EE06 Series
Small Size Transmitter for Humidity and Temperature
EE06 series are compact transmitters for humidity, and combined humidity/temperature measurement with excellent price / performance ratio. They are optimised for OEM applications and available with or without housing. With appropriate filter cap EE06 can operate successfully even in harsh environments. The analogue output for both humidity and temperature is 0-1 V. The temperature output signal can be active or passive. The very small dimensions, low energy consumption and supply voltages down to 4.5 V allow cost-effective and easy positioning of the transmitters.
EE06 Fea tur es
very small dimensions excellent price-performance-ratio long term stability easy installation low energy consumption
T ypical A pplica tions
humidifiers and dehumidifiers climate controls in museums, hotels monitoring of storage rooms photostatic machines control meteorological applications
Tec hnical Da ta
Measuring values
Relative humidity
Sensor Output appropriate 0...100% RH Working range Accuracy at 20°C (68°F), 12V DC Temperature dependence model F/FT model FP HC101 0-1 V -0.2 mA < IL < 0.2 mA model A 0...100% RH model C model B 0...95% RH ±3% RH (0...95% RH) d RH = -0.00035 x RH x (T-20°C) d RH = typ. (-0.003 x RH + 0.01) x (T-20°C) Pt1000 (class A, DIN EN 60751) 0-1 V -0.2 mA < IL < 0.2 mA
0...100% RH
Temperature (active output)
Sensor Output appropriate -40...60°C (-40...140°F) Accuracy at 12V DC ∆°Χ
°C
Temperature (passive output)
Type of T-Sensor please see ordering guide 4.5V DC - 30V DC typ. 1.5 mA Polycarbonat / IP65 (Model A) in vertical mounting (filter cap upside) membrane filter, plastic grid, metal grid filter EN 61000-6-3 EN 61000-6-1 FCC Part15 ClassB ICES-003 ClassB working temperature: -40...60°C (-40...140°F) storage temperature: -40...65°C (-40...149°F)
General
Supply voltage Current consumption Housing Sensor protection Electromagnetic compatibility Temperature range
v2.2
EE06
37
Housing dimensions (mm)
1 mm = 0.03937” / 1” = 25.4 mm
Type A
34
Type B
2 Ø1
82 34 60
Type C
34
2 Ø1
2 Ø1
80 7
M10x1
cable length standard = 500mm (19.7”)
cable length standard = 200mm (7.9”)
cable length standard = 500mm (19.7”)
Connection Dia g r am
power supply 4.5...30V DC
+
+V (white)
-
GND (brown)
V
V
RH (green) T (yellow)
power supply 4.5...30V DC
+
+V (white)
-
GND (brown)
V
W
RH (green) Tpassive1 (yellow) Tpassive2 (gray)
Or dering Guide
MODEL
humidity and temperature (FT) humidity (F) humidity and temperature passive (FP)
OUTPUT T-SENSOR
(only passive) 0-1V (1) Pt 100 DIN A Pt 100 DIN B Pt 1000 DIN A Pt 1000 DIN B NTC 10K at 25°C (A) (B) (C) (D) (E)
TYPE
with housing (A) without housing (B) with thread (C)
FILTER
membrane filter plastic grid metal grid filter (1) (4) (6)
(Type A + C) 0.5m (1.6ft) 1.5m (4.9ft) 3m (9.8ft) 5m (16.4ft) 10m (32.8ft)
CABLE LENGTH
(no code) (K150) (K300) (K500) (K1000)
EE06-
Accessories
- radiation shield (for more information please refer to data sheet “Accessories”) (HA010502)
Or der Example
EE06-FT1A1-K300
model: output: housing: filter: cable length humidity and temperature 0-1 V with housing membrane filter 3m (9.8ft)