Part Number Suffixes UHP 30 Amp DC/DC's are designed so a negative logic on/off control ("N" suffix) or a Sync function ("S" suffix) can be added in the pin 3 position. No Suffix On/Off Control function (positive polarity) N S Negative polarity on/off control Sync function M E C H A N I C A L S P E C I FI C A T I O N S 2.30 (58.42) 0.39 (9.91) STANDOFF WIDTH 0.056 (1.42) 0.120 MIN. (3.05) 1.900 (48.26) PIN DIAMETERS: PINS 1-4, 6-8 0.040 ±0.002 (1.016 ±0.051) PINS 5, 9 0.080 ±0.002 (2.032 ±0.051) I/O Connections Pin 1 2 3 4 5 6 7 8 9 Function P17 –Input No Pin On/Off Control +Input +Output +Sense Trim –Sense –Output 0.20 (5.08) 1 9 8 Case C27 3 7 6 0.400 (10.16) 0.700 (17.78) 1.000 (25.40) 1.400 (35.56) 2.40 (60.96) 4 5 0.50 (12.70) BOTTOM VIEW 2 3.3V @ 30A, SINGLE OUTPUT CONVERTERS U HP Models Performance/Functional Specifications Typical @ TA = +25°C under nominal line voltage, full-load conditions, unless noted. ➀ DynaEnvironmental MTBF ➆ Bellcore, ground fixed, full power 25°C ambient TBD million hours +52°C To +100°C (See Derating Curves) TBD –40 to +120°C Input Input Voltage Range Overvoltage Shutdown Start-Up Threshold Undervoltage Shutdown Input Current: Normal Operating Conditions Standby Mode: Off, OV, UV, Thermal Shutdown Input Reflected Ripple Current: Source Impedance Internal Input Filter Type Reverse-Polarity Protection On/Off Control (Pin 3): ➂ ➃ ➅ 36-75 Volts (48V nominal) 77-81 Volts (79V typical) 34-36 Volts (35V typical) 32.5-34.5 Volts (33.5V typical) See Ordering Guide TBD typical
UHP-3-3-30-D48 价格&库存

很抱歉,暂时无法提供与“UHP-3-3-30-D48”相匹配的价格&库存,您可以联系我们找货

免费人工找货