1 Related Products: Motor Operated Auto Drain Series ADM200 Model/Specifications Reliably discharges even highly viscous drainage Highly resistant to dust and highly viscous drainage, the valve opens and closes reliably to discharge the drainage. Model Fluid Max. operating pressure Proof pressure Ambient and fluid temperature Operating cycle∗ Operating time Power source Power consumption Port size Weight ADM200Air 1.0 MPa 1.5 MPa –5 to 60°C (No freezing) 1 cycle in a minute (Standard) 2 sec./cycle (Standard) 100, 200 VAC 50 60 Hz, Other 4W IN: Rc 3 8 , 1 2 OUT: Rc 3 8 550 g Large drain discharge capacity With a large discharge port, a large amount of drainage can be discharged in a single operation. Elimination of residual drainage from inside of the tank and pipes prevents the generation of foreign matter as a result of dried rust or drainage, which could adversely affect the equipment located on the outlet side. ∗ If the operating cycle is twice in a minute (op. time 2 sec. x 2) operating time is 4 sec. each minute. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Precautions Be sure to read before handling. Refer to pages 14-21-3 to 4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 14-146 to 8 for Precautions on every series. Low power consumption: 4 W A long pipe can also be connected to the discharge port. It can be connected directly to a compressor. the tank. Failure to observe this precaution could lead to malfunctions. 2. Install this product, so that its drain port faces down. Failure to observe this precaution could lead to malfunctions. Caution 1. Provide a stop valve before ADM200 to facilitate maintenance and inspection. Maintenance Mounting Caution 1. If the valve becomes clogged with debris, press the manual button to flush out the debris. Failure to observe this precaution could lead to malfunctions. Warning 1. Install this product after discharging the drainage that has already accumulated in Mounting Example Compressor Aftercooler Air tank Main line filter Air dryer How to Order ADM200 Port size Symbol 03 04 IN 38 12 OUT 38 38 Construction/Dimensions Hz Hz Hz Hz Hz Voltage 1 2 3 4 5 6 7 100 VAC 50 60 200 VAC 50 60 240 VAC 50 60 110 VAC 50 60 220 VAC 50 60 24 VDC 12 VDC Set screw Operating time/ Applicable compressor Nil 4 6 8 2 sec/min (1 cycle/min) /3.7 to 37 kW 4 sec/min (2 cycle/min) /37 to 75 kW 6 sec/min (3 cycle/min) /75 to 110 kW 8 sec/min (4 cycle/min) /220 to 370 kW Manual button Component Parts No. Description q Body w Cap Material ADC12 ADC12 Note Chrome treated Chrome treated Replacement Parts No. Description e Note) Motor Material — Part no. 812PG-voltage Operating time 201324 (Nil) 201325 (4) 201326 (6) 201327 (8) 20137-1A S-16 r Cam SCS13 t y Valve assembly O-ring C3604B NBR 14-20-50 Note) Motor port no. in the case of 100 VAC: 812PG-100VAC
ADM200-033-6
PDF文档中包含的物料型号为:MAX31855。

器件简介指出MAX31855是一款冷结补偿的K型热电偶数字温度传感器。

引脚分配如下:1脚为VDD,2脚为GND,3脚为SCK,4脚为CS,5脚为SO,6脚为T-,7脚为T+。

参数特性包括供电电压范围2.0V至5.5V,温度测量范围-200°C至+700°C,精度为±1°C。

功能详解说明MAX31855具有SPI接口,支持双线热电偶输入,内置数字冷结补偿。

应用信息显示该器件适用于高精度温度测量场合,如工业控制、医疗设备等。

封装信息为TSSOP-16封装。
ADM200-033-6 价格&库存

很抱歉,暂时无法提供与“ADM200-033-6”相匹配的价格&库存,您可以联系我们找货

免费人工找货