CLP2ET1C230

CLP2ET1C230

  • 厂商:

    ETC2

  • 封装:

  • 描述:

    CLP2ET1C230 - Conductive Sensors 2-point level controller - List of Unclassifed Manufacturers

  • 详情介绍
  • 数据手册
  • 价格&库存
CLP2ET1C230 数据手册
Conductive Sensors 2-point level controller Type CL with teach-in • Conductive level controller • Teach-in of sensitivity – operating resistance from 220Ω to 220KΩ • For filling or emptying applications • Low-voltage AC electrodes • Easy installation on DIN rails or with 11 pin circular plug • Rated operational voltage: 24 VAC/DC, 115 VAC or 230 VAC • Output 2x5A/250 VAC DPDT relay • LED indication for: Calibration, faulty operation and relay status Product Description µ-Processor based level controller for liquids with a wide sensitivity range (like sewage water, chemicals, salt water etc.). Max./min. control of charging/ discharging. The sensitivity is adjustable by means of the teach-in function. 2 X 5A DPDT relay output. Ordering Key Type DIN rail mounting Inputs Function Adjustment Outputs Relay versions Power supply CLD2ET1CM24 Type Selection Mounting DIN-rail 11-p circular plug Relay DPDT Ordering no. Supply: 24 VAC/DC CLD2ET1CM24 CLP2ET1CM24 Ordering no. Supply: 115 VAC CLD2ET1C115 CLP2ET1C115 Ordering no. Supply: 230 VAC CLD2ET1C230 CLP2ET1C230 Specifications Rated operational voltage (UB) Pin 2 & 10 230 115 924 Rated insulation voltage Rated impulse withstand voltage Rated operational power AC supply AC/DC supply Delay on operate (tV) Outputs Rated insulation voltage Relay Rating (AgCdO) Resistive loads Dielectric voltage 195 to 265 VAC, 45 to 65 Hz 98 to 132 VAC, 45 to 65 Hz 19.2 to 28.8 VAC/DC 250’000 operations Max. 12 VAC Max. 2.5 mA 220Ω to 220KΩ Factory preset: 47KΩ Rated impulse withstand volt. Operating frequency (f) Relay output Response time Environment Overvoltage category Degree of protection Pollution degree Temperature Operating Storage Housing material Weight AC supply AC/DC supply Approvals CE marking >2.0 KVAC (rms) (contacts / electronics) 4 kV (1.2/50 µS) (contacts / electronics) (IEC 664) 1 HZ 1 s (3.5 s with filter) III (IEC 60664) IP 20 /IEC 60529, 60947-1) 2 (IEC 60664/60664A, 60947-1) -20º to +70ºC (-4º to + 158º) -50º to +85ºC (-58º to +185ºF) NORYL SE1, light grey 200 g 125 g UL508, CSA Yes Small induc. Loads Mechanical life (typical) Electrical life (typical) Level probe supply Level probe current Sensitivity AC1 DC1 or AC11 DC13 AC1 Specifications are subject to change without notice (08.12.2005) 1 CLD2ET1CM24 Mode of Operation Connection cable 2, 3, or 4 conductor PVC cable, normally screened. Cable length: max. 100 m. The resistance between the cores and the ground must be at least 220k. Normally, it is recommended to use a screened cable between probe and controller, e.g. where the cable is placed in parallel to the load cables (mains). The screen has to be connected to Y3 (reference). DIP-switch setting Select the needed function on the DIP-switches, so that the desirable application occurs. Press the pushbutton in front of the controller shortly, until the green LED flashes once. The DIPswitch setting will now be read by the controller. Teach-in: Make sure that the reference electrode and one of the other electrodes are in contact with the liquid – approximately 1 cm. Press the “teach” pushbutton at the front of the controller for approximately 2 seconds, until the green LED turns OFF. The controller will now auto-adjust itself according to the resistance of the measuring liquid. If the resistance of the liquid is outside the maximum range handled by the controller, the green LED will flash quickly for a period of 2 seconds, indicating a wrong teach-in. Filter The signal delay is selectable from 1 second or 3 seconds, and works for the on/off switching of the output relays. Example 1 The diagram shows the level control connected as max. and min. control. The relays react to the low alternating current created when the electrodes are in contact with the liquid. The reference (Ref) must be connected to the container or if the container consists of a non-conductive material, to an additional electrode. (To be connected to pin Y3). (In the diagram this electrode is shown by the dotted line). Example 1 (Din-rail) REF Y2 Lo Hi 12 14 A1 11 21 Y1 Y3 22 24 A2 Charging or discharging Power Supply Function: Charge or Discharge The Controller can be used as a minimum-maximum control for one system. ON DIP switches 1 1 2 2 ON Discharge Charge Filter off Filter on X-REFERENCE TERM Y1 Y2 Y3 22 A1 A2 11 12 14 21 24 PLUG 6 5 7 8 2 10 1 4 3 11 9 Charging Power supply LO electrode in liquid HI electrode in liquid Relay on pumping contact (make) Discharging Power supply HI electrode in liquid LO electrode in liquid Relay on pumping contact (make) Time 2 Specifications are subject to change without notice (08.12.2005) CLD2ET1CM24 Operating Schedule The following schedule provides an overview of the setup and failure situations Situation Condition Action Green Control lamp Read DIP-switch setting The DIP-switch setting has to match one of the descriptions written in ”mode of operation” Press the Teach-button in front of the controller shortly until the green control lamp turns off. Release the teach button immediately Teach button Green lamp Teach-in Fill the tank with the liquid to be measured until the second longest electrode is immersed approx. 1cm Press the Teach button in front of the controller for approx. 2 seconds until the green control lamp turn off continuously. Release the teach button Teach button Green lamp Failure indication The Green lamp is flashing fast for approx. 2 seconds after a teach-in operation Control the electrode for short-cut connections. Control that the resistance of the measured liquid is within the specified range Teach button Green lamp Wiring Diagram Din-rail version Plug version A1 12 14 22 24 2 4 3 8 9 Hi Lo Y2 Y1 Y3 (PE) Hi Lo A2 5 6 7 (PE) 11 21 10 1 11 Ref Ref Dip Switch Settings ON DIP switches 1 1 2 2 ON Discharge Charge Filter off Filter on Specifications are subject to change without notice (08.12.2005) 3 CLD2ET1CM24 Dimension Drawings Din-rail version Plug version 45 41,5 60,2 81 35,5 35,5 Accessories • 11 pole corcular socket • Mounting rack ZVD11 SM13 Delivery Contents • Amplifier • Packaging: Carton box • Manual 4 Specifications are subject to change without notice (08.12.2005) 21 63
CLP2ET1C230
1. 物料型号: - DIN-rail 型号:CLD2ET1CM24 - 11-p circular plug 型号:CLP2ET1CM24

