0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
FAA08DM24

FAA08DM24

  • 厂商:

    ETC2

  • 封装:

  • 描述:

    FAA08DM24 - Timers Delay on Operate - List of Unclassifed Manufacturers

  • 数据手册
  • 价格&库存
FAA08DM24 数据手册
Timers Delay on Operate Types FAA01, FAA08 • • • • Time range 0.05 s to 300 h Knob selection of time range Knob adjustable time setting Knob selection of operating mode (4 functions): A - delay on operate B2 - symmetrical recycler ON first E - interval J - one shot Automatic start Repeatability: ±0.3% on full scale Output: 5 A DPDT relay 48 x 48 mm housing for front panel mounting 8 or 11 pin sockets LED indication for relay status and power supply ON • • • • • • Product Description Delay on operate timer with 4 functions and selectable time ranges from 0.05 seconds to 300 hours. Housing 48 x 48 mm for front panel mounting and on 8-pin or 11-pin socket. Ordering Key Housing Function Type Item number Output Power supply FAA 01 D M24 Type Selection Mounting Front or socket Front or socket Output DPDT DPDT Plug 11-pin 8-pin Supply: 100 to 240 VAC FAA01DM24 FAA08DM24 Time Specifications Time ranges Selectable by front knob Time unit 1.2 Full scale setting 3 12 30 Repeatability Setting accuracy Voltage drift sec min 0.05 to 1.2 0.125 to 3 0.5 to 12 1.25 to 30 hrs 10h 0.5 to 12 1.25 to 3 5 to 120 12.5 to 300 Output Specifications Output Output insulation resistance Contact Ratings (AgCdO12) Resistive loads AC 1 Mechanical life Electrical life DPDT relay > 100 MΩ (at 500 VDC) µ 5 A @ 250 VAC / 30 VDC ≥ 1 x 107 operations ≥ 1 x 105 operations (5 A at 250 VAC, cos ϕ = 1, 1.8 x 103 operations/h) < 1800 operations/h Temperature drift ±0.3% on full scale (±10 ms max in the range of 1.2 s) ±5% on full scale ±50 ms ±0.5% on full scale (±10 ms max in the range of 1.2 s) ±2% on full scale (±10 ms in the range of 1.2 s) >100 ms >50 ms Operating frequency Supply Specifications Power Supply Rated operational voltage throuhgt terminals: (FAA01DM24) 2, 10 (FAA08DM24) 2, 7 Overvoltage cat II (IEC 60947-1) 100 to 240 VAC +10%-15% 50 / 60 Hz 100 to 240 VAC +10%-15% 50 / 60 Hz 10VA @ 240 VAC, (50 Hz) Reset Power supply interruption Pulse width Power consumption Rated operational power Specifications are subject to change without notice (26.07.05) 1 FAA01, FAA08 General Specifications Indication for Power supply On Output ON Environment Degree of protection Operating temperature Ambient humidity Housing dimesions Weight CE marking EMC Immunity Emission LED, green (flashing when timing) LED, red IP 40 (front panel) -10 to +55 °C (14 to 131 °F) 35 to 85% RH 48 x 48 mm Approx. 95 g Yes Electromagnetic Compatibillity According to EN 61000-6-1 According to EN 61000-6-3 Function and Time Setting Upper right knob: Setting of function A - delay on operate B2 - simmetrical recycler E - interval J - one shot Lower right knob: Time unit selector sec (seconds) min (minuts) hrs (hours) 10h (10 hours) Lower left knob: Time range selector 1.2, 3, 12 and 30 Centre knob: Time setting on relative scale Mode of Operation Function A Delay on operate The set delay period begins as soon as the power supply is connected. At the end of the set delay the relay operates and doesn’t release until the power supply is interrupted for at least 100 ms. Function B2 Symmetrical recycler (ON first) The relay operates and the time period start as soon as the power is applied. At the end of the first set time period, the relay releases. At the end of the second time period (equal to the first), the relay operates again. This sequence continues with equal ON- and OFF- time periods until the power supply is interrupted for at least 100 ms. Function E Interval The relay operates and the time period begins as soon as the power is applied. The relay releases at the end of the time period or when the power supply is disconnected for at least 100 ms. Function J One shot The time period begins as soon as the power supply is connected and at the end of this period the relay operates for 1s. Range and operation mode selection Power indicator (green) (Flashes when timer operates; on when timer stops operating) Output indicator (red) (Lit when output is ON) Operating mode display window Operating mode selector (function A, B2, E, J) Scale range display windows Time range selector (1.2, 3, 12 and 30 at full scale) Time unit display window Time unit selector (sec, min, hrs, 10h) Time setting knob (set time) 2 Specifications are subject to change without notice (26.07.05) FAA01, FAA08 Wiring Diagrams FAA01 L(+) 2 4 µ m µ m FAA08 L(+) 9 2 4 m µ 3 5 m µ 6 3 8 10 1 11 7 1 8 N(-) N(-) Operating Diagrams Function A - Delay ON operate Function B2 - Symmetrical Recycler (ON first) Power supply Power supply Relay T T Relay T T T T T LED “POWER” LED “POWER” Function E - Interval Function J - One Shot Power supply Power supply 1s±0.6s 1s±0.6s T Relay T Relay T T LED “POWER” LED “POWER” Dimensions FAA01 - FAA08 15 15 48 48 9 6 81,6 81.6 60,2 68.2 48 48 39 39 Specifications are subject to change without notice (26.07.05) 3
FAA08DM24 价格&库存

很抱歉,暂时无法提供与“FAA08DM24”相匹配的价格&库存,您可以联系我们找货

免费人工找货