0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
B208220600

B208220600

  • 厂商:

    ETC2

  • 封装:

  • 描述:

    B208220600 - Timers Interval - List of Unclassifed Manufacturers

  • 数据手册
  • 价格&库存
B208220600 数据手册
Timers Interval Types B 101, B 201, B 108, B 208 • Time ranges: 0.15 s to 600 s • Automatic start • Knob-adjustable time within range • Oscillator-controlled time circuit • Repeatability deviation: ≤ 1% • Output: 10 A SPDT or 8 A DPDT relay • Plug-in type module • Scantimer housing • LED-indication for relay on • AC or DC power supply Product Description Mono-function, plug-in miniature interval time relays up to 600 s (10 min) covering 3 individual time ranges. This economical timer is often used in applications such as lubricating pumps, drying elements, etc. where an operation is wanted to last for a longer period of time. Ordering Key Function Output Type Power supply Time range B 108 024 600 Type Selection Plug Circular 8 pin Circular 11 pin Circular 8 pin Circular 11 pin DPDT Output SPDT Time ranges 0.15 - 6 s 1.5 - 60 s 15 - 600 s 0.15 - 6 s 1.5 - 60 s 15 - 600 s 0.15 - 6 s 1.5 - 60 s 15 - 600 s 0.15 - 6 s 1.5 - 60 s 15 - 600 s Supply: 24 VAC/DC B 108 024 006 B 108 024 060 B 108 024 600 B 101 024 006 B 101 024 060 B 101 024 600 B 208 024 006 B 208 024 060 B 208 024 600 B 201 024 006 B 201 024 060 B 201 024 600 Supply: 120 VAC B 108 120 006 B 108 120 060 B 108 120 600 B 101 120 006 B 101 120 060 B 101 120 600 B 208 120 006 B 208 120 060 B 208 120 600 B 201 120 006 B 201 120 060 B 201 120 600 Supply: 220 VAC B 108 220 006 B 108 220 060 B 108 220 600 B 101 220 006 B 101 220 060 B 101 220 600 B 208 220 006 B 208 220 060 B 208 220 600 B 201 220 006 B 201 220 060 B 201 220 600 Time Specifications Time ranges 0.15- 6 s 1.5 - 60 s 15 - 600 s 0 to +10% on max. min. actual time ≤ min. set time Repeatability deviation Time variation Within rated power supply and ambient temperature Reset Time and/or relay ≤ 1% ≤ 0.05%/V ≤ 0.2%/°C Power supply interruption ≥250 ms Time range accuracy Specifications are subject to change without notice (25.10.99) 1 B 108, B 208, B 101, B 201 Output Specifications B 108, B 101 Output Basic electrical insulation Contact ratings (AgCdO) Resistive loads AC 1 DC 1 or Small inductive loads AC 15 DC 13 Mechanical life Electrical life AC 1 Operating frequency Insulation voltages Rated insulation voltage Rated transient protection volt. SPDT relay 250 VAC (rms) (contact/electronics) µ (micro gap) 10 A/250 VAC (2500 VA) 1 A/250 VDC (250 W) 10 A/25 VDC (250 W) 2.5 A/230 VAC 5 A/24 VDC ≥ 30 x 106 operations ≥ 2.5 x 105 operations (at max. load) ≤ 7200 operations/h ≥ 2.0 kVAC (rms) (contact/electronics) 4 kV (1.2/50 µs) (contact/electronics) (IEC 60664) B 208, B 201 DPDT relay 250 VAC (rms) (contacts/elec., contact/contact) µ (micro gap) 8 A/250 VAC (2000 VA) 0.4 A/250 VDC (100 W) 4 A/25 VDC (100 W) 2.5 A/230 VAC 5 A/24 VDC ≥ 30 x 106 operations ≥ 2.5 x 105 operations (at max. load) ≤ 7200 operations/h ≥ 2.0 kVAC (rms) (contact/electronics) 4 kV (1.2/50 µs) (contact/electronics) (IEC 60664) Supply Specifications Power supply AC types Rated operational voltage through pins 2 & 10 220 or pins 2 & 7 120 024 Drop-out tolerance Rated insulation voltage Rated transient protection volt. Installation cat. III 220 VAC + 15/- 20%, 45 to 65 Hz 120 VAC + 15/- 20%, 45 to 65 Hz 24 VAC + 15/- 20%, 45 to 65 Hz ≥ 10 ms None 4 kV (1.2/50 µs) @ 220 VAC 2.5 kV (1.2/50 µs) @ 120 VAC 800 V (1.2/50 µs) @ 24 VAC (line/neutral) Installation cat. III 24 VDC + 15/- 20% (pin 2 pos.) None 800 V (1.2/50 µs) 60 mA @ 50 Hz/70 mA @ 60 Hz 1W General Specifications Power ON delay Power OFF delay Indication for Output ON Environment Pollution degree Operating temperature Storage temperature Weight Approvals ≤ 200 ms ≥ 250 ms LED. red IP 20 B 2 (IEC 60664) -20° to +50°C (-4° to +122°F) -50° to +85°C (-58° to +185°F) 85 g UL, CSA Power supply DC type Rated operational voltage 024 Rated insulation voltage Rated transient protection volt. Consumption AC supply DC supply Mode of Operation The relay operates and the time period starts when power supply is applied to the time relay. At the end of the set delay, the relay releases and will not operate again until power supply is reapplied. A recovery period of 250 ms should be allowed before reapplying power supply. If power supply is interrupted for more than 250 ms before the time period has expired, the relay releases and the time is reset to zero. Wiring Diagrams Power supply B 108, B 208 Power supply B 101, B 201 2 Specifications are subject to change without notice (25.10.99) B 108, B 208, B 101, B 201 Time Setting Knob-adjustable on scale in seconds. Accessories Sockets◊ Hold down spring◊ Mounting rack Socket cover Potentiometer lock S 408, S 411 HF SM 13 BB 4 PL 1 For further information refer to "Accessories". Operation Diagram Power supply Relay on Specifications are subject to change without notice (25.10.99) 3
B208220600 价格&库存

很抱歉,暂时无法提供与“B208220600”相匹配的价格&库存,您可以联系我们找货

免费人工找货