Counters 24 x 48 digital counters Types FKA01, FKA02, FKA03
• 8-digit LCD display • 8 mm digits • Reset button with locking function • 8 years battery lifetime • 2 inputs (FKA01, FKA02); 1 input (FKA03) • Up-down counting mode (through electrical control) • For front panel mounting • 24 x 48 mm housing • Filter function for bounce-free counting with mechanical contacts
Product Description
24 x 48 mm up to 2 inputs up-down counters for flush mounting. NPN, PNP or voltage inputs allow connection to any type of sensors or open collector output. The front key, which can be locked, allows fast and easy counting reset.
Ordering Key
Housing Function Type Item number Output Input range
FKA 01 X 724
Type Selection
Mounting Front panel Front panel Front panel Input NPN or voltage free contact NPN, PNP or voltage free contact Voltage Counting mode Adding/Substracting Adding/Substracting Adding Max. couting freqency 7 KHz 12 KHz 30 Hz Model FKA01X724 FKA02X724 FKA03XW24
Input Specifications
Input A (FKA01) Input type Low level High level Max counting frequency Input resistance Input A (FKA02) Input type Low level High level Max counting frequency Input resistance Input A (FKA03) Input type Low level High level Min pulse time Max counting frequency Input resistance Input B (FKA01, FKA02) Input type Low level High level Max counting frequency Input resistance NPN open collector or voltage free contact 0 to 0,7 V DC 3 to 30 V DC 7 kHz ≈1 MΩ PNP open collector or voltage free contact 0 to 0,7 V DC 4 to 30 V DC 12kHz ≈100 kΩ Voltage (10 to 260 V AC/DC) (galvanic insulation) 0 to 2 V AC/DC 10 to 260 V AC/DC 16 ms 30 Hz ≈160 kΩ NPN open collector or voltage free contact 0 to 0,7 V DC 3 to 30 V DC 30 Hz ≈1 MΩ Input B (Reset) (FKA03) Input type Low level High level Min pulse time Max counting frequency Input resistance Reset (FKA01, FKA02) Input type Voltage (10 to 260 V AC/DC) (galvanic insulation) 0 to 2 V AC/DC 10 to 260 V AC/DC 16 ms 30 Hz ≈160 kΩ NPN open collector or voltage free contact 0 to 0,7 VDC 3 to 30 V DC 50 ms ≈2 MΩ
Low level High level Min pulse time Input resistance Electrical locking of the reset key NPN open collector or Input type voltage free contact Low level 0 to 0,7 V DC High level 3 to 5 V DC Input not active Reset key locked Input in contact with GND Reset key unlocked Input resistance ≈2,2 MΩ Operating mode switch (FKA01, FKA02) Input type NPN open collector or voltage free contact 0 to 0,7 V DC Low level Hight level 3 to 5 V DC Adding mode Input not active Subtracting mode Input in contact with GND ≈2,2 MΩ Input resistance
Specifications are subject to change without notice (13.09.06)
1
FKA01, FKA02, FKA03
General Specifications
Power supply Non-reaplaceable lithium battery (lifetime up to 8 years at 20°C) II (EN 61010 Part 1) Housing dimesions Weight Panel cut out Screw terminals Tightening torque Approvals CE Marking EMC Immunity Emission 24 x 48 mm 50 g 22,2+0,3 x 45+0,6 mm Max. 0.5 Nm according to IEC EN 60947 UL Yes Electromagnetic Compatibillity According to EN61000-6-2 According to EN61000-6-3
Overvoltage category (FKA03: Inp A, Inp B) Display Counting range FKA01, FKA02 FKA03 Counting direction FKA01, FKA02 FKA03 Digit height Environment Degree of protection Pollution degree Operating temperature Storage temperature
-9999999 to 99999999 0 to 99999999 Up or down Up 8 mm (EN 60529) IP 65 front 2 -10° to +55°C, R.H.