ADM200-035-8 数据手册
1 Related Products: Motor Operated Auto Drain Series ADM200 Model/Specifications Reliably discharges even highly viscous drainage Highly resistant to dust and highly viscous drainage, the valve opens and closes reliably to discharge the drainage. Model Fluid Max. operating pressure Proof pressure Ambient and fluid temperature Operating cycle∗ Operating time Power source Power consumption Port size Weight ADM200Air 1.0 MPa 1.5 MPa –5 to 60°C (No freezing) 1 cycle in a minute (Standard) 2 sec./cycle (Standard) 100, 200 VAC 50 60 Hz, Other 4W IN: Rc 3 8 , 1 2 OUT: Rc 3 8 550 g Large drain discharge capacity With a large discharge port, a large amount of drainage can be discharged in a single operation. Elimination of residual drainage from inside of the tank and pipes prevents the generation of foreign matter as a result of dried rust or drainage, which could adversely affect the equipment located on the outlet side. ∗ If the operating cycle is twice in a minute (op. time 2 sec. x 2) operating time is 4 sec. each minute. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Precautions Be sure to read before handling. Refer to pages 14-21-3 to 4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 14-146 to 8 for Precautions on every series. Low power consumption: 4 W A long pipe can also be connected to the discharge port. It can be connected directly to a compressor. the tank. Failure to observe this precaution could lead to malfunctions. 2. Install this product, so that its drain port faces down. Failure to observe this precaution could lead to malfunctions. Caution 1. Provide a stop valve before ADM200 to facilitate maintenance and inspection. Maintenance Mounting Caution 1. If the valve becomes clogged with debris, press the manual button to flush out the debris. Failure to observe this precaution could lead to malfunctions. Warning 1. Install this product after discharging the drainage that has already accumulated in Mounting Example Compressor Aftercooler Air tank Main line filter Air dryer How to Order ADM200 Port size Symbol 03 04 IN 38 12 OUT 38 38 Construction/Dimensions Hz Hz Hz Hz Hz Voltage 1 2 3 4 5 6 7 100 VAC 50 60 200 VAC 50 60 240 VAC 50 60 110 VAC 50 60 220 VAC 50 60 24 VDC 12 VDC Set screw Operating time/ Applicable compressor Nil 4 6 8 2 sec/min (1 cycle/min) /3.7 to 37 kW 4 sec/min (2 cycle/min) /37 to 75 kW 6 sec/min (3 cycle/min) /75 to 110 kW 8 sec/min (4 cycle/min) /220 to 370 kW Manual button Component Parts No. Description q Body w Cap Material ADC12 ADC12 Note Chrome treated Chrome treated Replacement Parts No. Description e Note) Motor Material — Part no. 812PG-voltage Operating time 201324 (Nil) 201325 (4) 201326 (6) 201327 (8) 20137-1A S-16 r Cam SCS13 t y Valve assembly O-ring C3604B NBR 14-20-50 Note) Motor port no. in the case of 100 VAC: 812PG-100VAC
ADM200-035-8
1. 物料型号: - 型号为ADM200。

2. 器件简介: - ADM200是一款电动自动排水阀,能够可靠地排放高粘度的排水,具有大型排放口,能够一次性排放大量排水,并且消耗功率低(4W)。它可以连接到压缩机,并且消除了由于干燥锈蚀或排水而产生的异物,从而保护设备。

3. 引脚分配: - 端口尺寸: - IN: Rc 1/2 或 3/8 - OUT: Rc 3/4 - 电压: - 100 VAC 50/Hz - 200 VAC 50/Hz - 240 VAC 59/Hz - 110 VAC 59/Hz - 220 VAC 59/Hz - 24VDC - 12VDC

4. 参数特性: - 最大工作压力:1.0 MPa - 校验压力:1.5 MPa - 环境和流体温度:-5至60°C(不结冰) - 操作周期:每分钟1个周期(标准) - 操作时间:每个周期2秒(标准) - 电源:100, 200 VAC 50 Hz,其他 - 功耗:4W - 重量:550g

5. 功能详解: - ADM200能够可靠地打开和关闭以排放排水,具有大型排放口,能够一次性排放大量排水。消除了由于干燥锈蚀或排水而产生的异物,从而保护设备。功耗低,可以连接到压缩机。

6. 应用信息: - ADM200适用于需要自动排水的场合,尤其是在处理高粘度排水时。它可以连接到压缩机,并能够可靠地排放排水。

7. 封装信息: - 组件部件: - ① 体:ADC12,镀铬处理 - ② 盖:ADC12,镀铬处理 - ③ 电机:型号为812PG,电压根据选择不同 - ④ 凸轮:SCS13,操作时间不同型号对应不同的操作时间 - ⑤ 阀组件:C3604B,型号为20137-1A - ⑥ O型圈:NBR,型号为S-16