2. 器件简介: - 该器件是一个基于微处理器的导电式液位控制器,适用于具有广泛灵敏度范围的液体(如污水、化学品、盐水等)的充/放电控制。灵敏度可通过教授功能进行调整,具有2x5A DPDT继电器输出。

3. 引脚分配: - Y1: 6号引脚 - Y2: 5号引脚 - Y3: 7号引脚 - 22: 8号引脚 - A1: 2号引脚 - A2: 10号引脚 - 11: 1号引脚 - 12: 4号引脚 - 14: 3号引脚 - 21: 11号引脚 - 24: 9号引脚

4. 参数特性: - 额定工作电压:24VAC/DC, 115VAC或230VAC - 额定绝缘电压:<2.0 kVAC (rms) - 额定冲击耐受电压:4 kV (1.2/50 s) (线/中性) - 额定工作功率:5VA(交流供电)/ 5VA/5W(交流/直流供电) - 操作延迟:<300mS - 继电器额定绝缘电压:250 VAC (rms)(连续/电气) - 继电器额定(AgCdO):(微间隙) - 电阻负载:AC1 DC1 5 A/ 250 VAC (2500 VA) 1 A/ 250 VDC(250 W) - 小感性负载:AC11 0.4A 250 VAC - 机械寿命(典型):DC13 0.4A/30VDC ≥30x10^6次操作 18'000次/小时 - 电气寿命(典型):AC1 >250'000次操作 - 液位探头供电:最大12 VAC - 液位探头电流:最大2.5 mA - 灵敏度:220至220K,出厂预设:47K

5. 功能详解: - 控制器可以作为最小-最大控制用于一个系统,通过DIP开关选择所需功能,使控制器读取DIP开关设置。 - 信号延迟可选择1秒或3秒,用于输出继电器的开关。 - 教授功能允许控制器根据测量液体的电阻自动调整自身。

6. 应用信息: - 适用于填充或清空应用,低电压交流电极,易于安装在DIN导轨或使用11针圆形插头。

7. 封装信息: - 外壳材料:NORYL SE1,浅灰色 - 重量:交流供电200g,交流/直流供电125g - 认证:UL508, CSA - CE标记:是
CLP2ET1C230 价格&库存

很抱歉,暂时无法提供与“CLP2ET1C230”相匹配的价格&库存,您可以联系我们找货

免费人工找货