0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
FFD1680024

FFD1680024

  • 厂商:

    ETC2

  • 封装:

  • 描述:

    FFD1680024 - Transmitter for Numerical Counter Signals - List of Unclassifed Manufacturers

  • 数据手册
  • 价格&库存
FFD1680024 数据手册
Transmitter for Numerical Counter Signals Type FFD 1680 • • • • • • • • Du line ® Fieldbus Installationbus Transmitter with counter input 4-digit totalizing up-counter Overflow indication Reset input D-housing Plug-in type module LED-indication for supply AC or DC power supply Product Description Dupline ® transmitters with pulse input and 4-digit totalizing up-counter. Reset and disable inputs. Detection, upcounting and transmission of low-frequency events for readout, control, logging etc. Ordering Key Type: Dupline® Input signal Supply FFD 1680 024 Type Selection Supply Ordering no. 4-digit counter FFD 1680 024 FFD 1680 120 FFD 1680 220 24 VAC 120 VAC 220 VAC 10 to 30 VDC* Code module * All AC types may be supplied with 10 to 30 VDC at pins 3 & 9 FMK A-B to O-P Input Specifications Count input Open loop voltage Short-circuit current Counting range Counting direction Input frequency Contact resistance Dielectric voltage Input - Dupline® Reset input Open loop voltage Short-circuit current Operating time for signal "1" Operating time for signal "0" Contract resistance Cable length Dielectric voltage Input - Dupline® 1 contact or NPN transistor 8 VDC 2 mA 0 to 9999 Up ≤ 25 Hz ≤ 100 Ω None 1 contact or NPN transistor 8 VDC 2 mA ≤ 1 pulse train + 20 ms ≤ 1 pulse train + 20 ms ≤ 100 Ω ≤3m None Transmission disable input Open loop voltage Short-circuit current Operating time for signal "1" Operating time for signal "0" Contact resistance Cable length Dielectric voltage Input - Dupline® 1 contact or NPN transistor 8 VDC 2 mA ≤ 1 pulse train + 10 ms ≤ 1 pulse train + 10 ms ≤ 100 Ω ≤3m None Specifications are subject to change without notice (28.09.99) Dupline® is a registered trademark. A product of the CARLO GAVAZZI Group 1 FFD 1680 Du line ® Fieldbus Installationbus Supply Specifications Power supply AC types Rated operational voltage through pins A1 & A2 220 120 024 Frequency Voltage interruption Rated operational power Rated operational withstand voltage 220 120 024 Dielectric voltage Supply - Dupline® Supply - Count input Supply - Reset/Disable input Alternative DC supply Supply voltage (VDD in) through pins 3 & 9 Ripple Reverse polarity protection Rated operational current Inrush current Rated operational withstand voltage Dielectric voltage Supply - Dupline® Supply - Count input Supply - Reset/Disable input Overvoltage cat. III (IEC 60664) 230 VAC +6%, -15% (IEC 60038) 120 VAC ± 10% (IEC 60038) 24 VAC ± 10% 45 to 65 Hz ≤ 40 ms Typ. 2.5 VA 4 kV 2.5 kV 800 V ≥ 2 kVAC (rms) ≥ 2 kVAC (rms) ≥ 2 kVAC (rms) Overvoltage cat. III (IEC 60664) 10 to 30 VDC (ripple included) ≤3V Yes ≤ 20 mA ≤1A 800 V None None None General Specifications Power ON delay Indication for Supply ON Environment Degree of protection Pollution degree Operating temperature Storage temperature Humidity (non-condensing) Mechanical resistance Shock Vibration Dimensions Material (see "Technical Information") Weight Approvals Undefined, ≤ 1 s LED, green IP 20 B 3 (IEC 60664) -20° to +50°C (-4° to +122°F) -50° to +85°C (-58° to +185°F) 20 to 80% 15 G (11 ms) 2 G (6 to 55 Hz) D-Housing 200 g CSA Mode of Operation Transmitters with 4-digit pulse counting function. The module features reset and transmission disable inputs. The accumulated counting value is transmitted in BCD representation on the Dupline. This implies that every digit uses 4 channels. The-digitto-channel allocation is as follows (example with FFD 1680 and FMK C-D plugged in): 100 on highest 4 selected channels (e.g. D5-8). 101 on lower 4 channels of higher group (e.g. D1-4). 102 on higher 4 channels of lower group (e.g. C5-8). 103 on lowest 4 selected channels (e.g. C1-4). For every digit the most significant bit of the BCD equivalent influences the lowest of the 4 allocated channels. Activation of the reset function (pin 3 connected to pin 1) always resets the internal counter to 0, irrespective of the disable and counting inputs. When the transmission disable function is activated (pin 3 connected to pin 5), the transmitter does not transmit its value via the Dupline® whereas the internal counter can still operate. A Dupline® system can have several FFD 1x80s coded to the same channel groups. In this case the counting values may only be emitted from one transmitter at a time, the other transmitters must be disabled in the meantime. This feature is best obtained by using Dupline® receivers with demultiplex output type D 1230 5111 connected to the transmission disable inputs. FK3C 7640 and FL3C 7640 or D 6369 6475 can be used for display of FFD 1680 values. FK3C 7760 and FL3C 7760 can be used for display of FFD 1780 values. Overflow: When the counter reaches 9999 (999999), the transmitter activates all coded channels, thereby causing Dupline® displays to become dark. Note: If DC-supplied FFD .... transmitters are used, the length of the supply bus must not exceed 3 m in order to avoid disturbances unbalancing the Dupline®. Note: Transmitters for numerical signals must not be used in systems where channel generators with 2 or 3 sequences are installed. 2 Specifications are subject to change without notice (28.09.99) Dupline® is a registered trademark. A product of the CARLO GAVAZZI Group FFD 1680 Du line ® Fieldbus Installationbus Operation Diagram Power supply Counter input Reset input Transmission Disable input Transmission value Wiring Diagram Accessories Socket◊ Socket cover Hold down spring◊ Front mounting bezel DIN-rail for D 411 D 411 BB 5 HF FRS 2 FMD 411 No conn. Count input Reset Transmission Disable VDD in For further information refer to "Accessories". S: signal wire. Power Supply Specifications are subject to change without notice (28.09.99) Dupline® is a registered trademark. A product of the CARLO GAVAZZI Group 3
FFD1680024 价格&库存

很抱歉,暂时无法提供与“FFD1680024”相匹配的价格&库存,您可以联系我们找货

免费人工找货