Data Sheet Ref: 90501177 Issue: 5.1 PM-Hx22 www.sontay.com 0-5Vdc Current transducer Technical Overview The PM-Hx22 series of current transducers can be used to monitor motors, pumps or other electrical loads where a linear voltage output signal is required. The output can be used to check operating status, failure, wear/strain and power for consumption analysis. The linear output signal is produced by the unit which is proportional to the current passing through the transducer. Features • • • 3 Selectable ranges Load trending Motor control • • For use inside a separate fire or electrical enclosure For use in a Measurement category III environment, or less, as per IEC 61010-1:2001 Specification Output Frequency Insulation class Accuracy Response time Ambient: Temperature Humidity Sensing aperture: Solid core Split core Dimensions: Sold core Split core Protection Country of origin 74H x 76W x 27D mm 74H x 65W x 26D mm IP20 U.S.A 19mm dia. 28 x 23mm (self gripping iris) -15 to 60°C 0 to 95% non-condensing 0-5Vdc (self powered) 50/60Hz 600Vac RMS ±2% of full scale 2 seconds Product Codes PM-H722LC Range selectable 0-10 / 0-20 / 0-40A solid core 0-5Vdc output PM-H722HC Range selectable 0-50 / 0-100 / 0-200A solid core 0-5Vdc output PM-H922LC Range selectable 0-30 / 0-60 / 0-120A split core 0-5Vdc output International Tel: +44 1732 861225 UK Sales Tel: 0845 345 7253 Page 1 International Fax: +44 1732 861226 UK Sales Fax: 0845 345 7353 Whilst every effort has been made to ensure the accuracy of this specification, Sontay cannot accept responsibility for damage, injury, loss or expense resulting from errors or omissions. In the interest of technical improvement, this specification may be altered without notice. 90800066 Issue 1 Data Sheet Ref: 90501177 Issue: 5.1 PM-Hx22 www.sontay.com 0-5Vdc Current transducer Installation notes (continued) (Ring type shown). Fig 1. Installation 1. The PM-Hx22 range of current transducers should only be installed by a competent, suitably trained technician, experienced in installation with hazardous voltages. (>50Vac & 75Vdc & 1500Vdc) 2. Ensure that all power is disconnected before carrying out any work on the PM-Hx22 range. Never rely on status indicating devices only to determine if power is present in a conductor. 3. When installing the split-core version ensure that there are no dirt particles that will prevent good contact between the core pieces when the device is closed. 4. Mount the sensor in a suitable location using the two mounting holes in the base of the unit or use the selfgripping iris which eliminates the need for drill mounting (split core only). 5. Maximum output cable size is 2.5mm², care must be taken not to over tighten the screw terminals. 6. Insure that the range selection slider is in the correct position for the current being monitored. Excessive current can damage the sensor. Fig 2. Wiring example Notes Low conductor current: If the load is low you can loop the conductor through the sensor to provide adequate current and ensure accuracy. Example:Load is 2.5A, pass the cable through the aperture 3 times and you will have a total load of 7.5A and set the amp range selector switch to 10A. See fig 1. High conductor current and large diameter cables: If the load is greater than the maximum specified for the transformer or the cable diameter is greater than the aperture of the current switch, you must use a suitable current transformer. See fig 2. Example:When monitoring loads greater than 200A (when using the PM-H722HC), install a suitable CT with a 5A secondary. Pass a cable connected to the secondary winding of the current transformer through the aperture ten times and set the amp range selector switch to 50A. International Tel: +44 1732 861225 UK Sales Tel: 0845 345 7253 Page 2 International Fax: +44 1732 861226 UK Sales Fax: 0845 345 7353 Whilst every effort has been made to ensure the accuracy of this specification, Sontay cannot accept responsibility for damage, injury, loss or expense resulting from errors or omissions. In the interest of technical improvement, this specification may be altered without notice. 90800066 Issue 1 Data Sheet Ref: 90501177 Issue: 5.1 PM-Hx22 www.sontay.com 0-5Vdc Current transducer Dimensions Solid core: 22mm 19mm 74mm 65mm 67mm 5mm 27mm Split core: 23mm 28mm 74mm 65mm 66mm 26mm 81mm International Tel: +44 1732 861225 UK Sales Tel: 0845 345 7253 Page 3 International Fax: +44 1732 861226 UK Sales Fax: 0845 345 7353 Whilst every effort has been made to ensure the accuracy of this specification, Sontay cannot accept responsibility for damage, injury, loss or expense resulting from errors or omissions. In the interest of technical improvement, this specification may be altered without notice. 90800066 Issue 1
PM-H922LC
1. 物料型号: 型号为TPS54360, 属于德州仪器(TI)的产品,是一款同步降压DC/DC转换器,具有高效率、高密度和低噪音的特点。

2. 器件简介: TPS54360是一款集成了电源管理功能的同步降压DC/DC转换器,适用于需要高效率和高输出电流的应用。

3. 引脚分配: 该器件拥有1个VIN引脚(输入电压),1个GND引脚(接地),4个SW引脚(开关节点),以及多个控制和状态引脚。

4. 参数特性: 包括但不限于输入电压范围、输出电压范围、最大输出电流、效率、工作温度范围等。

5. 功能详解: TPS54360具有可编程的软启动、可编程的输出电压、过载保护、热保护等高级功能。

6. 应用信息: 适用于需要高效率电源管理的便携式电子设备,如手机、平板电脑、笔记本电脑等。

7. 封装信息: 提供多种封装选项,包括但不限于QFN和D2PAK。
PM-H922LC 价格&库存

很抱歉,暂时无法提供与“PM-H922LC”相匹配的价格&库存,您可以联系我们找货

免费人工找货