B12A12005L310100U253 数据手册
Thermal motor protector Temperature limiter Thermal cut-out
12
Applications
B
- Motors - Transformers - Coils - Electronics, sensors
Benefits
- Non-sensitive to current - High current rating up to 30A - Manifold executions
CANTHERM
Technical data
control type ratings
version rated current at 250 V 50/60 Hz ( power factor 0.95 / 0.6 ) switching cycles max. current at 250 V 50/60 Hz ( power factor 0.95 ) switching cycles under max. current temperature rating Ta ( steps in 5 K ) tolerances feature of automatic action contact resistance ( incl. wire of 100 mm ) hysteresis dielectric strength ( standard insulation ) shock- / vibration testing ( similar to EN 50155 ) resistances to impregnation degrees of protection provided by enclosures ( EN 60529 ) suitable for use in protection category VDE / ENEC approvals UL CSA
1) 2)
B12A / E
normally closed 6.3 A / 4.0 A 10,000 10.0 A / 6.0 A 5,000 30.0 A 100 70 °C ... 160 °C Standard: ± 5 K 1.B.M, 2.B, 1.C, 3.C < 50 m 30 K ± 15 K 2 kV 13.0 A / 2.1 A 1,000
B12B / G
normally open 5.0 A / 1.6 A 5,000
1.B, 3.C
400 m/s2 sine half wave / 100 m/s2 5 Hz ... 2.000 Hz sine tight against ordinary resins and lacquers IP00 I, II EN 60730-1 / -2-2 / -2-3 1) /-2-9 UL 2111 / UL 873 2) C22.2 No. 77 / C22.2 No. 24 2)
different power rating on demand
Standard wire (length 100 ± 10 mm, stripped 6 ± 1 mm)
lead code
L310 150 °C stranded white L320 L340 200 °C L350 solid yellow L410 L440 150 °C 200 °C 300 V 300 V 600 V 1.50 mm 1.65 mm 1.71 mm AWG18 / 0.96 mm2 AWG20 / 0.81 mm AWG20 / 0.81 mm 3398 1332 300 V 2.15 mm 1.26 mm AWG18 / 0.96 mm2 AWG20 / 0.62 mm2 3557
temperature max.
operating voltage max.
diameter insulation
1.80 mm
cross section diameter
AWG20 / 0.48 mm2
UL style
3398
Standard insulation
control type nc no code illustration drawing dimensions ( mm ) technical specification
shrink cap potted Attention: Ta max. 155 °C
approvals
B12
A
B
U253
VDE, UL
B12
A
B
U186
cap of PPS potted
VDE, UL
Specific variations
control type nc no code illustration drawing dimensions ( mm ) technical specification approvals
B12
A
B
not insulated potted
VDE, UL, CSA
B12
A
B
U112
coated
VDE, UL
B12
A
B
U294
housing of PPS potted
VDE, UL
B12
A
B
A800
not insulated potted
VDE, UL
B12
E
G
G402
aluminium housing thread M4x6 potted Attention: Ta max. 150 °C
VDE, UL
B12
E
G
G714
brass housing thread M4x5 potted Attention: Ta max. 150 °C
VDE, UL
Heating by current
heating [K]
current [A] The diagram is measured with a thermal control without any insulation in an oil bath.
Attention:
The heating depends on the thermal conduction of the control to the equipment or part which should be protected.
Ordering and marking example
Ordering example
B12 A 120 05 L310 100 U253
Marking
B12A type (B12 nc) 12005 response temperature (120°C), tolerance (± 5K)
shrinkcap insulation length 100 mm lead wire white, AWG20 tolerance temperature normally closed type
026D
date of manufacture (Feb.2006), country (D=Germany)
Deviations from standard controls on request.
Representation office:
CANTHERM
8415 Mountain Sights Avenue • Montreal (Quebec), H4P 2B8, Canada Tel: (514) 739-3274 • 1-800-561-7207 • Fax: (514) 739-290 E-mail : sales@cantherm.com • Website: www.cantherm.com