25CPV240

25CPV240

  • 厂商:

    ETC1

  • 封装:

  • 描述:

    25CPV240 - Phase Control Modules - List of Unclassifed Manufacturers

  • 详情介绍
  • 数据手册
  • 价格&库存
25CPV240 数据手册
Series CPV Phase Control Modules • 120 & 240 Vac Models • 0-5 Vdc Phase Control Models CPV120 and CPV240 auxiliary function modules provide control of the phased turn-on of a solid state relay, in response to the application of a 0-5 Vdc control signal. They must be used with Crydom Series 1 (-10) random turn-on solid state relays. Consult factory about use with 480 Vac loads. For a complete set (control module and solid state relay) order 10CPV120, 25CPV120, etc. Manufactured in Crydom’s ISO 9002 Certified facility for optimum product performance and reliability. MODEL NUMBERS 120 Vac 240 Vac 10CPV120 10CPV240 25CPV120 25CPV240 40CPV120 50CPV240 75CPV240 90CPV240 RELAY OUTPUT SPECIFICATIONS Œ Operating Voltage Range (47-63 Hz) [Vrms] Load Current Range Ž [Arms] Transient Overvoltage [Vpk] Max. Surge Current, (16.6ms) [Apk] Max. On-State Voltage Drop @ Rated Current [Vpk] Thermal Resistance Junction to Case [RθJC] °C/W Maximum I2 t for Fusing, (8.3 msec.) [A2sec] Max. Off-State Leakage Current @ Rated Voltage [mArms] Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] Max. Turn-On Time [msec] Max. Turn-Off Time Power Factor (Min.) with Max. Load 90-140 (120 Vac Models) 180-280 (240 Vac Models) .04-10 .04-25 .04-50 .04-75 .04-90 400 (120 Vac models) 600 (240 Vac models) 120 1.6 1.48 60 10.0 500 0.02 1/ 2 250 1.6 1.02 260 10.0 500 0.02 1/ 2 625 1.6 0.63 1620 10.0 500 0.02 1/ 2 1000 1.6 0.31 4150 10.0 500 0.02 1/ 2 1200 1.6 0.28 6000 10.0 500 0.02 1/ 2 cycle 0.5 cycle 0.5 cycle 0.5 cycle 0.5 cycle 0.5 CONTROL MODULE INPUT SPECIFICATIONS Œ Logic Supply Range (Terminal 3A) Typical Supply Current Control Voltage Range (Terminal 3B) Nominal Control Input Impedance Min. Turn-Off Voltage DC CONTROL 3.5-10Vdc 1.6mA @ 5Vdc 0-5 Vdc 1500 Ohms 1.0 CONTROL MODULE OUTPUT (Terminal 4B – Input to Relay) Œ Max. Off-State Operating Voltage Max. Load Current (Sink) Max. On-State Voltage @ 3mA Max. Off-State Leakage @ 10Vdc 36 Vdc 3.0 mA 0.5 Vdc 1.0 µAdc ©1998 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES Œ All parameters at 25ºC unless otherwise specified.  Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 Ž Heat sinking required (Relay Only), see Series 1 data sheet. FastFax Document No. 203 SERIES CPV.040898, PAGE 1 OF 2 For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 • fax (44)1202 812340 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49)871 935405 • fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany Series CPV Phase Control Modules GENERAL SPECIFICATIONS Dielectric Strength, Signal to Load Dielectric Strength, Signal to Base Ambient Operating Temperature Range Ambient Storage Temperature Range MECHANICAL SPECIFICATIONS Weight: (typical) Encapsulation: 4000 Vrms 4000 Vrms -30 to 80ºC -40 to 125ºC 3.0 oz. (43g) Thermally Conductive Epoxy AVAILABLE OPTIONS CPV120 Control Module Only (120 Vac line) CPV240 Control Module Only (120 Vac line) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 1.10 (27.9) .50 (12.7) .270 (2) (6.9) FASTON TERMINAL .250 X .032 4 PLCS. DERATING CURVES – See Series 1 1.87 (47.5) 2.30 (58.4) 1.70 (43.2) 1A 1B Positive Supply (+) (5Vdc) Control Voltage (+) (0 to 5Vdc) Common (–) Line 2B 2A .270 FASTON (6.9) TERMINAL .187 X .032 4 PLCS. .78 (19.8) .87 (22.2) -4A 4B CONTROL MODULE + 3B 3A 1.00 (25.4) 1.80 (45.7) All dimensions are in inches (millimeters) Load OUTPUT 1 –10 RELAY 2 4 INPUT 3 Notes 1. Following pins may be interchanged: 1A & 1B, 2A & 2B. 2. Pin 4A & 4B may not be interchanged, nor may pins 3A & 3B. 3. The line and load may be interchanged. ©1998 CRYDOM CORP, Specifications subject to change without notice. FastFax Document No. 203 SERIES CPV.040898, PAGE 2 OF 2 For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 • fax (44)1202 812340 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49)871 935405 • fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany
25CPV240
### 物料型号 - 120 Vac型号:10CPV120、25CPV120、40CPV120 - 240 Vac型号:10CPV240、25CPV240、50CPV240、75CPV240、90CPV240

### 器件简介 Series CPV120和CPV240辅助功能模块提供对固态继电器的分相触发控制,响应于0-5Vdc控制信号。它们必须与Crydom Series 1随机触发固态继电器一起使用。如需用于480 Vac负载,请咨询工厂。

### 引脚分配 - 1A & 1B:可以互换 - 2A & 2B:可以互换 - 4A & 4B:不可以互换,3A & 3B也不能互换 - 线路和负载:可以互换

### 参数特性 - 操作电压范围:90-140 Vrms(120 Vac型号),180-280 Vrms(240 Vac型号) - 负载电流范围:0.04-10 Arms至0.04-90 Arms不等 - 瞬态过电压:400 Vpk(120 Vac型号),600 Vpk(240 Vac型号) - 最大涌流电流:120 Apk至1200 Apk不等 - 最大导通电压降:1.6 Vpk - 热阻:1.48 °CW至0.28 °CW不等 - 最大I2t值:60 A2sec至6000 A2sec不等 - 最大关断状态漏电流:10.0 mArms - 最小关断状态dv/dt:500 V/sec - 最大导通时间:0.02 msec - 最大关断时间:1/2周期 - 功率因数(最小):0.5

### 功能详解 - 控制模块输入规格:逻辑供电范围3.5-10Vdc,典型供电电流1.6mA@5Vdc,控制电压范围0-5Vdc,控制输入阻抗1500欧姆。 - 控制模块输出:最大关断状态工作电压36Vdc,最大负载电流(sink)3.0 mA,最大导通状态电压@3mA 0.5Vdc。

### 应用信息 用于控制固态继电器的分相触发,适用于需要精确控制相位触发的应用,如电机控制、照明控制等。

### 封装信息 - 重量:3.0 oz(43g) - 封装:热导电环氧树脂
25CPV240 价格&库存

很抱歉,暂时无法提供与“25CPV240”相匹配的价格&库存,您可以联系我们找货

免费人工找货