AR-B2103 Features
Contact resistance: 100m ohms max Contact ratings: AC125V/1A or DC30V/3A (Resistive Load) Operation time: 8 msec max Release time: 8 msec max Output status read back 16 LED indicator for each channel Connector: 37-pin D-type (ext. AR-B9007) Isolation: 2100VDC isolation acrosser open contacts 1400VDC isolation between coil and contacts For IBM PC/XT/AT personal computers and compatible Dimensions: 175mm x 108mm
Specifications
General
Number of Outputs Max Switching Power Max Switching Voltage Max Switching Current Contact Rating Contact Resistance Operate Time Release Time Bounce Time Isolation Life Expectancy Varistor Voltage Varistor power Active Indicators I/O Address Power Consumption Dimensions Applications 12 Form A (SPST) and 4 Form C (SPDT) relays Resistive load - AC 250VA, DC 120W, Inductive load - AC 125VA, DC 60W 250VAC, 220VDC 4A Resistive load - AC 125V, 1.0A or DC 30V, 3A, Inductive load - AC 125V, 0.6A or DC 30V, 2A 100 milli ohms maximum (Initial value) 8mS maximum at the rated voltage 8mS maximum at the rated voltage 8mS maximum Contact and coil - 1500Vrms, 2100VDC, Contact to contact - 1000Vrms, 1400VDC 100 million. (Ref. 10VDC, 10ma) 140Vrms, 180VDC 0.2W 16 LED Base port switch selectable from 000H to 3FCH with increments of 4 +5VDC@100mA max. (All relays On), +12VDC@300mA max. (All relays On) 175mm x 108mm Control switching, Analog multiplexing, Motor starter control, Alarm control, Lighting control The AR-B2103 occupies 4 consecutive addresses in the PC I/O space of which only two actually used. The base or starting address is selected during the installation procedure.
Registers
The registers of the AR-B2103 are located as follows: Register Address Output Input Status
Base +0 Base +1 Base +2 Base +3 Relay Port 1(write) Relay Port 2(write) Not Used Not Used Relay Port 1(read) Relay Port 2(read) Not Used Not Used
Registers
Note that all port are 8 bit (one byte) wide and require byte oriented write operations rather than work operations. All relays in a port are updated simultaneously. Writing a low (0) to a relay within a port deactivates the relay. Writing a high (1) to a relay activates it.
The registers of the AR-B2103 are located as follows: BASE + BASE +
D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0 CH8 CH7 CH6 CH5 CH4 CH3 CH2 CH1 CH16 CH15 CH14 CH13 CH12 CH11 CH10 CH9
When the output is energized, the status LED indicator will light up to indicate an active input.
Programming
No driver is supplied with the AR-B2103 since the program is very simple and can be accomplished most efficiently using direct I/O instructions, in whatever application language is used (i.e., Basic, C, Assembly, Pascal, etc.). For example, assume that one wishes to turn on relay channel 7. Also assume the AR-B2103 board has been set to base address 992(3E0 hex). To turn on relay channel 7, one simply writes 01000000 to base address 992. Likewise to turn on channel 10, 12 and 14 one writes 42 decimal (00101010 binary or 2A hex) to I/O address 993(3 E1 hex).The following example is the BASIC language but it can be easily been translated to other languages. Example: Assume the AR-B2103 is installed at base address 992(3E0 hex). To turn on the channel 1 and 10, write as follows: 1000BASE_PORT = &H3E0: REM Base I/O addresses 1010 OUT BASE_PORT, 1: REM Turns channel 1 ON 1020 OUT BASE_PORT+1,2: REM Turns channel 10 ON To control the desired relays but make no effect to other relays, write as follows: 2000 BASE_PORT = &H3E0 : REM Base I/O addresses 2010 PORT1 = (INP (BASE_PORT) OR1): REM Read back port 1 status and set bit of channel 1 2000 OUT BASE_PORT, PORT 1: REM Turns channel 1 ON 2030 PORT2 = (INP (BASE_PORT,1) OR2): REM Read back port 2 status and set bit of channel 10 2040 OUT BASE_PORT+1, PORT2: REM Turns channel 10 ON
Ordering information:
Model No. AR-B2103 AR-B9007 Description Relay Card 37 pin Screw Terminal Board for AR-B2103 with 0.6m Round cable. Accessories (1). Disk: Win31/95 Driver