0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
25CPV240

25CPV240

  • 厂商:

    ETC1

  • 封装:

  • 描述:

    25CPV240 - Phase Control Modules - List of Unclassifed Manufacturers

  • 数据手册
  • 价格&库存
25CPV240 数据手册
Series CPV Phase Control Modules • 120 & 240 Vac Models • 0-5 Vdc Phase Control Models CPV120 and CPV240 auxiliary function modules provide control of the phased turn-on of a solid state relay, in response to the application of a 0-5 Vdc control signal. They must be used with Crydom Series 1 (-10) random turn-on solid state relays. Consult factory about use with 480 Vac loads. For a complete set (control module and solid state relay) order 10CPV120, 25CPV120, etc. Manufactured in Crydom’s ISO 9002 Certified facility for optimum product performance and reliability. MODEL NUMBERS 120 Vac 240 Vac 10CPV120 10CPV240 25CPV120 25CPV240 40CPV120 50CPV240 75CPV240 90CPV240 RELAY OUTPUT SPECIFICATIONS Œ Operating Voltage Range (47-63 Hz) [Vrms] Load Current Range Ž [Arms] Transient Overvoltage [Vpk] Max. Surge Current, (16.6ms) [Apk] Max. On-State Voltage Drop @ Rated Current [Vpk] Thermal Resistance Junction to Case [RθJC] °C/W Maximum I2 t for Fusing, (8.3 msec.) [A2sec] Max. Off-State Leakage Current @ Rated Voltage [mArms] Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] Max. Turn-On Time [msec] Max. Turn-Off Time Power Factor (Min.) with Max. Load 90-140 (120 Vac Models) 180-280 (240 Vac Models) .04-10 .04-25 .04-50 .04-75 .04-90 400 (120 Vac models) 600 (240 Vac models) 120 1.6 1.48 60 10.0 500 0.02 1/ 2 250 1.6 1.02 260 10.0 500 0.02 1/ 2 625 1.6 0.63 1620 10.0 500 0.02 1/ 2 1000 1.6 0.31 4150 10.0 500 0.02 1/ 2 1200 1.6 0.28 6000 10.0 500 0.02 1/ 2 cycle 0.5 cycle 0.5 cycle 0.5 cycle 0.5 cycle 0.5 CONTROL MODULE INPUT SPECIFICATIONS Œ Logic Supply Range (Terminal 3A) Typical Supply Current Control Voltage Range (Terminal 3B) Nominal Control Input Impedance Min. Turn-Off Voltage DC CONTROL 3.5-10Vdc 1.6mA @ 5Vdc 0-5 Vdc 1500 Ohms 1.0 CONTROL MODULE OUTPUT (Terminal 4B – Input to Relay) Œ Max. Off-State Operating Voltage Max. Load Current (Sink) Max. On-State Voltage @ 3mA Max. Off-State Leakage @ 10Vdc 36 Vdc 3.0 mA 0.5 Vdc 1.0 µAdc ©1998 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES Œ All parameters at 25ºC unless otherwise specified.  Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 Ž Heat sinking required (Relay Only), see Series 1 data sheet. FastFax Document No. 203 SERIES CPV.040898, PAGE 1 OF 2 For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 • fax (44)1202 812340 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49)871 935405 • fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany Series CPV Phase Control Modules GENERAL SPECIFICATIONS Dielectric Strength, Signal to Load Dielectric Strength, Signal to Base Ambient Operating Temperature Range Ambient Storage Temperature Range MECHANICAL SPECIFICATIONS Weight: (typical) Encapsulation: 4000 Vrms 4000 Vrms -30 to 80ºC -40 to 125ºC 3.0 oz. (43g) Thermally Conductive Epoxy AVAILABLE OPTIONS CPV120 Control Module Only (120 Vac line) CPV240 Control Module Only (120 Vac line) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 1.10 (27.9) .50 (12.7) .270 (2) (6.9) FASTON TERMINAL .250 X .032 4 PLCS. DERATING CURVES – See Series 1 1.87 (47.5) 2.30 (58.4) 1.70 (43.2) 1A 1B Positive Supply (+) (5Vdc) Control Voltage (+) (0 to 5Vdc) Common (–) Line 2B 2A .270 FASTON (6.9) TERMINAL .187 X .032 4 PLCS. .78 (19.8) .87 (22.2) -4A 4B CONTROL MODULE + 3B 3A 1.00 (25.4) 1.80 (45.7) All dimensions are in inches (millimeters) Load OUTPUT 1 –10 RELAY 2 4 INPUT 3 Notes 1. Following pins may be interchanged: 1A & 1B, 2A & 2B. 2. Pin 4A & 4B may not be interchanged, nor may pins 3A & 3B. 3. The line and load may be interchanged. ©1998 CRYDOM CORP, Specifications subject to change without notice. FastFax Document No. 203 SERIES CPV.040898, PAGE 2 OF 2 For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 • fax (44)1202 812340 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49)871 935405 • fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany
25CPV240 价格&库存

很抱歉,暂时无法提供与“25CPV240”相匹配的价格&库存,您可以联系我们找货

免费人工找货